Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Numerical Study of Vortex Core in Turbulent Swirling Flow

Swirling flow has attracted a great deal of research interest. An application of swirling flow can be found in many engineering areas; such as gas cyclone and heat transfer enhancement. In nuclear engineering, swirling flow is used as heat transfer enhancement in rod bundle by installing grid spacer and mixing vane. Because of its extensive applications, there has been a great number of experimental and numerical investigations of swirling flow. McClusky et al., experimentally studied mapping of the lateral velocity in rod bundle using Laser Doppler Velocimetry (LDV) and Conner et al. predicted the flow field in rod bundle by CFD. To understand the characteristics of swirling flow such as tangential velocity and vortex core swirling flow, some researchers investigated swirling flow in a pipe instead of in rod bundle. This is due to the similarity between swirling flow in a pipe and rod bundle. In recent study, flow mapping of 2D velocity field of single-phase swirling flow had been conducted experimentally by Particle Image Velocimetry (PIV). However, this method needs calibration and complicated. The new measurement technique for flow mapping in swirling flow was done by phased array Ultrasonic Velocity Profiler (PAUVP). Hamdani et al., successfully plotted velocity field and determined the swirling core region (vortex core). This technique is nonintrusive and no need calibration. However, there was a limitation of the measurement because phased array UVP cannot capture 360 deg. velocity field inside the pipe. In addition, tangential velocity in CFD results was not agree well with experiment data due asymmetric problem. To evaluate this limitation of experimental method, the numerical simulations using Computational Fluid Dynamics (CFD) needs to be performed. The objective of this study is to use the commercial CFD code Fluent to model the developing turbulent swirling flow induced by twisted tape inside a straight pipe, and to gain an understanding of such a flow and the turbulence models involved in the simulation. Straight pipe is used instead of rod bundle for a simplification. In this work, the Renormalized Group (RNG) k-{epsilon} turbulence model and Reynolds Stress Model (RSM) turbulence model, are performed to study the phenomena of vortex core in a pipe with twisted tape inserts. Effects of the Reynolds number and asymmetric of twisted tape (inclination, {alpha} = 5 deg. and {alpha} = 20 deg.) on swirling core position are examined using water as the testing fluid. Furthermore, the Navier-Stokes equations will be solved to obtain results that can be validated with the previous experimental results. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DynamicME: dynamic simulation and refinement of integrated models of metabolism and protein expression

Background Genome-scale models of metabolism and macromolecular expression (ME models) enable systems-level computation of proteome allocation coupled to metabolic phenotype. Results We develop DynamicME, an algorithm enabling time-course simulation of cell metabolism and protein expression. DynamicME correctly predicted the substrate utilization hierarchy on a mixed carbon substrate medium. We also found good agreement between predicted and measured time-course expression profiles. ME models involve considerably more parameters than metabolic models (M models). We thus generate an ensemble of models (each model having its rate constants perturbed), and then analyze the models by identifying archetypal time-course metabolite concentration profiles. Furthermore, we use a metaheuristic optimization method to calibrate ME model parameters using time-course measurements such as from a (fed-) batch culture. Finally, we show that constraints on protein concentration dynamics (“inertia”) alter the metabolic response to environmental fluctuations, including increased substrate-level phosphorylation and lowered oxidative phosphorylation. Conclusions Overall, DynamicME provides a novel method for understanding proteome allocation and metabolism under complex and transient environments, and to utilize time-course cell culture data for model-based interpretation or model refinement.

Mathematical & Computational Biology↗

TDC with uncontrolled delay lines: calibration approaches and precision improvement methods

The time-to-digital-converter (TDC) using uncontrolled delay lines has a simple structure and finer measurement precision since the delay cells are pure digital gates that operate at maximum speed. For every incoming hit, two “snapshots” of the delay line are taken by the register array with two strobes separated with a known time interval. With two measurements, propagation delays of each cell in the delay line can be calibrated for the operating temperature and voltage. The two measurements can also be averaged to improve the TDC measurement precision. We will discuss various calibration approaches and present test results in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quality Control and Calibration of the Dual-Polarization Radar at Kwajalein, RMI

Weather radars, recording information about precipitation around the globe, will soon be significantly upgraded. Most of today s weather radars transmit and receive microwave energy with horizontal orientation only, but upgraded systems have the capability to send and receive both horizontally and vertically oriented waves. These enhanced "dual-polarimetric" (DP) radars peer into precipitation and provide information on the size, shape, phase (liquid / frozen), and concentration of the falling particles (termed hydrometeors). This information is valuable for improved rain rate estimates, and for providing data on the release and absorption of heat in the atmosphere from condensation and evaporation (phase changes). The heating profiles in the atmosphere influence global circulation, and are a vital component in studies of Earth s changing climate. However, to provide the most accurate interpretation of radar data, the radar must be properly calibrated and data must be quality controlled (cleaned) to remove non-precipitation artifacts; both of which are challenging tasks for today s weather radar. The DP capability maximizes performance of these procedures using properties of the observed precipitation. In a notable paper published in 2005, scientists from the Cooperative Institute for Mesoscale Meteorological Studies (CIMMS) at the University of Oklahoma developed a method to calibrate radars using statistically averaged DP measurements within light rain. An additional publication by one of the same scientists at the National Severe Storms Laboratory (NSSL) in Norman, Oklahoma introduced several techniques to perform quality control of radar data using DP measurements. Following their lead, the Topical Rainfall Measuring Mission (TRMM) Satellite Validation Office at NASA s Goddard Space Flight Center has fine-tuned these methods for specific application to the weather radar at Kwajalein Island in the Republic of the Marshall Islands, approximately 2100 miles southwest of Hawaii and 1400 miles east of Guam in the tropical North Pacific Ocean. This tropical oceanic location is important because the majority of rain, and therefore the majority of atmospheric heating, occurs in the tropics where limited ground-based radar data are available.

Marks, David A.↗

SU-E-T-485: In Vivo Dosimetry with EBT3 Radiochromic Films for TBI Treatments

Purpose: Total body irradiation (TBI) is a technique that requires special equipment to control “in vivo” the dose to the patient because it is a complex technique performed in extraordinary conditions. There are several devices to perform this task (diodes, TLDs, ionization chambers, MOSFET). In this paper we study the possibility of performing these measurements with radiochromic films EBT3 properly calibrated. This method has been compared to the PTW diodes system for TBI. Methods: Once made the TC to the patients, we measured different thicknesses of the relevant areas of the body (head, neck, chest with or without arms, umbilicus area, knees and ankles); for each of these thicknesses we measured dose rate (cGy / UM) in RW3 phantom, in TBI conditions, with ionization chamber in the center; in turn, the input diode and the output of each configuration is placed to assign dose to each set of diodes. Movie calibration is performed according to manufacturer’s recommendations but TBI conditions. The dose at the center of each thickness compared to a linear interpolation of the dose at the entrance and exit, resulting in an adequate approximation. Finally in each session for each patient put a piece of film (2×2 cm2) at the entrance and another at the exit in each area, obtaining these readings and interpolating the estimated center dose, as with the diodes. Results: These results show a greater homogeneity in the distribution for use with film and validate the use of the same for this task and, if necessary, to avoid purchasing diode group if they have not. Conclusion: By using radiochromic films for this technique gives us a proper calculation of the dose received by the patient in the absence of other methods, or gives us a second additional track that already used normally.

60 APPLIED LIFE SCIENCES↗

Model Calibration vs. Physics-guided Coverage Mapping: Case Study - Pressure Drop Calculations

This work deals with a fundamental question in model validation: given a body of available experiments and an envisaged domain of nuclear reactor operating conditions (referred to as the reactor application), how can one develop a quantitative approach that measures the portion of the prior uncertainties of the reactor application that is covered by the available experiments? Coverage here means that the uncertainties of the reactor application are originating from and behaving in exactly the same way as those observed at the experimental conditions. This approach is valuable as it provides a scientifically defendable criterion by which experimentally measured biases can be credibly extrapolated (i.e., mapped) to biases for the reactor applications. This work focuses on the application of a new methodology, referred to as physics-guided coverage mapping (PCM), to the estimation of hydraulic pressure losses in reactor pipes. PCM provides a generic, calibration-free approach to the mapping of experimental biases by relying on high fidelity physics simulation and information theoretic measure how much of the application domain is covered by the experiments. The idea is to employ the physics models to establish a joint probability distribution that relates the application and the available body of experiments. An information-theoretic measure, referred to as the mutual information, is used to calculate a quantitative metric that measures the inter-dependence between the application and the experiment. A virtual experiment is employed to demonstrate the application of PCM, wherein the pressure drop is calculated for both the experiment and the application using two different flow conditions, i.e., laminar and turbulent, and the experimental values are simulated. All parameters introducing uncertainties, such as geometry, friction factor formulas and their associated parameters are also incorporated. The results obtained with PCM are compared to a conventional calibration-based approach. This work show that the proposed approach can circumvent a number of challenges that face calibration-based methods, such as nonlinearity, ill-posedness and error compensation in high dimensional models with many parameters. This work focus primarily in this summary on parameter uncertainties and how they can be treated using PCM. In a separate summary, discuss performance of PCM under the presence of modeling uncertainties. This simple study has shown that calibration techniques for very simple situations cannot correctly scale the measurements from the experimental to the application domain. It is our view that is occurs primarily due the phenomenon of error compensation where on artificially changes the value of selected parameters to account for all sources of uncertainties. The situation gets more complicated when one calibrates multiple parameters where now the problem could potentially have an infinite number of ways by which the errors can be compensated. (authors)

42 ENGINEERING↗

Pulse Mode Calibration of the Micro Pocket Fission Detector

The Micro-Pocket Fission Detector (MPFD) is a neutron sensor currently under development in the High Temperature Test Laboratory (HTTL) for use as a supporting instrument during material testing experiments performed at TREAT. The detector has the capability to observe the real-time neutron population while surviving the harsh radiation, and temperature conditions, which sets it apart from most neutron sensitive devices. The next step in the instrument development process is to define a method of calibrating pulse-mode operations. This procedure will allow the detector to be calibrated to allow for absolute measurements of localized neutron population in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct sensitivity analysis on the parameterization of crystal plasticity models

Various methods for calibrating crystal plasticity finite element (CPFE) models lead to non-unique input parameter values, which subsequently introduce uncertainty in the predicted mechanical response. Sensitivity analysis (SA) conducted on crystal plasticity models is used to identify how variability in these parameters contribute to output uncertainty. Traditional SA on CPFE parameters uses simplified surrogate models to save computational time. However, the accuracy of the surrogate models depends on the quantity of training data used, and any modeling error can propagate into the SA results, potentially affecting their reliability. In this work, the elementary effects test (EET) method, a global SA technique using direct CPFE simulations was employed, and the results obtained were compared with the First Order Second Moment (FOSM) method. ExaConstit, an open-source GPU-enabled CPFE code, was used to perform the simulations and direct SA. The EET method was accurately able to capture the non-linear effects of all the input parameters on the output and is a valuable approach for reliably attributing parameter sensitivities in CPFE models. Based on the results, efficient strategies to perform future parameter calibration and SA are discussed. Additionally, the SA trends observed in different single crystal orientations closely mirrored the activity of the slip systems.

Elementary Effects Test↗

A general reconstruction of the recent expansion history of the universe

Distance measurements are currently the most powerful tool to study the expansion history of the universe without specifying its matter content nor any theory of gravitation. Assuming only an isotropic, homogeneous and flat universe, in this work we introduce a model-independent method to reconstruct directly the deceleration function via a piecewise function. Including a penalty factor, we are able to vary continuously the complexity of the deceleration function from a linear case to an arbitrary (n+1)-knots spline interpolation. We carry out a Monte Carlo (MC) analysis to determine the best penalty factor, evaluating the bias-variance trade-off, given the uncertainties of the SDSS-II and SNLS supernova combined sample (JLA), compilations of baryon acoustic oscillation (BAO) and H(z) data. The bias-variance analysis is done for three fiducial models with different features in the deceleration curve. We perform the MC analysis generating mock catalogs and computing their best-fit. For each fiducial model, we test different reconstructions using, in each case, more than 10{sup 4} catalogs in a total of about 5× 10{sup 5}. This investigation proved to be essential in determining the best reconstruction to study these data. We show that, evaluating a single fiducial model, the conclusions about the bias-variance ratio are misleading. We determine the reconstruction method in which the bias represents at most 10% of the total uncertainty. In all statistical analyses, we fit the coefficients of the deceleration function along with four nuisance parameters of the supernova astrophysical model. For the full sample, we also fit H{sub 0} and the sound horizon r{sub s}(z{sub d}) at the drag redshift. The bias-variance trade-off analysis shows that, apart from the deceleration function, all other estimators are unbiased. Finally, we apply the Ensemble Sampler Markov Chain Monte Carlo (ESMCMC) method to explore the posterior of the deceleration function up to redshift 1.3 (using only JLA) and 2.3 (JLA+BAO+H(z)). We obtain that the standard cosmological model agrees within 3σ level with the reconstructed results in the whole studied redshift intervals. Since our method is calibrated to minimize the bias, the error bars of the reconstructed functions are a good approximation for the total uncertainty.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing and Mitigating Intraday Variability: Reconstructing Source Structure in Accreting Black Holes with mm-VLBI

The extraordinary physical resolution afforded by the Event Horizon Telescope has opened a window onto the astrophysical phenomena unfolding on horizon scales in two known black holes, M87* and Sgr A*. However, with this leap in resolution has come a new set of practical complications. Sgr A* exhibits intraday variability that violates the assumptions underlying Earth aperture synthesis, limiting traditional image reconstruction methods to short timescales and data sets with very sparse (u, v) coverage. We present a new set of tools to detect and mitigate this variability. We develop a data-driven, model-agnostic procedure to detect and characterize the spatial structure of intraday variability. This method is calibrated against a large set of mock data sets, producing an empirical estimator of the spatial power spectrum of the brightness fluctuations. We present a novel Bayesian noise modeling algorithm that simultaneously reconstructs an average image and statistical measure of the fluctuations about it using a parameterized form for the excess variance in the complex visibilities not otherwise explained by the statistical errors. These methods are validated using a variety of simulated data, including general relativistic magnetohydrodynamic simulations appropriate for Sgr A* and M87*. We find that the reconstructed source structure and variability are robust to changes in the underlying image model. We apply these methods to the 2017 EHT observations of M87*, finding evidence for variability across the EHT observing campaign. The variability mitigation strategies presented are widely applicable to very long baseline interferometry observations of variable sources generally, for which they provide a data-informed averaging procedure and natural characterization of inter-epoch image consistency.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Methods for In-Situ Calibration of Field-Deployable Microphone Phased Arrays

Current field-deployable microphone phased arrays for aeroacoustic flight testing require the placement of hundreds of individual sensors over a large area. Depending on the duration of the test campaign, the microphones may be required to stay deployed at the testing site for weeks or even months. This presents a challenge in regards to tracking the response (i.e., sensitivity) of the individual sensors as a function of time in order to evaluate the health of the array. To address this challenge, two different methods for in-situ tracking of microphone responses are described. The first relies on the use of an aerial sound source attached as a payload on a hovering small Unmanned Aerial System (sUAS) vehicle. The second relies on the use of individually excited ground-based sound sources strategically placed throughout the array pattern. Testing of the two methods was performed in microphone array deployments conducted at Fort A.P. Hill in 2015 and at Edwards Air Force Base in 2016. The results indicate that the drift in individual sensor responses can be tracked reasonably well using both methods. Thus, in-situ response tracking methods are useful as a diagnostic tool for monitoring the health of a phased array during long duration deployments.

Humphreys, William M.↗

Results from the Atacama B-mode Search (ABS) experiment

We report the Atacama B-mode Search is an experiment designed to measure the cosmic microwave background polarization at large angular scales (0ℓ>4). It observes at 145 GHz from a site at 5,190 m elevation in northern Chile. The noise equivalent polarization temperature, or NEQ, is 41 μK√s. One of the unique features of ABS is its use of a rapidly rotating ambient-temperature half-wave plate (HWP) {as the first optical element}. {The HWP spins} at 2.55 Hz to modulate the incident polarized signal at frequencies above where instrument white noise dominates over atmospheric fluctuations and other sources of low-frequency noise. We report here on the analysis of data from a 2,400 deg 2 region of sky. We perform a blind analysis to reduce potential bias. After unblinding, we find agreement with the Planck TE and EE measurements on the same region of sky, {with a derived calibration factor of 00.89 ± 0.1}. We marginally detect polarized dust emission {(at 3.2 σ for EE and 2.2 σ for BB)} and give an upper limit on the tensor-to-scalar ratio of r<2.3 (95% confidence level) with the equivalent of 100 on-sky days of observation. Finally, we also present a new measurement of the polarization of Tau A and introduce new methods for calibration and data analysis associated with HWP-based observations.

79 ASTRONOMY AND ASTROPHYSICS↗

pyFLANK, a graph neural network based null distribution inference model for F ST outlier detection

Detecting genomic regions under selection is essential for understanding how populations adapt to different environments, yet it remains challenging due to the confounding effects of demographic history and linkage disequilibrium (LD). Fixation index (F ST ) is a widely used statistic to identify genomic regions under adaptation. However, identifying genes under selection by defining F ST outliers often remains challenging, owing to confounding effects of underlying demographic history. Traditional methods assume independence among loci and rely on simple demographic models, while newer models perform much better but are computationally expensive and not easily scalable. Here, we present pyFLANK, an open-source and automated Python implementation which detects F ST outliers using a null distribution inferred from quasi-independent loci. Our tool integrates three approaches to identify loci obeying a null distribution: graph neural network (GNN) inference, linkage disequilibrium (LD)-based inference, and user-defined input. Because pyFLANK uses GNN-based inference of quasi-independent loci, it yields a more accurate null model with less need for user parameter input. In simulation experiments, pyFLANK achieved lower false positive rates than current methods while maintaining comparable detection power, indicating that its refined null model better distinguishes true adaptive loci from background variation. The GNN-based model, in particular, detected additional loci associated with phenotypic variance that were not identified by existing methods. Assessments of simulation and real data from different species demonstrate that pyFLANK achieves lower false positive rates compared with other commonly used F ST outlier detectors, while maintaining comparable detection power and excellent computational performance, providing a robust and user-friendly tool for identifying loci under divergent selection. It extends existing F ST outlier frameworks by incorporating explicit LD-aware strategies for null model calibration. The method is intended as a practical and scalable complement to existing genome scan approaches.

FST↗

Calibrating Airplane Instrumentation To Measure Winds

Elaborate combination of techniques used to calibrate wind-measuring instrumentation aboard F104 airplane. Obtains wind profiles more rapidly. Airplane equipped with standard NACA research nose boom, including pressure probes and flow vanes yielding data on static and total pressures, angle of attack, and angle of sideslip. Has ring-laser-gyroscope inertial reference unit, giving linear and angular velocities, linear acceleration, and orientation of airplane. Body-mounted total-temperature sensor also used. Improved method of calibration devised to determine whether winds aloft at and shortly after time of measurement allow safe launch of Space Shuttle. Proves beneficial in other safety- or research-oriented applications in which wind velocities over range of altitudes must be determined in nearly real time.

Haering, Edward A., Jr.↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Second Harmonic Generation Electric Field Triplet Interferometry for Absolute Phasing

We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.

Interfaces↗

Electron-photon coincidence technique for the absolute calibration of VUV detectors

A method is described whereby VUV photon detectors can be accurately calibrated. This method is illustrated by taking the 58.4-nm transition of He as an example. The technique consists of crossing a monoenergetic electron beam with a beam of He atoms. When inelastically scattered electrons which have excited the 2 1P state are detected in coincidence with the 58.4-nm photons emitted in the decay of the excited state, the interaction volume formed by the crossed beams constitutes a standard source of photons. By comparing the number of detected coincidences with the predicted number the calibration can be made. A total detector efficiency of 0.024 + or - 0.003 is obtained for a Galileo 4830 channeltron.

Mcadams, R.↗

Development of IR Contrast Data Analysis Application for Characterizing Delaminations in Graphite-Epoxy Structures

Objective: Develop infrared (IR) flash thermography application based on use of a calibration standard for inspecting graphite-epoxy laminated/honeycomb structures. Background: Graphite/Epoxy composites (laminated and honeycomb) are widely used on NASA programs. Composite materials are susceptible for impact damage that is not readily detected by visual inspection. IR inspection can provide required sensitivity to detect surface damage in composites during manufacturing and during service. IR contrast analysis can provide characterization of depth, size and gap thickness of impact damage. Benefits/Payoffs: The research provides an empirical method of calibrating the flash thermography response in nondestructive evaluation. A physical calibration standard with artificial flaws such as flat bottom holes with desired diameter and depth values in a desired material is used in calibration. The research devises several probability of detection (POD) analysis approaches to enable cost effective POD study to meet program requirements.

Havican, Marie↗