Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Targeting accuracy of single-isocenter intensity-modulated radiosurgery for multiple lesions

To investigate the targeting accuracy of intensity-modulated SRS (IMRS) plans designed to simultaneously treat multiple brain metastases with a single isocenter. A home-made acrylic phantom able to support a film (EBT3) in its coronal plane was used. The phantom was CT scanned and three coplanar small targets (a central and two peripheral) were outlined in the Eclipse system. Peripheral targets were 6 cm apart from the central one. A reference IMRS plan was designed to simultaneously treat the three targets, but only a single isocenter located at the center of the central target was used. After positioning the phantom on the linac using the room lasers, a CBCT scan was acquired and the reference plan were mapped on it, by placing the planned isocenter at the intersection of the landmarks used in the film showing the linac isocenter. The mapped plan was then recalculated and delivered. The film dose distribution was derived using a cloud computing application ( (www.radiochromic.com)) that uses a triple-channel dosimetry algorithm. Comparison of dose distributions using the gamma index (5%/1 mm) were performed over a 5 × 5 cm{sup 2} region centered over each target. 2D shifts required to get the best gamma passing rates on the peripheral target regions were compared with the reported ones for the central target. The experiment was repeated ten times in different sessions. Average 2D shifts required to achieve optimal gamma passing rates (99%, 97%, 99%) were 0.7 mm (SD: 0.3 mm), 0.8 mm (SD: 0.4 mm) and 0.8 mm (SD: 0.3 mm), for the central and the two peripheral targets, respectively. No statistical differences (p > 0.05) were found for targeting accuracy between the central and the two peripheral targets. The study revealed a targeting accuracy within 1 mm for off-isocenter targets within 6 cm of the linac isocenter, when a single-isocenter IMRS plan is designed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of deformed image-based dose calculations for adaptive radiotherapy of nasopharyngeal carcinoma

The ultimate goal of adaptive radiotherapy (ART) is to deliver truly customized radiation treatments. Currently, the quality of cone-beam computed tomography (CBCT) images is still inferior to that of conventional CT images in contour delineations and dose calculations for replanning purposes. This retrospective study aims to evaluate the dosimetric accuracy of using deformed conventional CT images for dose calculations, in the hope of inferring the feasibility of ART using planning CT (PCT) images that deformed to up-to-date CBCT images for patients with nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC who had undergone 1 replan in their radiotherapy treatments were selected. The pretreatment PCT images were deformed to match the mid-treatment PCT images by deformable image registration. The same volumetric modulated arc therapy plan was then calculated on the deformed PCT images. The resulting dose distributions and dose volume histograms of the tumors and organs at risk (OARs) were compared with the original plan. Five dose levels, D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%}, were recorded for 9 NPC targets. Four dose levels, D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean}, were recorded for 15 OARs. The greatest percentage difference in observed dose for D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%} of the targets were 1.71%, 1.55%, 0.64%, 0.97%, and 1.13%, respectively. The greatest percentage difference in observed dose for D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean} of the OARs were -26.51% (left optic nerve), -17.06% (left optic nerve), 56.70% (spinal cord), and 18.97% (spinal cord), respectively. In addition, 29 of 45 (64%) dosimetric end points of the targets showed statistically significant dose differences (p p < 0.05). Dose calculations using deformed PCT images could result in significant dose uncertainties in target volumes and OARs. Larger dose deviations were found in OARs in comparison with target volumes. The spinal cord and optic nerve showed the greatest percentage dose differences and the clinical significance has yet to be determined. Deformable registration error was believed to be the problem causing the dose deviations. Owing to unknown clinical significanceof dose deviation results obtained from this study, a conventional CT scan is still required for replanning in patients with NPC who are experiencing significant anatomical changes during the course of radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields

The Geant4 toolkit was used to develop a Monte Carlo (MC)-based engine for accurate dose calculations in small radiation field sizes. The Geant4 toolkit (version 10.1.p02) was used to simulate 6-MV photon beam of a Varian2100C linear accelerator that is being used for stereotactic radiosurgery (SRS) treatment with small radiation fields. Geometric models of 3 in-house designed radiosurgical divergent cones, with the diameters of their projections at the isocenter being 10, 20, and 30 mm, were simulated. The accuracy of the MC simulation technique was examined by reproducing several different simulated dosimetric parameters of the primary beams with the experimental data. The dose distributions are first checked for single beams for each cone, then standard multiple field (SMF) techniques are applied. A sample set of DICOM files from computed tomography (CT) scan imaging of a patient's head was converted to the Geant4 geometry format to implement MC-based engine for a clinical test. To validate the accuracy of the MC-based calculations for SMF arrangements, the isodose lines from MC simulation in water phantom were compared with the measured isodose lines using EBT3 Gafchromic film in Solid Water phantoms. Agreements between measured and simulated depth dose values and beam profiles for SRS cones were generally within 2%/2 mm. For output factors, the largest discrepancy was observed for 10 mm SRS cone, which was 1.7%. For SMF techniques, in SRS cones, the MC simulation and EBT3 Gafchromic film dosimetry were in acceptable agreement (5%/5 mm). Excellent agreement between the results of the MC-based and measured dose values for both single and SMF techniques in SRS cones indicates the ability of the Geant4 toolkit to be applied as the platform for treatment planning of advanced radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PHASE: Personalized Head-based Automatic Simulation for Electromagnetic properties in 7T MRI

Accurate and individualized human head models are becoming increasingly important for electromagnetic (EM) simulations. These simulations depend on precise anatomical representations to realistically model electric and magnetic field distributions, particularly when evaluating Specific Absorption Rate (SAR) within safety guidelines. State of the art simulations use the Virtual Population due to limited public resources and the impracticality of manually annotating patient data at scale. Here, this paper introduces Personalized Head-based Automatic Simulation for EM properties (PHASE), an automated open-source toolbox that generates high-resolution, patient-specific head models for EM simulations using paired T1-weighted (T1w) magnetic resonance imaging (MRI) and computed tomography (CT) scans with 14 tissue labels. To evaluate the performance of PHASE models, we conduct semi-automated segmentation and EM simulations on 15 real human patients, serving as the gold standard reference. The PHASE model achieved comparable global SAR and localized SAR averaged over 10 grams of tissue (SAR-10g), demonstrating its potential as a promising tool for generating large-scale human model datasets in the future. The code and models of PHASE toolbox have been made publicly available: https://github.com/hrlblab/PHASE.

Deep learning↗

Impact of Concurrent Solubilization and Fines Migration on Fracture Aperture Growth in Shales during Acidized Brine Injection

Acidic hydraulic fracturing fluid chemically and physically alters shale rock fabric during injection and shut-in, creating a “reaction-altered zone” along the fracture faces. To better characterize the variable thickness and composition of this reaction-altered zone under advective flow, we take a coupled experimental and modeling approach. A fluidic cell, with six fiducial markers, is first fabricated to keep the rock sample in place during the core floods and to allow image alignment of acquired images. Then, we conduct a series of reactive core floods in a clay-rich siliceous Wolfcamp shale sample with 10 wt % carbonate, using a synthetic fracturing fluid under no confining stress and at room temperature. High-resolution computed tomography (CT) scans are periodically conducted to observe the spatial alteration of the fracture network. We then perform scanning electron microscopy (SEM-EDS) on the two orthogonal surfaces (fracture surface and freshly cut profile face) to generate high-resolution elemental maps that show the change in mineralogy, both with distance along a given flow path along a fracture surface and with depth from the fracture surface into the shale matrix. These results are contrasted against a two-dimensional (2D) advection-diffusion reaction model developed previously for batch reactions between shale and synthetic fracturing fluids. The model simulates the geochemical interaction occurring at the fracture/matrix interface and penetrating into the shale matrix during the reactive core flood. Both model and experimental results show that the acidic brine is neutralized during the core flood, corresponding to an increase in fracture aperture as a function of fluid volume injected with the greatest change near the inlet. SEM-EDS scans reveal significant dissolution of carbonates on the fracture surface without pyrite oxidation. The reactive transport model indicates that carbonate depletion into the shale interior should be observable, yet SEM-EDS shows no discernible loss of carbonate in the orthogonal profile face. The combination of these observations suggests an additional fracture evolution mechanism in the reactive system, i.e., fines migration. We show that fines migration enhances the access of fracturing fluid to the matrix resulting in a more pronounced fracture widening. Finally, we conclude that coupled mineral dissolution and fines migration govern fracture aperture growth during acidized brine injection. In this work, we effectively show the underlying risk of relying solely on models that do not include an important (transport) process that can alter the system significantly and propose a combined chemomechanical mechanism for fracture evolution appropriate for this shale mineralogy.

58 GEOSCIENCES↗

Integrated Experimental and Modeling Study of Geochemical Reactions of Simple Fracturing Fluids with Caney Shale

Interactions between rock minerals and hydraulic fluids directly impact the geochemical and geomechanical properties of shale formations. However, the mechanisms of geochemical reactions in shale unconventional reservoirs remain poorly understood. Here, to investigate the geochemical reactions between shale and hydraulic fracturing fluids, a series of batch reactor experiments were undertaken. Three rock samples with different mineralogical compositions and three fluid samples of different compositions (deionized water, deionized water + 2% potassium chloride (KCl), and deionized water + 0.5% choline chloride (C 5 H 14 ClNO) were used. Experiments were undertaken at reservoir temperature and atmospheric pressure. Elemental compositions of effluents after 1, 3, 7, 14, 28 days were analyzed using Inductively Couple Plasma Mass Spectrometry (ICP-MS). Medical Computed Tomography (CT) scan and X-ray Fluorescence (XRF) were conducted on the entire core run to help upscale results obtained from rock-fluid interaction experiments. Geochemical modeling using a reactive simulator, TOUGHREACT, was undertaken to corroborate experimental results. Results show that lower pH triggered high dissolution rates in the rock samples, especially the carbonate components. As pH increased, the rate of dissolution declined significantly, though for most cases dissolution still continued. Observed dissolved silica concentrations were much higher than the quartz solubility, suggesting that much of the silica originates from more soluble silica polymorphs and possibly desorption from clay mineral exchange sites. Concentration of most elemental species in solution increased but aluminium and magnesium concentrations declined rapidly following initial entry into solution. Geochemical modeling corroborated the conclusions regarding mineral dissolution and precipitation observed from experiments, notably; the dissolution of calcite and oxidation of pyrite in reacted shale samples, the likely presence of silica polymorphs such as opal, chalcedony or amorphous silica in these samples, and the reduction of Al and Mg concentrations in solution by precipitation of secondary aluminosilicate phases. The de-flocculation of clay minerals during reaction implies fines migration after hydraulic fracturing. This is detrimental to reservoir productivity as clay fines are displaces and lodged within the micro and nano-fractures created during fracturing. The immediate consumption of aluminium and magnesium also has implications on blockage of hydrocarbon pathways due to precipitation of new minerals in these locations.

04 OIL SHALES AND TAR SANDS↗

Quantifying the Effect of Pore‐Size Dependent Wettability on Relative Permeabilities Using Lattice Boltzmann Simulation

Relative permeability is a crucial two-phase property in porous media that can be significantly impacted by wettability conditions. While traditional research has predominantly examined homogeneous wettability, this work explores the less studied pore-size dependent (PSD) wettability, featured by a pore-size dependent wettability distribution. Leveraging high-fidelity Lattice Boltzmann simulations on CT-scanned porous samples, we demonstrate how PSD wettability would impact relative permeability at the pore scale. Our findings reveal that the deviation of relative permeability from the homogeneous wettabilitity induced by PSD wettability can be 5%–20%. The deviation of relative permeability curves increases as the spanning range of the contact angle increases. We also find that this impact is less pronounced as the capillary number increases. By adopting a pore-size-dependent contact angle relationship, our approach provides a more accurate and nuanced understanding of how PSD wettability would impact two-phase flow. These findings discovered at the pore scale may also provide valuable insights on relative permeability at the core to reservoir scales.

25 ENERGY STORAGE↗

X-ray scatter imaging of hepatocellular carcinoma in a mouse model using nanoparticle contrast agents

Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific, and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form an image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. As a result, the enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Dosimetry of Radiopharmaceuticals for Diagnostic and Therapeutic Nuclear Medicine

A standard formalism for radionuclide internal radiation dosimetry was developed in the 1960s and continues to be refined today. Early work was based on a mathematical phantom but this is being replaced by phantoms developed from whole-body CT scans to give more realistic dose estimates. The largest contributors to the uncertainties in these dose estimates are the errors associated with in vivo activity quantitation, the variability of the biokinetics between patients and the limited information that can be obtained on these kinetics in individual patients. Despite these limitations, pre-treatment patient-specific dosimetry is being increasing used, particularly to limit the toxicity to non-target organs such as the bone marrow.

61 RADIATION PROTECTION AND DOSIMETRY↗

Compact high-resolution gamma-ray computed tomography system for multiphase flow studies

In this paper, a compact high-resolution gamma-ray Computed Tomography (CompaCT) measurement system for multiphase flow studies and tomographic imaging of technical objects is presented. Its compact and robust design makes it particularly suitable for studies on industrial facilities and outdoor applications. Special care has been given to thermal ruggedness, shock resistance, and radiation protection. Main components of the system are a collimated {sup 137}Cs isotopic source, a thermally stabilised modular high-resolution gamma-ray detector arc with 112 scintillation detector elements, and a transportable rotary unit. The CompaCT allows full CT scans of objects with a diameter of up to 130 mm and can be operated with any tilting angle from 0 Degree-Sign (horizontal) to 90 Degree-Sign (vertical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review methods for image segmentation from computed tomography images

Image segmentation is a challenging process in order to get the accuracy of segmentation, automation and robustness especially in medical images. There exist many segmentation methods that can be implemented to medical images but not all methods are suitable. For the medical purposes, the aims of image segmentation are to study the anatomical structure, identify the region of interest, measure tissue volume to measure growth of tumor and help in treatment planning prior to radiation therapy. In this paper, we present a review method for segmentation purposes using Computed Tomography (CT) images. CT images has their own characteristics that affect the ability to visualize anatomic structures and pathologic features such as blurring of the image and visual noise. The details about the methods, the goodness and the problem incurred in the methods will be defined and explained. It is necessary to know the suitable segmentation method in order to get accurate segmentation. This paper can be a guide to researcher to choose the suitable segmentation method especially in segmenting the images from CT scan.

60 APPLIED LIFE SCIENCES↗

Study of dose calculation on breast brachytherapy using prism TPS

PRISM is one of non-commercial Treatment Planning System (TPS) and is developed at the University of Washington. In Indonesia, many cancer hospitals use expensive commercial TPS. This study aims to investigate Prism TPS which been applied to the dose distribution of brachytherapy by taking into account the effect of source position and inhomogeneities. The results will be applicable for clinical Treatment Planning System. Dose calculation has been implemented for water phantom and CT scan images of breast cancer using point source and line source. This study used point source and line source and divided into two cases. On the first case, Ir-192 seed source is located at the center of treatment volume. On the second case, the source position is gradually changed. The dose calculation of every case performed on a homogeneous and inhomogeneous phantom with dimension 20 × 20 × 20 cm{sup 3}. The inhomogeneous phantom has inhomogeneities volume 2 × 2 × 2 cm{sup 3}. The results of dose calculations using PRISM TPS were compared to literature data. From the calculation of PRISM TPS, dose rates show good agreement with Plato TPS and other study as published by Ramdhani. No deviations greater than ±4% for all case. Dose calculation in inhomogeneous and homogenous cases show similar result. This results indicate that Prism TPS is good in dose calculation of brachytherapy but not sensitive for inhomogeneities. Thus, the dose calculation parameters developed in this study were found to be applicable for clinical treatment planning of brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A review of long fibre thermoplastic (LFT) composites [A review of long fibre-reinforced thermoplastic of long fibre thermoplastic (LFT) composites]

Long fibre-reinforced thermoplastic or long fibre thermoplastic (LFT) composites possess superior specific modulus and strength, excellent impact resistance, and other advantages such as ease of processability, recyclability, and excellent corrosion resistance. These advantages make LFT composites one of the most advanced lightweight engineering materials and enable their increasing use in various applications. This review paper summarizes the research and development work that has been conducted on LFT composites since their initial development. Different aspects of LFTs, such as process development, fibre orientation distribution (FOD), fibre length distribution (FLD), and their effects on the mechanical properties of LFT composites are described. The characterization of the FOD and FLD in the LFT composites using advanced imaging technology such as high-resolution 3D micro-CT scanning technique is summarized. Research and development of LFT hybridisation and LFT additives are also discussed. Lastly, conclusions are made and the future outlook of LFT composites is given.

36 MATERIALS SCIENCE↗

2.5D Super-Resolution Approaches for X-Ray Computed Tomography-Based Inspection of Additively Manufactured Parts

X-ray computed tomography (XCT) is a key tool in non-destructive evaluation of additively manufactured (AM) parts, allowing for internal inspection and defect detection. Despite its widespread use, obtaining high-resolution CT scans can be extremely time consuming. This issue can be mitigated by performing scans at lower resolutions; however, reducing the resolution compromises spatial detail, limiting the accuracy of defect detection. Super-resolution algorithms offer a promising solution for overcoming resolution limitations in XCT reconstructions of AM parts, enabling more accurate detection of defects. While 2D super-resolution methods have demonstrated state-of-the-art performance on natural images, they tend to under-perform when directly applied to XCT slices. On the other hand, 3D super-resolution methods are computationally expensive, making them infeasible for large-scale applications. To address these challenges, we propose a 2.5D super-resolution approach tailored for XCT of AM parts. Our method enhances the resolution of individual slices by leveraging multi-slice information from neighboring 2D slices without the significant computational overhead of full 3D methods. Specifically, we use neighboring low-resolution slices to super-resolve the center slice, exploiting inter-slice spatial context while maintaining computational efficiency. This approach bridges the gap between 2D and 3D methods, offering a practical solution for high-throughput defect detection in AM parts.

Sullivan, Haley↗

A novel flexible framework with automatic feature correspondence optimization for nonrigid registration in radiotherapy

Technical improvements in planning and dose delivery and in verification of patient positioning have substantially widened the therapeutic window for radiation treatment of cancer. However, changes in patient anatomy during the treatment limit the exploitation of these new techniques. To further improve radiation treatments, anatomical changes need to be modeled and accounted for. Nonrigid registration can be used for this purpose. This article describes the design, the implementation, and the validation of a new framework for nonrigid registration for radiotherapy applications. The core of this framework is an improved version of the thin plate spline robust point matching (TPS-RPM) algorithm. The TPS-RPM algorithm estimates a global correspondence and a transformation between the points that represent organs of interest belonging to two image sets. However, the algorithm does not allow for the inclusion of prior knowledge on the correspondence of subset of points, and therefore, it can lead to inconsistent anatomical solutions. In this article TPS-RPM was improved by employing a novel correspondence filter that supports simultaneous registration of multiple structures. The improved method allows for coherent organ registration and for the inclusion of user-defined landmarks, lines, and surfaces inside and outside of structures of interest. A procedure to generate control points from segmented organs is described. The framework parameters r and {lambda}, which control the number of points and the nonrigidness of the transformation, respectively, were optimized for three sites with different degrees of deformation (head and neck, prostate, and cervix) using two cases per site. For the head and neck cases, the salivary glands were manually contoured on CT scans, for the prostate cases the prostate and the vesicles, and for the cervix cases the cervix uterus, the bladder, and the rectum. The transformation error obtained using the best set of parameters was below 1 mm for all the studied cases. The lengths of the deformation vectors were on average ({+-}1 standard deviation) 5.8{+-}2.5 and 2.6{+-}1.1 mm for the head and neck cases, 7.2{+-}4.5 and 8.6{+-}1.9 mm for the prostate cases, and 19.0{+-}11.6 and 14.5{+-}9.3 mm for the cervix cases. Distinguishable anatomical features were identified for each case and were used to validate the registration by calculating residual distances after transformation: 1.5{+-}0.8, 2.3{+-}1.0, and 6.3{+-}2.9 mm for the head and neck, prostate, and cervix sites, respectively. Finally, the authors demonstrated how the inclusion of these anatomical features in the registration process reduced the residual distances to 0.8{+-}0.5, 0.6{+-}0.5, and 1.3{+-}0.7 mm for the head and neck, prostate, and cervix sites, respectively. The inclusion of additional anatomical features produced more anatomically coherent transformations without compromising the transformation error. The authors concluded that the presented nonrigid registration framework is a powerful tool to simultaneously register multiple segmented organs with very different complexities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments

Treatment plans are usually designed, optimized, and evaluated based on the total 3D dose distribution, motivating a total 3D dose verification. The purpose of this study was to develop a 2D transmission-dosimetry method using an electronic portal imaging device (EPID) into a simple 3D method that provides 3D dose information. In the new method, the dose is reconstructed within the patient volume in multiple planes parallel to the EPID for each gantry angle. By summing the 3D dose grids of all beams, the 3D dose distribution for the total treatment fraction is obtained. The algorithm uses patient contours from the planning CT scan but does not include tissue inhomogeneity corrections. The 3D EPID dosimetry method was tested for IMRT fractions of a prostate, a rectum, and a head-and-neck cancer patient. Planned and in vivo-measured dose distributions were within 2% at the dose prescription point. Within the 50% isodose surface of the prescribed dose, at least 97% of points were in agreement, evaluated with a 3D {gamma} method with criteria of 3% of the prescribed dose and 0.3 cm. Full 3D dose reconstruction on a 0.1x0.1x0.1 cm{sup 3} grid and 3D {gamma} evaluation took less than 15 min for one fraction on a standard PC. The method allows in vivo determination of 3D dose-volume parameters that are common in clinical practice. The authors conclude that their EPID dosimetry method is an accurate and fast tool for in vivo dose verification of IMRT plans in 3D. Their approach is independent of the treatment planning system and provides a practical safety net for radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tomographic image via background subtraction using an x-ray projection image and a priori computed tomography

Kilovoltage x-ray projection images (kV images for brevity) are increasingly available in image guided radiotherapy (IGRT) for patient positioning. These images are two-dimensional (2D) projections of a three-dimensional (3D) object along the x-ray beam direction. Projecting a 3D object onto a plane may lead to ambiguities in the identification of anatomical structures and to poor contrast in kV images. Therefore, the use of kV images in IGRT is mainly limited to bony landmark alignments. This work proposes a novel subtraction technique that isolates a slice of interest (SOI) from a kV image with the assistance of a priori information from a previous CT scan. The method separates structural information within a preselected SOI by suppressing contributions to the unprocessed projection from out-of-SOI-plane structures. Up to a five-fold increase in the contrast-to-noise ratios (CNRs) was observed in selected regions of the isolated SOI, when compared to the original unprocessed kV image. The tomographic image via background subtraction (TIBS) technique aims to provide a quick snapshot of the slice of interest with greatly enhanced image contrast over conventional kV x-ray projections for fast and accurate image guidance of radiation therapy. With further refinements, TIBS could, in principle, provide real-time tumor localization using gantry-mounted x-ray imaging systems without the need for implanted markers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT image artifacts from brachytherapy seed implants: A postprocessing 3D adaptive median filter

Purpose: To design a postprocessing 3D adaptive median filter that minimizes streak artifacts and improves soft-tissue contrast in postoperative CT images of brachytherapy seed implantations. Methods: The filter works by identifying voxels that are likely streaks and estimating more reflective voxel intensity by using voxel intensities in adjacent CT slices and applying a median filter over voxels not identified as seeds. Median values are computed over a 5x5x5 mm region of interest (ROI) within the CT volume. An acrylic phantom simulating a clinical seed implant arrangement and containing nonradioactive seeds was created. Low contrast subvolumes of tissuelike material were also embedded in the phantom. Pre- and postprocessed image quality metrics were compared using the standard deviation of ROIs between the seeds, the CT numbers of low contrast ROIs embedded within the phantom, the signal to noise ratio (SNR), and the contrast to noise ratio (CNR) of the low contrast ROIs. The method was demonstrated with a clinical postimplant CT dataset. Results: After the filter was applied, the standard deviation of CT values in streak artifact regions was significantly reduced from 76.5 to 7.2 HU. Within the observable low contrast plugs, the mean of all ROI standard deviations was significantly reduced from 60.5 to 3.9 HU, SNR significantly increased from 2.3 to 22.4, and CNR significantly increased from 0.2 to 4.1 (all P<0.01). The mean CT in the low contrast plugs remained within 5 HU of the original values. Conclusion: An efficient postprocessing filter that does not require access to projection data, which can be applied irrespective of CT scan parameters has been developed, provided the slice thickness and spacing is 3 mm or less.

62 RADIOLOGY AND NUCLEAR MEDICINE↗