Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chip scale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

James Clerk Maxwell Telescope Spectral and Continuum Imaging of Hyperactive Comet 46P/Wirtanen

The Jupiter-family comet (JFC) 46P/Wirtanen passed the Earth at a distance of 0.077 au on 2018 December 16 UT, presenting a rare opportunity to study the chemical structure of its coma. With the James Clerk Maxwell Telescope we achieved a resolution of 800 km, which is smaller than the scale lengths of some distributed cometary molecules at the comet’s heliocentric distance of 1 au. Spectroscopic observations of the J = 4 - 3 transition of HCN showed generally uniform levels of outgassing activity during the observing period, 2018 December 14–20. Gas expansion velocities were ~0.6 km s{sup -1}, and the derived average HCN production rate was 7.4 × 10{sup 24} mol s{sup -1}. HCN and CH{sub 3}OH emissions were detected at least 30" (1600 km) from the nucleus, and the abundances of these species were typical for a JFC. The radial distribution of CH{sub 3}OH is consistent with an extended source of sublimation such as a population of icy grains—cometary halo ice primaries, or CHIPs—as has been invoked previously to explain hyperactivity in comets. The abundance of H{sub 2}CO is normal if it is a daughter species. HNC and CO were not detected, but a sensitive nondetection of CS implies an unusually low CS:H{sub 2}O ratio of <0.02%. The peak brightness of the 850 μm continuum emissions from icy coma dust particles of size ~1 mm fell from (52 ± 6) to (40 ± 3) mJy beam{sup -1} through the week, while the size of the dust coma remained essentially constant, with dust extending to ~1000 km from the nucleus. The total mass of those particles was ~2 × 10{sup 8} kg.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum Fast Approximate Synthesis Tool (QFAST) v1.0.0

We present QFAST, a quantum synthesis tool designed to produce short circuits and to scale well in practice. Our contributions are: 1) a novel representation of circuits able to encode placement and topology; 2) a hierarchical approach with an iterative refinement formulation that combines "coarse-grained" fast optimization during circuit structure search with a good, but slower, optimization stage only in the final circuit instantiation stage. When compared against state-of-the-art techniques, although not optimal, QFAST can generate much shorter circuits for "time dependent evolution" algorithms used by domain scientists. We also show the composability and tunability of our formulation in terms of circuit depth and running time. For example, we show how to generate shorter circuits by plugging in the best available third party synthesis algorithm at a given hierarchy level. Composability enables portability across chip architectures, which is missing from the available approaches.

Younis, Ed↗

Investigating Amino Acid Heterogeneity in Milligram-Scale Samples of the Murchison CM2 Carbonaceous Chondrite

Analyses of different aliquots of the Tagish Lake meteorite have resulted in amino acid abundance variations of an order of magnitude or more, even when performed using the same techniques, by the same personnel, in the same laboratories (e.g., Simkus et al. 2019). Up to ~five-fold variations have been observed for specific amino acids in different samples of the same meteorite, such as α aminoisobutryic acid (AIB) in Murchison. These variations are often attributed differing sample composition or differing alteration history, neither of which is mutually exclusive. Distinguishing between these two explanations is challenging and time consuming, requiring detailed mineralogical analyses to be performed in conjunction with high precision organics analysis. The potential for innate sample-level heterogeneity presents a significant complication when parsing the effects of different processes or conditions during preparation of meteorite samples for analysis, as differences in organic yields or abundances could be due to differences in laboratory processing or differences among the samples themselves. In this work, we investigated the degree of innate organic heterogeneity present in a single ~250 mg chip of divided into 21 samples.

A. S. Burton↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗

Promoter analysis reveals globally differential regulation of human long non-coding RNA and protein-coding genes

Transcriptional regulation of protein-coding genes is increasingly well-understood on a global scale, yet no comparable information exists for long non-coding RNA (lncRNA) genes, which were recently recognized to be as numerous as protein-coding genes in mammalian genomes. We performed a genome-wide comparative analysis of the promoters of human lncRNA and protein-coding genes, finding global differences in specific genetic and epigenetic features relevant to transcriptional regulation. These two groups of genes are hence subject to separate transcriptional regulatory programs, including distinct transcription factor (TF) proteins that significantly favor lncRNA, rather than coding-gene, promoters. We report a specific signature of promoter-proximal transcriptional regulation of lncRNA genes, including several distinct transcription factor binding sites (TFBS). Experimental DNase I hypersensitive site profiles are consistent with active configurations of these lncRNA TFBS sets in diverse human cell types. TFBS ChIP-seq datasets confirm the binding events that we predicted using computational approaches for a subset of factors. For several TFs known to be directly regulated by lncRNAs, we find that their putative TFBSs are enriched at lncRNA promoters, suggesting that the TFs and the lncRNAs may participate in a bidirectional feedback loop regulatory network. Accordingly, cells may be able to modulate lncRNA expression levels independently of mRNA levels via distinct regulatory pathways. Our results also raise the possibility that, given the historical reliance on protein-coding gene catalogs to define the chromatin states of active promoters, a revision of these chromatin signature profiles to incorporate expressed lncRNA genes is warranted in the future.

59 BASIC BIOLOGICAL SCIENCES↗

Short-Depth QAOA circuits and Quantum Annealing on Higher-Order Ising Models (Rev.2)

The Quantum Alternating Operator Ansatz (QAOA) and Quantum Annealing (QA) are quantum algorithms that are both based on the adiabatic theorem and both have the goal of sampling the optimal solution(s) of combinatorial optimization problems. Quantum annealing has been physically instantiated on D-Wave devices using superconducting flux qubits, and QAOA can be programmed on digital gate-model quantum computers such as the programmable superconducting transmon qubits devices of the IBMQ series, for instance ibm washington. QAOA and QA address the same types of problems, but it is unclear how they will scale to large problem sizes and to larger and higher-fidelity quantum computers. In this article, we present a direct comparison between QAOA, one and two rounds, run on all 127 qubits of ibm washington and QA run on D-Wave Advantage system4.1 and Advantage system6.1. The problems which allow for this comparison are random Ising model problems whose connectivity matches the heavy hexagonal lattice topology of ibm washington and the Pegasus graph connectivity of the two D-Wave devices. We create two classes of problem instances for this comparison: one with higher order terms (ZZZ variable interactions), linear terms, and quadratic terms, and a separate problem type with only linear and quadratic terms. Our QAOA circuits are novel and extremely short depth, with a CNOT depth of 6 per round, which allows whole chip usage of ibm washington’s heavy hexagonal lattice and can be applied to future heavy-hex chips. We also test the effectiveness of the error suppression technique digital dynamical decoupling on the QAOA circuits. The QAOA circuits compiled to ibm washington are composed of several thousand circuit instructions, approximately 3, 000 depending on the details of the circuit, making these some the largest quantum circuits ever executed on a digital quantum processor. QAOA and QA are compared against the classical heuristic algorithm of simulated annealing and all problem instances are exactly solved using CPLEX in order to evaluate which samplers, if any, correctly found the ground state solution(s) of the problem instances. We find that (i) QA outperforms QAOA on all problem instances, (ii) QAOA samples the problems better than random sampling, and (iii) QAOA angle computation exhibits clear parameter concentration across the ensemble of Ising models.

127 Qubits↗

Characterization of small microfluidic valves for studies of mechanical properties of bacteria

Lab-on-a-chip platforms present many new opportunities to study bacterial cells and cellular assemblies. Here, the authors describe a new platform that allows us to apply uniaxial stress to individual bacterial cells while observing the cell and its subcellular assemblies using a high resolution optical microscope. The microfluidic chip consists of arrays of miniature pressure actuated valves. By placing a bacterium under one of such valves and partially closing the valve by externally applied pressure, the cell can be deformed. Although large pressure actuated valves used in integrated fluidic circuits have been extensively studied previously, here the authors downsize those microfluidic valves and use flow channels with rectangular cross-sections to maintain the bacteria in contact with cell culture medium during the experiments. The closure of these valves has not been characterized before. First, these valves are modeled using finite element analysis, and then compared the modeling results with the actual closing profiles of the valves, which is determined from absorption measurements. The measurements and modeling show with good agreement that the deflection of valves is a linear function of externally applied pressure and the deflection scales proportionally to the width of the flow channel. In addition to characterizing the valve, the authors show at a proof-of-principle level that it can be used to deform a bacterial cell at considerable magnitude. They found the largest deformations in 5 μm wide channels where the bacterial width and length increase by 1.6 and 1.25 times, respectively. Narrower and broader channels are less optimal for these studies. Finally, the platform presents a promising approach to probe, in a quantitative and systematic way, the mechanical properties of not only bacterial cells but possibly also yeast and other single-celled organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Laser Doppler blood flow complementary metal oxide semiconductor imaging sensor with analog on-chip processing

A 4x4 pixel array with analog on-chip processing has been fabricated within a 0.35 {mu}m complementary metal oxide semiconductor process as a prototype sensor for laser Doppler blood flow imaging. At each pixel the bandpass and frequency weighted filters necessary for processing laser Doppler blood flow signals have been designed and fabricated. Because of the space constraints of implementing an accurate {omega}{sup 0.5} filter at the pixel level, this has been approximated using the ''roll off'' of a high-pass filter with a cutoff frequency set at 10 kHz. The sensor has been characterized using a modulated laser source. Fixed pattern noise is present that is demonstrated to be repeatable across the array and can be calibrated. Preliminary blood flow results on a finger before and after occlusion demonstrate that the sensor array provides the potential for a system that can be scaled to a larger number of pixels for blood flow imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiplexed color centers in a silicon photonic cavity array

Entanglement distribution is central to the modular scaling of quantum processors and establishing quantum networks. Color centers with telecom-band transitions and long spin coherence times are suitable candidates for long-distance entanglement distribution. However, high-bandwidth memory-enhanced quantum communication is limited by high-yield, scalable creation of efficient spin-photon interfaces. Here, we develop a silicon photonics platform consisting of arrays of bus-coupled cavities. The coupling to a common bus waveguide enables simultaneous access to individually addressable cavity-enhanced T center arrays. We demonstrate frequency-multiplexed operation of two T centers in separate photonic crystal cavities. In addition, we investigate the cavity enhancement of a T center through hybridized modes formed between physically distant cavities. Our results show that bus-coupled arrays of cavity-enhanced color centers could enable efficient on-chip and long-distance entanglement distribution.

Komza, Lukasz↗

High Power SiGe X-Band (8-10 GHz) Heterojunction Bipolar Transistors and Amplifiers

Limited by increased parasitics and thermal effects as the device size becomes large, current commercial SiGe power HBTs are difficult to operate at X-band (8-12 GHz) with adequate power added efficiencies at high power levels. We found that, by changing the heterostructure and doping profile of SiGe HBTs, their power gain can be significantly improved without resorting to substantial lateral scaling. Furthermore, employing a common-base configuration with proper doping profile instead of a common-emitter configuration improves the power gain characteristics of SiGe HBTs, which thus permits these devices to be efficiently operated at X-band. In this paper, we report the results of SiGe power HBTs and MMIC power amplifiers operating at 8-10 GHz. At 10 GHz, 22.5 dBm (178 mW) RF output power with concurrent gain of 7.32 dB is measured at the peak power-added efficiency of 20.0% and the maximum RF output power of 24.0 dBm (250 mW) is achieved from a 20 emitter finger SiGe power HBT. Demonstration of single-stage X-band medium-power linear MMIC power amplifier is also realized at 8 GHz. Employing a 10-emitter finger SiGe HBT and on-chip input and output matching passive components, a linear gain of 9.7 dB, a maximum output power of 23.4 dBm and peak power added efficiency of 16% is achieved from the power amplifier. The MMIC exhibits very low distortion with third order intermodulation (IM) suppression C/I of -13 dBc at output power of 21.2 dBm and over 20dBm third order output intercept point (OIP3).

Ma, Zhenqiang↗

Bio-Inspired Energy-Efficient Nanofabricated Electrical Contacts

Nanoscale electrical contacts, especially those between materials of dissimilar electronic properties, often represent one of the main causes of drops in energy transfer efficiency. They are also among the sources of above-threshold noise, and their performance often decreases over the lifetime of the nanodevices. Scale-down limitations from mesoscopic to nanoscale devices, and likewise, of nanoscale to quantum-scale devices are also impeded by contacts’ quality. Making more reliable, energy-efficient electrical contacts is among the goals of the nanoelectronics research within the framework of energy-efficient electronic systems. This report focuses on the design, nanofabrication, and testing of novel shapes of electrical contacts. Lithography and nanofabrication were utilized to mimic the approximate shape of insect setae for mesoscale contacts design. The contacts are tested for elementary charge transport via I–V curves and for the broadband, 1/f noise. Tests show that contacts design leads to a measurable decrease in the energy necessary to operate a contact as a switch by at least 12–20%, depending on temperature, while broadband noise shows measurably lower power spectra, for bio-inspired contacts. The proposed method is open to modifications and improvements as required by various on-chip applications.

36 MATERIALS SCIENCE↗

High speed ultra-broadband amplitude modulators with ultrahigh extinction >65 dB

Here, we experimentally demonstrate ultrahigh extinction ratio (>65 dB) amplitude modulators (AMs) that can be electrically tuned to operate across a broad spectral range of 160 nm from 1480 – 1640 nm and 95 nm from 1280 – 1375 nm. Our on-chip AMs employ one extra coupler compared with conventional Mach-Zehnder interferometers (MZI), thus form a cascaded MZI (CMZI) structure. Either directional or adiabatic couplers are used to compose the CMZI AMs and experimental comparisons are made between these two different structures. Furthermore, we investigate the performance of CMZI AMs under extreme conditions such as using 95:5 split ratio couplers and unbalanced waveguide losses. Electro-optic phase shifters are also integrated in the CMZI AMs for high-speed operation. Finally, we investigate the output optical phase when the amplitude is modulated, which provides us valuable information when both amplitude and phase are to be controlled. This demonstration not only paves the road to applications such as quantum information processing that requires high extinction ratio AMs but also significantly alleviates the tight fabrication tolerance needed for large-scale integrated photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Protein Factory on a Chip for Rapid Therapeutics

The potential for new, re-emerging, or engineered pandemic threats could challenge our nation's biosecurity, requiring rapid and flexible countermeasure development platforms. In healthcare, one of the main hindrances to the timely development of protein-based therapeutics for cancer, infectious disease, and other diseases has been a slow and expensive quality-controlled production stage. We present a protein-based technology that has the potential to address these crucial problems in biosecurity and healthcare by maximizing protein production and system portability, while minimizing production latency and cost. Specifically, we have developed a reusable, portable first-generation platform that leverages the advantages of cell-free protein synthesis (CFPS) and flow cells to create practical amounts of clinically relevant therapeutics. We have demonstrated that this technology is reusable and programmable, enabling a single platform that can synthesize multiple dosages of various therapeutics and vaccine in the field. Implementing this technology could mitigate pandemic threats by providing a rapidly-deployable (just-in-time), versatile (precision medicine) production of biologic therapeutics to the infected patient’s locale (point-of-care). In drug development, once promising drug variations are identified, the platform can be scaled to quickly produce practical amounts of protein for patient testing in the matter of days (vs. months) at a fraction of the cost of existing technology.

59 BASIC BIOLOGICAL SCIENCES↗

Computational modeling of continuum scale constitutive equations to improve biomass feedstock material handling and conveying systems

Existing design practices for common feedstock handling equipment such as hoppers and screw feeders have not been successful in many situations. The lack of an appropriate toolset to characterize and model biomass flow behavior is deemed the root cause of plugging, stalls, and flow-related issues in biomass handling systems design and operations. New standardized characterization protocols in conjunction with appropriate constitutive models will lead to successful biomass handling system design and operations. This study investigates constitutive models for bulk solid flow based on the first principles to overcome issues in biomass handling. The focus is on two major issues in biomass handling, i.e., initiating and sustaining of flow in the hopper that is widely used in biomass conveying operation. Accordingly, this article focuses on analytical models of biomass hopper flow. Mohr-Coulomb, Drucker-Prager, and modified Cam-clay models are investigated as constitutive bulk solid flow models. Parameters of those models are determined using a set of triaxial tests. Triaxial tests are conducted using the cubical triaxial tester (CTT) in the Food and Biomaterials Lab of the Pennsylvania State University. Milled 1mm corn stover and 2mm wood chip biomass materials having different flow characteristics are examined, and their respective flow behavior out of a hopper are simulated using the Finite Element method implementing identified constitutive models and determined fundamental mechanical properties. It is found that, with the same hopper geometry, ground corn stover 1mm tends to exhibit funnel flow whereas ground Douglas fir 2 mm tends to exhibit mass flow. These simulation results are validated with hopper flow experiments. This study demonstrates how biomass flow problems can be predicted and mitigated by numerically modeled fundamental constitutive equations.

09 BIOMASS FUELS↗

Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing

We have fabricated a wide-bandwidth, high dynamic range, low-noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By adding a DC current and an RF pump tone, we are able to generate parametric amplification using three-wave mixing (3WM). The devices exhibit gain of more than 15 dB across an instantaneous bandwidth from 4 to 8 GHz. The total usable gain bandwidth, including both sides of the signal-idler gain region, is more than 6 GHz. The noise referred to the input of the devices approaches the quantum limit, with less than 1 photon excess noise. We compare these results directly to the four-wave mixing amplification mode, i.e., without DC-biasing. We find that the 3WM mode allows operation with the pump at lower RF power and at frequencies far from the signal. We have used this knowledge to redesign the amplifiers to utilize primarily 3WM amplification, thereby allowing for direct integration into large scale qubit and detector applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Designing Energy Efficient Communication Runtime Systems for Data Centric Programming Models

The insatiable demand of high performance computing is being driven by the most computationally intensive applications such as computational chemistry, climate modeling, nuclear physics, etc. The last couple of decades have observed a tremendous rise in supercomputers with architectures ranging from traditional clusters to system-on-a-chip in order to achieve the petaflop computing barrier. However, with advent of petaflop-plus computing, we have ushered in an era where power efficient system software stack is imperative for execution on exascale systems and beyond. At the same time, computationally intensive applications are exploring programming models beyond traditional message passing, as a combination of Partitioned Global Address Space (PGAS) languages and libraries, providing one-sided communication paradigm with put, get and accumulate primitives. To support the PGAS models, it is critical to design power efficient and high performance one-sided communication runtime system. In this paper, we design and implement PASCoL, a high performance power aware one-sided communication library using Aggregate Remote Memory Copy Interface (ARMCI), the communication runtime system of Global Arrays. For various communication primitives provided by ARMCI, we study the impact of Dynamic Voltage/Frequency Scaling (DVFS) and a combination of interrupt (blocking)/polling based mechanisms provided by most modern interconnects. We implement our design and evaluate it with synthetic benchmarks using an InfiniBand cluster. Our results indicate that PASCoL can achieve significant reduction in energy consumed per byte transfer without additional penalty for various one-sided communication primitives and various message sizes and data transfer patterns.

99 GENERAL AND MISCELLANEOUS↗

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

Innovative Patient Room Lighting System with Integrated Spectrally Adaptive Control

In December of 2013, the U.S. Department of Energy’s SSL R&D Program released a Funding Opportunity Announcement (FOA), that for the first time, contained opportunities for comprehensive application-specific system development. The FOA included opportunities for two applications, one of which was a Patient Room. Philips Lighting Research North America, submitted a proposal for the Patient Room application, and was selected for the complete project award. The award amount was for $497,127, with a Philips Research co-funding commitment 165,709 dollars. The total project value was 662,836 dollars. This project sought to redefine lighting for the patient room application. The goal was to deliver an innovative LED patient suite (patient room and bathroom) lighting system solution that was 40% more energy-efficient than traditional fluorescent incumbent technologies, and would meet all the visual and non-visual needs of patients, caregivers and visitors, and improve the patient experience. State-of-the-art multichannel LED platforms and control technologies that would provide spectral tuning and become part of an intelligent, connected lighting system drove the solution. The project was scoped into four main task areas that included a) System Concept Creation, b) Identification of the Luminaire Portfolio, c) Development of the Connected Lighting Infrastructure, and d) System Performance Validation. Each of the four main tasks were completed and validated extensively over the course the 2 ½ year project. The system concept was created by first developing a lighting design that demonstrated best practices for patient room lighting – illuminance and uniformity for task performance, reduced glare, and convenient controls, in addition to giving patients control over the lighting in their environment. A framework was defined to deliver circadian support via software behaviors. Through that process luminaires were identified from the Philips portfolio that were adaptable – by their form, dimensions, and optical materials – to mix multicolor LED platforms uniformly and deliver target design lumen levels. The Blue Sky luminaire was selected for the patient bed area to give the illusion of skylight while providing white light on the patient bed. Luminaires used existing 2-channel tunable white LED boards, and newly developed 4-channel LED boards. Red-Orange, Blue, Green, and Blue-shifted Yellow LED chips were selected based on spectral characteristics and their ability to produce high quality white light. 4-channel Power over Ethernet (PoE) drivers were developed and firmware written so they would communicate with both 2- and 4-channel boards. These components formed the backbone of the connected lighting infrastructure. Software, flexible and nuanced in its complexity, was written to set behaviors for myriad lighting scenes in the room throughout the 24 hour day – and all could be overridden by manual controls. This included a dynamic tunable white program, three color changing automatic programs that simulated degrees of sunrise to sunset palettes, and an amber night lighting system that offered visual cues for postural stability to minimize the risk of falls. All programs were carefully designed to provide visual comfort for all occupants, support critical task performance for staff, and to support the patient’s 24hr rhythms. A full scale mockup room was constructed in the Philips Cambridge Lab. The lighting system was installed, tested and functionality demonstrated to ensure smooth operation of system components – luminaires, drivers, PoE switches, wall controls, patient remote, and daylight and occupancy sensors. How did the system perform? It met visual criteria, confirmed by calculations, simulations and measurements in the field. It met non-visual criteria, confirmed by setting circadian stimulus (CS) targets and performing calculations using the calculator developed by the Lighting Research Center. Finally, human factors validation studies were conducted to gain insight from real end users in the healthcare profession; surveys were administered, data analyzed, and audio comments captured. The general consensus was positive, with requests to pilot the system in their hospitals. The importance of the research completed under this grant is that it allowed the exploration and development of a unique lighting system, one that would deliver a blend of visual and non-visual criteria in patient room design for today’s healthcare environment. The research investigated the area of multichannel LED technology, multichannel Power over Ethernet (PoE) drivers and their integration with automatic and manual controls as a system – uncovering and meeting challenges along the way. It married visual needs of patients and staff with support for 24 hour rhythms, placing value on the wellbeing of the patient – while successfully saving energy over incumbent technologies. Indications are that the market is ready and willing to invest – multiple healthcare facilities are in line to pilot this system, recognizing its value beyond energy to patient and staff well-being. Its value to the public can best be expressed by a patient support coordinator who, after spending several hours in the room being immersed in the lighting, analyzing all its features, commented: “This re-writes lighting for healthcare”.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗