Search NASA⌕ Search

SEARCH · Search NASA

Results for “CFD simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Machine Learning Based Prediction of Airflow Maldistribution in A-Type Heat Exchangers

Airflow maldistribution is one of the primary causes of performance degradation in air-to refrigerant heat exchangers (HX) and has been shown to decrease heat transfer by as much as 35%. As a result, many units are oversized to meet the target capacity, resulting in increased system cost and refrigerant charge. Several studies have explored how characteristics like package type and HX geometry impact the flow profile, but results are restricted to a limited range of parameters and cannot be extrapolated to new designs. In this work, a machine learning (ML) model is trained to predict the inlet flow profile of dry air entering A-type HXs across a broad range of geometries and conditions. Flow profiles are generated using a porous media CFD model and used to train an Artificial Neural Network (ANN) which exhibits maximum and average relative L2 norm errors of 0.48 and 0.05. Additionally, these predictions take less than a second to generate resulting in a speed up factor of 2.42E5 compared to CFD. Component-level simulations are conducted to determine the performance degradation resulting from the predicted airflow maldistribution profiles. The new ML model will enable rapid and accurate prediction of performance degradation resulting from airflow maldistribution in A-type HXs, allowing for more accurate and cost-effective HX design.

42 ENGINEERING↗

Spark-Assisted HCCI Residential CHP

A transformative small spark ignition (SI) internal combustion (IC) engine fueled with natural gas was developed for combined heat and power (CHP) applications using a combination of cycle simulations, computational fluid dynamics (CFD) modeling, and engine experiments. The resulting 1 kW CHP engine was demonstrated to achieve 36.1% brake thermal efficiency (BTE) while meeting aggressive exhaust emissions targets using a low-cost three-way catalyst. Starting from a “clean-sheet” design, modeling tools were used to select the optimal engine parameters and operating characteristics. The disruptive technologies developed for the CHP system have a target lifetime of at least 10 years. The engine cost at volume of 10,000 units was estimated to be $\$$1,050. A combination of experimental and simulation results were used to identify a path to the program target of 38.6% BTE. Base engine design parameters (i.e., displacement, speed, bore, stroke, valve timings, and compression ratio) were optimized to reduce friction, heat transfer, and exhaust losses. The base clean sheet prototype engine achieved 32% BTE. Optimization of the lube oil and coolant temperatures added 1.8% BTE. The addition of exhaust gas recirculation added 1.1% BTE. Novel thermal barrier coatings (TBCs) developed over the course of the project added 1.2% BTE. Further improvements in engine friction reduction (1.3% BTE) and improved combustion (1.2% BTE) are estimated to meet the program target 38.6% BTE, while also meeting the stringent criteria pollutant emissions targets.

42 ENGINEERING↗

Design Tools to Assess Hydro-Turbine Biological Performance: Priest Rapids Dam Turbine Replacement Project

Over the past two decades, there have been many studies describing injury mechanisms associated with turbine passage, the response of various fish species to these mechanisms, and the probability of survival through dams. Although developing tools to design turbines that improve passage survival has been difficult and slow, a more robust quantification of the turbine environment has emerged through integrating physical model data, fish survival data, and computational fluid dynamics (CFD) studies. Grant County Public Utility District (GCPUD) operates the Priest Rapids Dam (PRD), a hydroelectric facility on the Columbia River in Washington State. The dam contains 10 Kaplan-type turbine units that are now almost 50 years old. The Utility District plans to refit all of these aging turbines with new turbines. The Columbia River at PRD is a migratory pathway for several species of juvenile and adult salmonids, so passage of fish through the dam is a major consideration when replacing the turbines. In this presentation, a method for turbine biological performance assessment (BioPA) is introduced. Using this method, a suite of biological performance indicators is computed based on simulated data from a CFD model of a proposed turbine design. Each performance indicator is a measure of the probability of exposure to a certain dose of an injury mechanism. Using known relationships between the dose of an injury mechanism and frequency of injury (dose–response) from laboratory or field studies, the likelihood of fish injury for a turbine design can be computed from the performance indicator. By comparing the values of the indicators from proposed designs, the engineer can identify the more-promising alternatives. We will present application of the BioPA method for baseline risk assessment calculations for the existing Kaplan turbines at PRD that will be used as the minimum biological performance that a proposed new design must achieve.

CFD↗

Performance of Virtual Current Meters in Hydroelectric Turbine Intakes

Standards provide recommendations for the best practices in the installation of current meters for measuring fluid flow in closed conduits. These include PTC-18 and IEC-41 . Both of these standards refer to the requirements of the ISO Standard 3354 for cases where the velocity distribution is assumed to be regular and the flow steady. Due to the nature of the short converging intakes of Kaplan hydroturbines, these assumptions may be invalid if current meters are intended to be used to characterize turbine flows. In this study, we examine a combination of measurement guidelines from both ISO standards by means of virtual current meters (VCM) set up over a simulated hydroturbine flow field. To this purpose, a computational fluid dynamics (CFD) model was developed to model the velocity field of a short converging intake of the Ice Harbor Dam on the Snake River, in the State of Washington. The detailed geometry and resulting wake of the submersible traveling screen (STS) at the first gate slot was of particular interest in the development of the CFD model using a detached eddy simulation (DES) turbulence solution. An array of virtual point velocity measurements were extracted from the resulting velocity field to simulate VCM at two virtual measurement (VM) locations at different distances downstream of the STS. The discharge through each bay was calculated from the VM using the graphical integration solution to the velocity-area method. This method of representing practical velocimetry techniques in a numerical flow field has been successfully used in a range of marine and conventional hydropower applications. A sensitivity analysis was performed to observe the effect of the VCM array resolution on the discharge error. The downstream VM section required 11–33% less VCM in the array than the upstream VM location to achieve a given discharge error. In general, more instruments were required to quantify the discharge at high levels of accuracy when the STS was introduced because of the increased spatial variability of the flow velocity.

13 HYDRO ENERGY↗

Uncertainty quantification tools for multiphase gas-solid flow simulations using MFIX

Computational fluid dynamics (CFD) has been widely studied and used in the scientific community and in the industry. Various models were proposed to solve problems in different areas. However, all models deviate from reality. Uncertainty quantification (UQ) process evaluates the overall uncertainties associated with the prediction of quantities of interest. In particular it studies the propagation of input uncertainties to the outputs of the models so that confidence intervals can be provided for the simulation results. In the present work, a non-intrusive quadrature-based uncertainty quantification (QBUQ) approach is proposed. The probability distribution function (PDF) of the system response can be then reconstructed using extended quadrature method of moments (EQMOM) and extended conditional quadrature method of moments (ECQMOM). The report first explains the theory of QBUQ approach, including methods to generate samples for problems with single or multiple uncertain input parameters, low order statistics, and required number of samples. Then methods for univariate PDF reconstruction (EQMOM) and multivariate PDF reconstruction (ECQMOM) are explained. The implementation of QBUQ approach into the open-source CFD code MFIX is discussed next. At last, QBUQ approach is demonstrated in several applications. The method is first applied to two examples: a developing flow in a channel with uncertain viscosity, and an oblique shock problem with uncertain upstream Mach number. The error in the prediction of the moment response is studied as a function of the number of samples, and the accuracy of the moments required to reconstruct the PDF of the system response is discussed. The QBUQ approach is then demonstrated by considering a bubbling fluidized bed as example application. The mean particle size is assumed to be the uncertain input parameter. The system is simulated with a standard two-fluid model with kinetic theory closures for the particulate phase implemented into MFIX. The effect of uncertainty on the disperse-phase volume fraction, on the phase velocities and on the pressure drop inside the fluidized bed are examined, and the reconstructed PDFs are provided for the three quantities studied. Then the approach is applied to a bubbling fluidized bed with two uncertain parameters, particle-particle and particle-wall restitution coefficients. Contour plots of the mean and standard deviation of solid volume fraction, solid phase velocities and gas pressure are provided. The PDFs of the response are reconstructed using EQMOM with appropriate kernel density functions. The simulation results are compared to experimental data provided by the 2013 NETL small-scale challenge problem. Lastly, the proposed procedure is demonstrated by considering a riser of a circulating fluidized bed as an example application. The mean particle size is considered to be the uncertain input parameter. Contour plots of the mean and standard deviation of solid volume fraction, solid phase velocities, and granular temperature are provided. Mean values and confidence intervals of the quantities of interest are compared to the experiment results. The univariate and bivariate PDF reconstructions of the system response are performed using EQMOM and ECQMOM.

97 MATHEMATICS AND COMPUTING↗

Modeling Flow and Particle Deposition in a Spent Nuclear Fuel Assembly

CFD (Computational Fluid Dynamic) simulation of aerosol-laden natural convective flow and particle deposition in a spent fuel storage canister with 37 assemblies is currently computationally prohibitive. PWR (Pressurized Water Reactor) assemblies have up to 289 pins or tubes with several spacer grids to align the pins. Spacer grids with mixing vanes induce swirling during operation to increase heat transfer. Each spacer grid contains hundreds of small structures such as retaining clips, channel walls, and openings. The largest canisters store 37 PWR assemblies thus, there are numerous pins, tubes, and spacer grids for which the flow region between and around these structures needs to be determined along with the movement and deposition of aerosol particles. Because of the complicated geometry, modeling the intricate flow even for just one assembly is currently impractical. Nonetheless, we are developing techniques for a practical model to assess the natural aerosol particle deposition process in a canister in the event that a release occurs from one or more fuel pins. In the previous work it was demonstrated that CFD can model the flow through a PWR spacer grid with mixing vanes, including particle deposition, in a reasonable amount of time on a personal computer. In this work, the analysis is extended to include the bypass region between an assembly and the canister basket walls. It is shown that the flow velocity in the bypass region is about three times that of the interstitial region between the pins. The lengths before and after the spacer grid are also extended to determine when the flow becomes fully developed. In addition, the approach of computationally “stitching together” segments of an assembly is demonstrated with the plan to ultimately model a full assembly. The fraction of particles that are deposited in a segment with a spacer grid is determined as a function of particle size and flow velocity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Implementation of a High-Fidelity Interface Resolving Method in Nek5000

The development and utilization of computational fluid dynamics (CFD) models for large, high-temperature electric melters in the Waste Treatment and Immobilization Plant (WTP) in eastern Washington State have proven to be valuable for various purposes. These models allow for a better understanding of the physio-chemical processes occurring within the melter vessels and can contribute to improving operational efficiency, throughput, and addressing operational issues related to vitrification. The CFD models employed for these melter vessels incorporate multiphase fluid flow and heat transfer simulations in different regions, including the plenum, cold cap, and molten glass regions. As the tank waste and glass formers are introduced into the melter, a reacting batch layer known as the cold cap forms on top of the molten glass. To enhance the melt rate, forced convection bubblers located at the bottom of the melters generate convection currents that help homogenize the molten glass and provide heat to the cold cap. As the bubbles rise through the highly viscous glass, they adopt a spherical-cap shape [1]. Meanwhile, the conversion of the batch to glass generates significant amounts of gases (such as water vapor, carbon dioxide, sulfur dioxide, and NOx) due to thermal decomposition [2]. These gases become trapped between the cold cap and molten glass, forming a foam layer [3]. For modeling multiphase flow in CFD and heat transfer simulations of waste glass melters at different scales, efforts are underway to augment the capabilities of the Nek5000 [4] and NekRS [5] open-source codes [6]. Nek5000/NekRS is a scalable and efficient spectral element code that has been successfully applied to a wide range of fluid dynamics problems. By leveraging the Nek5000/NekRS software, it becomes possible to model the melter systems more affordably and with lower computational requirements compared to currently utilized commercial CFD software. The specific objectives of this ongoing effort include: 1. Implementation of a level set method in Nek5000/NekRS: The level set method is a numerical technique commonly employed in CFD simulations to track and represent the interface between different phases or materials accurately. By incorporating this method into Nek5000/NekRS, the ability to simulate multiphase flows in waste glass melters at a high level of fidelity can be achieved. 2. Demonstration of capability for air bubbling through molten glass: As part of the development process, a specific case of air bubbling through molten glass will be simulated using the augmented Nek5000/NekRS code. This demonstration aims to showcase the ability of the software to accurately capture and analyze the complex phenomena involved in the multiphase flow within waste glass melters. By achieving these objectives, the improved Nek5000/NekRS code will offer a powerful computational tool for simulating and analyzing waste glass melter systems, enabling better understanding, optimization, and troubleshooting of these vitrification processes. The ability to accurately model and simulate multiphase flows has broad relevance across many industries and scientific domains, and the improved functionality can contribute to advancements in various fields beyond waste glass melter simulations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical Study of Vortex Core in Turbulent Swirling Flow

Swirling flow has attracted a great deal of research interest. An application of swirling flow can be found in many engineering areas; such as gas cyclone and heat transfer enhancement. In nuclear engineering, swirling flow is used as heat transfer enhancement in rod bundle by installing grid spacer and mixing vane. Because of its extensive applications, there has been a great number of experimental and numerical investigations of swirling flow. McClusky et al., experimentally studied mapping of the lateral velocity in rod bundle using Laser Doppler Velocimetry (LDV) and Conner et al. predicted the flow field in rod bundle by CFD. To understand the characteristics of swirling flow such as tangential velocity and vortex core swirling flow, some researchers investigated swirling flow in a pipe instead of in rod bundle. This is due to the similarity between swirling flow in a pipe and rod bundle. In recent study, flow mapping of 2D velocity field of single-phase swirling flow had been conducted experimentally by Particle Image Velocimetry (PIV). However, this method needs calibration and complicated. The new measurement technique for flow mapping in swirling flow was done by phased array Ultrasonic Velocity Profiler (PAUVP). Hamdani et al., successfully plotted velocity field and determined the swirling core region (vortex core). This technique is nonintrusive and no need calibration. However, there was a limitation of the measurement because phased array UVP cannot capture 360 deg. velocity field inside the pipe. In addition, tangential velocity in CFD results was not agree well with experiment data due asymmetric problem. To evaluate this limitation of experimental method, the numerical simulations using Computational Fluid Dynamics (CFD) needs to be performed. The objective of this study is to use the commercial CFD code Fluent to model the developing turbulent swirling flow induced by twisted tape inside a straight pipe, and to gain an understanding of such a flow and the turbulence models involved in the simulation. Straight pipe is used instead of rod bundle for a simplification. In this work, the Renormalized Group (RNG) k-{epsilon} turbulence model and Reynolds Stress Model (RSM) turbulence model, are performed to study the phenomena of vortex core in a pipe with twisted tape inserts. Effects of the Reynolds number and asymmetric of twisted tape (inclination, {alpha} = 5 deg. and {alpha} = 20 deg.) on swirling core position are examined using water as the testing fluid. Furthermore, the Navier-Stokes equations will be solved to obtain results that can be validated with the previous experimental results. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MODELING AND SIMULATIONS OF DETERIORATED TURBULENT HEAT TRANSFER IN WALL HEATED CYLINDRICAL TUBE

The paper discusses the modeling and simulations of Deteriorated Turbulent Heat Transfer (DTHT) for a wall-heated fluid flows, which can be observed in gas-cooled nuclear power reactors during Pressurized Conduction Cooldown (PCC) event due to loss of force circulation flow. The DTHT regime is defined as the deterioration of normal turbulent heat transport due to increase of acceleration and buoyancy forces. The Computational Fluid Dynamics (CFD) tools such as Nek5000 and STAR-CCM+ can help to analyze the DTHT phenomena in reactors for efficient thermal-fluid designs. 3D CFD non-isothermal modeling and simulations were performed in a wall-heated circular tube. The simulation results were verified with two different CFD tools, Nek5000 and STAR-CCM+, and validated with an experimental data. The predicted bulk temperatures were identical in both CFD tools, as expected. Good agreement between simulated results and measured data were obtained for wall temperatures along the tube axis using Nek5000. In STAR-CCM+, the under-predicted wall temperatures were mainly due to higher turbulence in the wall region. In STAR-CCM+, the predicted DTHT was over 48% at outlet when compared to inlet heat transfer values.

deteriorated turbulent heat transfer↗

Free-Surface Liquid Lithium Flow Modeling and Stability Analysis for Fusion Applications

Liquid metal plasma facing components are considered an attractive design choice for fusion devices including pilot plants. Virtual prototyping of such devices includes modeling of free-surface flow of the electrically conductive liquid, which requires computational fluid dynamics (CFD) and magnetohydrodynamics (MHD) simulations. Numerical tools capable of simulating flows and heat transfer in the free-surface MHD flow were developed at PPPL based on the customized ANSYS CFX. Here, MHD is introduced using a magnetic vector potential approach. Free-surface flow capabilities are available in the code and were tested. Special stabilization procedures were derived and applied to improve convergence of the momentum equations with the source terms due to the Lorentz force and surface tension. Important characteristics of the fusion-relevant liquid metal flow is free surface smoothness and stability. Heat flux from the plasma impacts the liquid surface at a very acute angle, so any change of the free surface from axisymmetry can dramatically increase the local heat flux density and thus create excessive evaporation of liquid lithium into the plasma, which is detrimental to operations. Stability analysis of the liquid metal film flow was performed to determine applicable flow regimes. Thin film flow along horizontal wall is considered. Effects of gravity, magnetic field, and surface tension are included in the analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the Modeling of Thermal Radiation at the Top Surface of a Vacuum Arc Remelting Ingot

Two models have been implemented for calculating the thermal radiation emitted at the ingot top in the VAR process, namely, a crude model that considers only radiative heat transfer between the free surface and electrode tip and a more detailed model that describes all radiative exchanges between the ingot, electrode, and crucible wall using a radiosity method. From the results of the second model, it is found that the radiative heat flux at the ingot top may depend heavily on the arc gap length and the electrode radius, but remains almost unaffected by variations of the electrode height. Both radiation models have been integrated into a CFD numerical code that simulates the growth and solidification of a VAR ingot. The simulation of a Ti-6-4 alloy melt shows that use of the detailed radiation model leads to some significant modification of the simulation results compared with the simple model. This is especially true during the hot-topping phase, where the top radiation plays an increasingly important role compared with the arc energy input. Thus, while the crude model has the advantage of its simplicity, use of the detailed model should be preferred.

36 MATERIALS SCIENCE↗

Assessing the use of portable air cleaners for reducing exposure to airborne diseases in a conference room with thermal stratification

The COVID-19 pandemic has highlighted the need for strategies that mitigate the risk of aerosol disease transmission in indoor environments with different ventilation strategies. It is necessary for building operators to be able to estimate and compare the relative impacts of different mitigation strategies to determine suitable strategies for a particular situation. Using a validated CFD model, this study simulates the dispersion of exhaled contaminants in a thermally stratified conference room with overhead heating. The impacts of portable air-cleaners (PACs) on the room airflow and contaminant distribution were evaluated for different PAC locations and flow rates, as well as for different room setups (socially distanced or fully occupied). To obtain a holistic view of a strategy's impacts under different release scenarios, we simultaneously model the steady-state distribution of aerosolized virus contaminants from eight distinct sources in 18 cases for a total of 144 release scenarios. The simulations show that the location of the source, the PAC settings, and the room set-up can impact the average exposure and PAC effectiveness. For this studied case, the PACs reduced the room average exposure by 31%-66% relative to the baseline case. Some occupant locations were shown to have a higher-than-average exposure, particularly those seated near the airflow outlet, and occupants closest to sources tended to see the highest exposure from said source. We found that these PACs were effective at reducing the stratification caused by overhead heating, and also identified at least one sub-optimal location for placing a PAC in this space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A multi-dimensional dataset for two-phase instability in low pressure natural circulation based on direct transient local measurement

Thermal hydraulic instability can challenge the control and the safety of nuclear reactors. This experimental research captures and investigates the instability in a low-pressure (1–10 atmospheres) natural circulation loop with an adiabatic chimney installed above the heated section. Direct transient local measurement of two-phase flow is performed at multiple axial locations along the flow channel with thermocouples and conductivity probes traversed by customized high-precision mechanisms. Based on the periodicity of oscillations, a post-processing method is proposed to align the data captured non-simultaneously to reconstruct the instability behavior in one representative period. The averaging operation over multiple oscillation cycles is performed to reduce the random errors. Cyclic phenomena are clearly demonstrated by the post-processed data, and rapid void fraction change induced by the flashing is observed to be significant in the driving mechanism for low pressure oscillations. Parametric effects of inlet subcooling, heat flux, inlet flow restriction and system pressure are studied within the experiment range, and qualitative results are explained and compared with existing literature. The ratio between the oscillation period and the travelling time of the fluid particle through the test section is compared with the theoretical value for the density wave oscillation. The new dataset contains directly measured transient multi-dimensional two-phase data along the flow channel for natural circulation under density wave oscillations. The generated dataset is valuable for the validation of system analysis codes and CFD codes in the simulation of natural circulation phenomena and dynamic two-phase flow.

42 ENGINEERING↗

OpenACC acceleration for the P N – P N - 2 algorithm in Nek5000

Due to its high performance and throughput capabilities, GPU-accelerated computing is becoming a popular technology in scientific computing, in particular using programming models such as CUDA and OpenACC. The main advantage with OpenACC is that it enables to simply port codes in their ‘‘original’’ form to GPU systems through compiler directives, thus allowing an incremental approach. An OpenACC implementation is applied to the CFD code Nek5000 for simulation of incompressible flows, based on the spectral-element method. The work follows up previous implementations and focuses now on the P N - P N-2 method for the spatial discretization of the Navier–Stokes equations. Performance results of the ported code show a speed-up of up to 3.1 on multi-GPU for a polynomial order N > 11.

97 MATHEMATICS AND COMPUTING↗

Undesirable Flow Behavior in a Proposed Validation Data Set

The next generation nuclear plant (NGNP), whose development is supported by the U. S. Department of Energy, will be a very high temperature reactor (VHTR). The VHTR is a single-phase helium-cooled reactor that will provide helium at up to 1000 C. The prospect of a coolant at these temperatures circulating in the reactor vessel demands that careful analysis be performed to ensure that excessively hot spots are not created and that sufficient mixing of the coolant is obtained. Computational fluid dynamics (CFD) coupled with heat transfer will be used to perform the desired analyses. However, primarily because of the imperfect nature of modeling turbulent flow, any CFD calculations used to perform nuclear reactor safety analysis must be validated against experimental data. Experimental data have been taken in a scaled section of the lower plenum of a prismatic VHTR at the matched index of refraction (MIR) facility at the Idaho National Laboratory. These data were taken with the intent that they be examined for use as validation data. A series of investigations have been conducted to assess the MIR data. Issues that have already been examined include the extent of the required computational domain, the outlet boundary condition, the inlet data and the effect of the turbulence model. One of the jets that flow into the model impacts on a wedge, which represents a portion of a hexagonal graphite block that lines the inner wall of the lower plenum. The nature of the flow below this particular jet is such that a randomly varying recirculation zone is created. This recirculation zone is seen to change in size, causing a relatively long-time scale of motion or disturbance of the flow in the model. It is concluded that such a feature is undesirable in a validation data set, firstly because of its apparent random nature and, secondly, because to obtain an appropriate long-time average would be impractical because of the compute time required. It is predicted computationally that by eliminating the first of the four inlet jets into the scaled model, the resulting recirculation zone is rendered stable.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bypass Flow Computations using a One-Twelfth Symmetric Sector For Normal Operation in a 350 MWth VHTR

Significant uncertainty exists about the effects of bypass flow in a prismatic gas-cooled very high temperature reactor (VHTR). Bypass flow is the flow in the gaps between prismatic graphite blocks in the core. The gaps are present because of variations in their construction, imperfect installation and expansion and shrinkage from thermal heating and neutron fluence. Calculations are performed using computational fluid dynamics (CFD) for flow of the helium coolant in the gap and coolant channels along with conjugate heat generation and heat transfer in the fuel compacts and graphite. A commercial CFD code is used for all of the computations. A one-twelfth sector of a standard hexagonal block column is used for the CFD model because of its symmetry. Various scenarios are computed by varying the gap width from zero to 5 mm, varying the total heat generation rate to examine average and peak radial generation rates and variation of the graphite block geometry to account for the effects of shrinkage caused by irradiation. The calculations are for a 350 MWth prismatic reactor. It is shown that the effect of increasing gap width, while maintaining the same total mass flow rate, causes increased maximum fuel temperature while providing significant cooling to the near-gap region. The maximum outlet coolant temperature variation is increased by the presence of gap flow and also by an increase in total heat generation with a gap present. The effect of block shrinkage is actually to decrease maximum fuel temperature compared to a similar reference case.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Parametric study of natural circulation flow in molten salt fuel in molten salt reactor

The Molten Salt Reactor (MSR) is one of the most promising system proposed by Generation IV Forum (GIF) for future nuclear reactor systems. Advantages of the MSR are significantly larger compared to other reactor system, and is mainly achieved from its liquid nature of fuel and coolant. Further improvement to this system, which is a natural circulating molten fuel salt inside its tube in the reactor core is proposed, to achieve advantages of reducing and simplifying the MSR design proposed by GIF. Thermal hydraulic analysis on the proposed system was completed using a commercial computation fluid dynamics (CFD) software called FLUENT by ANSYS Inc. An understanding on theory behind this unique natural circulation flow inside the tube caused by fission heat generated in molten fuel salt and tube cooling was briefly introduced. Currently, no commercial CFD software could perfectly simulate natural circulation flow, hence, modeling this flow problem in FLUENT is introduced and analyzed to obtain best simulation results. Results obtained demonstrate the existence of periodical transient nature of flow problem, hence improvements in tube design is proposed based on the analysis on temperature and velocity profile. Results show that the proposed system could operate at up to 750MW core power, given that turbulence are enhanced throughout flow region, and precise molten fuel salt physical properties could be defined. At the request of the authors and the Proceedings Editor the name of the co-author Andrea Cioncolini was corrected from Andrea Coincolini. The same name correction was made in the Acknowledgement section on page 030004-10 and in reference number 4. The updated article was published on 11 May 2015.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Study on the Shock Wave Propagation Rule of a Gas Explosion in a Gas Compartment

Combined with the k-ε turbulence model of general application, a refined finite element model of a utility tunnel’s gas compartment filled with the methane/air mixture is developed. A series of analyses are made by using the powerful industry-leading computational fluid dynamics (CFD) software flame acceleration simulator (FLACS) to study the shock wave propagation rule in the gas compartment. The longitudinal and transversal distribution laws of the explosion shock wave are gained taking into consideration the spatial characteristics of the gas compartment. The influences of a few parameters, such as initial conditions and section size of the gas compartment, on the shock wave propagation rule are further discussed. The basic procedure for predicting the peak pressure of the blast wave is provided by considering the initial conditions and the gas compartment, and the corresponding injury effect of the explosion wave on the living beings is assessed. The investigation demonstrates that the peak pressure by the coupled effect between the initial conditions is significantly influenced, especially at the upper and lower gas explosion limits. The peak pressure increases gradually as the width or height increases, and both basically meet the linear relation. The proposed method can forecast the peak pressure of the explosion shock wave in the gas compartment accurately. According to the peak pressure longitudinal and transversal distributions of the blast wave, the peak pressure is far greater than the killing pressure threshold in the underground and closed space; consequently, it is not safe for the living beings in the gas compartment.

Lin, Shu-Chao↗