Search NASA⌕ Search

SEARCH · Search NASA

Results for “Angular dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Characterization of a novel two dimensional diode array the ''magic plate'' as a radiation detector for radiation therapy treatment

Purpose: Intensity modulated radiation therapy (IMRT) utilizes the technology of multileaf collimators to deliver highly modulated and complex radiation treatment. Dosimetric verification of the IMRT treatment requires the verification of the delivered dose distribution. Two dimensional ion chamber or diode arrays are gaining popularity as a dosimeter of choice due to their real time feedback compared to film dosimetry. This paper describes the characterization of a novel 2D diode array, which has been named the ''magic plate'' (MP). It was designed to function as a 2D transmission detector as well as a planar detector for dose distribution measurements in a solid water phantom for the dosimetric verification of IMRT treatment delivery. Methods: The prototype MP is an 11 x 11 detector array based on thin (50 {mu}m) epitaxial diode technology mounted on a 0.6 mm thick Kapton substrate using a proprietary ''drop-in'' technology developed by the Centre for Medical Radiation Physics, University of Wollongong. A full characterization of the detector was performed, including radiation damage study, dose per pulse effect, percent depth dose comparison with CC13 ion chamber and build up characteristics with a parallel plane ion chamber measurements, dose linearity, energy response and angular response. Results: Postirradiated magic plate diodes showed a reproducibility of 2.1%. The MP dose per pulse response decreased at higher dose rates while at lower dose rates the MP appears to be dose rate independent. The depth dose measurement of the MP agrees with ion chamber depth dose measurements to within 0.7% while dose linearity was excellent. MP showed angular response dependency due to the anisotropy of the silicon diode with the maximum variation in angular response of 10.8% at gantry angle 180 deg. Angular dependence was within 3.5% for the gantry angles {+-} 75 deg. The field size dependence of the MP at isocenter agrees with ion chamber measurement to within 1.1%. In the beam perturbation study, the surface dose increased by 12.1% for a 30 x 30 cm{sup 2} field size at the source to detector distance (SDD) of 80 cm whilst the transmission for the MP was 99%. Conclusions: The radiation response of the magic plate was successfully characterized. The array of epitaxial silicon based detectors with ''drop-in'' packaging showed properties suitable to be used as a simplified multipurpose and nonperturbing 2D radiation detector for radiation therapy dosimetric verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fast method for solving both the time-dependent Schroedinger equation in angular coordinates and its associated 'm-mixing' problem

An efficient split-operator technique for solving the time-dependent Schroedinger equation in an angular coordinate system is presented, where a fast spherical harmonics transform accelerates the conversions between angle and angular momentum representations. Unlike previous techniques, this method features facile inclusion of azimuthal asymmetries (solving the ''m-mixing'' problem), adaptive time stepping, and favorable scaling, while simultaneously avoiding the need for both kinetic and potential energy matrix elements. Several examples are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measures and models for angular correlation and angular-linear correlation

Population models for dependence between two angular measurements and for dependence between an angular and a linear observation are proposed. The method of canonical correlations first leads to new population and sample measures of dependence in this latter situation. An example relating wind direction to the level of a pollutant is given. Next, applied to pairs of angular measurements, the method yields previously proposed sample measures in some special cases and a new sample measure in general.

Johnson, R. A.↗

Angular-Rate Estimation Using Delayed Quaternion Measurements

This paper presents algorithms for estimating the angular-rate vector of satellites using quaternion measurements. Two approaches are compared one that uses differentiated quaternion measurements to yield coarse rate measurements, which are then fed into two different estimators. In the other approach the raw quaternion measurements themselves are fed directly into the two estimators. The two estimators rely on the ability to decompose the non-linear part of the rotas rotational dynamics equation of a body into a product of an angular-rate dependent matrix and the angular-rate vector itself. This non unique decomposition, enables the treatment of the nonlinear spacecraft (SC) dynamics model as a linear one and, thus, the application of a PseudoLinear Kalman Filter (PSELIKA). It also enables the application of a special Kalman filter which is based on the use of the solution of the State Dependent Algebraic Riccati Equation (SDARE) in order to compute the gain matrix and thus eliminates the need to compute recursively the filter covariance matrix. The replacement of the rotational dynamics by a simple Markov model is also examined. In this paper special consideration is given to the problem of delayed quaternion measurements. Two solutions to this problem are suggested and tested. Real Rossi X-Ray Timing Explorer (RXTE) data is used to test these algorithms, and results are presented.

Azor, R.↗

Microscopic self-energy calculations and dispersive optical-model potentials

Nucleon self-energies for {sup 40,48,60}Ca isotopes are generated with the microscopic Faddeev-random-phase approximation (FRPA). These self-energies are compared with potentials from the dispersive optical model (DOM) that were obtained from fitting elastic-scattering and bound-state data for {sup 40,48}Ca. The ab initio FRPA is capable of explaining many features of the empirical DOM potentials including their nucleon asymmetry dependence. The comparison furthermore provides several suggestions to improve the functional form of the DOM potentials, including among others the exploration of parity and angular momentum dependence. The nonlocality of the FRPA imaginary self-energy, illustrated by a substantial orbital angular momentum dependence, suggests that future DOM fits should consider this feature explicitly. The roles of the nucleon-nucleon tensor force and charge-exchange component in generating the asymmetry dependence of the FRPA self-energies are explored. The global features of the FRPA self-energies are not strongly dependent on the choice of realistic nucleon-nucleon interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shape resonances in ground-state diatomic molecules: General trends and the example of RbCs

The presence of shape resonances due to tunneling through the centrifugal barrier modifies strongly the dynamics of cold atom scattering. As shown on the example of the ground and lowest triplet electronic states of the {sup 85}Rb{sup 133}Cs molecule, the crucial parameter is, as usual for cold collisions, the scattering length. A general description of shape resonances of diatomic molecules is given from three simple single channel asymptotic models, whose respective performances are discussed. The first model, which consists of a R{sup -6} potential limited at short range by a repulsive wall, positioned to reproduce the s-wave scattering length, accounts satisfactorily for the main system-independent properties of shape resonances. Introduction in the model of energy- and angular-momentum-dependent nodal lines specific to the inner part of the potential greatly improves its efficiency. When the energy and angular momentum dependence of the nodal lines cannot be deduced from full potential calculations or from experiment, a rough, but universal, estimate of these properties is obtained by extending the R{sup -6} behavior of the potential up to the origin.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electronic quenching of O({sup 1}D) by Xe: Oscillations in the product angular distribution and their dependence on collision energy

The dynamics of the O({sup 1}D) + Xe electronic quenching reaction was investigated in a crossed beam experiment at four collision energies. Marked large-scale oscillations in the differential cross sections were observed for the inelastic scattering products, O({sup 3}P) and Xe. The shape and relative phases of the oscillatory structure depend strongly on collision energy. Comparison of the experimental results with time-independent scattering calculations shows qualitatively that this behavior is caused by Stueckelberg interferences, for which the quantum phases of the multiple reaction pathways accessible during electronic quenching constructively and destructively interfere.

74 ATOMIC AND MOLECULAR PHYSICS↗

Angular distribution and altitude dependence of atmospheric neutrons from 10 to 100 MeV

The altitude dependence of atmospheric neutrons from ground level to 5 g/sq cm of residual atmosphere at neutron energies of 10 to 100 MeV is reported. Ground level measurements were taken at Cape Girardeau, Missouri, on Sept. 18, 1972. The other measurements were made during ascent and float on launch from Palestine, Texas, on Sept. 26, 1971. The intensity of both the downward- and the upward-moving neutrons is maximum at about 100 g/sq cm of residual atmosphere. Neutron angular distributions are reported from 20 to 80 deg and from 100 to 160 deg for 10- to 100-MeV neutrons. Omnidirectional fluxes at altitudes of 5, 50, 100, and 200 g/sq cm of residual atmosphere are in good agreement with recent theoretical calculations of Armstrong et al. (1973) in the three energy intervals of 10 to 30, 30 to 50, and 50 to 100 MeV.

Preszler, A. M.↗

Angular momentum loss in low-mass stars

The wind models discussed by Mestel (1984) are used here to formulate a general expression for the rate of angular momentum loss by magnetic stellar winds as a function of magnetic field configuration, rotation rate, and stellar model properties. The sensitivity of the rotation velocity to the various wind model parameters, the initial angular momenta, and the time dependence of the angular velocity for each mass is shown. The theoretical results are compared with observational ones, and it is found that the existence of very rapidly rotating stars in young clusters implies that low-mass stars are formed with a large spread of angular momentum. The high efficiency of angular momentum loss through magnetic stellar winds causes the rotation velocity to become less dependent on initial angular momentum J0 with time; by 300 million yur, the rotation velocity becomes independent of J0. This results in a decrease with time in the spread of rotation velocities as a function of stellar mass in young clusters.

Kawaler, Steven D.↗

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

Retrieval of full angular- and energy-dependent complex transition dipoles in the molecular frame from laser-induced high-order harmonic signals with aligned molecules

High-order harmonic signals generated in molecules are the consequence of coherent summation of complex laser-induced transition dipoles $\textit{d}(θ, ω)$ with each fixed-in-space molecule; here $\theta$ is the angle of the molecular axis with respect to the laser polarization axis and $\omega$ is the harmonic energy. In the so-called rotational coherent spectroscopy, it is proposed to extract the fixed-in-space $\textit{d}(θ, ω)$ in the molecular frame by measuring harmonics generated by a probing laser from the rotational molecular wave packets that have been prepared by a prior pump laser. By varying the time delay between the two lasers, methods have been utilized to extract the $\theta$ dependence of both the amplitude and phase of each individual harmonic, but the relative phase between harmonics cannot be retrieved. Here we report that this limitation can be removed. It requires the additional measurement of harmonic spectra versus the pump-probe angles at one fixed time delay. The two-dimensional input harmonic data (time-delay and pump-probe angle) are then used to retrieve the full complex transition dipole $\textit{d}(θ, ω)$ using a retrieval method based on machine learning algorithms. Finally, we demonstrate this method on N 2 and CO 2 molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dosimetric characterization of a synthetic single crystal diamond detector in clinical radiation therapy small photon beams

Purpose: To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. Methods: The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherapic photon beams. The stability of the detector response and its dose and dose rate dependence were measured. Different square field sizes ranging from 1 Multiplication-Sign 1 cm{sup 2} to 10 Multiplication-Sign 10 cm{sup 2} were used during comparative dose distribution measurements by means of percentage depth dose curves (PDDs), lateral beam profiles, and output factors. The angular and temperature dependence of the diamond detector response were also studied. Results: The detector response shows a deviation from linearity of less than {+-}0.5% in the 0.01-7 Gy range and dose rate dependence below {+-}0.5% in the 1-6 Gy/min range. PDDs and output factors are in good agreement with those measured by the reference ionization chamber within 1%. No angular dependence is observed by rotating the detector along its axis, while {approx}3.5% maximum difference is measured by varying the radiation incidence angle in the polar direction. The temperature dependence was investigated as well and a {+-}0.2% variation of the detector response is found in the 18-40 Degree-Sign C range. Conclusions: The obtained results indicate the investigated synthetic diamond-based detector as a candidate for small field clinical radiation dosimetry in advanced radiation therapy techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-dependent and time-integrated angular analysis of B{yields}{phi}K{sub S}{sup 0}{pi}{sup 0} and {phi}K{sup {+-}}{pi}{sup {+-}}

We perform a time-dependent and time-integrated angular analysis of the decays B{sup 0}{yields}{phi}K*(892){sup 0}, {phi}K{sub 2}*(1430){sup 0}, and {phi}(K{pi}){sub 0}*{sup 0} with the final sample of about 465x10{sup 6} BB pairs recorded with the BABAR detector. Twenty-four parameters are investigated, including the branching fractions, CP-violation parameters, and parameters sensitive to final-state interactions. We use the dependence on the K{pi} invariant mass of the interference between the scalar and vector or tensor components to resolve discrete ambiguities of the strong and weak phases. We use the time evolution of the B{yields}{phi}K{sub S}{sup 0}{pi}{sup 0} channel to extract the CP-violation phase difference {delta}{phi}{sub 00}=0.28{+-}0.42{+-}0.04 between the B and B decay amplitudes. When the B{yields}{phi}K{sup {+-}}{pi}{sup {+-}} channel is included, the fractions of longitudinal polarization f{sub L} of the vector-vector and vector-tensor decay modes are measured to be 0.494{+-}0.034{+-}0.013 and 0.901{sub -0.058}{sup +0.046}{+-}0.037, respectively. This polarization pattern requires the presence of a positive-helicity amplitude in the vector-vector decay from a currently unknown source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VLBI angular broadening measurements in the Cygnus region

Multifrequency VLBI observations of angular broadening are reported for eight compact radio sources whose lines of sight pass through the Galactic plane in Cygnus. The characteristic lambda-squared dependence of angular size is used to distinguish between scattered and intrinsic structure. The measured angular sizes of four of the eight sources exhibit a lambda-squared dependence, a result consistent with angular broadening by intervening turbulence. Variation in the strength of scattering as a function of position indicates that scattering in the Cygnus region changes by a factor of 2-5 for angular separations of a few degrees. With the exception of one source, the observed angular broadening is confined within a few degrees of the Galactic plane.

Fey, Alan L.↗

Systematic description of evaporation spectra for light and heavy compound nuclei

To systematically describe evaporation spectra for light and heavy compound nuclei over a large range of excitation energies, it was necessary to consider three ingredients in the statistical model. First, transmission coefficients or barrier penetration factors for charged-particle emission are typically taken from global fits to elastic-scattering data. However, such transmission coefficients do not reproduce the barrier region of evaporation spectra and reproduction of the data requires a distributions of Coulomb barriers. This is possibly associated with large fluctuations in the compound-nucleus shape or density profile. Second, for heavy nuclei, an excitation-energy dependent level-density parameter is required to describe the slope of the exponential tails of these spectra. The level-density parameter was reduced at larger temperatures, consistent with the expected fadeout of long-range correlation, but the strong A dependence of this effect is unexpected. Last, to describe the angular-momentum dependence of the level density in light nuclei at large spins, the macroscopic rotational energy of the nucleus has to be reduced from the values predicted with the finite-range liquid-drop model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wave packet dynamics in hole Luttinger systems

For hole systems with an effective spin 3/2 we analyzed analytically and numerically the evolution of wave packets with the different initial polarizations. The dynamics of such systems is determined by the 4x4 Luttinger Hamiltonian. We work in the space of arbitrary superposition of light- and heavy-hole states of the ''one-particle system.'' For strong anisotropic packets in three-dimensional semiconductors we obtained the analytical solution for the components of wave function and analyzed the space-time dependence of probability densities as well as angular momentum densities. Depending on the value of the parameter a=k{sub 0}d (k{sub 0} is the average momentum vector and d is the packet width) two scenarios of evolution are realized. For a>>1 the initial wave packet splits into two parts and the coordinates of packet center experience the transient oscillations or Zitterbewegung (ZB) as for other two-band systems. In the case when a<<1 the distribution of probability density at t>0 remains almost cylindrically symmetric and the ripples arise at the circumference of wave packet. The ZB in this case is absent. We evaluated and visualized for different values of parameter a the space-time dependence of angular momentum densities, which have the multipole structure. It was shown that the average momentum components can precess in the absence of external or effective magnetic fields due to the interference of the light- and heavy-hole states. For localized initial states this precession has a transient character.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗