Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Light beams and radiation patterns in random media

The purpose of this paper is to apply a numerical technique in solving problems involving light beams in a random medium. The technique starts by generating numerically sample media with prescribed statistical properties. Rays are then traced in these sample media, and the ray statistics are compiled. These statistics are utilized to find the mean square displacement and distribution of a beam. Problems on beam broadening and distortion of radiation patterns are considered. Fluctuations in wave amplitude and phase are also investigated. When possible, the numerical results are compared with the analytical results and experimental results.

Youakim, M. Y.↗

SU-C-207A-06: On-Line Beam Range Verification with Multiple Scanning Particle Beams: Initial Feasibility Study with Simulations

Purpose: To investigate the feasibility and requirement for intra-fraction on-line multiple scanning particle beam range verifications (BRVs) with in-situ PET imaging, which is beyond the current single-beam BRV with extra factors that will affect the BR measurement accuracy, such as beam diameter, separation between beams, and different image counts at different BRV positions. Methods: We simulated a 110-MeV proton beam with 5-mm diameter irradiating a uniform PMMA phantom by GATE simulation, which generated nuclear interaction-induced positrons. In this preliminary study, we simply duplicated these positrons and placed them next to the initial protons to approximately mimic the two spatially separated positron distributions produced by two beams parallel to each other but with different beam ranges. These positrons were then imaged by a PET (∼2-mm resolution, 10% sensitivity, 320×320×128 mm^3 FOV) with different acquisition times. We calculated the positron activity ranges (ARs) from reconstructed PET images and compared them with the corresponding ARs of original positron distributions. Results: Without further image data processing and correction, the preliminary study show the errors between the measured and original ARs varied from 0.2 mm to 2.3 mm as center-to-center separations and range differences were in the range of 8–12 mm and 2–8 mm respectively, indicating the accuracy of AR measurement strongly depends on the beam separations and range differences. In addition, it is feasible to achieve ≤ 1.0-mm accuracy for both beams with 1-min PET acquisition and 12 mm beam separation. Conclusion: This study shows that the overlap between the positron distributions from multiple scanning beams can significantly impact the accuracy of BRVs of distributed particle beams and need to be further addressed beyond the established method of single-beam BRV, but it also indicates the feasibility to achieve accurate on-line multi-beam BRV with further improved method.

60 APPLIED LIFE SCIENCES↗

Suprathermal plasma observed on STS-3 Mission by plasma diagnostics package

Artificially produced electron beams were used extensively during the past decade as a means of probing the magnetosphere, and more recently as a means of actively controlling spacecraft potential. Experimentation in these areas has proven valuable, yet at times confusing, due to the interaction of the electron beam with the ambient plasma. The OSS-1/STS-3 Mission in March 1982 provided a unique opportunity to study beam-plasma interactions at an altitude of 240 km. On board for this mission was a Fast Pulse Electron Generator (FPEG). Measurements made by the Plasma Diagnostics Package (PDP) while extended on the Orbiter RMS show modifications of the ion and electron energy distributions during electron beam injection. Observations made by charged particle detectors are discussed and related to measurements of Orbiter potential. Several of the PDP instruments, the joint PDP/FPEG experiment, and observations made during electron beam injection are described.

Paterson, W.↗

SU-F-T-270: A Technique for Modeling a Diode Array Into the TPS for Lung SBRT Patient Specific QA

Purpose: To accurately match the treatment planning system (TPS) with the measurement environment, where quality assurance (QA) devices are used to collect data, for lung Stereotactic Body Radiation Therapy (SBRT) patient specific QA. Incorporation of heterogeneities is also studied. Methods: Dual energy computerized tomography (DECT) and single energy computerized tomography (SECT) were used to model phantoms incorporating a 2-D diode array into the TPS. A water-equivalent and a heterogeneous phantom (simulating the thoracic region of a patient) were studied. Monte Carlo and pencil beam planar dose distributions were compared to measured distributions. Composite and individual fields were analyzed for normally incident and planned gantry angle deliveries. γ- analysis was used with criteria 3% 3mm, 2% 2mm, and 1% 1mm. Results: The Monte Carlo calculations for the DECT resulted in improved agreements with the diode array for 46.4% of the fields at 3% 3mm, 85.7% at 2% 2mm, and 92.9% at 1% 1mm.For the SECT, the Monte Carlo calculations gave no agreement for the same γ-analysis criteria. Pencil beam calculations resulted in lower agreements with the diode array in the TPS. The DECT showed improvements for 14.3% of the fields at 3% 3mm and 2% 2mm, and 28.6% at 1% 1mm.In SECT comparisons, 7.1% of the fields at 3% 3mm, 10.7% at 2% 2mm, and 17.9% at 1% 1mm showed improved agreements with the diode array. Conclusion: This study demonstrates that modeling the diode array in the TPS is viable using DECT with Monte Carlo for patient specific lung SBRT QA. As recommended by task groups (e.g. TG 65, TG 101, TG 244) of the American Association of Physicists in Medicine (AAPM), pencil beam algorithms should be avoided in the presence of heterogeneous materials, including a diode array.

60 APPLIED LIFE SCIENCES↗

MANIFESTATIONS OF ENERGETIC ELECTRONS WITH ANISOTROPIC DISTRIBUTIONS IN SOLAR FLARES. II. GYROSYNCHROTRON MICROWAVE EMISSION

We investigate the spectra and polarization of the gyrosynchrotron microwave (MW) emission generated by anisotropic electron beams in the solar corona. The electron distributions are selected from the steady propagation/precipitation model of beam electrons obtained from the time-dependent solutions of the Fokker-Planck equation taking into account particle anisotropic precipitation into a converging magnetic tube while losing energy in collisions and Ohmic losses induced by a self-induced electric field. We separate the effects of converging magnetic field from those of self-induced electric field for beams with different initial energy fluxes and spectral indices. The effect of returning electrons of the beam is negligible for the beams with relatively weak energy fluxes (F {approx}< 10{sup 10} erg cm{sup -2} s{sup -1}), while it becomes very important for the electron beams with F {approx}> 10{sup 12} erg cm{sup -2} s{sup -1}. Electric field-induced losses lead to the increase of MW emission intensity, especially at larger viewing angles ({theta} {approx}> 140{sup 0}, looking at the loop from a side). The polarization remains typical for the beam-like distributions. The combined effect of the self-induced electric field and converging magnetic field reveals a noticeable (up to a factor of 10) increase of the emission intensity (for the viewing angles {theta} {approx_equal} 140{sup 0}-150{sup 0}) in comparison with the models considering only collision factor, especially in the deeper precipitation layers (near the loop footpoints). Thus, considering the self-induced electric field is especially important for the resulting MW emission intensity, spectra shape, and polarization that can provide much closer correlation of simulations with observations in solar flares.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Halo formation and emittance growth in the transport of spherically symmetric mismatched bunched beams

The effect of an initial envelope mismatch on the transport of bunched spherically symmetric beams is investigated. A particle-core model is used to estimate the maximum radius that halo particles can reach. The theory is used to obtain an empirical formula that provides the halo size as a function of system parameters. Taking into account, the incompressibility property of the Vlasov dynamics and the resulting Landau damping, an explicit form for the final stationary distribution attained by the beam is proposed. The distribution is fully self-consistent, presenting no free fitting parameters. The theory is used to predict the relevant beam transport properties, such as the final particle density distribution, the emittance growth, and the fraction of particles that will be expelled to form halo. The theoretical results are compared to the explicit N-particle dynamics simulations, showing a good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An atomic beam of titanium for ultracold atom experiments

Here we generate an atomic beam of titanium (Ti) using a “Ti-ball” Ti-sublimation pump, which is a common getter pump used in ultrahigh vacuum systems. We show that the sublimated atomic beam can be optically pumped into the metastable 3d 3 ( 4 F)4s a 5 F 5 state, which is the lower energy level in a cycling optical transition that can be used for laser cooling. We measure the atomic density and transverse and longitudinal velocity distributions of the beam through laser fluorescence spectroscopy. We find a metastable atomic flux density of 4.3(2) × 10 9 s -1 cm -2 with a mean forward velocity of 773(8) m/s at 2.55 cm directly downstream of the center of the Ti-ball. Owing to the details of optical pumping, the beam is highly collimated along the transverse axis parallel to the optical pumping beam and the flux density falls off as 1/r. We discuss how this source can be used to load atoms into a magneto-optical trap.

47 OTHER INSTRUMENTATION↗

On-chip generation and control of the vortex beam

A method to generate and control the amplitude and phase distributions of an optical vortex beam is proposed. By introducing a holographic grating on the top of a dielectric waveguide, the free space vortex beam and the in-plane guiding wave can be converted to each other. This microscale holographic grating is very robust against the variation of geometry parameters. The designed vortex beam generator can produce the target beam with a fidelity up to 0.93, and the working bandwidth is about 175 nm with the fidelity larger than 0.80. In addition, a multiple generator composed of two holographic gratings on two parallel waveguides is studied, which can perform an effective and flexible modulation on the vortex beam by controlling the phase of the input light. Our work opens an available avenue towards the integrated orbital angular momentum devices with multiple degrees of optical freedom, which can be used for optical tweezers, micronano imaging, information processing, and so on.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Weibel instability in a strongly coupled plasma

In this paper, the growth rate of the Weibel instability is calculated for an energetic relativistic electron beam penetrated into a strongly coupled plasma, where the collision effects of background electron-ion scattering play an important role in equations. In order to calculate the growth rate of the Weibel instability, two different models of anisotropic distribution function are used. First, the distribution of the plasma and beam electrons considered as similar forms of bi-Maxwellian distribution. Second, the distribution functions of the plasma electrons and the beam electrons follows bi-Maxwellian and delta-like distributions, respectively. The obtained results show that the collision effect decreases the growth rate in two models. When the distribution function of electrons beam is in bi-Maxwellian form, the instability growth rate is greater than where the distribution function of beam electrons is in delta-like form, because, the anisotropic temperature for bi-Maxwellian distribution function in velocity space is greater than the delta-like distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rotating field mass and velocity analyzer

A rotating field mass and velocity analyzer having a cell with four walls, time dependent RF potentials that are applied to each wall, and a detector. The time dependent RF potentials create an RF field in the cell which effectively rotates within the cell. An ion beam is accelerated into the cell and the rotating RF field disperses the incident ion beam according to the mass-to-charge (m/e) ratio and velocity distribution present in the ion beam. The ions of the beam either collide with the ion detector or deflect away from the ion detector, depending on the m/e, RF amplitude, and RF frequency. The detector counts the incident ions to determine the m/e and velocity distribution in the ion beam.

Smith, Steven Joel↗

Low-energy dc ion source for low operating pressure

We report on an experimental study of an ion source based on a Penning discharge with a cold hollow cathode in crossed electric and magnetic fields. The minimum vacuum chamber operating pressure was 3 × 10{sup −5} Torr for argon and 5 × 10{sup −5} Torr for hydrogen. The use of a hollow cathode allowed decreasing the discharge operating voltage down to 350 V at a discharge current of ∼100 mA. At a discharge current of 100 mA and beam accelerating voltage of 2 kV, the ion current was 2.5 mA for argon and 8 mA for hydrogen, and the ion beam on-axis current density 170 and 450 μA/cm{sup 2}, respectively. The current-voltage characteristics of the discharge and the radial ion beam current density distribution were measured. The influence of pressure on the discharge parameters and their time stability was investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Radiotherapy for Childhood Ependymoma: Initial Clinical Outcomes and Dose Comparisons

Purpose: To report preliminary clinical outcomes for pediatric patients treated with proton beam radiation for intracranial ependymoma and compare the dose distributions of intensity-modulated radiation therapy with photons (IMRT), three-dimensional conformal proton radiation, and intensity-modulated proton radiation therapy (IMPT) for representative patients. Methods and Materials: All children with intracranial ependymoma confined to the supratentorial or infratentorial brain treated at the Francis H. Burr Proton Facility and Harvard Cyclotron between November 2000 and March 2006 were included in this study. Seventeen patients were treated with protons. Proton, IMRT, and IMPT plans were generated with similar clinical constraints for representative infratentorial and supratentorial ependymoma cases. Tumor and normal tissue dose-volume histograms were calculated and compared. Results: At a median follow-up of 26 months from the start date of radiation therapy, local control, progression-free survival, and overall survival rates were 86%, 80%, and 89%, respectively. Subtotal resection was significantly associated with decreased local control (p = 0.016). Similar tumor volume coverage was achieved with IMPT, proton therapy, and IMRT. Substantial normal tissue sparing was seen with proton therapy compared with IMRT. Use of IMPT will allow for additional sparing of some critical structures. Conclusions: Preliminary disease control with proton therapy compares favorably with the literature. Dosimetric comparisons show the advantage of proton radiation compared with IMRT in the treatment of ependymoma. Further sparing of normal structures appears possible with IMPT. Superior dose distributions were accomplished with fewer beam angles with the use of protons and IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gymnastics in Phase Space

As accelerator technology advances, the requirements on accelerator beam quality become increasingly demanding. Facing these new demands, the topic of phase space gymnastics is becoming a new focus of accelerator physics R&D. In a phase space gymnastics, the beam's phase space distribution is manipulated and precision tailored to meet the required beam qualities. On the other hand, all realization of such gymnastics will have to obey accelerator physics principles as well as technological limitations. Recent examples of phase space gymnastics include Emittance exchanges, Phase space exchanges, Emittance partitioning, Seeded FELs and Microbunched beams. The emittance related topics of this list are reviewed in this report. The accelerator physics basis, the optics design principles that provide these phase space manipulations, and the possible applications of these gymnastics, are discussed. This fascinating new field promises to be a powerful tool of the future.

43 PARTICLE ACCELERATORS↗

Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lightwave-driven electron emission for polarity-sensitive terahertz beam profiling

The full exploitation of advanced light sources in the terahertz (THz) frequency range requires versatile experimental tools to fully characterize the spatial, temporal, and spectral shapes of the THz electric field. Several techniques for passive THz beam profiling exist that offer information about the temporally integrated intensity. Thus, any information about the electric field itself is lost. Here, we show that a UV–visible light emission produced via a lightwave-driven field emission from single-layer metasurfaces can be used to visualize the peak electric field distribution of THz beams in real time. Our technique is scalable up to frequencies approaching the plasma frequency of the metal used for the metasurface. Uniquely, our device is sensitive to the absolute polarity of the THz lightwave. These findings demonstrate a general pathway to designing metamaterial-based field-sensitive optical detectors suitable for the entire THz and IR spectral region.

42 ENGINEERING↗