Search NASA⌕ Search

SEARCH · Search NASA

Results for “CMOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Design of a readout circuit incorporating a 12-bit analog-to-digital converter for cooled infrared focal plane array

The infrared focal plane array (IRFPA) is gradually becoming more systematic. In order to enhance the signal processing capabilities, analog-to-digital converters (ADC) integrated into the readout integrated circuit (ROIC) is an important development trend. However, the cryogenic effects of MOSFET devices will affect the conversion accuracy of the ADC at 77 K. In this paper, the main parameters of MOSFET are extracted at 77 K in 0.18 μm CMOS process, and a cryogenic model is established. Based on this, a digital ROIC is designed, which integrates a 12-bit single-slope integral ADC in pixel unit. By applying continuous integral ramp generator and mixed-voltage comparator, a high-linearity and low-power consumption single-slope ADC is realized for the cooled readout circuit. The measured dynamic effective number of bits of the ADC at 77 K is 10.92 bits, the static no-missing code resolution reaches 11.99 bits, the maximum differential nonlinear |DNL| < 1LSB and maximum integral nonlinear |INL| < 1LSB. This paper realizes the design of a digital ROIC for IRFPA and improves the simulation accuracy at 77 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Applications of Strain-Coupled Magnetoelectric Composites

This article deals with research, development and future directions of magnetoelectric composites for practical devices applications. In the past 20 years there has been a surge of research in the area of multiferroics (MF) and magnetoelectrics (ME) due to their potential to replace existing technologies based only on ferroelectric or ferromagnetic materials. Some of the magnetoelectric composites show exceptionally high potential in the area of magnetic field sensors, however, work remains before commercialization can be realized. The cross coupling among various ferroic parameters in magnetoelectric composites is several orders higher than single phase magetoelectrics, which make its favorable for low detection (nT or pT) magnetic field sensors. Advances in both layered structures or controlled three-dimensional matrix composites for applications as magnetoelectric nonvolatile memory elements are both required. Robust cross-coupling among various parameters with more than four logic states and its compatibility with complementary-symmetry metal–oxide–semiconductor (CMOS) technology are the main requirements for heterostructure magnetoelectric thin films. The major hurdles in the area of magnetoelectric nonvolatile memory elements are poor interfacial properties and weak magnetoelectric coupling for high density fast read and write processes. Another potential area is strained coupled magneto-electric composites where magnetostriction mediated dimensional change in the magnetic layer effectively modulate the change in the dimension of piezoelectric layers via piezostriction, which leads to a strong ME coupling where their coupling magnitude is sufficient for magnetic field sensors. Energy harvesters based on magnetoelectric composites are also intriguing concepts to capture various types of waste energy, in the form mechanical vibration, pressure, wind energy, hydrothermal and waste temperature.

36 MATERIALS SCIENCE↗

Enhancing mobility and interface state engineering via UV-ozone treatment in BEOL-compatible ultrathin TiO 2 transistors

It has emerged as a potential candidate to improve the performance of monolithic-three-dimensional (M3D) integration of fused logic and memories through low-temperature in situ synthesis of high-performance metal–oxide–semiconductor (MOS) transistors. Here, we report the demonstration of the BEOL-compatible low thermal budget (350 °C) fabrication process of ultrathin-TiO2 transistors by the combination of RTA and UV-ozone treatment (RTA-UVOz). UV–ozone (UVOz) treatment of TiO2 anatase films significantly enhances stability, boosting ION current and field effect mobility (μ FE ) by two times of magnitude in TiO2 TFTs. UV ozone treatment helps to eliminate pre-existing oxygen vacancies and carbon contamination on TiO2 channels even at low temperature (100 °C), resulting in high-quality channel/dielectric interfaces with low interface states (D it ). During UVOz treatment, oxygen species (O x ) passivate the oxygen vacancies ($V$$^{2+}_{o}$), and hence low concentration of $V$$^{2+}_{o}$ would be left for ionization/de-ionization under PBS/NBS, leading to improved bias stress stability. Furthermore, the TiO 2 TFTs with thin ZrO 2 gate dielectric exhibited excellent performance including a lower subthreshold swing (SS) of 98 mV/dec with high drive I ON current ∼ 4.5 μA/μm, a high I ON /I OFF > 10 9 , and mobility μFE of 7 cm 2 /V-s under a battery powered voltage of 1 V. UV–ozone treatment enables high-performance, CMOS-compatible TiO 2 transistors with a low thermal budget, ideal for next-generation flexible, energy-efficient electronics.

BEOL↗

Multi-spatio-temporal scales PIV in a turbulent buoyant jet discharging in a linearly stratified environment

Time-resolved particle image velocimetry is implemented with a camera array and several laser sheets; this results in a multi-spatio-temporal scale system that is modular and flexible. The setup is optimized to capture global flow features, while locally resolving in space and time near the Kolmogorov scale. The apparatus relies extensively on machine vision CMOS cameras; they are inexpensive and stream to computer hard drive with virtually continuous time-resolved records (up to one hour for the current system). This leads to statistically converged data and also helps in minimizing down time between experimental runs. Details of the implementation and design of experiment are reported. The system instruments a vertical buoyant jet discharging in a linearly stratified environment. Refractive index matched aqueous solutions enable precise optical deployment. The density difference is 3% and the fluids have similar dynamic viscosity. The jet Reynolds number is 2.00 x 10 4 and is above the mixing transition. Such flows are typically challenging to instrument and few velocity field data are available to date. The velocity statistics are reported as well as first insights gained from the campaign.

42 ENGINEERING↗

Magnetic properties of superparamagnetic, nanocrystalline cobalt ferrite thin films deposited at low temperature

Bulk cobalt ferrite, being a hard ferrite, shows high magnetization, high resistivity and high coercivity. If thin films of cobalt ferrite can be deposited at a low enough temperature and if its coercivity can be reduced, cobalt ferrite will make a very good candidate for use as a magnetic core of an integrated inductor in RF-CMOS ICs. Though polycrystalline and epitaxial thin films of cobalt ferrite have been made by various techniques, there are no reports of thin films of superparamagnetic cobalt ferrite. In this work, nanocrystalline cobalt ferrite thin films, which are superparamagnetic as deposited, have been prepared in the solution medium at ~190 °C, using microwave irradiation. The as-prepared films have a saturation magnetization (M S ) of 401 emu/cc and coercivity (H C ) of 19 Oe at room temperature for a crystallite size of 2 nm. The cobalt ferrite powder obtained as a by-product during the same process has M S of 50 emu/g and H C of 5 Oe at room temperature, making it superparamagnetic. The as-prepared films were annealed in air at 300 °C for 5 min and 10 min. Annealing for 10 min results in an increase in crystallite size to 36 nm, M S increases from 401 emu/cc to 545 emu/cc, and H C increases from 19 Oe to 860 Oe. In conclusion, the change in magnetic properties can be directly associated with change in the crystallite size and degree of crystallographic inversion, as determined by neutron diffraction and deduced from X-ray photoelectron spectroscopy.

36 MATERIALS SCIENCE↗

Ultra-high speed burst-mode imager for multi-frame radiography

A 720 x 720 pixel hybrid-CMOS imager was fabricated by Rockwell Scientific (now Teledyne Imaging Sensors). Several cameras have been in operation for 5 years, in a variety of static and dynamic experiments, at the 800MeV proton radiography (pRAD) facility at the LANSCE accelerator. The cameras can operate with a per-pulse adjustable inter-frame time of 250ns to 2s, and with an exposure/integration-time as short as 150 ns. Given the 800 ms total readout time, the imager can be externally synchronized to 0.1-to-5Hz, 50-ns wide proton beam pulses, and record 1000-frame radiographic movies of 5-to-30 minute duration. The effectiveness and dependence of the global electronic shutter on the pixelated Si photo-sensor bias voltage is discussed. The spatial resolution dependence of the full imaging system on various monolithic and structured scintillators is presented. We also present features of a new-generation 10-frame, 1024 x 1024 pixel, 50-ns exposure, 12-bit dynamic range imager, which is now in the design phase.

47 OTHER INSTRUMENTATION↗

A 15GSa/s, 1.5GHz bandwidth waveform digitizing ASIC

The PSEC4 custom integrated circuit was designed for the recording of fast waveforms for use in large-area time-of-flight detector systems. The ASIC has been fabricated using the IBM-8RF 0.13 micron CMOS process. On each of 6 analog channels, PSEC4 employs a switched capacitor array (SCA) 256 samples deep, a ramp-compare ADC with 10.5 bits of DC dynamic range, and a serial data readout with the capability of region-of-interest windowing to reduce dead time. The sampling rate can be adjusted between 4 and 15 Gigasamples/second [GSa/s] on all channels and is servo-controlled on-chip with a low-jitter delay-locked loop (DLL). The input signals are passively coupled on-chip with a -3 dB analog bandwidth of 1.5 GHz. The power consumption in quiescent sampling mode is less than 50 mW/chip; at a sustained trigger and readout rate of 50 kHz the chip draws 100 mW. After fixed-pattern pedestal subtraction, the uncorrected integral non-linearity is 0.15% over an 750 mV dynamic range. With a linearity correction, a full 1 V signal voltage range is available.The sampling timebase has a fixed-pattern non-linearity with an RMS of 13%, which can be corrected for precision waveform feature extraction and timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Tynode: A new vacuum electron multiplier

By placing, in vacuum, a stack of transmission dynodes (tynodes) on top of a CMOS pixel chip, a single free electron detector could be made with outstanding performance in terms of spatial and time resolution. The essential object is the tynode: an ultra thin membrane, which emits, at the impact of an energetic electron on one side, a multiple of electrons at the other side. The electron yields of tynodes have been calculated by means of GEANT-4 Monte Carlo simulations, applying special low-energy extensions. The results are in line with another simulation based on a continuous charge-diffusion model. By means of Micro Electro Mechanical System (MEMS) technology, tynodes and test samples have been realized. The secondary electron yield of several samples has been measured in three different setups. Finally, several possibilities to improve the yield are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The impact of incorporating shell-corrections to energy loss in silicon

Modern silicon tracking detectors based on hybrid or fully integrated CMOS technology are continuing to push to thinner sensors. The ionization energy loss fluctuations in very thin silicon sensors significantly deviates from the Landau distribution. Therefore, we have developed a charge deposition setup that implements the Bichsel straggling function, which accounts for shell-effects. This enhanced simulation is important for comparing with testbeam or collision data with thin sensors as demonstrated by reproducing more realistically the degraded position resolution compared with naïve ionization models based on simple Landau-like fluctuation. Our implementation of the Bichsel model agrees well with the multipurpose photo absorption ionization (PAI) model in Geant4 and is significantly faster. The code is made publicly available as part of the Allpix software package in order to facilitate predictions for new detector designs and comparisons with testbeam data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from the CBC3 readout ASIC for CMS 2S-modules

The CBC3 is the latest version of the CMS Binary Chip for readout of the outer radial region of the upgraded CMS Tracker at the High Luminosity LHC. This 254-channel, 130 nm CMOS ASIC is designed to be bump-bonded to a substrate to which sensors will be wire-bonded. It will instrument double-layer 2S-modules, containing two overlaid silicon microstrip sensors, aligned with a parallel orientation. On-chip logic identifies Level-1 trigger primitives from high transverse-momentum tracks by selecting correlated clusters in the two sensors. The CBC3 was delivered in late 2016; wafer probing and performance tests have been carried out. Several prototype modules using the CBC3 have been produced and tested in the lab and in different beams. The results show that the CBC3 satisfies CMS requirements and only small corrections are needed for the final version of the chip for production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a TDC ASIC for the upgrade of the ATLAS Monitored Drift Tube detector

We present the prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for high-luminosity LHC operation. This ASIC is based on a previously submitted demonstrator ASIC designed for timing performance evaluation, and includes all features necessary for the various operation modes, as well as the migration to the TSMC 130 nm CMOS technology. Here, we present the TDC design with the emphasis on added features and performance optimization. Tests of the timing performance demonstrate that this ASIC meets the design specifications. The TDC has a bin size of about 780 ps, and a timing bin variations within ±40 ps for all 24 channels with leading and trailing edge digitization, while the power consumption has been limited to 250 mW, corresponding to a consumption of about 5.2 mW per edge measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-hard miniature optical engine with high bandwidth

Future silicon trackers will be operated in an intense radiation environment and require large volumes of data to be transmitted off detector. In addition, the optical modules must be of low mass in order to limit multiple scattering and nuclear interactions that would degrade the overall performance of the detector. Here, we present a miniature optical engine that satisfies these constraints. The optical engine consists of an ASIC driving a VCSEL (Vertical Cavity Surface Emitting Laser) array in an optical package. Two ASICs are designed to operate a 12-channel VCSEL array at 1.28 or 5.12 Gb/s per channel, which yields a total data rate of up to 60 Gb/s. The core transistors are fabricated in a 65 nm CMOS process which enhance the radiation-hardness. Each channel contains equalizer (CTLE) and clock-data recovery circuits (CDR) so that the ASIC can restore the highly distorted electrical signal after propagating through several meters of cables of small diameter. The equalizer, CDR, and VCSEL driver are configured via a digital I 2 C chip interface with triple redundant memory to mitigate single event upset (SEU) effects. The bias and modulation currents are controlled by a digital-to-analog converter (DAC). We present the design of the circuit together with the results of the simulations and preliminary measurements.

47 OTHER INSTRUMENTATION↗

A secure measurement unit for an inspection system used in nuclear arms-control verification

Verification of arms control treaties may require information barriers to protect sensitive data acquired during the verification process. These information barriers are commonly implemented in software, but must store and operate on data that are vulnerable to attack and tampering. Here, we present a new Secure Measurement Unit based on a modified pipeline SAR ADC architecture. The idea is to move the information barrier back into the digitization process so that prohibited data is never created. A prototype 65nm CMOS Secure Measurement Unit (SMU) was tested using U-235, U-238, Co-60, Cs-137 and Am-241 sources. Here, the prototype accurately digitized allowable signals while being immune to side-channel attacks on signals within preset forbidden regions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic electronics for noble liquid neutrino detectors

In this paper we present the general features of cryogenic (or “cold”) electronics for noble liquid time projection chambers, with design principles and details for neutrino physics, a brief history of the technology and details of recent research and development that is driving the design of the detectors under construction. Finally, some comments on future R&D envisioned and the impact of this work on other fields is described. “Cold” in the context of this work applies to CMOS devices operated at 77 K and above, at liquids temperatures of LAr (89 K), LKr (125 K) and LXe (165 K), with most of the tests performed in, or at LN 2 (77 K). Additionally, the paper is concentrated on the design of cold electronics for large liquid argon TPCs, those that have been successfully operated, MicroBooNE and ProtoDUNE, and those designed or under construction, such as SBND and DUNE first and second 10 kton modules. The high performance achieved with MicroBooNE and ProtoDUNE – a high signal-to-noise ratio combined with high stability of response – is mainly due to the integral approach to design and construction of sensing electrodes with cold readout electronics in a modular approach with the cryostat signal feed-throughs incorporating warm interface electronics into a Faraday cage with the cryostat. The integral concept is described in some detail in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of charge state distributions using a scintillation screen

Absolute cross sections measured using electromagnetic devices to separate and detect heavy recoiling ions need to be corrected for charge state fractions. Accurate prediction of charge state distributions using theoretical models is not always a possibility, especially in energy and mass regions where data is sparse. As such, it is often necessary to measure charge state fractions directly. In this paper we present a novel method of using a scintillation screen along with a CMOS camera to image the charge dispersed beam after a set of magnetic dipoles. A measurement of the charge state distribution for 88 Sr passing through a natural carbon foil is performed. Using a Bayesian model to extract statistically meaningful uncertainties from these images, we find agreement between the new method and a more traditional method using Faraday cups. Additional future work is need to better understand systematic uncertainties. Our technique offers a viable method to measure charge state distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-pixel AI for lossy data compression at source for X-ray detectors

Integrating neural networks for data compression directly in the Read-Out Integrated Circuits (ROICs), i.e. the pixelated front-end, would result in a significant reduction in off-chip data transfer, overcoming the I/O bottleneck. Our ROIC test chip (AI-In-Pixel-65) is designed in a 65 nm Low Power CMOS process for the readout of pixelated X-ray detectors. Each pixel consists of an analog front-end for signal processing and a 10b analog-to-digital converter operating at 100KSPS. Here, we compare two non-reconfigurable techniques, Principal Component Analysis (PCA) and an AutoEncoder (AE) as lossy data compression engines implemented within the pixelated area. The PCA algorithm achieves 50$×$ compression, adds one clock cycle latency, and results in a 21% increase in the pixel area. The AE achieves 70$×$ compression, adds 30 clock cycle latency, and results in a similar area increase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗