Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Design and Performance of Kokkos Staging Space toward Scalable Resilient Application Couplings

With the growing number of applications designed for heterogeneous HPC devices, application programmers and users are finding it challenging to compose scalable workflows as ensembles of these applications, that are portable, performant and resilient. The Kokkos C++ library has been designed to simplify this cumbersome procedure by providing an intra-application uniform programming model and portable performance. However, assembling multiple Kokkos-enabled applications into a complex workflow is still a challenge. Although Kokkos enables a uniform programming model, the inter-application data exchange still remains a challenge from both performance and software development cost perspectives. In order to address this issue, we propose Kokkos data staging memory space, an extension of Kokkos' data abstraction (memory space) for heterogeneous computing systems. This new abstraction allows to express data on a virtual shared-space for multiple Kokkos applications, thus extending Kokkos to support inter-application data exchange to build an efficient application workflow. Additionally, we study the effectiveness of asynchronous data layout conversions for applications requiring different memory access patterns for the shared data. Our preliminary evaluation with a synthetic benchmark indicate the effectiveness of this conversion adapted to three different scenarios representing access frequency and use patterns of the shared data.

97 MATHEMATICS AND COMPUTING↗

A Comprehensive Comparison of Building Height Products at a Global Level

The built environment continues to expand due to increasing human populations with some projections indicating additional growth of 2.5 billion persons by 2050. Buildings are a key component of the built environment and information on building height and urban morphology in general can help to better understand and address a host of development and urban planning issues including energy consumption, urbanization, population dynamics, urban heat islands, environmental degradation, and others. To date, several approaches have been developed to address the need for mapping building height at scale. These approaches can be grouped into two main categories: 1) directly measure height from remote sensing products or 2) indirectly estimate height from footprint morphology features at the building-by-building level. Due to a number of these global height datasets now being available for consumption and use across domains, there is a critical need to understand the differences displayed between these products and how the use of these may influence the outcome when applied. In this analysis, we compare and evaluate 5 global building height datasets: Global Human Settlement, World Settlement Footprint 3D, Global Building Morphology dataset, three-dimensional Global Building Footprints, and an approach developed at Oak Ridge National Laboratory (ORNL). Our analysis shows that, across 5 cities at a global scale with high-quality building height reference data, the approach developed by ORNL of inferring height at the building-by-building level is more accurate and consistent. This was evidenced by the ORNL product improving upon the baseline in all 5 cities, the only product to do so. These findings will aid researchers in choosing a global building height product that best meets their needs and provides global availability, consistency, and accuracy.

42 ENGINEERING↗

Minimum Hamiltonian ascent trajectory evaluation (MASTRE) program (update to automatic flight trajectory design, performance prediction, and vehicle sizing for support of shuttle and shuttle derived vehicles) users manual

Documentation for the User Interface Program for the Minimum Hamiltonian Ascent Trajectory Evaluation (MASTRE) is provided. The User Interface Program is a separate software package designed to ease the user input requirements when using the MASTRE Trajectory Program. This document supplements documentation on the MASTRE Program that consists of the MASTRE Engineering Manual and the MASTRE Programmers Guide. The User Interface Program provides a series of menus and tables using the VAX Screen Management Guideline (SMG) software. These menus and tables allow the user to modify the MASTRE Program input without the need for learning the various program dependent mnemonics. In addition, the User Interface Program allows the user to modify and/or review additional input Namelist and data files, to build and review command files, to formulate and calculate mass properties related data, and to have a plotting capability.

Lyons, J. T.↗

Building a COTS archive for satellite data

The goal of the NOAA/NESDIS Active Archive was to provide a method of access to an online archive of satellite data. The archive had to manage and store the data, let users interrogate the archive, and allow users to retrieve data from the archive. Practical issues of the system design such as implementation time, cost and operational support were examined in addition to the technical issues. There was a fixed window of opportunity to create an operational system, along with budget and staffing constraints. Therefore, the technical solution had to be designed and implemented subject to constraint imposed by the practical issues. The NOAA/NESDIS Active Archive came online in July of 1994, meeting all of its original objectives.

Singer, Ken↗

Peak Satellite-to-Earth Data Rates Derived From Measurements of a 20 Gbps Bread-Board Modem

A prototype data link using a Ka-band space qualified, high efficiency 200 W TWT amplifier and a bread-board modem emulator were created to explore the feasibility of very high speed communications in satellite-to-earth applications. Experiments were conducted using a DVB-S2-like waveform with modifications to support up to 20 Gbps through the addition of 128-Quadrature Amplitude Modulation (QAM). Limited by the bandwidth of the amplifier, a constant peak symbol rate of 3.2 Giga-symbols/sec was selected and the modulation order was varied to explore what peak data rate might be supported by an RF link through this amplifier. Using 128-QAM, an implementation loss of 3 dB was observed at 20 Gbps, and the loss decreased as data rate or bandwidth were reduced. Building on this measured data, realistic link budget calculations were completed. Low-Earth orbit (LEO) missions based on this TWTA with reasonable hardware assumptions and antenna sizing are found to be bandwidth-limited, rather than power-limited, making the spectral efficiency of 9/10-rate encoded 128-QAM very attractive. Assuming a bandwidth allocation of 1 GHz, these computations indicate that low-Earth orbit vehicles could achieve data rates up to 5 Gbps-an order of magnitude beyond the current state-of-practice, yet still within the processing power of a current FPGA-based software-defined modem. The measured performance results and a description of the experimental setup are presented to support these conclusions.

Landon, David G.↗

Building A Cloud Based Distributed Active Data Archive Center

NASA's Earth Science Data System (ESDS) Program facilitates the implementation of NASA's Earth Science strategic plan, which is committed to the full and open sharing of Earth science data obtained from NASA instruments to all users. The Earth Science Data information System (ESDIS) project manages the Earth Observing System Data and Information System (EOSDIS). Data within EOSDIS are held at Distributed Active Archive Centers (DAACs). One of the key responsibilities of the ESDS Program is to continuously evolve the entire data and information system to maximize returns on the collected NASA data.

Earth Science Informatics↗

Technology Solutions Case Study: Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

BA-PIRC↗

Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed office buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.

code compliance↗

Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed office buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.

code compliance, commercial energy code, energy co↗

Building Battery Energy Storage System Performance Data into an Economic Assessment

Economic assessments of battery energy storage systems (BESSs) rely on optimal dispatch methods to capture temporal interdependency of BESS operations and coupling among different grid applications. Many existing BESS economic assessment studies are based on a simplified first-order scalar model using BESS nameplate numbers. Such a method cannot accurately capture varying capabilities and nonlinear dynamics of a BESS, leading to inaccurate assessment results. This paper presents a practical implementation of performance data into the economic assessment of the BESSs recently developed within the Snohomish Public Utility District system in Washington State. Extensive testing conducted over multiple seasons is used to assess the technical performance and develop high-fidelity models of the BESSs. A dynamic programming algorithm is proposed to optimally dispatch the BESSs and assess the potential benefits from stacked value streams. The proposed method can be adapted for the economic assessment of other BESSs with different applications.

Wu, Di↗

Hardware-Based Emulator with Deep Learning Model for Building Energy Control and Prediction Based on Occupancy Sensors’ Data

Heating, ventilation, and air conditioning (HVAC) is the largest source of residential energy consumption. Occupancy sensors’ data can be used for HVAC control since it indicates the number of people in the building. HVAC and sensors form a typical cyber-physical system (CPS). In this paper, we aim to build a hardware-based emulation platform to study the occupancy data’s features, which can be further extracted by using machine learning models. In particular, we propose two hardware-based emulators to investigate the use of wired/wireless communication interfaces for occupancy sensor-based building CPS control, and the use of deep learning to predict the building energy consumption with the sensor data. We hypothesize is that the building energy consumption may be predicted by using the occupancy data collected by the sensors, and question what type of prediction model should be used to accurately predict the energy load. Another hypothesis is that an in-lab hardware/software platform could be built to emulate the occupancy sensing process. The machine learning algorithms can then be used to analyze the energy load based on the sensing data. To test the emulator, the occupancy data from the sensors is used to predict energy consumption. The synchronization scheme between sensors and the HVAC server will be discussed. We have built two hardware/software emulation platforms to investigate the sensor/HVAC integration strategies, and used an enhanced deep learning model—which has sequence-to-sequence long short-term memory (Seq2Seq LSTM)—with an attention model to predict the building energy consumption with the preservation of the intrinsic patterns. Because the long-range temporal dependencies are captured, the Seq2Seq models may provide a higher accuracy by using LSTM architectures with encoder and decoder. Meanwhile, LSTMs can capture the temporal and spatial patterns of time series data. The attention model can highlight the most relevant input information in the energy prediction by allocating the attention weights. The communication overhead between the sensors and the HVAC control server can also be alleviated via the attention mechanism, which can automatically ignore the irrelevant information and amplify the relevant information during CNN training. Our experiments and performance analysis show that, compared with the traditional LSTM neural network, the performance of the proposed method has a 30% higher prediction accuracy.

Ye, Zhijing↗

Corresponding Standard Reference Material Data used in Partial Least Squares Regression Models for Sugar Composition Estimates in Biomass in: Economic Impact of Yield and Composition Variation in Bioenergy Crops: Populus trichocarpa

Corresponding Standard Reference Material Data used in Partial Least Squares Regression Models for Sugar Composition Estimates in Biomass in: Economic Impact of Yield and Composition Variation in Bioenergy Crops: Populus trichocarpa (for corresponding manuscript: DOI: 10.1002/bbb.2148) PDF Files: Images of 1H NMR spectra for neutralized 2-stage acid hydrolysates of 4 NIST Standard Reference Material biomass samples (Monterey Pine 8493, Sugarcane Bagasse 8491, Wheat Straw 8494, and Eastern Cottonwood/Poplar 8492) and 2 Center for Bioenergy Innovation reference biomass samples (Poplar - Populus trichocarpa and Switchgrass - Panicum Virgatum). Suppression of the water peak was achieved using a NOESY-1D with presaturation, a recycle delay of 5 s, and a total of 64 scans. Spectra were acquired at 298 K and processed with automatic phase correction, baseline correction, and chemical shift referencing to TSP-d4. Images show all 1H data from 10 to 1ppm with inset spectra of region of interest (4.0 to 3.1 ppm). Text Files: Spectra for neutralized 2-stage acid hydrolysates of 4 NIST Standard Reference Material biomass samples (Monterey Pine 8493, Sugarcane Bagasse 8491, Wheat Straw 8494, and Eastern Cottonwood/Poplar 8492) and 2 Center for Bioenergy Innovation reference biomass samples (Poplar - Populus trichocarpa and Switchgrass - Panicum Virgatum) were converted into text files for plotting. Files contain 8192 points of raw spectral data from 12.23 to -2.78 ppm. The text file contains 4 columns of data and includes: Point number, Intensity, Hz, and ppm. Xcel Spreadsheet: HPLC measured monomeric sugar concentrations and bucketed 1H NMR data used to build monomeric sugar composition prediction models. Sugar composition in biomass determined from HPLC analyses are given in mg sugar/mg of biomass. Spectral bucketing was performed using Bruker’s AMIX software. Spectra were divided into 0.005 ppm buckets in the region of 3.10– 4.15 ppm for a total of 210 buckets. Headers for the bucketed data are the chemical shift in ppm of the center of the bucket. Bucketed data was used to build partial least squares models for subsequent predictions in The Unscrambler v. 10.5(CAMO A/S, Trondheim, Norway). The formation of methanol during hydrolysis interferes with the quantitative NMR analysis of sugars, so the methanol peak centered at 3.37 ppm and spanning four buckets (3.2925 – 3.2775 ppm) was set to zero for all spectra.

09 BIOMASS FUELS↗

Understanding the U.S. Commercial Building Stock: Building Envelope and HVAC Systems Characteristics Using 2012 CBECS Data Analysis

The U.S. Department of Energy (DOE) and its national labs developed a series of commercial reference building models in 2007. Over the past decade, the Pacific Northwest National Laboratory, in support of DOE’s Building Energy Codes Program, expanded these prototype building models to comply with multiple editions of national model codes and standards, including both ASHRAE Standard 90.1 and International Energy Conservation Code. The prototype building models established a credible foundation to develop new requirements in building codes and standards, track progress of codes and standards, and evaluate the energy saving potential of new technologies or systems in the commercial building sector. The 2003 Commercial Building Energy Consumption Survey (CBECS) was the primary data source used to develop the original models. Given the recent release of 2012 CBECS data, this paper characterizes the most representative design choices for building envelope and HVAC systems in recently-constructed commercial buildings. The results from this analysis provide actionable insight for future commercial building research in reflection of recent construction practices.

energy efficiency, building energy codes, CBECS, b↗

Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings

California is a leader in automating demand response (DR) to promote low-cost, consistent, and predictable electric grid management tools. Over 250 commercial and industrial facilities in California participate in fully-automated programs providing over 60 MW of peak DR savings. This paper presents a summary of Open Automated DR (OpenADR) implementation by each of the investor-owned utilities in California. It provides a summary of participation, DR strategies and incentives. Commercial buildings can reduce peak demand from 5 to 15percent with an average of 13percent. Industrial facilities shed much higher loads. For buildings with multi-year savings we evaluate their load variability and shed variability. We provide a summary of control strategies deployed, along with costs to install automation. We report on how the electric DR control strategies perform over many years of events. We benchmark the peak demand of this sample of buildings against their past baselines to understand the differences in building performance over the years. This is done with peak demand intensities and load factors. The paper also describes the importance of these data in helping to understand possible techniques to reach net zero energy using peak day dynamic control capabilities in commercial buildings. We present an example in which the electric load shape changed as a result of a lighting retrofit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nationwide Buildings Energy Research enabled through an integrated Data Intensive Scientific Workflow and Advanced Analysis Environment

Modern workflow systems enable scientists to run ensemble simulations at unprecedented scales and levels of complexity, allowing them to study system sizes previously impossible to achieve, due to the inherent resource requirements needed for the modeling work. However as a result of these new capabilities the science teams suddenly also face unprecedented data volumes that they are unable to analyze with their existing tools and methodologies in a timely fashion. In this paper we will describe the ongoing development work to create an integrated data intensive scientific workflow and analysis environment that offers researchers the ability to easily create and execute complex simulation studies and provides them with different scalable methods to analyze the resulting data volumes. The integration of simulation and analysis environments is hereby not only a question of ease of use, but supports fundamental functions in the correlated analysis of simulation input, execution details and derived results for multi-variant, complex studies. To this end the team extended and integrated the existing capabilities of the Velo data management and analysis infrastructure, the MeDICi data intensive workflow system and RHIPE the R for Hadoop version of the well-known statistics package, as well as developing a new visual analytics interface for the result exploitation by multi-domain users. The capabilities of the new environment are demonstrated on a use case that focusses on the Pacific Northwest National Laboratory (PNNL) building energy team, showing how they were able to take their previously local scale simulations to a nationwide level by utilizing data intensive computing techniques not only for their modeling work, but also for the subsequent analysis of their modeling results. As part of the PNNL research initiative PRIMA (Platform for Regional Integrated Modeling and Analysis) the team performed an initial 3 year study of building energy demands for the US Eastern Interconnect domain, which they are now planning to extend to predict the demand for the complete century. The initial study raised their data demands from a few GBs to 400GB for the 3year study and expected tens of TBs for the full century.

99 GENERAL AND MISCELLANEOUS↗

Building Efficiency Targeting Tool for Energy Retrofits (BETTER) Analytical Engine

This is an open-source, empirical data-driven, virtual building energy analysis and retrofit targeting tool. The open-source tool will provide a fully-automated, "no-cost/no-touch" approach to screen large volumes of buildings for operational improvement and equipment upgrade opportunities and quantify associated potential energy and cost savings.

Szum, Carolyn↗