U.S. ESCO Industry Report: Industry Size and Recent Market Trends, 2022- 2024

The latest edition of the U.S. Energy Service Company (ESCO) Industry Report by Lawrence Berkeley National Laboratory (LBNL) finds that the U.S. ESCO industry continues to show strong growth. The report draws from ESCO industry reported revenue data for the 2022-2024 period, detailing the current size and characteristics of the U.S. ESCO industry. Following 20 years of ESCO industry reports, the 2024 report explores significant revenue trends across market segments, geographic regions, ESCO size, financing structures, and business activities. New analysis in this report outlines customer priorities and non-energy benefit drivers of Energy Savings Performance Contract projects, adjusted revenue analysis detailing the impacts of inflation on industry growth, and project challenges by market segment.

Chelminski, Kathryn

RADAI: A Large-Scale Realistic Dataset for Radiation Detection Algorithm Development

Open, realistic datasets are essential for developing and benchmarking radiation detection algorithms, yet they remain scarce. The Radiological Anomaly Detection and Identification (RADAI) project was develop to create datasets that meet the training and testing needs for sophisticated radiation detection algorithms. The RADAI dataset is a large-scale synthetic resource that integrates high-fidelity Monte Carlo simulations with realistic urban scenarios to capture both background variability and source signatures. RADAI models construction-material NORM, people and vehicles, urban clutter, and dynamic environmental effects such as cosmic-ray and rain-induced transients, and they provide list-mode detector data with motion and response modeling suitable for algorithm training and evaluation. The RADAI project resulted in three publicly-released complementary datasets together with an online scoring portal for standardized performance assessment and an open software toolkit that supports data access, augmentation, model development, and evaluation. These resources enable reproducible comparisons across methods and promote rigorous studies at the scale required by contemporary machine learning. By grounding algorithm development in realistic, well-documented conditions, RADAI supports progress toward more robust detection, identification, and localization in complex urban environments.

Ghawaly, James M. [Division of Computer Science an

Using Open Innovation in Reducing Risk to Crews

In the exploration of destinations outside of Earth's neighborhood, specifically Mars, scientific and engineering inquiries have occurred by two means; observations from satellites and observations by landed spacecraft. Satellite observations (Mariner, MRO, Mars Odyssey, provide global-scale spatial and temporal data while landed spacecraft (Viking, Mars Pathfinder, Spirit, Opportunity, Phoenix Mars Lander) investigate highly localized areas of the surface of the planet. In preparation for human exploration, extensive knowledge of the surface and atmospheric environments should be known before the first human leaves Earth. The primary goal of performing reconnaissance on Mars on a sub-global scale is to know as much as possible about the environment to which crews will be subjected. At the current rate of launching and landing probes to Mars, it will take a very long time to understand the surface and atmospheric conditions associated with the regions where prospective crews may land. Meanwhile electronics and electrical systems are rapidly getting smaller. One can argue that to acquire the knowledge of the region, one must take hundreds, maybe thousands of measurements simultaneously. One means to perform such a task is to deploy a swarm of sensors. Such a swarm would perform an in-situ assessment of the region. Imagine a close flyby mission to Mars for example, where mini- to micro-sensors are deposited into the atmosphere over half an orbit or more. The sensors, captured by the atmospheric drag and Martian gravity slowly descend buffeted about by Martian winds and weather until they settle on the surface a great time later (think of how long dust takes to settle). As they descend they communicate a vast array of data; temperature, chemistry, pressure, radiation dose, electric or magnetic properties from a region of the planet and an individual sensor need not measure the same quantity as its neighbors. Initially, they could move at the whim of the environment but later versions could have locomotion or propulsion mechanisms. Humans wouldn't need to decide where the sensors go, the sensors do that for themselves. This is a key strength of a sensor swarm. The intelligence relies on the group not on a decision maker on earth. Real time sensor inputs direct what the swarm considers most interesting to investigate resulting in emergent behavior. We issued a $20,000 challenge to the global innovators to provide solutions as to how such a swarm could be initialized and by what protocols and methodologies by which they operate. Over 400 innovators from 49 countries took a look at the problem, with three receiving partial awards for solutions.

Mel Ferebee

Multikilowatt Bipolar Nickel/Hydrogen Battery

High energy densities appear feasible. Nickel/hydrogen battery utilizing bipolar construction in common pressure vessel, addressing needs for multikilowatt storage for low-Earth-orbit applications, designed and 10-cell prototype model tested. Modular-concept-design 35-kW battery projected energy densities of 20 to 24 Wh/b (160 to 190 kj/kg) and 700 to 900 Wh/ft3 (90 to 110 MJ/m3) and incorporated significant improvements over state-of-the-art storage systems.

Source record

Development and Validation of Low-Cost, High-Reflectance Composite CSP Facets: SIPS Final Report

This work investigates the various challenges associated with developing heliostat structural composite facets using 1 mm glass mirrors. Such facets are desirable for Concentrating Solar Power because 1 mm glass mirrors provide an absolute increase in reflectivity of 2-3 % over the industry standard of 4 mm glass mirrors. Prototypes of paraboloid composite facets with 1 mm glass mirrors were constructed that have a root mean square slope error on the order of 2 mrad while achieving greater than 96% reflectivity. These facets were constructed using a low-quality aluminum mold and a bill of materials that show potential to achieve cost parity with existing 4 mm glass mirrors supported by structural steel. The facets produced were able to survive up to 50 mm hail ball impacts and were robust against accelerated environmental cycling designed to expose durability concerns. Further work is needed to develop a scalable and cost-effective manufacturing process with a similar bill of materials.

14 SOLAR ENERGY

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Prediction of prompt NO(x) in hydrocarbon air flames

The gas turbine industry is directing particular attention to very low NOx combustors, whether for aircraft or land based CCGT systems. These low NOx combustors frequently use liquid fuels or natural gas burning under very lean premixed conditions with air or under rich-lean conditions, although only the first case is studied here. In land based systems, diluted steam or nitrogen are sometimes injected into the combustion chambers to reduce flame temperature. The NOx emissions from such systems are the product of three chemical mechanisms which are interrelated: the hydrocarbon prompt NO, the thermal NO (extended Zeldovich mechanism), and the nitrous oxide route to NO. Formation of NO2 from NO also occurs, as well as emission of carbon monoxide and unburnt hydrocarbons. When the fuel-oxidant proportion decreases towards leaner conditions, flame temperatures are lowered, resulting in the total NO being reduced and the thermal-NO contribution greatly diminished to the benefit of the remaining two mechanisms of NO formation. While knowledge of the elementary reactions and their chemical kinetics concerning methane and simple hydrocarbons combustion has existed for a number of years, its use for computer modeling is limited to simple flow dynamics configurations. Nevertheless, understanding of such combusting flows under a wide range of experimental conditions allows for analogies or speculations with more complex actual systems. Such understanding can be achieved by means of one dimensional laminar premixed flame modeling, with a full chemical mechanism which incorporates the three routes of NO formation. Complementary to this understanding is the modeling of the actual combustion system using a full description of the fluid dynamics coupled with a reduced chemical scheme, which is then compared against the first model. The objective of this investigation is to evaluate the relative importance of the three mechanisms of NO formation in lean premixed methane-air combustion with increasing pressure using the one dimensional plug flow package PREMIX, and to test the validity of a three dimensional model with a global chemical mechanism against the one dimensional model in the atmospheric pressure case. Methane is chosen because it is the only mechanism which is reasonably well known and is a good guide to the behavior of other hydrocarbons. The mixture ratio chosen is richer than that in lean gas turbines, but the combustion of this mixture with the low preheat gives realistic gas turbine final flame temperatures. Conditions of NO2 formation are also analyzed in the one dimensional model and results extrapolated to the case of gas turbines.

Valerie Dupont

Polaron catastrophe within quantum acoustics

The quantum acoustic framework has recently emerged as a nonperturbative, coherent approach to electron–lattice interactions, uncovering rich physics often obscured by perturbative methods with incoherent scattering events. Here, we model the strongly coupled dynamics of electrons and acoustic lattice vibrations within this framework, representing lattice vibrations as coherent states and electrons as quantum wave packets, in a manner distinctively different from tight-binding or discrete hopping-based approaches. We derive and numerically implement electron backaction on the lattice, providing both visual and quantitative insights into electron wave packet evolution and the formation of acoustic polarons. We investigate polaron binding energies across varying material parameters and compute key observables—including mean square displacement, kinetic energy, potential energy, and vibrational energy—over time. Our findings reveal the conditions that favor polaron formation, which is enhanced by low temperatures, high deformation potential constants, slow sound velocities, and high effective masses. Additionally, we explore the impact of external electric and magnetic fields, showing that while polaron formation remains robust under moderate fields, it is weakly suppressed at higher field strengths. These results deepen our understanding of polaron dynamics and pave the way for future studies into nontrivial transport behavior in quantum materials.

Science & Technology - Other Topics

Oversizing and Part-Load Problems

Oversizing, the common engineering practice of specifying devices with capacity exceeding the actual load requirement, is a widespread practice across virtually all building technologies end-use categories, including HVAC, electrical systems, lighting, appliances, and plug loads. This practice, driven by factors like design uncertainty, institutional pressures, and risk aversion, results in wasted capital investment, control difficulties, and excessive energy consumption due to inefficient part-load operation. Part-load operation, where devices run below maximum capacity, is the dominant operating mode in most energy systems and presents a complex design challenge. Solutions to match output to load fall into three broad categories: constraining the output, adjusting the device’s internal behavior, and linking output to energy storage or other waste-heat reuse applications. The energy implications of part-load are critical, as efficiency often drops sharply as load decreases across a wide diversity of devices. To quantify the extent of this problem, we derive a dimensionless Part-Load Metric (PLM) based on device efficiency and its frequency distribution of operating hours at various output levels. The PLM quantifies the deviation of a device's actual efficiency from its maximum design efficiency. This metric also serves as a measure of "capital inefficiency," enabling engineers to compare the impact of different part-load solutions and providing a unified framework for evaluating performance across various devices and systems.

Meier, Alan

A Critical Review of Heliostat Design for Concentrating Solar Thermal Technologies

Heliostat designs have undergone a widespread and eclectic development process, with many unique designs demonstrated. However, recent developments do not show the overall cohort converging toward a globally accepted universal design. Here, this study characterizes heliostats by breaking down and evaluating design traits based on emergent patterns from a comprehensive compilation of known heliostat designs spanning several decades. Four main categories for evaluation emerged: heliostat base, heliostat primary axis, heliostat drive, and facet support. Each of these four categories is further defined by four subtypes so that all heliostats fall into a single subtype within each category. The classified heliostats are ranked, yielding several view slices into the heliostat compilation or a breakdown of heliostats by type. An analysis of the breakdown shows several trends: a scale-up of established designs, new approaches at small to medium scales, and a movement toward greater adoption of linear drives. These trends reflect the most meaningful contributing factors to a proposed trajectory for a new era of heliostat designs striving to meet widely considered cost targets of $\$$50/m 2 or $\$$75/m 2 .

14 SOLAR ENERGY

Benchmarking of ENDF/B-VIII.1 Thermal Scattering Library for Hydrogen

In correctly characterizing the energy and momentum transfer at thermal and cold energies between neutrons and its interacting medium, thermal scattering libraries, which details energy states due to the intra- and inter-molecular bond effects for the medium materials, are applied in place of free-gas cross section libraries in a particle transport simulation code. They are essential to the neutron performance of a neutron facility like SNS, where thermalized neutrons from 20 K liquid hydrogen and ambient (~300 K) water are transported to the beamlines for neutron scattering experiments in studying materials. Recently, a new version of thermal scattering library for parahydrogen and orthohydrogen at 14-20 K was developed and to be released in ENDF/B-VIII.1. It is, therefore, important to benchmark its impacts on the prediction of moderator performance due to the updates in the thermal scattering library. In this study, the recent ENDF/B-VIII.1 thermal scattering library was compared to the current ENDF/B-VII.1 one in the neutron performance calculations for the decoupled and coupled hydrogen moderators at SNS under theorized and real working conditions. In addition, the predictions using both thermal scattering libraries were benchmarked to the measurements of moderator performance. The consistency between the libraries was observed mostly for parahydrogen and the difference in orthohydrogen at cold neutron energies was noted.

Lu, Wei [Oak Ridge National Laboratory (ORNL), Oak

Final Technical Report: Transport of Complex Mixtures in Ion-Containing Polymer Membranes

Permselective ion-containing membranes are an integral component for many applications from water treatment, fuel cells, and solar fuels devices where the selective transport of molecules and ions is desired. In solar fuels devices, ion-containing polymer membranes are responsible for permitting selective transport of ions between electrodes to maintain overall charge neutrality yet limit transport of reaction products produced at the electrodes. While the transport of single solutes through such membranes has been fairly well described, binary and multicomponent transport is poorly understood due to the myriad of interactions that occur in these systems (i.e. between co-permeants and between permeants and the membrane). Solar fuels devices are just one example of an application where understanding the transport of multiple simultaneous species is critically important to improving device performance as product crossover leads to reductions in overall device performance. The objectives of this research was to improve our understanding of the complex array of factors that influence transport behavior of multiple solutes within ion-containing polymer membranes. This experimental project addressed the lack of fundamental understanding of multicomponent transport behavior by synthesizing ion exchange membranes with varied incorporation of comonomers (ionic and neutral moieties) to investigate fundamental relationships between membrane structure, membrane physiochemical properties, and transport behavior of solutes and complex solute mixtures through dense, hydrated membranes.

25 ENERGY STORAGE

Flexible and Extensive Platinum Ion Gel Condensers for Programmable Catalysis

Catalytic condensers composed of ion gels separating a metal electrode from a platinum-on-carbon active layer were fabricated and characterized to achieve more powerful, high surface area dynamic heterogeneous catalyst surfaces. Ion gels comprised of poly(vinylidene difluoride)/1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide were spin coated as a 3.8 μm film on a Au surface, after which carbon sputtering of a 1.8 nm carbon film and electron-beam evaporation of 2 nm Pt clusters created an active surface exposed to reactant gases. Electronic characterization indicated that most charge condensed within the Pt nanoclusters upon application of a potential bias, with the condenser device achieving a capacitance of ∼20 μF/cm 2 at applied frequencies of up to 120 Hz. The maximum charge of ∼10 14 |e – | cm –2 was condensed under stable device conditions at 200 °C on catalytic films with ∼10 15 sites cm –2 . Grazing incidence infrared spectroscopy measured carbon monoxide adsorption isobars, indicating a change in the CO* binding energy of ∼19 kJ mol –1 over an applied potential bias of only 1.25 V. Condensers were also fabricated on flexible, large area Kapton substrates allowing stacked or tubular form factors that facilitate high volumetric active site densities, ultimately enabling a fast and powerful catalytic condenser that can be fabricated for programmable catalysis applications.

Catalysis

Converting Second‐Order Saddle Points to Transition States: New Principles for the Design of 4π Photoswitches

Abstract Molecular photoswitches have demonstrated potential for storing solar energy at the molecular level, with power densities comparable to commercial batteries and hydroelectric energy storage. However, development of efficient photoswitches is hindered by limitations in cyclability and optical properties of existing materials. We here demonstrate that certain limitations in photoswitches based on electrocyclizations stem from the issue of controlling competition between Woodward‐Hoffmann allowed and forbidden pathways. Our approach moves beyond the traditional view of activation barriers and reveals that second‐order saddle points are crucial in dictating the competition between disrotatory and conrotatory pathways. These insights suggest new opportunities to manipulate the competition between these pathways through geometric constraints, fundamentally altering the connectivity of the potential energy surface. Our study also emphasizes the necessity of multi‐reference methods and the need to conduct higher‐dimensional explorations for competing pathways beyond photoswitch design.

Chemistry

Enhancing Charge Storage of Mo 2 Ti 2 C 3 MXene by Partial Oxidation

Abstract Driving the pseudocapacitive redox intercalation in 2DMXenes with neutral electrolytes is important for safer, more sustainable, and improved electrochemical charge storage. Single transition metal MXenes, such as Ti 3 C 2 , have shown great promise for energy storage, owing to their high conductivity and redox activity. Mixed metallic MXenes, such as out‐of‐plane ordered Mo 2 Ti 2 C 3 , have remained underexplored in energy storage because of the absence of redox activity in most of the electrolytes. Simultaneous structural modifications and instigating intercalation pseudocapacitance in neutral electrolytes could be a viable strategy for enhancing their electrochemical properties. Herein, a facile synthesis of partially oxidized Mo 2 Ti 2 C 3 MXene (PO‐Mo 2 Ti 2 C 3 ) exhibiting improved charge storage capability is demonstrated. Optical, structural, and spectroscopic analyses indicate the formation of oxide nanostructures upon thermal oxidation of Mo 2 Ti 2 C 3 . This leads to an enhanced energy storage capability with remarkably improved cyclability as well as a high Coulombic efficiency in a neutral LiCl electrolyte. This work highlights the importance of structural modifications of MXenes to enhance their charge storage and shows the promise of less explored double transition metal MXenes in energy storage.

Chemistry

Development of a high fidelity CFD model for solvent evaporation and transport in porous structure during battery electrode drying

An efficient battery manufacturing process is the key to the mass production of Electric Vehicles (EV), in which drying is one of the most energy-intensive steps significantly influencing the battery cell performance. An accurate 3D CFD model for drying is essential for predicting the drying mechanism and optimizing its parameters. By optimizing the drying process, it is possible to reduce energy consumption and cost during battery manufacturing, minimize binder loading and maximize active material loading to achieve superior electrochemical performances and facilitate wider and faster public adoption of EV. This project aims to optimize the drying process during electrode manufacturing by leveraging high-fidelity, porous electrode simulations for solvent evaporation. By optimizing this process, we seek to reduce energy consumption during battery manufacturing, while minimizing binder loading and maximizing active material loading, with the overall goal of enhancing electrical vehicle performance.

Horner, Jeffrey Scott [Sandia National Laboratorie

A fully light-driven approach to separate carbon dioxide from emission streams

Carbon capture from industrial point sources is an essential component of the global effort to mitigate climate risks. However, traditional approaches require significant energy input—often provided, counterproductively, by fossil fuel combustion. Using sunlight directly as the energy source would significantly improve the energy efficiency of carbon capture processes. Herein, we report the first fully visible-light-driven CO 2 separation system, in which carbon capture is achieved via the photoenolization/addition reaction of inexpensive 2-methylbenzophenone with CO 2 , and CO 2 release is realized through an intramolecular photodecarboxylation reaction. Finally, this system operates isothermally, works with natural sunlight, and facilitates CO 2 removal from natural gas flue emissions, providing a blueprint for other non-thermal chemical separations.

Ahmad, Bayu I. Z. [Cornell Univ., Ithaca, NY (Unit

Establishing model credibility for process-microstructure-property relationships in additive manufacturing using exascale computing

Additive Manufacturing (AM) of alloys holds significant promise as a disruptive technology in various industries, yet its adoption is often hindered by challenges in achieving consistent part quality. These issues are primarily due to the complex process-microstructure-property (PSP) relationships inherent to AM. Computational models can greatly aid in understanding these relationships, but their widespread impact and adoption has been limited by a lack of validated, open-source, and computationally efficient PSP modeling frameworks and hardware limitations. Here, this study leverages the ExaAM software suite and data from the AMBench-2018 series of laser powder bed fusion (LPBF) benchmark experiments to perform a comprehensive model assessment, including verification, validation, sensitivity analysis, and uncertainty quantification. The RADICAL-EnTK workflow manager was used to perform an ensemble of heat transport, solidification, and mechanical response simulations on the exascale computer Frontier, considering uncertainties in critical model inputs such as laser spot size and nucleation parameters, and consisting of 125 explicit grain structure simulations and 7875 crystal plasticity simulations. For a selected location within the Inconel 625 AMBench-2018 test artifact, sensitivity analysis and uncertainty quantification were performed using the predicted distributions of grain structure and mechanical properties. Qualitative agreement was found between the predicted grain size and texture and the observed AMBench-2018 microstructure, the mean predicted yield stress was within 5% of the experimental measurement mean, and the mean predicted engineering stress at 5% strain was within 10% of the experimental measurement mean. The insights gained from development and validation of the ExaAM PSP modeling framework will help guide future directions for enhancing the credibility and reliability of PSP models in AM, thereby accelerating the adoption of AM technologies in various industries.