At least 793 records · Page 44

Boundary-layer transition and global skin friction measurement with an oil-fringe imaging technique

A new oil-fringe imaging system skin friction (FISF) technique to measure skin friction on wind tunnel models is presented. In the method used to demonstrate the technique, lines of oil are applied on surfaces that connect the intended sets of measurement points, and then a wind tunnel is run so that the oil thins and forms interference fringes that are spaced in proportion to local skin friction. After a run the fringe spacings are imaged with a CCD-array digital camera and measured on a computer. Skin friction and transition measurements on a two-dimensional wing are presented and compared with computational predictions.

Monson, Daryl J.↗

Boundary-layer transition and global skin friction measurement with an oil-fringe imaging technique

A new oil-fringe imaging fkin friction (FISF) technique to measure skin friction on wind tunnel models is presented. In the method used to demonstrate the technique, lines of oil are applied on surfaces that connect the intended sets of measurement points, and then a wind tunnel is run so that the oil thins and forms interference fringes that are spaced proportional to local skin friction. After a run the fringe spacings are imaged with a CCD-array digital camera and measured on a computer. Skin friction and transition measurements on a two-dimensional wing are presented and compared with computational predictions.

Monson, Daryl J.↗

Advanced Video Data-Acquisition System For Flight Research

Advanced video data-acquisition system (AVDAS) developed to satisfy variety of requirements for in-flight video documentation. Requirements range from providing images for visualization of airflows around fighter airplanes at high angles of attack to obtaining safety-of-flight documentation. F/A-18 AVDAS takes advantage of very capable systems like NITE Hawk forward-looking infrared (FLIR) pod and recent video developments like miniature charge-couple-device (CCD) color video cameras and other flight-qualified video hardware.

Miller, Geoffrey↗

Development of a Sunspot Tracking System

Large solar flares produce a significant amount of energetic particles which pose a hazard for human activity in space. In the hope of understanding flare mechanisms and thus better predicting solar flares, NASA's Marshall Space Flight Center (MSFC) developed an experimental vector magnetograph (EXVM) polarimeter to measure the Sun's magnetic field. The EXVM will be used to perform ground-based solar observations and will provide a proof of concept for the design of a similar instrument for the Japanese Solar-B space mission. The EXVM typically operates for a period of several minutes. During this time there is image motion due to atmospheric fluctuation and telescope wind loading. To optimize the EXVM performance an image motion compensation device (sunspot tracker) is needed. The sunspot tracker consists of two parts, an image motion determination system and an image deflection system. For image motion determination a CCD or CID camera is used to digitize an image, than an algorithm is applied to determine the motion. This motion or error signal is sent to the image deflection system which moves the image back to its original location. Both of these systems are under development. Two algorithms are available for sunspot tracking which require the use of only one row and one column of image data. To implement these algorithms, two identical independent systems are being developed, one system for each axis of motion. Two CID cameras have been purchased; the data from each camera will be used to determine image motion for each direction. The error signal generated by the tracking algorithm will be sent to an image deflection system consisting of an actuator and a mirror constrained to move about one axis. Magnetostrictive actuators were chosen to move the mirror over piezoelectrics due to their larger driving force and larger range of motion. The actuator and mirror mounts are currently under development.

Taylor, Jaime R.↗

Marshall Space Flight Center's Tower Vector Magnetograph: Upgrades, Hardware, and Operations for the HESSI Mission

The Marshall Space Flight Center's (MSFC) solar group announces the successful upgrade of our tower vector magnetograph. In operation since 1973, the last major alterations to the system (which includes telescope, filter, polarizing optics, camera, and data acquisition computer) were made in 1982, when we upgraded from an SEC Vidicon camera to a CCD. In 1985, other changes were made which increased the field-of-view from 5 x 5 arc min (2.4 arc sec per pixel) to 6 x 6 arc min with a resolution of 2.81 arc sec. In 1989, the Apollo Telescope Mount H-alpha telescope was coaligned with the optics of the magnetograph. The most recent upgrades (year 2000), funded to support the High Energy Solar Spectroscopic Imager (HESSI) mission, have resulted in a pixel size of 0.64 arc sec over a 7 x 5.2 arc min field-of-view (binning 1x1). This poster describes the physical characteristics of the new system and compares spatial resolution, timing, and versatility with the old system. Finally, we provide a description of our Internet web site, which includes images of our most recent observations, and links to our data archives, as well as the history of magnetography at MSFC and education outreach pages.

Adams, M. L.↗

Anisotropic Decomposition of Energetic Materials

Using a white x-ray synchrotron beam, we have dynamically studied radiation-induced decomposition in single crystalline PETN and TATB. By monitoring the integrated intensity of selected diffraction spots via a CCD x-ray camera as a function of time, we have found that the decomposition rate varies dramatically depending upon the orientation of the crystalline axes relative to polarized x-ray beam and for differing diffracting conditions (spots) within the same crystalline orientation. We suggest that this effect is due to Compton scattering of the polarized x-rays with electron clouds that is dependent upon their relative orientation. This novel effect may yield valuable insight regarding anisotropic detonation sensitivity in energetic materials such as PETN.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quick and Dirty WFPC2 Stellar Photometry

The latest release of the IRAF (Image Reduction and Analysis Facility) MXTOOLS package includes the new tasks QDWFPC2 (Quick and Dirty Wide Field and Planetary Camera, which does quick CCD (charge-coupled device) stellar photometry on two Hubble Space Telescope (HST) WFPC2 (Wide Field and Planetary Camera) observations: WFPC2COLOR, which converts HST WFPC2 instrumental magnitudes to standard colors using the Holtzman et al. color equations, and QDCMD (Quick and Dirty Color Magnitude Diagram), which reads the output of WFPC2COLOR and displays a color-magnitude diagram on a user-chosen graphics device.

Mighell, Kenneth J.↗

Assembly of the Dark Energy Survey CCD Imager

The Dark Energy Camera (DECam) is the new wide field prime-focus imager for the Blanco 4m telescope at CTIO.This instrument is a 2.2 sq. deg. camera with a 45 cm diameter focal plane consisting of 62 2k × 4k CCDs and 12 2k × 2kCCDs and was developed for the Dark Energy Survey that will start operations at CTIO in 2011. DECam includes thevessel shell, the optical window cell, the CCDs with their readout electronics and vacuum interface, the focal planesupport plate and its mounts, and the cooling system and thermal controls. Assembly of the imager, alignment of thefocal plane and installation of the CCDs are described. During DECam development a full scale prototype was used formulti-CCD readout tests. This test vessel went through several stages as the CCDs and related hardware progressedfrom early prototypes to final production designs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Event-Driven Random-Access-Windowing CCD Imaging System

A charge-coupled-device (CCD) based high-speed imaging system, called a realtime, event-driven (RARE) camera, is undergoing development. This camera is capable of readout from multiple subwindows [also known as regions of interest (ROIs)] within the CCD field of view. Both the sizes and the locations of the ROIs can be controlled in real time and can be changed at the camera frame rate. The predecessor of this camera was described in High-Frame-Rate CCD Camera Having Subwindow Capability (NPO- 30564) NASA Tech Briefs, Vol. 26, No. 12 (December 2002), page 26. The architecture of the prior camera requires tight coupling between camera control logic and an external host computer that provides commands for camera operation and processes pixels from the camera. This tight coupling limits the attainable frame rate and functionality of the camera. The design of the present camera loosens this coupling to increase the achievable frame rate and functionality. From a host computer perspective, the readout operation in the prior camera was defined on a per-line basis; in this camera, it is defined on a per-ROI basis. In addition, the camera includes internal timing circuitry. This combination of features enables real-time, event-driven operation for adaptive control of the camera. Hence, this camera is well suited for applications requiring autonomous control of multiple ROIs to track multiple targets moving throughout the CCD field of view. Additionally, by eliminating the need for control intervention by the host computer during the pixel readout, the present design reduces ROI-readout times to attain higher frame rates. This camera (see figure) includes an imager card consisting of a commercial CCD imager and two signal-processor chips. The imager card converts transistor/ transistor-logic (TTL)-level signals from a field programmable gate array (FPGA) controller card. These signals are transmitted to the imager card via a low-voltage differential signaling (LVDS) cable assembly. The FPGA controller card is connected to the host computer via a standard peripheral component interface (PCI).

Monacos, Steve↗

Using APART for wall visibility calculations in the calibration channel of wide field planetary camera II

The cone visibility from the CCD detector array plane in the calibration channel of wide field planetary camera II (WFPC II) is analyzed, using APART, for three representative wavelengths as characterized by indices of refraction. The light pipe walls are visible from the corners of the equivalent CCD detector array when imaging with the smallest index of refraction, n = 1.375. Painting the inside of the light pipe walls will result in a decrease in their visibility.

Scholl, James W.↗

Optimised Post-Exposure Image Sharpening Code for L3-CCD Detectors

As light from celestial bodies traverses Earth's atmosphere, the wavefronts are distorted by atmospheric turbulence, thereby lowering the angular resolution of ground-based imaging. Rapid time-series imaging enables Post-Exposure Image Sharpening (PEIS) techniques, which employ shift-and-add frame registration to remove the tip-tilt component of the wavefront error--as well as telescope wobble, thus benefiting all observations. Further resolution gains are possible by selecting only frames with the best instantaneous seeing--a technique sometimes calling 'Lucky Imaging'. We implemented these techniques in the 1990s, with the TRIFFID imaging photon-counting camera, and its associated data reduction software. The software was originally written for time-tagged photon-list data formats, recorded by detectors such as the MAMA. This paper describes our deep re-structuring of the software to handle the 2-d FITS images produced by Low Light Level CCD (L3-CCD) cameras, which have sufficient time-series resolution (>30 Hz) for PEIS. As before, our code can perform straight frame co-addition, use composite reference stars, perform PEIS under several different algorithms to determine the tip/tilt shifts, store 'quality' and shift information for each frame, perform frame selection, and generate exposure-maps for photometric correction. In addition, new code modules apply all 'static' calibrations (bias subtraction, dark subtraction and flat-fielding) to the frames immediately prior to the other algorithms. A unique feature of our PEIS/Lucky Imaging code is the use of bidirectional wiener-filtering. Coupled with the far higher sensitivity of the L3-CCD over the previous TRIFFID detectors, much fainter reference stars and much narrower time windows can be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Droplet Combustion Experiment

Liquid fuel combustion provides a major portion of the world's energy supply. In most practical combustion devices, liquid burns after being separated into a droplet spray. Essential to the design of efficient combustion systems is a knowledge of droplet combustion behavior. The microgravity environment aboard spacecraft provides an opportunity to investigate the complex interactions between the physical and chemical combustion processes involved in droplet combustion without the complications of natural buoyancy. Launched on STS-83 and STS-94 (April 4 and July 1, 1997), the Droplet Combustion Experiment (DCE) investigated the fundamentals of droplet combustion under a range of pressures (0.25 to 1 atm), oxygen mole fractions (<0.5), and droplet sizes (1.5 to 5 mm). Principal DCE flight hardware features were a chamber to supply selected test environments, the use of crew-inserted bottles, and a vent system to remove unwanted gaseous combustion products. The internal apparatus contained the droplet deployment and ignition mechanisms to burn single, freely deployed droplets in microgravity. Diagnostics systems included a 35-mm high-speed motion picture camera (see the following sequence of photos) with a backlight to photograph burning droplets and a camcorder to monitor experiment operations. Additional diagnostics included an ultraviolet-light-sensitive CCD (charge couple discharge) camera to obtain flame radiation from hydroxyl radicals (see the final figure) and a 35-mm SLR (single-lens-reflex) camera to obtain color still photographs of the flames.

Nayagam, Vedha↗

OH Planar Laser Induced Fluorescence (PLIF) Measurements for the Study of High Pressure Flames: An Evaluation of a New Laser and a New Camera System

Planar laser induced fluorescence (PLIF) is used by the Combustion Branch at the NASA Glenn Research Center (NASA Glenn) to assess the characteristics of the flowfield produced by aircraft fuel injectors. To improve and expand the capabilities of the PLIF system new equipment was installed. The new capabilities of the modified PLIF system are assessed by collecting OH PLIF in a methane/air flame produced by a flat flame burner. Specifically, the modifications characterized are the addition of an injection seeder to a Nd:YAG laser pumping an optical parametric oscillator (OPO) and the use of a new camera with an interline CCD. OH fluorescence results using the injection seeded OPO laser are compared to results using a Nd:YAG pumped dye laser with ultraviolet extender (UVX). Best settings of the new camera for maximum detection of PLIF signal are reported for the controller gain and microchannel plate (MCP) bracket pulsing. Results are also reported from tests of the Dual Image Feature (DIF) mode of the new camera which allows image pairs to be acquired in rapid succession. This allows acquisition of a PLIF image and a background signal almost simultaneously. Saturation effects in the new camera were also investigated and are reported.

Tedder, Sarah↗

Cryogenic Refractive Indices of S-LAH55, S-LAH55V, S-LAH59, S-LAM3, S-NBM51, S-NPH2, S-PHM52, and S-TIH14 Glasses

The Transiting Exoplanet Survey Satellite (TESS) is an explorer-class planet finder, whose principal goal is to detect small planets with bright host starts in the solar neighborhood. The TESS payload consists of four identical cameras and a Data Handling Unit (DHU) fitted with CCD detectors and associated electronics. Each camera consist of a lens assembly with seven optical elements that include various types of Ohara glass substrates. The successful implementation of a panchromatic and a thermal lens assembly design for these cameras requires a fairly accurate (up to 0.000001 (1e-6)) knowledge of the temperature- and wavelength-dependent of the refractive index in the wavelength and temperature range of operation. Hence, this paper is devoted to report on measurements of the refractive index over the wavelength range of 0.42-1.15 micrometers and temperature range of 110-300 K for the following Ohara glasses: S-LAH55, S-LAH55V, S-LAH59, S-LAM3, S-NBM51, S-NPH2, S-PHM52, and S-TIH14. The measurements were performed utilizing the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at NASA's Goddard Space Flight Center. A dense coverage of the absolute refractive index for all these substrates in the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dndT) and dispersion relation (dnd) as a function of wavelength and temperature. A comparison of the measured indices with literature values, specifically the temperature-dependent refractive indices of S-PHM52 and S-TIH14 reported by Yamamuro et al. [Yamamuro et al., Opt. Eng. 45(8), 083401 (2006)], will be presented.

cryogenic temperatures↗

Performance of a hardened x-ray streak camera at Lawrence Livermore National Laboratory’s National Ignition Facility

Electron tubes continue to provide the highest speeds possible for recording dynamics of hot high-energy density plasmas. Standard streak camera drive electronics and CCD readout are not compatible with the radiation environment associated with high DT fusion yield inertial confinement fusion experiments >10 13 14 MeV DT neutrons or >10 9 n cm -2 ns -1 . Here, we describe a hardened x-ray streak camera developed for the National Ignition Facility and present preliminary results from the first experiment on which it has participated, recording the time-resolved bremsstrahlung spectrum from the core of an inertial confinement fusion implosion at more than 40× the operational neutron yield limit of the previous National Ignition Facility x-ray streak cameras.

47 OTHER INSTRUMENTATION↗

Scientific CCD technology at JPL

Charge-coupled devices (CCD's) were recognized for their potential as an imaging technology almost immediately following their conception in 1970. Twenty years later, they are firmly established as the technology of choice for visible imaging. While consumer applications of CCD's, especially the emerging home video camera market, dominated manufacturing activity, the scientific market for CCD imagers has become significant. Activity of the Jet Propulsion Laboratory and its industrial partners in the area of CCD imagers for space scientific instruments is described. Requirements for scientific imagers are significantly different from those needed for home video cameras, and are described. An imager for an instrument on the CRAF/Cassini mission is described in detail to highlight achieved levels of performance.

Janesick, J.↗

Design and development of the 3.2 gigapixel camera for the Large Synoptic Survey Telescope

The Large Synoptic Survey Telescope (LSST) is a large aperture, wide-field facility designed to reflect deep images of half the sky every few nights. There is only a single instrument on the telescope, a 9.6 square degree visible-band camera, which is mounted close to the secondary mirror, and points down toward the tertiary. The requirements of the LSST camera present signifcant technical design challenges. To cover the entire 0.35 to 1 μm visible band, the camera incorporates an array of 189 over-depleted bulk silicon CCDs with 10 μm pixels. The CCDs are assembled into 3 x 3 "rafts", which are then mounted to a silicon carbide grid to achieve a total focal plane flatness of 15 μm p-v. The CCDs have 16 amplifiers per chip, enabling the entire 3.2 Gigapixel image to be read out in 2 seconds. Unlike other astronomical cameras, a vast majority of the focal plane electronics are housed in the cryostat, which uses a mixed refrigerant Joule-Thompson system to maintain a -100ºC sensor temperature. The shutter mechanism uses a 3 blade stack design and a hall-effect sensor to achieve high resolution and uniformity. There are 5 filters stored in a carousel around the cryostat and the auto changer requires a dual guide system to control its position due to severe space constraints. This paper presents an overview of the current state of the camera design and development plan.

99 GENERAL AND MISCELLANEOUS↗