Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

The LeRC rail accelerators: Test designs and diagnostic techniques

The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed.

Zana, L. M.↗

LeRC rail accelerators - Test designs and diagnostic techniques

The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed. Previously announced in STAR as N83-35053

Zana, L. M.↗

Modeling of Particle Acceleration at Multiple Shocks via Diffusive Shock Acceleration: Preliminary Results

Successful forecasting of energetic particle events in space weather models require algorithms for correctly predicting the spectrum of ions accelerated from a background population of charged particles. We present preliminary results from a model that diffusively accelerates particles at multiple shocks. Our basic approach is related to box models in which a distribution of particles is diffusively accelerated inside the box while simultaneously experiencing decompression through adiabatic expansion and losses from the convection and diffusion of particles outside the box. We adiabatically decompress the accelerated particle distribution between each shock by either the method explored in Melrose and Pope (1993) and Pope and Melrose (1994) or by the approach set forth in Zank et al. (2000) where we solve the transport equation by a method analogous to operator splitting. The second method incorporates the additional loss terms of convection and diffusion and allows for the use of a variable time between shocks. We use a maximum injection energy (E(sub max)) appropriate for quasi-parallel and quasi-perpendicular shocks and provide a preliminary application of the diffusive acceleration of particles by multiple shocks with frequencies appropriate for solar maximum (i.e., a non-Markovian process).

Parker, L. Neergaard↗

Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT

Purpose: In this work, the feasibility of implementing a motion-perturbation approach to accurately estimate volumetric dose in the presence of organ motion—previously demonstrated for VMAT-–is studied for static gantry IMRT. The method's accuracy is improved for the voxels that have very low planned dose but acquire appreciable dose due to motion. The study describes the modified algorithm and its experimental validation and provides an example of a clinical application. Methods: A contoured region-of-interest is propagated according to the predefined motion kernel throughout time-resolved 4D phantom dose grids. This timed series of 3D dose grids is produced by the measurement-guided dose reconstruction algorithm, based on an irradiation of a staticARCCHECK (AC) helical dosimeter array (Sun Nuclear Corp., Melbourne, FL). Each moving voxel collects dose over the dynamic simulation. The difference in dose-to-moving voxel vs dose-to-static voxel in-phantom forms the basis of a motion perturbation correction that is applied to the corresponding voxel in the patient dataset. A new method to synchronize the accelerator and dosimeter clocks, applicable to fixed-gantry IMRT, was developed. Refinements to the algorithm account for the excursion of low dose voxels into high dose regions, causing appreciable dose increase due to motion (LDVE correction). For experimental validation, four plans using TG-119 structure sets and objectives were produced using segmented IMRT direct machine parameters optimization in Pinnacle treatment planning system (v. 9.6, Philips Radiation Oncology Systems, Fitchburg, WI). All beams were delivered with the gantry angle of 0°. Each beam was delivered three times: (1) to the static AC centered on the room lasers; (2) to a static phantom containing a MAPCHECK2 (MC2) planar diode array dosimeter (Sun Nuclear); and (3) to the moving MC2 phantom. The motion trajectory was an ellipse in the IEC XY plane, with 3 and 1.5 cm axes. The period was 5 s, with the resulting average motion speed of 1.45 cm/s. The motion-perturbed high resolution (2 mm voxel) volumetric dose grids on the MC2 phantom were generated for each beam. From each grid, a coronal dose plane at the detector level was extracted and compared to the corresponding moving MC2 measurement, using gamma analysis with both global (G) and local (L) dose-error normalization. Results: Using the TG-119 criteria of (3%G/3 mm), per beam average gamma analysis passing rates exceeded 95% in all cases. No individual beam had a passing rate below 91%. LDVE correction eliminated systematic disagreement patterns at the beams’ aperture edges. In a representative example, application of LDVE correction improved (2%L/2 mm) gamma analysis passing rate for an IMRT beam from 74% to 98%. Conclusions: The effect of motion on the moving region-of-interest IMRT dose can be estimated with a standard, static phantom QA measurement, provided the motion characteristics are independently known from 4D CT or otherwise. The motion-perturbed absolute dose estimates were validated by the direct planar diode array measurements, and were found to reliably agree with them in a homogeneous phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flying focus with arbitrary directionality for spatiotemporal control of laser intensity

Flying focus techniques produce laser pulses whose focal points travel at arbitrary, controllable velocities. While this flexibility can enhance a broad range of laser-based applications, existing techniques constrain the motion of the focal point to the propagation direction of the pulse. Here, we introduce a flying focus configuration that decouples the motion of the focus from the propagation direction. Here, a chirped laser pulse focused and diffracted by a diffractive lens and grating creates a focal point that can move both along and transverse to the propagation direction. The focal length of the lens, grating period, and chirp can be tuned to control the direction and velocity of the focus. Simulations demonstrate this control for a holographic configuration suited to high-power pulses, in which two off-axis pump beams with different focal lengths encode the equivalent phase of a chromatic lens and grating in a gas or plasma. For low-power pulses, conventional solid-state or adaptive optics can be used instead. Multi-dimensional control over the focal trajectory enables new configurations for applications, including laser wakefield acceleration of ions, nonlinear Thomson scattering, and surface-plasmon emission of THz radiation.

Classical optics↗

Power Grid Computational Challenges and Metrics for Hardware Accelerator Evaluation

The objective of this document is to support the DMC initiative’s research on hardware and software development. Our focus is on the power grid domain that has a rich diversity of numerical and computationally challenging applications. Through this document, we highlight two core building blocks, power flow, and transient stability equations, for power grid applications. Improving computational robustness and acceleration of these core blocks will tremendously benefit all power grid applications. We also highlight the most computationally dominant numerical kernels that are being used in power flow and transient stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of Particle Acceleration at Multiple Shocks Via Diffusive Shock Acceleration: Preliminary Results

We present preliminary results from a model that diffusively accelerates particles at multiple shocks. Our basic approach is related to box models (Protheroe and Stanev, 1998; Moraal and Axford, 1983; Ball and Kirk, 1992; Drury et al., 1999) in which a distribution of particles is diffusively accelerated inside the box while simultaneously experiencing decompression through adiabatic expansion and losses from the convection and diffusion of particles outside the box (Melrose and Pope, 1993; Zank et al., 2000). We adiabatically decompress the accelerated particle distribution between each shock by either the method explored in Melrose and Pope (1993) and Pope and Melrose (1994) or by the approach set forth in Zank et al. (2000) where we solve the transport equation by a method analogous to operator splitting. The second method incorporates the additional loss terms of convection and diffusion and allows for the use of a variable time between shocks. We use a maximum injection energy (Emax) appropriate for quasi-parallel and quasi-perpendicular shocks (Zank et al., 2000, 2006; Dosch and Shalchi, 2010) and provide a preliminary application of the diffusive acceleration of particles by multiple shocks with frequencies appropriate for solar maximum (i.e., a non-Markovian process).

Parker, Linda Neergaard↗

From Atoms to Wheels: The Role of Multi-Scale Modeling in the Future of Transportation Electrification

Traditionally, prototype hardware is built for validation testing to ensure battery systems design changes meet vehicle-level requirements, which is expensive both in cost and time. Virtual engineering (VE) of battery systems for electric vehicle (EV) propulsion offers a reduced-cost alternative to the traditional development process and uses multi-scale modeling to virtually probe the impact of design changes in a particular part on the overall performance of the system. This allows for rapid iteration over multiple design spaces, without committing to build hardware. This perspective article discusses current trends in VE for EV applications and proposes improvements to accelerate EV adoption.

Garrick, Taylor R. (ORCID:0000000322518129)↗

Particle energization during solar maximum: Diffusive shock acceleration at multiple shocks

We present a model for the acceleration of particles at multiple shocks using an approach related to box models. A distribution of particles is diffusively accelerated inside the box while simultaneously experiencing decompression through adiabatic expansion and losses from the convection and diffusion of particles out of the box by either the method used in Melrose and Pope and Pope and Melrose or by the approach introduced in Zank et al. where we solve the transport equation by a method analogous to operator splitting. The second method incorporates the additional loss terms of convection and diffusion and allows for the use of a variable time between shocks. We use a maximum injection energy (E{sub max}) appropriate for quasi-parallel and quasi-perpendicular shocks. We provide a preliminary application of the diffusive acceleration of particles by multiple shocks with frequencies appropriate for solar maximum.

79 ASTRONOMY AND ASTROPHYSICS↗

The application of multi-wire drift chambers in cosmic ray research

Multiwire drift chambers designed for the neutrino experiment at the IHEP U-70 accelerator have found a new application in the MEPhI experiment focused on the detection of ultrahigh-energy cosmic rays. Their high durability and fine spatial and angular characteristics make these chambers perfectly suitable for such studies. The drift chambers were tested at MEPhI and used in constructing the CTUDC coordinatetracking setup, which operated together with the NEVOD water Cherenkov detector and the DECOR detector. The results of the studies of the parameters of drift chambers in the cosmic-ray flux at test benches and in the CTUDC setup are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of electron beam technology to decompose persistent emerging drinking water contaminants: poly- and perfluoroalkyl substances (PFAS) and 1,4 dioxane.

Fermi Research Alliance, LLC (FRA) operates Fermilab under contract with the U.S. Department of Energy and has patents on technologies and applications of a novel mobile electron beam accelerator. A high-power version of this mobile accelerator based on FRA-developed SRF technology is under development at Illinois Accelerator Research Center (IARC) and can enable several new applications that have significant commercial potential. One such application is the e-beam treatment of persistent emerging contaminants in drinking water. The contaminants of concern are poly- and perfluoroalklyl substances (PFAS) and 1,4-dioxine. Both PFAS and 1,4-D are highly resistant to degradation and are not effectively removed by conventional drinking water treatment systems. Existing technologies, such as granular activated carbon (GAC) filters and reverse osmosis (RO) systems do not decompose. The Center for Clean Water Technology (CCWT) at Stony Brook University (SBU) is in the process of identifying and testing effective technologies to remove PFAS and/or 1,4-D from drinking waters. se PFAS, but rather concentrate them either by adsorption (GAC) or membrane rejection (RO). The Center for Clean Water Technology (CCWT) at Stony Brook University (SBU) is in the process of identifying and testing effective technologies to remove PFAS and/or 1,4-D from drinking waters to demonstrate the full-scale application of novel water treatment technologies and is experienced in conducting research to understand treatment performance with a particular focus on 1,4-D and PFAS contamination.

43 PARTICLE ACCELERATORS↗

Computational screening of organic polymer dielectrics for novel accelerator technologies

The use of infrared lasers to power accelerating dielectric structures is a developing area of research. Within this technology, the choice of the dielectric material forming the accelerating structures, such as the photonic band gap (PBG) structures, is dictated by a range of interrelated factors including their dielectric and optical properties, amenability to photo-polymerization, thermochemical stability and other target performance metrics of the particle accelerator. In this direction, electronic structure theory aided computational screening and design of dielectric materials can play a key role in identifying potential candidate materials with the targeted functionalities to guide experimental synthetic efforts. In an attempt to systematically understand the role of chemistry in controlling the electronic structure and dielectric properties of organic polymeric materials, here we employ empirical screening and density functional theory (DFT) computations, as a part of our multi-step hierarchal screening strategy. Our DFT based analysis focused on the bandgap, dielectric permittivity, and frequency-dependent dielectric losses due to lattice absorption as key properties to down-select promising polymer motifs. In addition to the specific application of dielectric laser acceleration, the general methodology presented here is deemed to be valuable in the design of new insulators with an attractive combination of dielectric properties.

47 OTHER INSTRUMENTATION↗

SU-E-I-37: Low-Dose Real-Time Region-Of-Interest X-Ray Fluoroscopic Imaging with a GPU-Accelerated Spatially Different Bilateral Filtering

Purpose: The purpose of our study is to reduce imaging radiation dose while maintaining image quality of region of interest (ROI) in X-ray fluoroscopy. A low-dose real-time ROI fluoroscopic imaging technique which includes graphics-processing-unit- (GPU-) accelerated image processing for brightness compensation and noise filtering was developed in this study. Methods: In our ROI fluoroscopic imaging, a copper filter is placed in front of the X-ray tube. The filter contains a round aperture to reduce radiation dose to outside of the aperture. To equalize the brightness difference between inner and outer ROI regions, brightness compensation was performed by use of a simple weighting method that applies selectively to the inner ROI, the outer ROI, and the boundary zone. A bilateral filtering was applied to the images to reduce relatively high noise in the outer ROI images. To speed up the calculation of our technique for real-time application, the GPU-acceleration was applied to the image processing algorithm. We performed a dosimetric measurement using an ion-chamber dosimeter to evaluate the amount of radiation dose reduction. The reduction of calculation time compared to a CPU-only computation was also measured, and the assessment of image quality in terms of image noise and spatial resolution was conducted. Results: More than 80% of dose was reduced by use of the ROI filter. The reduction rate depended on the thickness of the filter and the size of ROI aperture. The image noise outside the ROI was remarkably reduced by the bilateral filtering technique. The computation time for processing each frame image was reduced from 3.43 seconds with single CPU to 9.85 milliseconds with GPU-acceleration. Conclusion: The proposed technique for X-ray fluoroscopy can substantially reduce imaging radiation dose to the patient while maintaining image quality particularly in the ROI region in real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Petawatt laser absorption bounded

Here, the interaction of petawatt (10 15 W) lasers with solid matter forms the basis for advanced scientific applications such as table-top particle accelerators, ultrafast imaging systems and laser fusion. Key metrics for these applications relate to absorption, yet conditions in this regime are so nonlinear that it is often impossible to know the fraction of absorbed light f, and even the range of f is unknown. Here using a relativistic Rankine-Hugoniot-like analysis, we show for the first time that f exhibits a theoretical maximum and minimum. These bounds constrain nonlinear absorption mechanisms across the petawatt regime, forbidding high absorption values at low laser power and low absorption values at high laser power. For applications needing to circumvent the absorption bounds, these results will accelerate a shift from solid targets, towards structured and multilayer targets, and lead the development of new materials.

47 OTHER INSTRUMENTATION↗

Application of laser-driven capacitor-coil to target normal sheath acceleration

A laser-driven accelerator generates protons with tens of MeV in energy by a compact, strong, and transient accelerating electric field produced as a result of laser–plasma interactions at relativistic intensities. In previous studies, two- and three-dimensional particle-in-cell simulations revealed that the application of a kT-level axial magnetic field results in an enhancement of proton acceleration via the target normal sheath acceleration mechanism due to reduced lateral electron divergence and improved electron heating efficiency. An experimental investigation of this scheme on the GEKKO-XII and the LFEX facilities found that the number and maximum energy of the accelerated protons decreased with increasing the temporal delay between the pulse driving the external magnetic-field and the pulse accelerating the protons, contrary to the theoretical and numerical expectations. Finally, we identify sources responsible for the degradation of the proton beam performance and we propose an alternative experimental setup to mitigate the degradation in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron lenses: historical overview and outlook

The first electron lenses — understood as "lenses made of electrons" rather than "lenses to focus electrons" — were envisioned in the mid-1990s and built in the early 2000s for compensation of beam-beam effects in the Tevatron proton-antiproton collider. Since then, the lenses — a novel instrument for high-energy particle accelerators — have been added to the toolbox of modern beam facilities, being particularly useful for the energy frontier superconducting hadron colliders ("supercolliders"). In this article we briefly present the history of ideas and developments toward effective use of low-energy high-current bright electron beams in high energy accelerators and discuss the promise of their future applications.

43 PARTICLE ACCELERATORS↗

Electrically Accelerated Mechanochemical Film Formation by a Phosphonium Phosphate Ionic Liquid: An In Situ Chemical Kinetics Investigation

Powertrains in electric vehicles are exposed to stray currents that accelerate wear and cause failure of mechanical components. These durability issues are further aggravated when using low-viscosity lubricants, which are desired for energy efficiency but create harsher contact conditions at sliding interfaces. This study investigates a phosphonium phosphate ionic liquid as a performance-enhancing additive in a low-viscosity base oil for lubricating electrified sliding interfaces. Ionic liquids can adsorb and react on contact interfaces via stress-assisted chemical reactions, generating nanometric tribofilms that provide protection against wear. However, the effect of electric fields on the mechanochemistry of ionic liquids is poorly understood, hindering their adoption in lubricants for electrified powertrains. This article reports an in situ optical interferometry study of ionic liquid derived tribofilm growth kinetics at stressed sliding/rolling interfaces under direct currents. The application of electric currents accelerated tribofilm formation up to a critical current density (∼1.4 A/mm 2 ), beyond which pitting-induced wear dominated. The tribofilms were composed of iron phosphates, iron oxides, and carbon species, with iron oxides becoming predominant under applied currents. These tribofilms prevented the scuffing failure of steel surfaces under electrified conditions. Based on the results, a kinetic model is proposed that integrates electric current effect into the classical stress-assisted thermal activation framework to allow prediction of tribofilm growth at electrified sliding contacts. This framework provides crucial guidance for designing next-generation lubricants for electrified transportation and power generation systems.

additives↗

Improving the Effectiveness of Burst Buffers for Big Data Processing in HPC Systems with Eley

Here, burst buffer is an effective solution for reducing the data transfer time and the I/O interference in HPC systems. Extending Burst Buffers (BBs) to handle Big Data applications is challenging because BBs must account for the large data inputs of Big Data applications and the Quality-of-Service (QoS) of HPC applications which are considered as first-class citizens in HPC systems. Existing BBs focus on only intermediate data of Big Data applications and incur a high performance degradation of both Big Data and HPC applications. We present Eley , a burst buffer solution that helps to accelerate the performance of Big Data applications while guaranteeing the QoS of HPC applications. To achieve this goal, Eley embraces interference-aware prefetching technique that makes reading data input faster while introducing low interference for HPC applications. Evaluations using a wide range of Big Data and HPC applications demonstrate that Eley improves the performance of Big Data applications by up to 30% compared to existing BBs while maintaining the QoS of HPC applications.

97 MATHEMATICS AND COMPUTING↗