Search NASA⌕ Search

SEARCH · Search NASA

Results for “Azimuth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Experimental investigation of abnormal transverse flow enhancement of α particles in heavy-ion collisions

The mass dependence of the transverse flow for Z = 1–5 fragments from the collisions of 40 Ar + 27 Al, 40 Ar + 48 Ti, and 40 Ar + 58 Ni at 47 MeV/nucleon is investigated experimentally in this article. The transverse flow values are determined using the in-plane components of the fragment transverse momenta, where three conventional methods, i.e., the kinetic flow tensor method, the transverse momentum analysis method, and the azimuthal correlation method, are applied to reconstruct the reaction plane in an event-by-event basis. It is demonstrated from the comparison of the present experimental mass dependent flow measurements and the model simulations using an improved antisymmetrized molecular dynamics model that the experimentally observed abnormal α transverse flow enhancement is closely related to the reaction plane reconstruction procedure in the flow extraction. We further investigate the physical existence of the abnormal α flow behavior using a two-particle azimuthal correlation method, which allows us to provide the relative flow magnitude information with an identification of fragment charge number without the knowledge of the reaction plane differing from the three conventional methods. It is found that the relative flow magnitudes deduced from the two-particle azimuthal correlation functions with an identification of Z, with the correction for the recoil effect imposed by the momentum conservation, show a monotonically increasing trend as a function of fragment charge number, with no exception of the α flow enhancement. These results, in addition to those from the improved antisymmetrized molecular dynamics model simulations, definitely provide experimental evidences for the inexistence of the abnormal α flow behavior in the heavy-ion collisions at the present incident energy region in nature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charged and strange hadron elliptic flow in Cu+Cu collisions at sq root(s{sub NN})=62.4 and 200 GeV

We present the results of an elliptic flow, v{sub 2}, analysis of Cu+Cu collisions recorded with the solenoidal tracker detector (STAR) at the BNL Relativistic Heavy Ion Collider at sq root(s{sub NN})=62.4 and 200 GeV. Elliptic flow as a function of transverse momentum, v{sub 2}(p{sub T}), is reported for different collision centralities for charged hadrons h{sup +}- and strangeness-ontaining hadrons K{sub S}{sup 0}, LAMBDA, XI, and phi in the midrapidity region |eta|<1.0. Significant reduction in systematic uncertainty of the measurement due to nonflow effects has been achieved by correlating particles at midrapidity, |eta|<1.0, with those at forward rapidity, 2.5<|eta|<4.0. We also present azimuthal correlations in p+p collisions at sq root(s)=200 GeV to help in estimating nonflow effects. To study the system-size dependence of elliptic flow, we present a detailed comparison with previously published results from Au+Au collisions at sq root(s{sub NN})=200 GeV. We observe that v{sub 2}(p{sub T}) of strange hadrons has similar scaling properties as were first observed in Au+Au collisions, that is, (i) at low transverse momenta, p{sub T}<2 GeV/c, v{sub 2} scales with transverse kinetic energy, m{sub T}-m, and (ii) at intermediate p{sub T}, 2<p{sub T}<4 GeV/c, it scales with the number of constituent quarks, n{sub q}. We have found that ideal hydrodynamic calculations fail to reproduce the centrality dependence of v{sub 2}(p{sub T}) for K{sub S}{sup 0} and LAMBDA. Eccentricity scaled v{sub 2} values, v{sub 2}/epsilon, are larger in more central collisions, suggesting stronger collective flow develops in more central collisions. The comparison with Au+Au collisions, which go further in density, shows that v{sub 2}/epsilon depends on the system size, that is, the number of participants N{sub part}. This indicates that the ideal hydrodynamic limit is not reached in Cu+Cu collisions, presumably because the assumption of thermalization is not attained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam-energy-dependent two-pion interferometry and the freeze-out eccentricity of pions measured in heavy ion collisions at the STAR detector

In this study, we present results of analyses of two-pion interferometry in Au+Au collisions at √s NN = 7.7, 11.5, 19.6, 27, 39, 62.4, and 200 GeV measured in the STAR detector as part of the RHIC Beam Energy Scan program. The extracted correlation lengths (HBT radii) are studied as a function of beam energy, azimuthal angle relative to the reaction plane, centrality, and transverse mass ( mT ) of the particles. The azimuthal analysis allows extraction of the eccentricity of the entire fireball at kinetic freeze-out. The energy dependence of this observable is expected to be sensitive to changes in the equation of state. A new global fit method is studied as an alternate method to directly measure the parameters in the azimuthal analysis. The eccentricity shows a monotonic decrease with beam energy that is qualitatively consistent with the trend from all model predictions and quantitatively consistent with a hadronic transport model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Revealing long-range multiparticle collectivity in small collision systems via subevent cumulants

Multi-particle azimuthal cumulants, often used to study collective flow in high-energy heavy-ion collisions, have recently been applied in small collision systems such as pp and p+A to extract the second-order azimuthal harmonic flow v 2 . Recent observation of four-, six- and eight-particle cumulants with “correct sign” c 2 {4} < 0, c 2 {6} > 0, c 2 {8} < 0 and approximate equality of the inferred single-particle harmonic flow, v 2 {4} ≈ v 2 {6} ≈ v 2 {8}, have been used as strong evidence for a collective emission of all soft particles produced in the collisions. In this paper, we show that these relations in principle could be violated due to the non-Gaussianity in the event-by-event fluctuation of flow and/or non-flow. Furthermore, we show, using pp events generated with the PYTHIA model, that c 2 {2k} obtained with standard cumulant method are dominated by non-flow from dijets. An alternative cumulant method based on two or more η-separated subevents is proposed to suppress the dijet contribution. The new method is shown to be able to recover a flow signal as low as 4% imposed on the PYTHIA events, independently of how the event activity class is defined. Therefore the subevent cumulant method offers a more robust way of studying collectivity based on the existence of long-range azimuthal correlations between multiple distinct η ranges. Finally, the prospect of using the subevent cumulants to study collective flow in A+A collisions, in particular its longitudinal dynamics, is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Bottom Quark Contribution to Nonphotonic Electron Production in p + p Collisions at ¼ 200 GeV

The contribution of B meson decays to nonphotonic electrons, which are mainly produced by the semileptonic decays of heavy-flavor mesons, in p+p collisions at {radical}s = 200 GeV has been measured using azimuthal correlations between nonphotonic electrons and hadrons. The extracted B decay contribution is approximately 50% at a transverse momentum of p{sub T} {ge} 5 GeV/c. These measurements constrain the nuclear modification factor for electrons from B and D meson decays. The result indicates that B meson production in heavy ion collisions is also suppressed at high p{sub T}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Jets, Mach Cones, Hot Spots, Ridges, Harmonic Flow, Dihadron, and {gamma}-Hadron Correlations in High-Energy Heavy-Ion Collisions

Within the AMPT Monte Carlo model, fluctuations in the initial transverse parton density are shown to lead to harmonic flows. The net back-to-back dihadron azimuthal correlation after subtraction of contributions from harmonic flows still has a double peak that is independent of the initial geometric triangularity and unique to the jet-induced Mach cone and expanding hot spots distorted by radial flow. The longitudinal structure of hot spots also leads to a nearside ridge in dihadron correlation with a large rapidity gap. By successively randomizing the azimuthal angle of the transverse momenta and positions of initial partons, one can isolate the effects of jet-induced medium excitation and expanding hot spots on the dihadron azimuthal correlation. The double peaks in the net dihadron and {gamma}-hadron correlation are quantitatively different since the later is caused only by jet-induced Mach cone.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Enhanced Long-Range Elliptic Anisotropies Inside High-Multiplicity Jets in p p Collisions at s = 13 TeV

A search for collective effects inside jets produced in proton-proton collisions is performed via correlation measurements of charged particles using the CMS detector at the CERN LHC. The analysis uses data collected at a center-of-mass energy of s = 13 TeV , corresponding to an integrated luminosity of 138 fb − 1 . Jets are reconstructed with the anti- k T algorithm with a distance parameter of 0.8 and are required to have transverse momentum greater than 550 GeV and pseudorapidity | η jet | < 1.6 . Two-particle correlations among the charged particles within the jets are studied as functions of the particles’ azimuthal angle and pseudorapidity separations ( Δ ϕ * and Δ η * ) in a jet coordinate basis, where particles’ η * , ϕ * are defined relative to the direction of the jet. The correlation functions are studied in classes of in-jet charged-particle multiplicity up to N ch j ≈ 100 . Fourier harmonics are extracted from long-range azimuthal correlation functions to characterize azimuthal anisotropy for | Δ η * | > 2 . For low- N ch j jets, the long-range elliptic anisotropic harmonic, v 2 * , is observed to decrease with N ch j . This trend is well described by Monte Carlo event generators. However, a rising trend for v 2 * emerges at N ch j ≳ 80 , hinting at a possible onset of collective behavior, which is not reproduced by the models tested. This observation yields new insights into the dynamics of jet evolution in the vacuum. © 2024 CERN, for the CMS Collaboration 2024 CERN

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high-speed one-dimensional detector for time-resolved small -angle X-ray scattering : design and characterization.

A high-speed one-dimensional detector for time-resolved small-angle x-ray scattering has been designed and built for experiments at the Advanced Photon Source of Argonne National Laboratory. This detector is made from a 500-?m thick by 150-mm diameter ultra-high-purity n-type silicon wafer. The electrodes, which are a series of concentric rings that are deposited in the wafer, integrate the scattered x-rays over the azimuthal angle and, thereby, produce a one-dimensional detector. This design yields 128 rings, which allows parallel processing of the signal from each ring. The readout electronics consist of transimpedance front-end amplifiers, one for each ring, followed by active pulse-shaping filters. The amplifier signals are digitized using 12-bit analog-to-digital converters, one per ring, which operate at 20 MHz. The frame rate of the system is 271 kHz. Up to 220 - 1 scattering profiles may be stored on a random access memory chip and transferred to a data file at a rate of 16 x 103 profiles/sec. For X-ray energies between 3.5 and 13.2 keV the efficiency exceeds 80%. The resolving time of the electronics is 300 ns, which is sufficient to isolate electronically a single pulse of scattered x-rays when the synchrotron is operated in a hybrid or asymmetric fill pattern. Therefore, laser-pump/x-ray-probe experiments can be performed without a mechanical shutter. Examples of time-resolved speckle and the kinetics of the formation of sodium chloride particles are presented. This detector is capable of acquiring small-angle x-ray scattering profiles over multiple time scales, which are needed to characterize many chemical, physical, and biological processes. In addition, this detector may be tested and calibrated before experimental runs, without access to an intense beam of x-rays, with alpha particles from a radioactive source such as 241Am.

43 PARTICLE ACCELERATORS↗

High-Frequency Acoustic Mode Identification of Unstable Combustors

Abstract High frequency thermoacoustic instabilities are becoming increasingly problematic in modern combustion systems. Understanding which acoustic mode is being excited is important for understanding potential mechanisms and control approaches — for example, influence of a helical shear layer mode on the flame has profoundly different effects on the first tangential acoustic mode, than a higher order axial mode of similar frequency. Nonetheless, the modal density increases with frequency and it becomes increasingly difficult to determine which acoustic mode is self-excited, based upon frequency calculations alone. Moreover, access issues and cost usually limit the number of pressure probes that can be distributed axially and azimuthally in the combustor. This paper presents a methodology for identifying the acoustic mode by using high temperature pressure transducers flush mounted in a combustion chamber. Modal identification is demonstrated with a siren under non-reacting conditions. The siren is mounted on the chamber to excite longitudinal and azimuthal waves. Five acoustic sensors at different axial and azimuthal locations measure the pressure fluctuations simultaneously. Given the forcing frequency and the speed of sound, the pressure distribution in the combustor is reconstructed in the time domain from the measured data by using a least squares method to determine its mode shapes. In addition, the finite element method (FEM) solver is used to provide the eigenfrequencies and corresponding mode shapes. The test results demonstrate that the mode shapes from the reconstructed data and corresponding frequencies are consistent with those predicted from the FEM, which validates the methodology in this study. In addition, the methodology is extended to practical reacting cases without the siren to determine the acoustic mode shapes of naturally occurring instabilities. In these cases, the modal features have strong stochastic features, such as what appear to be stochastic variations in overall amplitude and relative amplitudes of clockwise and counterclockwise waves.

Kim, J.↗

Modal reduction in single crystal sapphire optical fiber

A new type of single crystal sapphire optical fiber (SCSF) design is proposed to reduce the number of guided modes via a highly dispersive cladding with a periodic array of high and low index regions in the azimuthal direction. The structure retains a “core” region of pure single crystal (SC) sapphire in the center of the fiber and a “cladding” region of alternating layers of air and SC sapphire in the azimuthal direction that is uniform in the radial direction. The modal characteristics and confinement losses of the fundamental mode were analyzed via the finite element method by varying the effective core diameter and the dimensions of the “windmill” shaped cladding. The simulation results showed that the number of guided modes were significantly reduced in the “windmill” fiber design, as the radial dimension of the air and SC sapphire cladding regions increase with corresponding decrease in the azimuthal dimension. It is anticipated that the “windmill” SCSF will readily improve the performance of current fiber optic sensors in the harsh environment and potentially enable those that were limited by the extremely large modal volume of unclad SCSF.

36 MATERIALS SCIENCE↗

The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry

Purpose: Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp dose fall off. One of the major problems with quality assurance (QA) of SRT/SRS is the availability of suitable detectors with the required spatial resolution. The authors present a novel detector that they refer to as the dose magnifying glass (DMG), which has a high spatial resolution (0.2 mm) and is capable of meeting the stringent requirements of QA and dosimetry in SRS/SRT therapy. Methods: The DMG is an array of 128 phosphor implanted n{sup +} strips on a p-type Si wafer. The sensitive area defined by a single n{sup +} strip is 20x2000 {mu}m{sup 2}. The Si wafer is 375 {mu}m thick. It is mounted on a 0.12 mm thick Kapton substrate. The authors studied the dose per pulse (dpp) and angular response of the detector in a custom-made SRS phantom. The DMG was used to determine the centers of rotation and positioning errors for the linear accelerator's gantry, couch, and collimator rotations. They also used the DMG to measure the profiles and the total scatter factor (S{sub cp}) of the SRS cones. Comparisons were made with the EBT2 film and standard S{sub cp} values. The DMG was also used for dosimetric verification of a typical SRS treatment with various noncoplanar fields and arc treatments when applied to the phantom. Results: The dose per pulse dependency of the DMG was found to be <5% for a dpp change of 7.5 times. The angular response of the detector was investigated in the azimuthal and polar directions. The maximum polar angular response was 13.8% at the gantry angle of 320 deg., which may be partly due to the phantom geometry. The maximum azimuthal angular response was 15.3% at gantry angles of 90 deg. and 270 deg. The angular response at the gantry angle of 180 deg. was 6.3%. A correction function was derived to correct for the angular dependence of the detector, which takes into account the contribution of the azimuthal and polar angular response at different treatment couch positions. The maximum positioning errors due to collimator, gantry, and couch rotation were 0.2{+-}0.1, 0.4{+-}0.1, and 0.4{+-}0.2 mm, respectively. The SRS cone S{sub cp} agrees very well with the standard data with an average difference of 1.2{+-}1.1%. Comparison of the relative intensity profiles of the DMG and EBT2 measurements for a simulated SRS treatment shows a maximum difference of 2.5%. Conclusions: The DMG was investigated for dose per pulse and angular dependency. Its application to SRS/SRT delivery verification was demonstrated. The DMG with its high spatial resolution and real time capability allows measurement of dose profiles for cone applicators down to 5 mm in diameter, both accurately and rapidly as required in typical SRS/SRT deliveries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid emission angle selection for rotating-shield brachytherapy

Purpose: The authors present a rapid emission angle selection (REAS) method that enables the efficient selection of the azimuthal shield angle for rotating shield brachytherapy (RSBT). The REAS method produces a Pareto curve from which a potential RSBT user can select a treatment plan that balances the tradeoff between delivery time and tumor dose conformity. Methods: Two cervical cancer patients were considered as test cases for the REAS method. The RSBT source considered was a Xoft Axxent{sup TM} electronic brachytherapy source, partially shielded with 0.5 mm of tungsten, which traveled inside a tandem intrauterine applicator. Three anchor RSBT plans were generated for each case using dose-volume optimization, with azimuthal shield emission angles of 90 Degree-Sign , 180 Degree-Sign , and 270 Degree-Sign . The REAS method converts the anchor plans to treatment plans for all possible emission angles by combining neighboring beamlets to form beamlets for larger emission angles. Treatment plans based on exhaustive dose-volume optimization (ERVO) and exhaustive surface optimization (ERSO) were also generated for both cases. Uniform dwell-time scaling was applied to all plans such that that high-risk clinical target volume D{sub 90} was maximized without violating the D{sub 2cc} tolerances of the rectum, bladder, and sigmoid colon. Results: By choosing three azimuthal emission angles out of 32 potential angles, the REAS method performs about 10 times faster than the ERVO method. By setting D{sub 90} to 85-100 Gy{sub 10}, the delivery times used by REAS generated plans are 21.0% and 19.5% less than exhaustive surface optimized plans used by the two clinical cases. By setting the delivery time budget to 5-25 and 10-30 min/fx, respectively, for two the cases, the D{sub 90} contributions for REAS are improved by 5.8% and 5.1% compared to the ERSO plans. The ranges used in this comparison were selected in order to keep both D{sub 90} and the delivery time within acceptable limits. Conclusions: The REAS method enables efficient RSBT treatment planning and delivery and provides treatment plans with comparable quality to those generated by exhaustive replanning with dose-volume optimization.

60 APPLIED LIFE SCIENCES↗

A nonvoxel-based dose convolution/superposition algorithm optimized for scalable GPU architectures

Purpose: Real-time adaptive planning and treatment has been infeasible due in part to its high computational complexity. There have been many recent efforts to utilize graphics processing units (GPUs) to accelerate the computational performance and dose accuracy in radiation therapy. Data structure and memory access patterns are the key GPU factors that determine the computational performance and accuracy. In this paper, the authors present a nonvoxel-based (NVB) approach to maximize computational and memory access efficiency and throughput on the GPU. Methods: The proposed algorithm employs a ray-tracing mechanism to restructure the 3D data sets computed from the CT anatomy into a nonvoxel-based framework. In a process that takes only a few milliseconds of computing time, the algorithm restructured the data sets by ray-tracing through precalculated CT volumes to realign the coordinate system along the convolution direction, as defined by zenithal and azimuthal angles. During the ray-tracing step, the data were resampled according to radial sampling and parallel ray-spacing parameters making the algorithm independent of the original CT resolution. The nonvoxel-based algorithm presented in this paper also demonstrated a trade-off in computational performance and dose accuracy for different coordinate system configurations. In order to find the best balance between the computed speedup and the accuracy, the authors employed an exhaustive parameter search on all sampling parameters that defined the coordinate system configuration: zenithal, azimuthal, and radial sampling of the convolution algorithm, as well as the parallel ray spacing during ray tracing. The angular sampling parameters were varied between 4 and 48 discrete angles, while both radial sampling and parallel ray spacing were varied from 0.5 to 10 mm. The gamma distribution analysis method (γ) was used to compare the dose distributions using 2% and 2 mm dose difference and distance-to-agreement criteria, respectively. Accuracy was investigated using three distinct phantoms with varied geometries and heterogeneities and on a series of 14 segmented lung CT data sets. Performance gains were calculated using three 256 mm cube homogenous water phantoms, with isotropic voxel dimensions of 1, 2, and 4 mm. Results: The nonvoxel-based GPU algorithm was independent of the data size and provided significant computational gains over the CPU algorithm for large CT data sizes. The parameter search analysis also showed that the ray combination of 8 zenithal and 8 azimuthal angles along with 1 mm radial sampling and 2 mm parallel ray spacing maintained dose accuracy with greater than 99% of voxels passing the γ test. Combining the acceleration obtained from GPU parallelization with the sampling optimization, the authors achieved a total performance improvement factor of >175 000 when compared to our voxel-based ground truth CPU benchmark and a factor of 20 compared with a voxel-based GPU dose convolution method. Conclusions: The nonvoxel-based convolution method yielded substantial performance improvements over a generic GPU implementation, while maintaining accuracy as compared to a CPU computed ground truth dose distribution. Such an algorithm can be a key contribution toward developing tools for adaptive radiation therapy systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-155: Calibration of Variable Longitudinal Strength 103Pd Brachytherapy Sources

Purpose: Brachytherapy sources with variable longitudinal strength (VLS) allow for a customized intensity along the length of the source. These have applications in focal brachytherapy treatments of prostate cancer where dose boosting can be achieved through modulation of intra-source strengths. This work focused on development of a calibration methodology for VLS sources based on measurements and Monte Carlo (MC) simulations of five 1 cm {sup 10} {sup 3}Pd sources each containing four regions of variable {sup 103}Pd strength. Methods: The air-kerma strengths of the sources were measured with a variable-aperture free-air chamber (VAFAC). Source strengths were also measured using a well chamber. The in-air azimuthal and polar anisotropy of the sources were measured by rotating them in front of a NaI scintillation detector and were calculated with MC simulations. Azimuthal anisotropy results were normalized to their mean intensity values. Polar anisotropy results were normalized to their average transverse axis intensity values. The relative longitudinal strengths of the sources were measured via on-contact irradiations with radiochromic film, and were calculated with MC simulations. Results: The variable {sup 103}Pd loading of the sources was validated by VAFAC and well chamber measurements. Ratios of VAFAC air-kerma strengths and well chamber responses were within ±1.3% for all sources. Azimuthal anisotropy results indicated that ≥95% of the normalized values for all sources were within ±1.7% of the mean values. Polar anisotropy results indicated variations within ±0.3% for a ±7.6° angular region with respect to the source transverse axis. Locations and intensities of the {sup 103}Pd regions were validated by radiochromic film measurements and MC simulations. Conclusion: The calibration methodology developed in this work confirms that the VLS sources investigated have a high level of polar uniformity, and that the strength and longitudinal intensity can be verified experimentally and through MC simulations. {sup 103}Pd sources were provided by CivaTech Oncology, Inc.

07 ISOTOPE AND RADIATION SOURCES↗

How to measure the charm density in the proton

We study two experimental ways to measure the heavy-quark content of the proton: using the Callan-Gross ratio R(x, Q{sup 2}) = F{sub L}/F{sub T} and/or the azimuthal cos(2φ) asymmetry in DIS. Our approach is based on the following observations. First, the ratio R(x, Q{sup 2}) = F{sub L}/F{sub T} and azimuthal cos(2φ) asymmetry in heavy-quark leptoproduction are stable, both parametrically and perturbatively, within pQCD. Second, both these quantities are sensitive to resummation of the mass logarithms of the type α{sub s}ln(Q{sup 2}/m{sup 2}). We conclude that the heavy-quark densities in the nucleon can, in principle, be determined from high-Q{sup 2} data on the Callan-Gross ratio and/or the azimuthal asymmetry. In particular, the charm content of the proton can be measured in future studies at the proposed Large Hadron-Electron (LHeC) and Electron-Ion (EIC) Colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of Implosion of Twisted Nested Arrays at the Angara-5-1 Facility

Results are presented from experimental studies of the implosion of twisted nested arrays in which the wires of the outer and inner arrays are twisted about the array axis in opposite directions (clockwise and counterclockwise). Experiments with twisted arrays were carried out at the Angara-5-1 facility at currents of up to 4 MA. The currents through the arrays were switched either simultaneously or the current pulse through the outer array was delayed by 10–15 ns with the help of an anode spark gap. It is shown that, in such arrays, the currents flow along the inclined wires and, accordingly, there are both the azimuthal and axial components of the discharge current. The process of plasma implosion in twisted arrays depends substantially on the value of the axial (longitudinal) magnetic field generated inside the array by the azimuthal currents. Two-dimensional simulations of the magnetic field in twisted nested arrays were performed in the (r, z) geometry with allowance for the skin effect in the discharge electrodes. It is shown that, depending on the geometry of the discharge electrodes, different configurations of the magnetic field can be implemented inside twisted nested arrays. The calculated magnetic configurations are compared with the results of measurements of the magnetic field inside such arrays. It is shown that the configuration of the axial magnetic field inside a twisted nested array depends substantially on the distribution of the azimuthal currents between the inner and outer arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wind Measurements from Arc Scans with Doppler Wind Lidar

When defining optimal scanning geometries for scanning lidars for wind energy applications, we found that it is still an active field of research. Our paper evaluates uncertainties associated with arc scan geometries and presents recommendations regarding optimal configurations in the atmospheric boundary layer. The analysis is based on arc scan data from a Doppler wind lidar with one elevation angle and seven azimuth angles spanning 30° and focuses on an estimation of 10-min mean wind speed and direction. When flow is horizontally uniform, this approach can provide accurate wind measurements required for wind resource assessments in part because of its high resampling rate. Retrieved wind velocities at a single range gate exhibit good correlation to data from a sonic anemometer on a nearby meteorological tower, and vertical profiles of horizontal wind speed, though derived from range gates located on a conical surface, match those measured by mast-mounted cup anemometers. Uncertainties in the retrieved wind velocity are related to high turbulent wind fluctuation and an inhomogeneous horizontal wind field. Moreover, the radial velocity variance is found to be a robust measure of the uncertainty of the retrieved wind speed because of its relationship to turbulence properties. It is further shown that the standard error of wind speed estimates can be minimized by increasing the azimuthal range beyond 30° and using five to seven azimuth angles.

17 WIND ENERGY↗

Spectroscopic ellipsometer based on direct measurement of polarization ellipticity

A polarizer-sample-Wollaston prism analyzer ellipsometer is described in which the ellipsometric angles {psi} and {Delta} are determined by direct measurement of the elliptically polarized light reflected from the sample. With the Wollaston prism initially set to transmit p- and s-polarized light, the azimuthal angle P of the polarizer is adjusted until the two beams have equal intensity. This condition yields {psi}={+-}P and ensures that the reflected elliptically polarized light has an azimuthal angle of {+-}45 deg. and maximum ellipticity. Rotating the Wollaston prism through 45 deg. and adjusting the analyzer azimuth until the two beams again have equal intensity yields the ellipticity that allows {Delta} to be determined via a simple linear relationship. The errors produced by nonideal components are analyzed. We show that the polarizer dominates these errors but that for most practical purposes, the error in {psi} is negligible and the error in {Delta} may be corrected exactly. A native oxide layer on a silicon substrate was measured at a single wavelength and multiple angles of incidence and spectroscopically at a single angle of incidence. The best fit film thicknesses obtained were in excellent agreement with those determined using a traditional null ellipsometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗