Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collective Effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Shielding Considerations for CubeSat Structures During Solar Maximum

The purpose of this lessons learned paper is to communicate the utility of shielding in small spacecraft planning for the support of mission assurance and reliability. Numerous SmallSats have been flying in polar low Earth orbit for science, communications, technology demonstrations, and imaging with academic, commercial, and government interests. Shielding has been part of mission assurance and reliability from the advent of long duration spacecraft missions. The Shields-1 CubeSat has been operating in polar low Earth orbit since 16 December 2018 with atomic number (Z)-grade radiation shielding and demonstrates shielding effectiveness. Shields-1 has collected a representative example of solar minimum data in 2019 with eight Teledyne µDosimeters over varying shielding effectivenesses. It serves as current experimental data and has been compared with NOVICE Shielding estimates using the AP8 – AE8 trapped radiation model with the Shields-1 CAD and generic CubeSat three unit (3U) models. Using NOVICE model radiation analysis coding, the shielding effectivenesses, based on a generic CubeSat 3U structure with four electronic boards, were estimated for aluminum wall thicknesses ranging from 0.204 cm to 4.44 cm (0.550 g/cm 2 to 12.0 g/cm 2 ). For modeled polar orbiting spacecraft, solar maximum total ionizing dose (TID) increases by nearly a magnitude for thin-walled aluminum 0.550-g/cm 2 - 0.686-g/cm 2 (0.204-cm – 0.254-cm) typical CubeSat structures. The shielding effectiveness estimated by NOVICE Sigma, which is a shielding sphere approximation around a detector, showed a linear relationship with wall thickness, which increased over the wall thickness by a ratio of 1.43 determined by linear regression analysis. Using NOVICE Adjoint Monte-Carlo Modeling of solar minimum and solar maximum with the inclusion of a worst-case solar particle event over a one-year mission without geomagnetic shielding, the TID for minimum and maximum conditions for a generic 3U with a wall thickness of 0.254 cm is 158 RAD and 1540 RAD, respectively. The modeled total solar maximum TID is over estimated, because at low orbital latitudes a spacecraft will have shielding from the Earth’s magnetic field. However, TID will still be significant at high latitudes over the poles, where a spacecraft is exposed in a solar particle event. In contrast to a thin-walled generic 3U CubeSat, the Shields-1 electronics enclosure has a shielding effectiveness of 21.3 g/cm 2 from NOVICE Sigma modeling and is expected to show reduced total ionizing dose increases during the present active Solar Cycle 25 period. Because solar particle events during solar maximum increase TID on electronic parts with thin-walled shielding in short periods of time, it is a mission assurance and reliability consideration on the mission value of the spacecraft versus adding shielding for risk reduction of premature spacecraft or instrument payload loss. Since the volumes of many instruments and system electronics have reduced with small spacecraft, shielding material costs and weight penalties have diminished. A small spacecraft project budget and schedule may limit traditional radiation-hardened part use and radiation testing requirements, where shielding can contribute to mission assurance and reliability with reduced costs.

Shields-1↗

Collective Neutrino Oscillations and Heavy-element Nucleosynthesis in Supernovae: Exploring Potential Effects of Many-body Neutrino Correlations

In high-energy astrophysical processes involving compact objects, such as core-collapse supernovae or binary neutron star mergers, neutrinos play an important role in the synthesis of nuclides. Neutrinos in these environments can experience collective flavor oscillations driven by neutrino–neutrino interactions, including coherent forward scattering and incoherent (collisional) effects. Recently, there has been interest in exploring potential novel behaviors in collective oscillations of neutrinos by going beyond the one-particle effective or "mean-field" treatments. Here, we seek to explore implications of collective neutrino oscillations, in the mean-field treatment and beyond, for the nucleosynthesis yields in supernova environments with different astrophysical conditions and neutrino inputs. We find that collective oscillations can impact the operation of the νp-process and r-process nucleosynthesis in supernovae. The potential impact is particularly strong in high-entropy, proton-rich conditions, where we find that neutrino interactions can nudge an initial νp-process neutron-rich, resulting in a unique combination of proton-rich low-mass nuclei as well as neutron-rich high-mass nuclei. We describe this neutrino-induced neutron-capture process as the "νi-process." In addition, nontrivial quantum correlations among neutrinos, if present significantly, could lead to different nuclide yields compared to the corresponding mean-field oscillation treatments, by virtue of modifying the evolution of the relevant one-body neutrino observables.

79 ASTRONOMY AND ASTROPHYSICS↗

Waves in a bounded quantum plasma with electron exchange-correlation effects

Within a quantum hydrodynamic model, the collective excitations of the quantum plasma with electron exchange-correlation effects in a nano-cylindrical wave guide are studied both analytically and numerically. The influences of the electron exchange-correlation potential, the radius of the wave guide, and the quantum effect on the dispersion properties of the bounded quantum plasma are discussed. Significant frequency-shift induced by the electron exchange-correlation effect, the radius of the wave guide and the quantum correction are observed. It is found that the influence of the electron exchange-correlation, the radius of the wave guide and the quantum correction on the wave modes in a bounded nano-waveguide are strongly coupled.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dose monitoring and output correction for the effects of scanning field changes with uniform scanning proton beam

Purpose: The output of a proton beam is affected by proton energy, Spread-Out Bragg Peak (SOBP) width, aperture size, dose rate, and the point of measurement. In a uniform scanning proton beam (USPB), the scanning field size is adjusted (including the vertical length and the horizontal width) according to the treatment field size with appropriate margins to reduce secondary neutron production. Different scanning field settings result in beam output variations that are investigated in this study. Methods: The measurements are performed with a parallel plate Markus chamber at the center of SOBP under the reference condition with 16 cm range, 10 cm SOBP, and 5 cm air gap. The effect of dose rate on field output is studied by varying proton beam current from 0.5 to 7 nA. The effects of scanning field settings are studied by varying independently the field width and length from 12 x 12 to 30 x 30 cm{sup 2}. Results: The results demonstrate that scanning field variations can produce output variation up to 3.80%. In addition, larger output variation is observed with scanning field changes along the stem direction of the patient dose monitor (PDM). By investigating the underlying physics of incomplete charge collection and the stem effects of the PDM, an analytical model is proposed to calculate USPB output with consideration of the scanning field area and the PDM stem length that is irradiated. The average absolute difference between the measured output and calculated output using our new correction model are within 0.13 and 0.08% for the 20 and 30 cm snouts, respectively. Conclusions: This study proposes a correction model for accurate USPB output calculation, which takes account of scanning field settings and the PDM stem effects. This model may be used to extend the existing output calculation model from one snout size to other snout sizes with customized scanning field settings. The study is especially useful for calculating field output for treatment without individualized patient specific measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantum Bohm correction to polarization spectrum of graphene

In this paper, by using a quantum hydrodynamic plasma model which incorporates the important quantum statistical pressure and electron diffraction force, we present the corrected plasmon dispersion relation for graphene which includes a k{sup 4} quantum term arising from the collective electron density wave interference effects. This correction may well describe the shortcoming of the previous results based on the classical hydrodynamics and confirms that the quantum hydrodynamic model may be as effective as the random phase approximation in successful description of the collective density excitations in quantum plasmas. It is clearly observed that the quantum correction due to the collective interaction of electron waves gives rise to significant contribution in the dispersion behavior of the collective plasmon density waves in a wide range of wavelength, as a fundamental property of the monolayer atom-thick graphene. It is revealed that the plasmon density-perturbation linear phase-speed in graphene possesses some universal minimum characteristic value, in the absence of an external magnetic field. It is further remarked that such correction also has important effect on the dielectric function, hence on the impurity screening, in graphene.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of data collection taking radiation damage into account

Software implementing a new method for the optimal choice of data-collection parameters, accounting for the effects of radiation damage, is presented. To take into account the effects of radiation damage, new algorithms for the optimization of data-collection strategies have been implemented in the software package BEST. The intensity variation related to radiation damage is approximated by log-linear functions of resolution and cumulative X-ray dose. Based on an accurate prediction of the basic characteristics of data yet to be collected, BEST establishes objective relationships between the accessible data completeness, resolution and signal-to-noise statistics that can be achieved in an experiment and designs an optimal plan for data collection.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sci-Fri AM: MRI and Diagnostic Imaging - 02: Quality Improvement: Diagnostic Reference Levels for Interior Health CT exams – L-Spine, Chest/Abdomen/pelvis, Abdomen/Pelvis, Head

Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used in this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.

60 APPLIED LIFE SCIENCES↗

Investigations On Historic Centers In Seismic Areas: Guidelines For The Diagnosis

After the earthquake that hit central Italy in 1979, many small historic centers were restored. A subsequent seismic event occurred in 1997 in Umbria-Marche regions revealed that some techniques used in the previous interventions were not successful due to low durability of new materials and/or incompatibility between the new and the existing materials and structures. An extensive investigation on four small typical historic centers in Umbria was carried out. The objectives of the research were: (i) to define a methodology for the vulnerability analysis of historic buildings at the level of the historic centre, (ii) to collect information on the effectiveness of the repair techniques both traditional and new, (iii) to set up Databases storing the information useful to prepare rescue plans, (iv) to use the collected knowledge for the implementation of reliable models for the vulnerability analysis, (v) to prepare guidelines for investigation and vulnerability analysis.

58 GEOSCIENCES↗

Factors influencing moisture analysis in the 3013 destructive examination surveillance program

Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material stored in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.

3013↗

Polarity effects and apparent ion recombination in microionization chambers

Purpose: Microchambers demonstrate anomalous voltage-dependent polarity effects. Existing polarity and ion recombination correction factors do not account for these effects. As a result, many commercial microchamber models do not meet the specification of a reference-class ionization chamber as defined by the American Association of Physicists in Medicine. The purpose of this investigation is to determine the cause of these voltage-dependent polarity effects. Methods: A series of microchamber prototypes were produced to isolate the source of the voltage-dependent polarity effects. Parameters including ionization-chamber collecting-volume size, stem and cable irradiation, chamber assembly, contaminants, high-Z materials, and individual chamber components were investigated. Measurements were performed with electrodes coated with graphite to isolate electrode conductivity. Chamber response was measured as the potential bias of the guard electrode was altered with respect to the collecting electrode, through the integration of additional power supplies. Ionization chamber models were also simulated using COMSOL Multiphysics software to investigate the effect of a potential difference between electrodes on electric field lines and collecting volume definition. Results: Investigations with microchamber prototypes demonstrated that the significant source of the voltage-dependent polarity effects was a potential difference between the guard and collecting electrodes of the chambers. The voltage-dependent polarity effects for each prototype were primarily isolated to either the guard or collecting electrode. Polarity effects were reduced by coating the isolated electrode with a conductive layer of graphite. Polarity effects were increased by introducing a potential difference between the electrodes. COMSOL simulations further demonstrated that for a given potential difference between electrodes, the collecting volume of the chamber changed as the applied voltage was altered, producing voltage-dependent polarity effects in the chamber response. Ionization chamber measurements and COMSOL simulations demonstrated an inverse relationship between the chamber collecting volume size and the severity of voltage-dependent polarity effects on chamber response. The effect of a given potential difference on chamber polarity effects was roughly ten times greater for microchambers as compared to Farmer-type chambers. Stem and cable irradiations, chamber assembly, contaminants, and high-Z materials were not found to be a significant source of the voltage-dependent polarity effects. Conclusions: A potential difference between the guard and collecting electrodes was found to be the primary source of the voltage-dependent polarity effects demonstrated by microchambers. For a given potential difference between electrodes, the relative change in the collecting volume is smaller for larger-volume chambers, illustrating why these polarity effects are not seen in larger-volume chambers with similar guard and collecting electrode designs. Thus, for small-volume chambers, it is necessary to reduce the potential difference between the guard and collecting electrodes in order to reduce polarity effects for reference dosimetry measurements.

60 APPLIED LIFE SCIENCES↗

Extended Defects in Cdznte Radiation Detectors

Large-volume CdZnTe (CZT) single crystals with electron lifetime exceeding 10 mus have recently become commercially available. This opened the opportunity for making room temperature CZT gamma-ray detectors with extended thicknesses and larger effective areas. However, the extended defects that are present even in the highest-quality material remain a major drawback which affects the availability and cost of large CZT detectors. In contrast to the point defects that control electron lifetime and whose effects on the charge collection can be electronically corrected, the extended defects introduce significant fluctuations in the collected charge, which increase with a crystal's thickness. The extended defects limit the uniformity in the electrons' drift distance in CZT crystals, above which electron trapping cannot effectively be corrected. In this paper, we illustrate the roles of the extended defects in CZT detectors with different geometries. We emphasize that the crystallinity of commercial CZT materials remains a major obstacle on the path to developing thick, large-volume CZT detectors for gamma-ray imaging and spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Supernova neutrinos and antineutrinos: ternary luminosity diagram and spectral split patterns

In core-collapse supernovae, the ν{sub e} and ν-bar {sub e} species may experience collective flavor swaps to non-electron species ν{sub x}, within energy intervals limited by relatively sharp boundaries (''splits''). These phenomena appear to depend sensitively upon the initial energy spectra and luminosities. We investigate the effect of generic variations of the fractional luminosities (l{sub e}, l{sub ē}, l{sub x}) with respect to the usual ''energy equipartition'' case (1/6, 1/6, 1/6), within an early-time supernova scenario with fixed thermal spectra and total luminosity. We represent the constraint l{sub e}+l{sub ē}+4l{sub x} = 1 in a ternary diagram, which is explored via numerical experiments (in single-angle approximation) over an evenly-spaced grid of points. In inverted hierarchy, single splits arise in most cases, but an abrupt transition to double splits is observed for a few points surrounding the equipartition one. In normal hierarchy, collective effects turn out to be unobservable at all grid points but one, where single splits occur. Admissible deviations from equipartition may thus induce dramatic changes in the shape of supernova (anti)neutrino spectra. The observed patterns are interpreted in terms of initial flavor polarization vectors (defining boundaries for the single/double split transitions), lepton number conservation, and minimization of potential energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Solvent friction effects propagate over the entire protein molecule through low-frequency collective modes

Protein solvation dynamics has been investigated using atom-dependent Langevin friction coefficients derived directly from molecular dynamics (MD) simulations. To determine the effect of solvation on the atomic friction coefficients, solution and vacuum MD simulations were performed for lysozyme and staphylococcal nuclease and analyzed by Langevin mode analysis. The coefficients thus derived are roughly correlated with the atomic solvent-accessible surface area (ASA), as expected from the fact that friction occurs as the result of collisions with solvent molecules. However, a considerable number of atoms with higher friction coefficients are found inside the core region. Hence, the influence of solvent friction propagates into the protein core. The internal coefficients have large contributions from the low-frequency modes, yielding a simple picture of the surface-to-core long-range damping via solvation governed by collective low-frequency modes. To make use of these findings in implicit-solvent modeling, we compare the all-atom friction results with those obtained using Langevin dynamics (LD) with two empirical representations: the constant-friction and the ASA-dependent (Pastor Karplus) friction models. The constant-friction model overestimates the core and underestimates the surface damping whereas the ASA-dependent friction model, which damps protein atoms only on the solvent-accessible surface, reproduces well the friction coefficients for both the surface and core regions observed in the explicit-solvent MD simulations. Furthermore, in LD simulation, the solvent friction coefficients should be imposed only on the protein surface.

59 BASIC BIOLOGICAL SCIENCES↗

Spectral regularisation: induced gravity and the onset of inflation

Using spectral regularisation, we compute the Weyl anomaly and express the anomaly generating functional of the quantum effective action through a collective scalar degree of freedom of all quantum vacuum fluctuations. Such a formulation allows us to describe induced gravity on an equal footing with the anomaly-induced effective action, in a self-consistent way. We then show that requiring stability of the cosmological constant under loop quantum corrections, Sakharov's induced gravity and Starobinsky's anomaly-induced inflation are either both present or both absent, depending on the particle content of the theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Local field and radiative relaxation rate in a dielectric medium

The effect of macroscopic parameters of a substance on the optical characteristics of impurity particles is investigated. A generalized control equation is derived for two-level emitters forming an ensemble of optical centers in a transparent dielectric medium. In this equation, the effective values of the acting pump field and the radiative relaxation rate of an optical center are taken into account. The formalism developed here is a completely microscopic approach based on the chain of the Bogoliubov-Born-Green-Kirkwood-Yvon equations for reduced density matrices and correlation operators for material particles and modes of a quantized radiation field. The method used here makes it possible to take into account the effects of individual and collective behavior of emitters, which are associated with the presence of an intermediate medium, consistently without using phenomenological procedures. It is shown that the resultant analytic expression for the effective lifetime of the excited state of an optical center conforms with experimental data.

36 MATERIALS SCIENCE↗

Atmospheric Transmission Spectroscopy of Hot Jupiter KELT-10b using Synthetic Telluric Correction Software

High-resolution spectroscopic visible data were obtained with the Ultraviolet and Visible Echelle Spectrograph on the Very Large Telescope. Our goal was to analyze the data in an effort to detect the presence of sodium in the atmosphere of hot Jupiter exoplanet KELT-10b, as well as characterize the orbit of the planet via the Rossiter-McLaughlin effect. Eighty spectra were collected during a single transit of KELT-10b. After standard spectroscopic calibration using ESO-Reflex, the synthetic telluric modeling software molecfit was applied to remove terrestrial atmospheric effects, and to refine the wavelength calibration. Sodium is recognized by its characteristic absorption doublet located at 5895.924 and 5889.951 Å, which can be seen in the planet atmosphere transmission spectrum and through excess absorption during the transit. The radial velocity of the host star was analyzed by measuring the average shift of absorption features from spectrum to spectrum. Our results indicate a sodium detection in the planet transmission spectrum with a line contrast of 0.66% and 0.43% ± 0.09% for the sodium DII and DI lines, respectively. Excess absorption measurements agree to within one half combined standard deviation between the planet transmission spectrum (0.143% ± 0.020%, a 7σ detection) and during the time series (0.124% ± 0.034%, a 3.6σ detection) in a band 1.25 Å wide. The wavelength grid corrections provided by molecfit were insufficient to determine radial velocities and measure the Rossiter-McLaughlin effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-160: Commissioning of a Single-Room Double-Scattering Proton Therapy System

Purpose: To report the detailed commissioning experience for a compact double-scattering Mevion S250 proton therapy system at a University Cancer Center site. Methods: The commissioning of the proton therapy system mainly consisted of ensuring integrity of mechanical and imaging system, beam data collection, and commissioning of a treatment planning system (TPS). First, mechanical alignment and imaging were tested including safety, interlocks, positional accuracy of couch and gantry, image quality, mechanical and imaging isocenter and so on. Second, extensive beam data (outputs, PDDs, and profiles) were collected and analyzed through effective sampling of range (R) and modulation width (M) from 24 beam options. Three different output (cGy/MU) prediction models were also commissioned as primary and secondary MU calculation tool. Third, the Varian Eclipse TPS was commissioned through five sets of data collections (in-water Bragg peak scans, in-air longitudinal fluence scans, in-air lateral profiles, in-air half-beam profiles, and an HU-to-stopping-power conversion curve) and accuracy of TPS calculation was tested using in-water scans and dose measurements with a 2D array detector with block and range compensator. Finally, an anthropomorphic phantom was scanned and heterogeneity effects were tested by inserting radiochromic films in the phantom and PET activation scans for range verification in conjunction with end-to-end test. Results: Beam characteristics agreed well with the vendor specifications; however, minor mismatches in R and M were found in some measurements during the beam data collection. These were reflected into the TPS commissioning such that the TPS could accurately predict the R and M within tolerance levels. The output models had a good agreement with measured outputs (<3% error). The end-to-end test using the film and PET showed reasonably the TPS predicted dose, R and M in heterogeneous medium. Conclusion: The proton therapy system was successfully commissioned and was released for clinical use.

60 APPLIED LIFE SCIENCES↗