Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Structural transition from two-dimensional ZIF-L to three-dimensional ZIF-8 nanoparticles in aqueous room temperature synthesis with improved CO2 adsorption

Highlights: • ZIF-L and ZIF-8 were synthesised with the same molar ratio of reagents (Zn{sup + 2}/Hmim = 8). • TEA threshold loading which was responsible for the phase transition was determined. • The CO{sub 2} desorption was improved due to increase of surface basicity and porosity. - Abstract: A new micron-sized leaf- two-dimensional (2D) structured zeolitic imidazolate framework (ZIF-L) and nano-sized ZIF-8 were successfully synthesised in aqueous basic solution at room temperature with the same molar ratio of reagents (Zn{sup + 2}/Hmim = 8). Both ZIFs have attracted tremendous research interest due to their wide applications including absorption, separation, and catalysis. This phase and morphology change could be tailored by changing the concentration of base-type additive triethylamine (TEA). Also, this morphology change from 2D (ZIF-L) to three-dimensional (3D) (ZIF-8) was observed by X-ray diffraction (XRD), transmission electron microscopy (TEM), field emission scanning electron microscopy (FESEM), thermogravimetric analysis (TGA), attenuated total reflectance infrared (ATR-IR) spectroscopy analysis, and surface area and pore textural properties using micromeritics gas adsorption analyser. The total amount of basic sites and carbon dioxide (CO{sub 2}) desorption capacity were also calculated using CO{sub 2} temperature-programmed desorption (CO{sub 2}-TPD) technique. Furthermore, TEA/total mole ratio of 0.0006 was proved as transition loading between two phases. Also, the particle and crystal size of samples decreased with increasing TEA/total mole ratio. The smallest ZIF-L and ZIF-8 particles obtained were 1.6 μm and 177 nm, respectively that showed excellent thermal stability. The basicity and uptakes of CO{sub 2} improved proportionally with TEA and followed this order: ZIF-8 > ZIF-L. This study provides some new insights into zeolitic imidazolate framework by controlling crystal growth and morphology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to planning target volume (PTV) margins for planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-Assembled BaTiO 3 –Au x Ag 1– x Low-Loss Hybrid Plasmonic Metamaterials with an Ordered “Nano-Domino-like” Microstructure

Metallic plasmonic hybrid nanostructures have attracted enormous research interest due to the combined physical properties coming from different material components and the broad range of applications in nanophotonic and electronic devices. However, the high loss and narrow range of property tunability of the metallic hybrid materials have limited their practical applications. In this study, a metallic alloy-based self-assembled plasmonic hybrid nanostructure, i.e., a BaTiO 3 –Au x Ag 1– x (BTO) vertically aligned nanocomposite, has been integrated by a templated growth method for low-loss plasmonic systems. Comprehensive microstructural characterizations including high-resolution scanning transmission electron microscopy (HRSTEM), energy-dispersive X-ray spectroscopy (EDS), and three-dimensional (3D) electron tomography demonstrate the formation of an ordered “nano-domino-like” morphology with Au 0.4 Ag 0.6 nanopillars as cylindrical cores and BTO as square shells. By comparing with the BTO–Au hybrid thin film, the BTO–Au 0.4 Ag 0.6 alloyed film exhibits much broader plasmon resonance, hyperbolic dispersion, low-loss, and thermally robust features in the UV–vis–NIR wavelength region. This study provides a feasible platform for a complex alloyed plasmonic hybrid material design with low-loss and highly tunable optical properties toward all-optical integrated devices.

36 MATERIALS SCIENCE↗

XPS Study of Thermally Evaporated Ge-Sb-Te Amorphous Thin Films

Amorphous thin films were prepared from the bulk composition of Ge{sub 22}Sb{sub 22}Te{sub 56}(GST) alloy by thermal evaporation in good vacuum condition. The amorphous nature of as-deposited films was checked with x-ray diffraction (XRD) studies. X-ray photoelectron spectroscopy (XPS) has been used to determine the binding energies of the core electrons in amorphous thin GST films. In XPS, we performed the survey scan from the binding energy (BE) range from 0-1100 eV and core level spectra of Ge 3d, Sb 3d and Te 3d.

36 MATERIALS SCIENCE↗

Application of a multi-beam vibrometer on industrial components

Laser Doppler vibrometry is a well proven tool for the non-contact measurement of vibration. The scanning of several measurement points allows to visualize the deflection shape of the component, ideally a 3D-operating deflection shape, if a 3-D scanner is applied. Measuring the points sequentially, however, requires stationary behavior during the measurement time. This cannot be guaranteed for many real objects. Therefore, a multipoint laser Doppler vibrometer has been developed by Polytec and the University of Stuttgart with Bosch as industrial partner. A short description of the measurement system is given. Applications for the parallel measurement of the vibration of several points are shown for non-stationary vibrating Bosch components such as power-tools or valves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-BRA-01: A Procedure for the Fast Semi-Automatic Localization of Catheters Using An Electromagnetic Tracker (EMT) for Image-Guided Brachytherapy

Purpose: To evaluate the feasibility of brachytherapy catheter localization through use of an EMT and 3D image set. Methods: A 15-catheter phantom mimicking an interstitial implantation was built and CT-scanned. Baseline catheter reconstruction was performed manually. An EMT was used to acquire the catheter coordinates in the EMT frame of reference. N user-identified catheter tips, without catheter number associations, were used to establish registration with the CT frame of reference. Two algorithms were investigated: brute-force registration (BFR), in which all possible permutation of N identified tips with the EMT tips were evaluated; and signature-based registration (SBR), in which a distance matrix was used to generate a list of matching signatures describing possible N-point matches with the registration points. Digitization error (average of the distance between corresponding EMT and baseline dwell positions; average, standard deviation, and worst-case scenario over all possible registration-point selections) and algorithm inefficiency (maximum number of rigid registrations required to find the matching fusion for all possible selections of registration points) were calculated. Results: Digitization errors on average <2 mm were observed for N ≥5, with standard deviation <2 mm for N ≥6, and worst-case scenario error <2 mm for N ≥11. Algorithm inefficiencies were: N = 5, 32,760 (BFR) and 9900 (SBR); N = 6, 360,360 (BFR) and 21,660 (SBR); N = 11, 5.45*1010 (BFR) and 12 (SBR). Conclusion: A procedure was proposed for catheter reconstruction using EMT and only requiring user identification of catheter tips without catheter localization. Digitization errors <2 mm were observed on average with 5 or more registration points, and in any scenario with 11 or more points. Inefficiency for N = 11 was 9 orders of magnitude lower for SBR than for BFR. Funding: Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

Multiscale Characterization of Structural Compositional and Textural Heterogeneity of Nano-porous Geomaterials

The purpose of the project was to perform multiscale characterization of low permeability rocks to determine the effect of physical and chemical heterogeneity on the poromechanical and flow responses of shales and carbonate rocks with a broad range of physical and chemical heterogeneity . An integrated multiscale imaging of shale and carbonate rocks from nanometer to centimeter scales include s dual focused ion beam - scanning electron microscopy (FIB - SEM) , micro computed tomography (micro - CT) , optical and confocal microscopy, and 2D and 3D energy dispersive spectroscopy (EDS). In addition, mineralogical mapping and backscattered imaging with nanoindentation testing advanced the quantitative evaluat ion of the relationship between material heterogeneity and mechanical behavior. T he spatial distribution of compositional heterogeneity, anisotropic bedding patterns, and mechanical anisotropy were employed as inputs for brittle fracture simulations using a phase field model . Comparison of experimental and numerical simulations reveal ed that proper incorporation of additional material information, such as bedding layer thickness and other geometrical attributes of the microstructures, can yield improvements on the numerical prediction of the mesoscale fracture patterns and hence the macroscopic effective toughness. Overall, a comprehensive framework to evaluate the relationship between mechanical response and micro-lithofacial features can allow us to make more accurate prediction of reservoir performance by developing a multi - scale understanding of poromechanical response to coupled chemical and mechanical interactions for subsurface energy related activities.

36 MATERIALS SCIENCE↗

High mass resolution, high angular acceptance time-of-flight mass spectroscopy for planetary missions under the Planetary Instrument Definition and Development Program (PIDDP)

This final report covers three years and several phases of work in which instrumentation for the Planetary Instrument Definition and Development Program (PIDDP) were successfully developed. There were two main thrusts to this research: (1) to develop and test methods for electrostatically scanning detector field-of-views, and (2) to improve the mass resolution of plasma mass spectrometers to M/delta M approximately 25, their field-of-view (FOV) to 360 degrees, and their E-range to cover approximately 1 eV to 50 keV. Prototypes of two different approaches to electrostatic scanning were built and tested. The Isochronous time-of-flight (TOF) and the linear electric field 3D TOF devices were examined.

Young, David T.↗

Open Ocean and Landfalling Hurricane Directional Wave Spectra from a Scanning Radar Altimeter

The sea surface directional wave spectrum was measured for the first time in all quadrants of a hurricane in open water using the NASA airborne scanning radar altimeter (SRA) carried aboard one of the National Oceanic and Atmospheric Administration (NOAA) WP-3D hurricane research aircraft at 1.5 km height. The open-ocean data were acquired on 24 August 1998 when Bonnie, a large category 3 hurricane, was east of the Bahamas and moving about 5 meters per second toward 330. The NOAA aircraft spent over five hours within 180 km of the hurricane Bonnie eye and made five eye penetrations. Individual waves with heights up to 18 m were observed and the spatial variation of the wave field was dramatic. The dominant waves generally propagated at significant angles to the downwind direction. At some positions there were three different wave fields of comparable energy crossing each other. On 26 August 1998, the SRA documented the wave spectrum spatial variation while Bonnie was making landfall near Wilmington, NC.

Wright, C. Wayne↗

Correlations Among Microstructure, Morphology, Chemistry, and Isotopic Systematics of Hibonite in CM Chondrites

Introduction: Hibonite is a primary refractory phase occurring in many CAIs, typically with spinel and perovskite. Our microstructural studies of CAIs from carbonaceous chondrites reveal a range of stacking defect densities and correlated non-stoichiometry in hibonite. We also conducted a series of annealing experiments, demonstrating that the Mg-Al substitution stabilized the formation of defect-structured hibonite. Here, we continue a detailed TEM analysis of hibonite-bearing inclusions from CM chondrites that have been well-characterized isotopically. We examine possible correlations of microstructure, morphology, mineralogy, and chemical and isotopic systematics of CM hibonites in order to better understand the formation history of hibonite in the early solar nebula. Methods: Fifteen hibonite-bearing inclusions from the Paris CM chondrite were analyzed using a JEOL 7600F SEM and a JEOL 8530F electron microprobe. In addition to three hibonite-bearing inclusions from the Murchison CM chondrite previously reported, we selected three inclusions from Paris, Pmt1-6, 1-9, and 1-10, representing a range of 26Al/27Al ratios and minor element concentrations for a detailed TEM study. We extracted TEM sections from hibonite grains using a FEI Quanta 3D field emission gun SEM/FIB. The sections were then examined using a JEOL 2500SE field-emission scanning TEM equipped with a Thermo-Noran thin window EDX spectrometer. Results and Discussion: A total of six hibonite-bearing inclusions, including two platy hibonite crystals (PLACs) and four spinel-hibonite inclusions (SHIBs), were studied. There are notable differences in chemical and isotopic compositions between the inclusions (Table 1), indicative of their different formation environment or timing. Our TEM observations show perfectly-ordered, stoichiometric hibonite crystals without stacking defects in two PLACs, 2-7-1 and 2-8-2, and in three SHIBs, Pmt1-6, 1-9, and 1-10. In contrast, SHIB 1-9-5 hibonite grains contain a low density of stacking defects linked to an increase in MgO contents, indicating complex, disordered intergrowths of stoichiometric and MgO-enriched hibonites. From the data collected to date, we find no clear correlation between the microstructures of hibonite and its morphological and mineralogical types that reflect distinct chemical and isotopic systematics [6-8,10]. Interestingly, the presence of no or few stacking defects in hibonite from the PLACs and SHIBs are in contrast to our experimental studies that produced very high densities of stacking defects in hibonite [3-5]. Unlike our experi-ments, electron microprobe data from the PLACs and SHIBs hibonite grains show a strong correlation between (Ti4++Si4+) and Mg2+ cations, suggesting that coupled substitutions of (Ti4++Mg2+) and (Si4++Mg2+) for 2Al3+ inhibit the formation of defect-structured hibonite. However, our experimental studies suggest that kinetics (e.g., cooling rate) or other thermal effects also exert a strong control on the microstructures and chemical compositions of hibonite. In Pmt1-6, elongated perovskite grains present at the hibonite grain boundaries display (121) twinning, indicative of a fast cooling (>50degC/min) after high-temperature events. Therefore, the nebular microstructural characteristics of hibonite, at least in this inclusion, would not have destroyed by subsequent high-temperature annealing. Conclusions: Our TEM observations thus far show no clear correlation in microstructures, morphological and mineralogical characteristics, and chemical and isotopic systematics of hibonites from CM chondrites. The observed variation in stacking defect densities in the hibonites may be controlled by thermal processes in the early solar nebula. A detailed TEM analysis of additional CM hibonite samples is underway to evaluate this hypothesis.

Han, J.↗

Characterizing Char Rate and Extent in Fiber-Reinforced Plastics Using X-ray Computed Tomography

Orbital debris is a growing problem for the space industry and the world in general, and an important component of the problem is what happens when that debris reenters the Earth’s atmosphere. With more spacecraft opting for fiber-reinforced polymer (FRP) components, we need to understand the thermal destruction process of these materials during an atmospheric reentry and how much of the material can survive to impact the ground. The NASA Orbital Debris Program Office (ODPO) has developed a new charring model for FRP components to be integrated into the latest version of the Object Reentry Survival Analysis Tool (ORSAT). To validate this new model, the ODPO performed several test series using the Inductively Coupled Plasma (ICP) Torch facility at UT Austin. To measure the extent of charred material at different conditions, some of the test samples were scanned using x-ray computed tomography (CT) by the Astromaterials Curation Lab at Johnson Space Center. 3D image analysis was then used to calculate the volume and density of the char in each test sample. This paper presents the image analysis methodology, an assessment of the accuracy of the data analysis, and a comparison with calculations using the ORSAT charring model.

Benton Greene↗

Automated quantitative 3D analysis of aorta size, morphology, and mural calcification distributions

Purpose: The purpose of this work is to develop a fully automated pipeline to compute aorta morphology and calcification measures in large cohorts of CT scans that can be used to investigate the potential of these measures as imaging biomarkers of cardiovascular disease. Methods: The first step of the automated pipeline is aorta segmentation. The algorithm the authors propose first detects an initial aorta boundary by exploiting cross-sectional circularity of aorta in axial slices and aortic arch in reformatted oblique slices. This boundary is then refined by a 3D level-set segmentation that evolves the boundary to the location of nearby edges. The authors then detect the aortic calcifications with thresholding and filter out the false positive regions due to nearby high intensity structures based on their anatomical location. The authors extract the centerline and oblique cross sections of the segmented aortas and compute the aorta morphology and calcification measures of the first 2500 subjects from COPDGene study. These measures include volume and number of calcified plaques and measures of vessel morphology such as average cross-sectional area, tortuosity, and arch width. Results: The authors computed the agreement between the algorithm and expert segmentations on 45 CT scans and obtained a closest point mean error of 0.62 ± 0.09 mm and a Dice coefficient of 0.92 ± 0.01. The calcification detection algorithm resulted in an improved true positive detection rate of 0.96 compared to previous work. The measurements of aorta size agreed with the measurements reported in previous work. The initial results showed associations of aorta morphology with calcification and with aging. These results may indicate aorta stiffening and unwrapping with calcification and aging. Conclusions: The authors have developed an objective tool to assess aorta morphology and aortic calcium plaques on CT scans that may be used to provide information about the presence of cardiovascular disease and its clinical impact in smokers.

60 APPLIED LIFE SCIENCES↗

Application of Radon Transform to Multi-Angle Measurements Made by the Research Scanning Polarimeter: A New Approach to Cloud Tomography. Part I: Theory and Tests on Simulated Data.

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP was a prototype for the Aerosol Polarimetry Sensor (APS) launched on-board the NASA Glory satellite. Currently the retrieval algorithms developed for the RSP are being adopted for the measurements of the space-borne polarimeters on the upcoming NASA’s Plankton, Aerosol, Cloud Ocean Ecosystem (PACE)satellite mission. The RSP’s uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid water cloud droplet sizes using the polarized rainbow structure. It also provides geometric constraints on the cumulus cloud’s 2D cross section yielding the cloud’s geometric shape estimates. In this study we further build on the latter technique to develop a new tomographic approach to retrieval of cloud internal structure from remote sensing measurements. While tomography in the strict definition is a technique based on active measurements yielding a tomogram (directional optical thickness as a function of angle and offset of the view ray), we developed a “semi-tomographic” approach in which tomogram of the cloud is estimated from passive observations instead of being measured directly. This tomogram is then converted into 2D spatial distribution of the extinction coefficient using inverse Radon transform (filtered back projection) which is the standard tomographic procedure used e.g., in medical CT scans. This algorithm is computationally inexpensive compared to techniques relying on highly-multi-dimensional least-square fitting; it does not require iterative 3D RT simulations. The resulting extinction distribution is defined up to an unknown constant factor, so we discuss the ways to calibrate it using additional independent measurements. In the next step we use the profile of the droplet size distribution parameters from the cloud’s side (derived by fitting the polarized rainbows) to convert the 2D extinction distribution into that of the droplet number concentration. We illustrate and validate the proposed technique using 3D-RT-simulatedRSP observations of a LES-generated Cu cloud. Quantitative comparisons between the retrieved and the original optical and microphysical parameters are presented.

clouds↗

Three-dimensional nanoscale reduced-angle ptycho-tomographic imaging with deep learning (RAPID)

X-ray ptychographic tomography is a nondestructive method for three dimensional (3D) imaging with nanometer-sized resolvable features. The size of the volume that can be imaged is almost arbitrary, limited only by the penetration depth and the available scanning time. Here we present a method that rapidly accelerates the imaging operation over a given volume through acquiring a limited set of data via large angular reduction and compensating for the resulting ill-posedness through deeply learned priors. The proposed 3D reconstruction method “RAPID” relies initially on a subset of the object measured with the nominal number of required illumination angles and treats the reconstructions from the conventional two-step approach as ground truth. It is then trained to reproduce equal fidelity from much fewer angles. After training, it performs with similar fidelity on the hitherto unexamined portions of the object, previously not shown during training, with a limited set of acquisitions. In our experimental demonstration, the nominal number of angles was 349 and the reduced number of angles was 21, resulting in a x140 aggregate speedup over a volume of 4.48 x 93.18 x 3.92 μm 3 and with (14nm) 3 feature size, i.e. ~ 10 8 voxels. RAPID’s key distinguishing feature over earlier attempts is the incorporation of atrous spatial pyramid pooling modules into the deep neural network framework in an anisotropic way. We found that adjusting the atrous rate improves reconstruction fidelity because it expands the convolutional kernels’ range to match the physics of multi-slice ptychography without significantly increasing the number of parameters.

47 OTHER INSTRUMENTATION↗

A method for modeling laterally asymmetric proton beamlets resulting from collimation

Purpose: To introduce a method to model the 3D dose distribution of laterally asymmetric proton beamlets resulting from collimation. The model enables rapid beamlet calculation for spot scanning (SS) delivery using a novel penumbra-reducing dynamic collimation system (DCS) with two pairs of trimmers oriented perpendicular to each other. Methods: Trimmed beamlet dose distributions in water were simulated with MCNPX and the collimating effects noted in the simulations were validated by experimental measurement. The simulated beamlets were modeled analytically using integral depth dose curves along with an asymmetric Gaussian function to represent fluence in the beam’s eye view (BEV). The BEV parameters consisted of Gaussian standard deviations (sigmas) along each primary axis (σ{sub x1},σ{sub x2},σ{sub y1},σ{sub y2}) together with the spatial location of the maximum dose (μ{sub x},μ{sub y}). Percent depth dose variation with trimmer position was accounted for with a depth-dependent correction function. Beamlet growth with depth was accounted for by combining the in-air divergence with Hong’s fit of the Highland approximation along each axis in the BEV. Results: The beamlet model showed excellent agreement with the Monte Carlo simulation data used as a benchmark. The overall passing rate for a 3D gamma test with 3%/3 mm passing criteria was 96.1% between the analytical model and Monte Carlo data in an example treatment plan. Conclusions: The analytical model is capable of accurately representing individual asymmetric beamlets resulting from use of the DCS. This method enables integration of the DCS into a treatment planning system to perform dose computation in patient datasets. The method could be generalized for use with any SS collimation system in which blades, leaves, or trimmers are used to laterally sharpen beamlets.

07 ISOTOPE AND RADIATION SOURCES↗

Atomic resolution imaging of oxidation states in manganites.

Aberration corrected electron optics allow routine acquisition of high-spatial resolution spectroscopic images in the scanning transmission electron microscope, which is important when trying to understand the physics of transition metal oxides such as manganites. The physical properties of these perovskites are intimately related to the occupancies of the partially filled 3d bands, which define their oxidation state. In this work, we review the procedures to measure this electronic property in LaxCa1-xMnO3 from electron energy loss spectra obtained in the aberration corrected scanning transmission electron microscope. In bulk samples, several features of both the average Mn L2,3 edge and the O K edge fine structures change linearly with Mn nominal valence. These linear correlations are extracted and used as a calibration to quantify oxidation states from atomic resolution images. In such images, the same fine structure features exhibit further changes, commensurate with the underlying atomic lattice. Mn valence values calculated from those images show unexpected oscillations with the period of the atomic lattice. The combination of experiment with density-functional theory and dynamical scattering simulations allows detailed interpretation of these maps, distinguishing dynamical scattering effects from actual changes in electronic properties related to the local atomic structure.

36 MATERIALS SCIENCE↗

LABQ3: Bayesian method for quantification of mineral compositions and nano-scale elemental mapping of 3D synchrotron XCT data

Quantitative analysis of mineral compositions is essential in understanding geochemical, mineralogical and environmental processes. Fine-resolution 3D imaging is widely done using synchrotron X-ray computed tomography (XCT), but existing analyses are limited to visualization and segmentation. This paper presents a new method, Linear Attenuation Bayesian Quantitative 3D-mapper (LABQ3), based on the linearity of X-ray attenuation with respect to elemental concentrations. To address the random variability in attenuation measurements, LABQ3 employs Bayesian decision theory to minimize classification error, using reference attenuation distributions from scans of pure mineral standards. To demonstrate LABQ3 and test its performance, we studied precipitated carbonate samples. XCT scans were done at multiple energies using the transmission X-ray microscope (TXM) at beamline 32-ID-C of the Advanced Photon Source at Argonne National Laboratory. The reconstructed 3D images have a voxel size of 20 nm. Analyses revealed rich nano-scale compositional heterogeneity within individual particles. A mixture of calcium and cadmium produced an overall stoichiometric composition of (Ca 0.78 ,Cd 0.22 )CO 3 , with some voxels containing nearly pure CdCO 3 . The addition of zinc led to an overall stoichiometric composition of 33% Ca, 28% Cd, 39% Zn, with a nearly pure CaCO 3 core and compositional zonation through the rim. These compositional gradients are related to temporal sequences of carbonate mineral formation where Cd precipitated at the beginning in (Ca,Cd)CO 3 , while Cd and Zn precipitated at the end in (Ca, Cd,Zn)CO 3 . Results differ from bulk analyses using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), showing that LABQ3 provides particle-specific insights. LABQ3 distinguishes itself by quantifying chemical compositions along a continuum, making it different from XCT analyses based on segmentation. LABQ3 allows simultaneous acquisition of morphology and chemical composition in 3D, facilitating the interpretation of chemical gradients of trace elements, quantification of solid solution compositions, inferences about temporal sequences of mineral precipitation, and addressing other concerns about solid-phase chemistry.

58 GEOSCIENCES↗

Postoperative Proton Radiotherapy for Localized and Locoregional Breast Cancer: Potential for Clinically Relevant Improvements?

Purpose: To study the potential reduction of dose to organs at risk (OARs) with intensity-modulated proton radiotherapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) photon radiotherapy for left-sided breast cancer patients. Methods and Materials: Comparative treatment-planning was performed using planning computed tomography scans of 20 left-sided breast cancer patients. For each patient, three increasingly complex locoregional volumes (planning target volumes [PTVs]) were defined: whole breast (WB) or chest wall (CW) = (PTV1), WB/CW plus medial-supraclavicular (MSC), lateral-supraclavicular (LSC), and level III axillary (AxIII) nodes = (PTV2) and WB/CW+MSC+LSC+AxIII plus internal mammary chain = (PTV3). For each patient, 3D-CRT, IMRT, and IMPT plans were optimized for PTV coverage. Dose to OARs was compared while maintaining target coverage. Results: All the techniques met the required PTV coverage except the 3D-CRT plans for PTV3-scenario. All 3D-CRT plans for PTV3 exceeded left-lung V20. IMPT vs. 3D-CRT: significant dose reductions were observed for all OARs using IMPT for all PTVs. IMPT vs. IMRT: For PTV2 and PTV3, low (V5) left lung and cardiac doses were reduced by a factor >2.5, and cardiac doses (V22.5) were by a factor of >20 lower with IMPT compared with IMRT. Conclusions: When complex-target irradiation is needed, 3D-CRT often compromises the target coverage and increases the dose to OARs; IMRT can provide better results but will increase the integral dose. The benefit of IMPT is based on improved target coverage and reduction of low doses to OARs, potentially reducing the risk of late-toxicity. These results indicate a potential role of proton-radiotherapy for extended locoregional irradiation in left breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗