Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EMPIRICAL VALIDATION OF BUILDING ENERGY SIMULATION SOFTWARE: ENERGYPLUS

This paper compares the results from a study conducted at Iowa Energy Center s Energy Resource Station with EnergyPlus simulation results. The building consists of controlled test rooms, dedicated air handling units and air-cooled chillers for the purpose of obtaining quality data suitable for empirical validation studies. Weather data were also collected at the facility and used for the simulation. Empirical validation can be performed on various levels of the program such as zone level, systems level, and plant level. This study is unique in the sense that it integrates the zones, system, and plant into one analysis. For this study, the difference between empirical and EnergyPlus predicted zone cooling loads varied from 1.7% to 10.2%, but the difference for the compressor power was as much as 22.4%. The paper also describes the potential reasons why simulation results might not match field data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗

Grey-box and ANN-based building models for multistep-ahead prediction of indoor temperature to implement model predictive control

Model-based predictive control (MPC) strategies for heating, ventilation, and air-conditioning (HVAC) systems present an opportunity to lower building energy consumption and operational costs. Such approaches rely on the development of a model to precisely forecast building thermal dynamics, such as room air temperature or heating/cooling rate, and make control-related decisions. The control-oriented modeling of building energy systems should be accurate in predicting indoor conditions and present low computational complexity. These features are the key challenge of implementing advanced control methods such as MPC. Extant studies on building modeling for MPC have focused on step-ahead forecasting techniques to forecast building thermal dynamics, while multistep-ahead forecasting is essential. Moreover, machine learning model suitable in case of the domain-based engineering expertise are also not available. To this aim, we perform a comparative analysis of the grey-box model based on a resistance-capacitance (RC) thermal network and a machine learning model composed of an artificial neural network (ANN) for multistep-ahead prediction of building thermal dynamics using current and historical data. Actual experimental data obtained from the Flexible Research Platform (FRP) in Oak Ridge National Laboratory (US) are used for estimation and validation purposes. The average root mean squared error (RMSE) of the grey-box and ANN models are 0.89 °C and 1.02°C, respectively. Finally, the results indicate that the grey-box model outperforms the ANN model in the considered validation periods in terms of accuracy and prediction stability.

42 ENGINEERING↗

A low-cost centralized HVAC control system solution for energy savings, load shedding, and improved maintenance

University campuses rely on centralized controls for managing and optimizing complex HVAC systems in larger buildings. However, most campuses also have many smaller buildings with packaged HVAC systems controlled by a stand-alone thermostat. Even when these distributed and often overlooked systems have modern programmable thermostats, they cannot be centrally monitored or controlled, and they are typically not programmed adequately. This paper describes the implementation of a low-cost centralized control solution for these systems serving smaller campus buildings, mostly under 5,000 sf and representative of light commercial spaces. Thanks to advances in technology spurred by residential and commercial IoT developments, simple networked thermostat solutions exist that can easily replace original thermostats, and, connect these systems to a web-based portal for monitoring and control. We show that, with small customizations, these platforms can be integrated into facility management workflows. Beyond the energy savings potential from improved scheduling and closer management of these systems, there are significant advantages for maintenance crews since these systems can now be monitored on smart phones or tablets. A grid-responsive load-shedding program has also been implemented for additional cost savings. The networked thermostats can also be connected to additional systems such as economizer controls for improved ventilation management and energy savings. With data from these systems integrated centrally, it can also be used for improved analytics and fault detection. A toolkit has been developed to share the program with other campuses, whether for energy savings, improved management of ventilation, or a more proactive maintenance approach.

Fauchier-Magnan, Nicolas↗

Dual-Zone Solar Control Indoor Shade: Demonstration at the Ronald V. Dellums Federal Building and U.S. Courthouse, 1301 Clay Street, Oakland, California and the Lawrence Berkeley National Laboratory Advanced Windows Testbed, Berkeley, California

Standard window shades are used to control sunlight, glare, window heat gains, and daylight. The challenge with conventional shades is that once the shades are lowered to reduce discomfort, daylight is reduced, which, in turn, increases the need for electric lighting. View is also obstructed, reducing the occupants’ connection to the outdoors. The strategy of subdividing the window wall and admitting daylight from above and controlling sunlight and view through the lower aperture can yield significant energy and peak demand savings over conventional shading systems, and improve the daylight quality of the indoor environment. This study evaluated a dual zone solar control (DZSC) shade with an upper, automated, horizontal, venetian blind with concave-up, matte white slats and a lower, manually operated, roller shade made of a transparent, reflective film. The automatic controls were designed to adjust the upper slat angle to maximize daylight to the room interior. The lower shade, when lowered, provided an unobstructed view to the outdoors. For the qualitative analysis, the DZSC shades were installed on windows in the southeast half of one floor in the Ronald V. Dellums Federal Building and U.S. Courthouse or hereafter referred to as the Oakland Federal Building (OFB) in Oakland, California. The position of the DZSC shades were observed and recorded periodically. Surveys were issued to occupants in the private offices and open plan workstations affected by the shades. For the quantitative analysis, the DZSC shades were installed in the south-facing windows of thermally isolated, fully instrumented, test chambers in the Advanced Windows Testbed at the Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California. Measurements of window heat loads, daylight illuminance and environmental conditions related to visual and thermal comfort were collected over a six-month, solstice-to-solstice period. The performance of the DZSC shade was compared to fabric roller shades and venetian blinds since these are the two most common types of shades used in both commercial and Federal buildings. Several DZSC design permutations were evaluated: 1) manual or automated control of the upper louver system (“man” or “auto”) and 2) tinted or silvered reflective film for the lower shade (“Gray-Gray (GG)” or “Gray-Silver (GS)”1). The automated, reflective shade (auto-GS) reduced dimmable fluorescent lighting energy use by 51% and window cooling load by 13-15% compared to a conventional fabric roller shade with dual-pane, spectrally selective, low-e windows during the summer period (winter period was not measured). Qualitative analysis revealed that the auto-GS shade was preferred by 80% of the survey respondents compared to the existing vertical fabric blinds with single-pane, tinted windows in the occupied building. Survey results indicated that visual discomfort was reduced and thermal discomfort was also reduced during warm or hot weather. Occupants expressed greater satisfaction with the unobstructed view. Installation and commissioning of the DZSC shades was fairly straightforward with some minor problems due to inadequate installation instructions and improper wiring. A few occupants expressed dissatisfaction with the automatic controls for the upper louvers due to visual discomfort, erroneous control, and motor noise.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation of Energy Management Systems in EnergyPlus

An energy management system (EMS) is a dedicated computer that can be programmed to control all of a building's energy-related systems, including heating, cooling, ventilation, hot water, interior lighting, exterior lighting, on-site power generation, and mechanized systems for shading devices, window actuators, and double facade elements. Recently a new module for simulating an EMS was added to the EnergyPlus whole-building energy simulation program. An essential part of the EMS module is the EnergyPlus Runtime Language (ERL), which is a simple programming language that is used to specify the EMS control algorithms. The new EMS controls and the flexibility of ERL allow EnergyPlus to simulate many novel control strategies that are not possible with the previous generation of building energy simulation programs. This paper surveys the standard controls in EnergyPlus, presents the new EMS features, describes the implementation of the module, and explores some of the possible applications for the new EMS capabilities in EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

Remote Monitoring System Design Requirements for Accountable Nuclear Materials at the Nevada National Security Site

The Nevada National Security Site (NNSS) worked with other sites within the Department of Energy National Nuclear Security Administration weapons complex to develop design requirements for a Remote Monitoring System. System objectives included: Continuous monitoring of packaging (containers) within a Facility's buildings to meet Material Control and Accountability (MC&A) inventory requirements. Remotely access and receive monitoring data for tamper detection/alarm, tracking information, environmental conditions, equipment metadata (serial number, date of manufacture, etc.), and assessment video feeds. All data processing, storage/retrieval, and communications will be protected in a manner commensurate with its trust level and classification. Remotely collected and processed data will be securely stored, backed up, and archived. Current and historical data will accessible within and outside of a Building (location). Automated creation of reports and data visualization. Design features to facilitate the potential future integration with the Facility's physical security alarm and display system. The requirements may be used to develop an integrated conceptual design or may be used in a modular fashion to inform separate designs. The guiding principles in developing the system objectives include: For MC&A needs, remotely perform the physical inventory and evidence collection of tamper for Security Category I and II packaged material within a facility and be capable of satisfying guidelines establish by DOE M 470.4-6, “Nuclear Material Control and Accountability.” For personnel safety needs: Meet/satisfy Nuclear Explosive Safety requirements. Minimize the exposure of personnel to radiation to be as low as reasonably achievable (ALARA) in accordance with NSTec Radiological Controls Manual. For DOE nuclear materials, Building environment shall be controlled to meet requirements for packaged nuclear materials specified in weapons laboratory literature.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-Assembly of Quantum Dot–Gold Heterodimer Nanocrystals with Orientational Order

The self-assembly of nanocrystals into ordered superlattices is a powerful strategy for the production of functional nanomaterials. The assembly of well-ordered target structures, however, requires control over the building blocks’ size and shape as well as their interactions. While nanocrystals with homogeneous composition are now routinely synthesized with high precision and assembled into various ordered structures, high-quality multicomponent nanocrystals and their ordered assemblies are rarely reported. In this paper, we demonstrate the synthesis of quantum dot–gold (QD-Au) heterodimers. These heterodimers possess a uniform shape and narrow size distribution and are capped with oleylamine and dodecyltrimethylammonium bromide (DTAB). Assembly of the heterodimers results in a superlattice with long-range orientational alignment of dimers. Using synchrotron-based X-ray measurements, we characterize the complex superstructure formed from the dimers. Molecular dynamics simulations of a coarse-grained model suggest that anisotropic interactions between the quantum dot and gold components of the dimer drive superlattice formation. The high degree of orientational order demonstrated in this work is a potential route to nanomaterials with useful optoelectronic properties.

36 MATERIALS SCIENCE↗

High frequency beam oscillation keyhole dynamics in laser melting revealed by in-situ x-ray imaging

The metal additive manufacturing industry is actively developing instruments and strategies to enable higher productivity, optimal build quality, and controllable as-built microstructure. A beam controlling technique, laser oscillation has shown potential in all these aspects in laser welding; however, few attempts have been made to understand the underlying physics of the oscillating keyholes/melt pools which are the prerequisites for these strategies to become a useful tool for laser-based additive manufacturing processes. Here, to address this gap, we utilized a synchrotron-based X-ray operando technique to image the dynamic keyhole oscillation in Ti-6Al-4V using a miniature powder bed fusion setup. We found good agreement between the experimental observations and simulations performed with a validated Lattice Boltzmann multiphysics model. The study revealed the continuous and periodic fluctuations in the characteristic keyhole parameters that are unique to the oscillating laser beam processing and responsible for the chevron pattern formation at solidification. In particular, despite the intrinsic longer-range fluctuation, the oscillating technique displayed potential for reducing keyhole instability, mitigating porosity formation, and altering surface topology. These insights on the oscillating keyhole dynamics can be useful for the future development and application of this technique.

36 MATERIALS SCIENCE↗

New risk metrics and mathematical tools for risk analysis: Current and future challenges

The current status of the food safety supply world wide, has led Food and Agriculture Organization (FAO) and World Health Organization (WHO) to establishing Risk Analysis as the single framework for building food safety control programs. A series of guidelines and reports that detail out the various steps in Risk Analysis, namely Risk Management, Risk Assessment and Risk Communication is available. The Risk Analysis approach enables integration between operational food management systems, such as Hazard Analysis Critical Control Points, public health and governmental decisions. To do that, a series of new Risk Metrics has been established as follows: i) the Appropriate Level of Protection (ALOP), which indicates the maximum numbers of illnesses in a population per annum, defined by quantitative risk assessments, and used to establish; ii) Food Safety Objective (FSO), which sets the maximum frequency and/or concentration of a hazard in a food at the time of consumption that provides or contributes to the ALOP. Given that ALOP is rather a metric of the public health tolerable burden (it addresses the total ‘failure’ that may be handled at a national level), it is difficult to be interpreted into control measures applied at the manufacturing level. Thus, a series of specific objectives and criteria for performance of individual processes and products have been established, all of them assisting in the achievement of FSO and hence, ALOP. In order to achieve FSO, tools quantifying the effect of processes and intrinsic properties of foods on survival and growth of pathogens are essential. In this context, predictive microbiology and risk assessment have offered an important assistance to Food Safety Management. Predictive modelling is the basis of exposure assessment and the development of stochastic and kinetic models, which are also available in the form of Web-based applications, e.g., COMBASE and Microbial Responses Viewer), or introduced into user-friendly softwares, (e.g., Seafood Spoilage Predictor) have evolved the use of information systems in the food safety management. Such tools are updateable with new food-pathogen specific models containing cardinal parameters and multiple dependent variables, including plate counts, concentration of metabolic products, or even expression levels of certain genes. Then, these tools may further serve as decision-support tools which may assist in product logistics, based on their scientifically-based and “momentary” expressed spoilage and safety level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Planet traps and planetary cores: origins of the planet-metallicity correlation

Massive exoplanets are observed preferentially around high metallicity ([Fe/H]) stars while low-mass exoplanets do not show such an effect. This so-called planet-metallicity correlation generally favors the idea that most observed gas giants at r < 10 AU are formed via a core accretion process. We investigate the origin of this phenomenon using a semi-analytical model, wherein the standard core accretion takes place at planet traps in protostellar disks where rapid type I migrators are halted. We focus on the three major exoplanetary populations—hot Jupiters, exo-Jupiters located at r ≅ 1 AU, and the low-mass planets. We show using a statistical approach that the planet-metallicity correlations are well reproduced in these models. We find that there are specific transition metallicities with values [Fe/H] = –0.2 to –0.4, below which the low-mass population dominates, and above which the Jovian populations take over. The exo-Jupiters significantly exceed the hot Jupiter population at all observed metallicities. The low-mass planets formed via the core accretion are insensitive to metallicity, which may account for a large fraction of the observed super-Earths and hot-Neptunes. Finally, a controlling factor in building massive planets is the critical mass of planetary cores (M {sub c,} {sub crit}) that regulates the onset of rapid gas accretion. Assuming the current data is roughly complete at [Fe/H] > –0.6, our models predict that the most likely value of the 'mean' critical core mass of Jovian planets is (M {sub c,} {sub crit}) ≅ 5 M {sub ⊕} rather than 10 M {sub ⊕}. This implies that grain opacities in accreting envelopes should be reduced in order to lower M {sub c,} {sub crit}.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrastructure first principles for the Anthropocene

Abstract There appears to be a growing decoupling between the conditions that infrastructures were designed for and today’s rapidly changing environments. Infrastructures today are largely predicated on the technologies, goals, and governance structures from a century ago. While infrastructures continue to deliver untold value, there is growing evidence that these critical, basic, and lifeline systems appear ill-equipped to confront the volatility, uncertainty, accelerating conditions, and complexity that define them and their changing environments. Innovative and disruptive first principles are needed to guide infrastructures in the Anthropocene. Drawing from emerging infrastructure research and disciplines that appear better able to confront disruption and change, a novel set of first principles are identified: (1) Plan for complex conditions and surprise; (2) Recouple with agility and flexibility; (3) Govern for exploration and instability; (4) Build consensus as control decentralizes; (5) Restructure to engage with porous boundaries; and, (6) Cyberthreat planning is now mission critical. These principles should guide infrastructure planning recognizing the changing nature and increasingly obsolete boundaries that have defined engineered systems in the modern era.

Chester, Mikhail (ORCID:0000000293542102)↗

Signal Temporal Logic Control for Residential HVAC Systems to Accommodate High Solar PV Penetration

This paper proposes a new signal temporal logic (STL) control for ON/OFF residential buildings' Heating Ventilation and Air Conditioning (HVAC) systems. STL is used to control indoor temperatures while consuming most of the generated solar photovoltaic (PV) power locally to minimize its impact on the grid and reduce the need for large energy storage devices. In contrast to most, if not all, control mechanisms such as the traditional model predictive control (MPC), STL control allows for including temporal constraints in the control formulation to further relax indoor temperatures' constraints and allow them to exceed the comfort band limits for a prespecified (short) period of time. This relaxation allows to consume an additional PV power by the HVAC systems, which prevents such an unwanted intermittent power from affecting the grid. We formulate the MPC-based STL control mechanism to implement the objective. Simulation results show that the PV tracking performance has been improved while employing the proposed STL controller.

Wu, Tumin↗