Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

PathBot: A Radiology-Pathology Correlation Dashboard

Pathology is considered the “gold standard” of diagnostic medicine. The importance of radiology-pathology correlation is seen in interdepartmental patient conferences such as “tumor boards” and by the tradition of radiology resident immersion in a radiologic-pathology course at the American Institute of Radiologic Pathology. In practice, consistent pathology follow-up can be difficult due to time constraints and cumbersome electronic medical records. We present a radiology-pathology correlation dashboard that presents radiologists with pathology reports matched to their dictations, for both diagnostic imaging and image-guided procedures. In creating our dashboard, we utilized the RadLex ontology and National Center for Biomedical Ontology (NCBO) Annotator to identify anatomic concepts in pathology reports that could subsequently be mapped to relevant radiology reports, providing an automated method to match related radiology and pathology reports. Radiology-pathology matches are presented to the radiologist on a web-based dashboard. We found that our algorithm was highly specific in detecting matches. Our sensitivity was slightly lower than expected and could be attributed to missing anatomy concepts in the RadLex ontology, as well as limitations in our parent term hierarchical mapping and synonym recognition algorithms. By automating radiology-pathology correlation and presenting matches in a user-friendly dashboard format, we hope to encourage pathology follow-up in clinical radiology practice for purposes of self-education and to augment peer review. We also hope to provide a tool to facilitate the production of quality teaching files, lectures, and publications. Diagnostic images have a richer educational value when they are backed up by the gold standard of pathology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics-informed neural networks (PINNs) for fluid mechanics: a review

Despite the significant progress over the last 50 years in simulating flow problems using numerical discretization of the Navier–Stokes equations (NSE), we still cannot incorporate seamlessly noisy data into existing algorithms, mesh-generation is complex, and we cannot tackle high-dimensional problems governed by parametrized NSE. Moreover, solving inverse flow problems is often prohibitively expensive and requires complex and expensive formulations and new computer codes. Here, we review flow physics-informed learning, integrating seamlessly data and mathematical models, and implement them using physics-informed neural networks (PINNs). Here, we demonstrate the effectiveness of PINNs for inverse problems related to three-dimensional wake flows, supersonic flows, and biomedical flows.

42 ENGINEERING↗

A historical perspective on porphyrin-based metal–organic frameworks and their applications

Porphyrins are important molecules widely found in nature in the form of enzyme active sites and visible light absorption units. Recent interest in using these functional molecules as building blocks for the construction of metal–organic frameworks (MOFs) have rapidly increased due to the ease in which the locations of, and the distances between, the porphyrin units can be controlled in these porous crystalline materials. Porphyrin-based MOFs with atomically precise structures provide an ideal platform for the investigation of their structure–function relationships in the solid state without compromising accessibility to the inherent properties of the porphyrin building blocks. Here, this review will provide a historical overview of the development and applications of porphyrin-based MOFs from early studies focused on design and structures, to recent efforts on their utilization in biomimetic catalysis, photocatalysis, electrocatalysis, sensing, and biomedical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Dioxide Conversion to Nanomaterials: Methods, Applications, and Challenges

Anthropogenic carbon dioxide (CO 2 ) emission is one of the biggest global threats that we are confronted with in the 21st century. A lack of prompt action to mitigate the atmospheric CO 2 level could lead to global catastrophic events. As a result of the significance of the aforementioned threat, multiple nations have agreed to enact carbon capture, storage, utilization, and sequestration (CCUS) technologies at academic and industrial scales with the aim of lowering the atmospheric CO 2 level. Although there are many reviews on CCUS technologies, there is a lack of comprehensive review on CO 2 conversion to more economically valuable products, such as nanomaterials. Carbon dioxide capture and conversion into nanomaterials is an interesting research topic in many ways because it contributes to our fundamental knowledge of material conversion, provides alternative ways to reduce atmospheric pollution, and yields lucrative products, which has not been explored broadly. Aside from the positive outcomes, we have a moral obligation to rectify a global threat caused by anthropogenic emission. Herein, we present current methods of converting CO 2 into organic and inorganic nanomaterials with a focus on operating conditions and challenges as well as the potential of nanomaterials in specifically biomedical applications as opposed to extensively reviewed energy-related uses. Furthermore, our review emphasizes the toxicity issues related to using such nanomaterials in biological settings based on literature and other comparable studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the near-wall accumulation of injectable particles in the microcirculation: smaller is not better

Although most nanofabrication techniques can control nano/micro particle (NMP) size over a wide range, the majority of NMPs for biomedical applications exhibits a diameter of ,100 nm. Here, the vascular distribution of spherical particles, from 10 to 1,000 nm in diameter, is studied using intravital microscopy and computational modeling. Small NMPs (#100 nm) are observed to move with Red Blood Cells (RBCs), presenting an uniform radial distribution and limited near-wall accumulation. Larger NMPs tend to preferentially accumulate next to the vessel walls, in a size-dependent manner (,70% for 1,000 nm NMPs). RBC-NMP geometrical interference only is responsible for this behavior. In a capillary flow, the effective radial dispersion coefficient of 1,000 nm particles is ,3-fold larger than Brownian diffusion. This suggests that sub-micron particles could deposit within diseased vascular districts more efficiently than conventional nanoparticles.

BIOMEDICAL MATERIALS↗

High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. Lastly, the tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The PICASSO digital detector for Diffraction Enhanced Imaging at ELETTRA

A clinical mammography program is in progress at the medical beamline SYRMEP of the Italian synchrotron radiation laboratory ELETTRA in Trieste. A conventional screen-film system is utilized as detector for the examinations on patients. For the next experimental step a digital detector has been designed taking into account the essential requirements for mammography such as high spatial and contrast resolution, high efficiency for low dose examinations and high speed for short acquisition time. A double-layer prototype has already been tested in the frame of the PICASSO project. In addition, an analyzer crystal set-up for Diffraction Enhanced Imaging (DEI) has been available for many years at the SYRMEP beamline. Applying the DEI technique several successful experiments have been carried out in biomedical imaging and in particular in-vitro breast imaging utilizing commercially available detectors. Recently a system upgrade yielded a double-crystal analyzer set-up with improved stability and higher angular resolution. In this study the PICASSO detector has been utilized in combination with the new analyzer set-up for imaging in-vitro breast tissue samples. In order to test the potential of the combined system planar and tomographic images have been acquired and the first results are here presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wavelets in medical imaging

The aim of this study is to provide emerging applications of wavelet methods to medical signals and images, such as electrocardiogram, electroencephalogram, functional magnetic resonance imaging, computer tomography, X-ray and mammography. Interpretation of these signals and images are quite important. Nowadays wavelet methods have a significant impact on the science of medical imaging and the diagnosis of disease and screening protocols. Based on our initial investigations, future directions include neurosurgical planning and improved assessment of risk for individual patients, improved assessment and strategies for the treatment of chronic pain, improved seizure localization, and improved understanding of the physiology of neurological disorders. We look ahead to these and other emerging applications as the benefits of this technology become incorporated into current and future patient care. In this chapter by applying Fourier transform and wavelet transform, analysis and denoising of one of the important biomedical signals like EEG is carried out. The presence of rhythm, template matching, and correlation is discussed by various method. Energy of EEG signal is used to detect seizure in an epileptic patient. We have also performed denoising of EEG signals by SWT.

60 APPLIED LIFE SCIENCES↗

Engineering of gadofluoroprobes: Broad-spectrum applications from cancer diagnosis to therapy

The engineering of the Gadolinium based nanostructures have been demonstrated in this paper. Nanostructures of α-Gd{sub 2}S{sub 3} exhibit a unique transition between ferromagnetic state and paramagnetic state of the system. It was demonstrated that their properties could be tuned for a wide range of applications ranging from hyperthermia to Magnetic Resonance Imaging, owing to their magnetic moments and large relaxivities. Metallic Gd nanoparticles obtained by reduction method were employed for cancer imaging in mice. The Gd nanoparticles were coated with Curcumin and their biomedical implications in the field of simultaneous diagnosis and therapy of cancer and related diseases has been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner

In the field of biomedical X-ray imaging, novel techniques, such as phase-contrast and dark-field imaging, have the potential to enhance the contrast and provide complementary structural information about a specimen. In this paper, a first prototype of a preclinical X-ray phase-contrast CT scanner based on a Talbot-Lau interferometer is characterized. We present a study of the contrast-to-noise ratios for attenuation and phase-contrast images acquired with the prototype scanner. The shown results are based on a series of projection images and tomographic data sets of a plastic phantom in phase and attenuation-contrast recorded with varying acquisition settings. Subsequently, the signal and noise distribution of different regions in the phantom were determined. We present a novel method for estimation of contrast-to-noise ratios for projection images based on the cylindrical geometry of the phantom. Analytical functions, representing the expected signal in phase and attenuation-contrast for a circular object, are fitted to individual line profiles of the projection data. The free parameter of the fit function is used to estimate the contrast and the goodness of the fit is determined to assess the noise in the respective signal. The results depict the dependence of the contrast-to-noise ratios on the applied source voltages, the number of steps of the phase stepping routine, and the exposure times for an individual step. Moreover, the influence of the number of projection angles on the image quality of CT slices is investigated. Finally, the implications for future imaging purposes with the scanner are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoelastic sphenoscopic analysis of crystals

Birefringent crystals are at the basis of various devices used in many fields, from high energy physics to biomedical imaging for cancer detection. Since crystals are the main elements of those devices, a great attention is paid on their quality and properties. Here, we present a methodology for the photoelastic analysis of birefringent crystals, based on a modified polariscope. Polariscopes using conoscopic observation are used to evaluate crystals residual stresses in a precise but time consuming way; in our methodology, the light beam shape, which impinges on the crystal surface, has been changed from a solid cone (conoscopy) to a wedge (sphenoscopy). Since the polarized and coherent light is focused on a line rather than on a spot, this allows a faster analysis which leads to the observation, at a glance, of a spatial distribution of stress along a line. Three samples of lead tungstate crystals have been observed using this technique, and the obtained results are compared with the conoscopic observation. The samples have been tested both in unloaded condition and in a loaded configuration induced by means of a four points bending device, which allows to induce a known stress distribution in the crystal. The obtained results confirm, in a reliable manner, the sensitivity of the methodology to the crystal structure and stress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

25+2 poles, 4.3 T wiggler at BMIT – 7 years operational experience

The research program at the Biomedical Imaging and Therapy (BMIT) Facility at the Canadian Light Source (CLS) required a unique radiation source that would provide a wide beam fan with high critical energy and high dose rates. A superconductive wiggler was the only practical solution that could be installed inside the CLS ring. Design requirements were defined in 2005 [1-2]. The wiggler, optimized for a 3 GeV ring, was to match operating parameters of an equivalent hard X-ray source on a 6 GeV ring. Manufacturing started in 2006 and the wiggler was installed in November of 2007 [3-5]. Several modifications to external hardware and to the power supplies’ controls were implemented to address the air leaks into the He space and to provide the ability to change the field of the wiggler during normal operation without affecting other research groups. The original burst disk and pressure relief valves were replaced with commercial units. Most of the buna O-rings were replaced with metal O-rings, helping to provide air-tightness of external connections. Over the years, the nominal, no-load temperatures went up by 0.3 K at the LHe space and up by 4 K at the 50 K shield space due to deterioration of thermal links and insulation, resulting from thermal cycling and vibrations generated by cryo-coolers. In October of 2014 the wiggler went through major maintenance to improve the thermal links operation, to improve the LHe transfer line connection, to install additional heaters to mitigate potential ice growth, and to provide a separate exhaust path for the rupture disk port.

43 PARTICLE ACCELERATORS↗

Passive Inter-Photon Imaging

Digital camera pixels measure image intensities by converting incident light energy into an analog electrical current, and then digitizing it into a fixed-width binary representation. This direct measurement method, while conceptually simple, suffers from limited dynamic range and poor performance under extreme illumination --- electronic noise dominates under low illumination, and pixel full-well capacity results in saturation under bright illumination. We propose a novel intensity cue based on measuring inter-photon timing, defined as the time delay between detection of successive photons. Based on the statistics of inter-photon times measured by a time-resolved single-photon sensor, we develop theory and algorithms for a scene brightness estimator which works over extreme dynamic range; we experimentally demonstrate imaging scenes with a dynamic range of over ten million to one. The proposed techniques, aided by the emergence of single-photon sensors such as single-photon avalanche diodes (SPADs) with picosecond timing resolution, will have implications for a wide range of imaging applications: robotics, consumer photography, astronomy, microscopy and biomedical imaging.

97 MATHEMATICS AND COMPUTING↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Optical information transfer through random unknown diffusers using electronic encoding and diffractive decoding

Free-space optical information transfer through diffusive media is critical in many applications, such as biomedical devices and optical communication, but remains challenging due to random, unknown perturbations in the optical path. We demonstrate an optical diffractive decoder with electronic encoding to accurately transfer the optical information of interest, corresponding to, e.g., any arbitrary input object or message, through unknown random phase diffusers along the optical path. This hybrid electronic-optical model, trained using supervised learning, comprises a convolutional neural network-based electronic encoder and successive passive diffractive layers that are jointly optimized. After their joint training using deep learning, our hybrid model can transfer optical information through unknown phase diffusers, demonstrating generalization to new random diffusers never seen before. The resulting electronic-encoder and optical-decoder model was experimentally validated using a 3D-printed diffractive network that axially spans <70λ, where λ = 0.75 mm is the illumination wavelength in the terahertz spectrum, carrying the desired optical information through random unknown diffusers. The presented framework can be physically scaled to operate at different parts of the electromagnetic spectrum, without retraining its components, and would offer low-power and compact solutions for optical information transfer in free space through unknown random diffusive media.

36 MATERIALS SCIENCE↗

Coronary centerline extraction from CT coronary angiography images using a minimum cost path approach

Purpose: The application and large-scale evaluation of minimum cost path approaches for coronary centerline extraction from computed tomography coronary angiography (CTCA) data and the development and evaluation of a novel method to reduce the user-interaction time. Methods: A semiautomatic method based on a minimum cost path approach is evaluated for two different cost functions. The first cost function is based on a frequently used vesselness measure and intensity information, and the second is a recently proposed cost function based on region statistics. User interaction is minimized to one or two mouse clicks distally in the coronary artery. The starting point for the minimum cost path search is automatically determined using a newly developed method that finds a point in the center of the aorta in one of the axial slices. This step ensures that all computationally expensive parts of the algorithm can be precomputed. Results: The performance of the aorta localization procedure was demonstrated by a success rate of 100% in 75 images. The success rate and accuracy of centerline extraction was quantitatively evaluated on 48 coronary arteries in 12 images by comparing extracted centerlines with a manually annotated reference standard. The method was able to extract 88% and 47% of the vessel centerlines correctly using the vesselness/intensity and region statistics cost function, respectively. For only the proximal part of the vessels these values were 97% and 86%, respectively. Accuracy of centerline extraction, defined as the average distance from correctly automatically extracted parts of the centerline to the reference standard, was 0.64 mm for the vesselness/intensity and 0.51 mm for the region statistics cost function. The interobserver variability was 99% for the success rate measure and 0.42 mm for the accuracy measure. Qualitative evaluation using the best performing cost function resulted in successful centerline extraction for 233 out of the 252 coronaries (92%) in 63 additional CTCA images. Conclusions: The presented results, in combination with minimal user interaction and low computation time, show that minimum cost path approaches can effectively be applied as a preprocessing step for subsequent analysis in clinical practice and biomedical research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In vivo small animal imaging: Current status and future prospects

The use of small animal models in basic and preclinical sciences constitutes an integral part of testing new pharmaceutical agents prior to commercial translation to clinical practice. Whole-body small animal imaging is a particularly elegant and cost-effective experimental platform for the timely validation and commercialization of novel agents from the bench to the bedside. Biomedical imaging is now listed along with genomics, proteomics, and metabolomics as an integral part of biological and medical sciences. Miniaturized versions of clinical diagnostic modalities, including but not limited to microcomputed tomography, micromagnetic resonance tomography, microsingle-photon-emission tomography, micropositron-emission tomography, optical imaging, digital angiography, and ultrasound, have all greatly improved our investigative abilities to longitudinally study various experimental models of human disease in mice and rodents. After an exhaustive literature search, the authors present a concise and critical review of in vivo small animal imaging, focusing on currently available modalities as well as emerging imaging technologies on one side and molecularly targeted contrast agents on the other. Aforementioned scientific topics are analyzed in the context of cancer angiogenesis and innovative antiangiogenic strategies under-the-way to the clinic. Proposed hybrid approaches for diagnosis and targeted site-specific therapy are highlighted to offer an intriguing glimpse of the future.

60 APPLIED LIFE SCIENCES↗