Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collective flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Inducer Hydrodynamic Forces in a Cavitating Environment

Marshall Space Flight Center has developed and demonstrated a measurement device for sensing and resolving the hydrodynamic loads on fluid machinery. The device - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining the amplitude and frequency content associated with operating in various cavitation modes. The rotating balance was calibrated statically using a dead-weight load system in order to generate the 6 x 12 calibration matrix later used to convert measured voltages to engineering units. Structural modeling suggested that the rotating assembly first bending mode would be significantly reduced with the balance s inclusion. This reduction in structural stiffness was later confirmed experimentally with a hammer-impact test. This effect, coupled with the relatively large damping associated with the rotating balance waterproofing material, limited the device s bandwidth to approximately 50 Hertz Other pre-test validations included sensing the test article rotating assembly built-in imbalance for two configurations and directly measuring the assembly mass and buoyancy while submerged under water. Both tests matched predictions and confirmed the device s sensitivity while stationary and rotating. The rotating balance was then demonstrated in a water test of a full-scale Space Shuttle Main Engine high-pressure liquid oxygen pump inducer. Experimental data was collected a scaled operating conditions at three flow coefficients across a range of cavitation numbers for the single inducer geometry and radial clearance. Two distinct cavitation modes were observed symmetric tip vortex cavitation and alternate-blade cavitation. Although previous experimental tests on the same inducer demonstrated two additional cavitation modes at lower inlet pressures, these conditions proved unreachable with the rotating balance installed due to the intense dynamic environment. The sensed radial load was less influenced by flow coefficient than by cavitation number or cavitation mode although the flow coefficient range was relatively narrow. Transition from symmetric tip vortex to alternate-blade cavitation corresponded to changes in both radial load magnitude and radial load orientation relative to the inducer. Sensed moments indicated that the effective load center moved downstream during this change in cavitation mode. An occurrence of "higher+rdex cavitation" was also detected in both the stationary pressures and the rotating balance data although the frequency of the phenomena was well above the reliable bandwidth of the rotating balance. In summary the experimental tests proved both the concept and device s capability despite the limitations and confirmed that hydrodynamically-induced forces and moments develop in response to the unbalanced pressure field, which is, in turn, a product of the cavitation environment.

Skelley, Stephen E.↗

Design and Testing of Trace Contaminant Injection and Monitoring Systems

In support of the Carbon dioxide And Moisture Removal Amine Swing-bed (CAMRAS) testing, a contaminant injection system as well as a contaminant monitoring system has been developed by the Johnson Space Center Air Revitalization Systems (JSC-ARS) team. The contaminant injection system has been designed to provide trace level concentrations of contaminants generated by humans in a closed environment during space flight missions. The contaminant injection system continuously injects contaminants from three gas cylinders, two liquid reservoirs and three permeation ovens. The contaminant monitoring system has been designed to provide real time gas analysis with accurate flow, humidity and gas concentration measurements for collection during test. The contaminant monitoring system consists of an analytical real time gas analyzer, a carbon monoxide sensor, and an analyzer for ammonia and water vapor.

Broerman, Craig D.↗

NASA HECC Geometry and Performance Review Part 3: A Numerical and Experimental Investigation of Tip Clearance Effects on the Vaneless Diffuser Configuration

Tip clearance effects in centrifugal compressors have been extensively investigated to understand the losses associated with the flow in the impeller tip clearance gap between the rotating blades and the stationary shroud. In Part 3 of this multipart investigation, experimental data and validated numerical simulations from Parts 1 and 2 were used to analyze the effects of the size of the tip clearance gap on the High Efficiency Centrifugal Compressor performance and aerodynamics. Four tip clearance gaps ranging from 0.012-in to 0.030-in (2.0% to 4.9% of the impeller exit blade height) were considered at both design and off-design operating conditions. The total pressure ratio and efficiency of the stage are found to decay linearly with increasing tip gaps. The sensitivity of the impeller performance to the tip gap was found to vary with the rotational speed of the compressor. Spanwise surveys of flow angle, total pressure, and total temperature collected at the impeller exit at design speed are used to validate numerical simulations at each experimental tip gap condition. Numerical simulations show that increased turbulence kinetic energy near the shroud at larger tip gaps leads to spanwise mixing of high entropy fluid near the impeller trailing edge which decreases the useful work input by the impeller. The data presented have been made available to the public in the HECC Data Archive located at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

NASA HECC Geometry and Performance Review Part 3: A Numerical and Experimental Investigation of Tip Clearance Effects on the Vaneless Diffuser Configuration

Tip clearance effects in centrifugal compressors have been extensively investigated to understand the losses associated with the flow in the impeller tip clearance gap between the rotating blades and the stationary shroud. In Part 3 of this multipart investigation, experimental data and validated numerical simulations from Parts 1 and 2 were used to analyze the effects of the size of the tip clearance gap on the High Efficiency Centrifugal Compressor performance and aerodynamics. Four tip clearance gaps ranging from 0.012-in to 0.030-in (2.0% to 4.9% of the impeller exit blade height) were considered at both design and off-design operating conditions. The total pressure ratio and efficiency of the stage are found to decay linearly with increasing tip gaps. The sensitivity of the impeller performance to the tip gap was found to vary with the rotational speed of the compressor. Spanwise surveys of flow angle, total pressure, and total temperature collected at the impeller exit at design speed are used to validate numerical simulations at each experimental tip gap condition. Numerical simulations show that increased turbulence kinetic energy near the shroud at larger tip gaps leads to spanwise mixing of high entropy fluid near the impeller trailing edge which decreases the useful work input by the impeller. The data presented have been made available to the public in the HECC Data Archive located at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system operations control strategy.

Ceiling Panels↗

Effects of Adenovirus-Mediated Delivery of the Human Hepatocyte Growth Factor Gene in Experimental Radiation-Induced Heart Disease

Purpose: Irradiation to the heart may lead to late cardiovascular complications. The purpose of this study was to investigate whether adenovirus-mediated delivery of the human hepatocyte growth factor gene could reduce post-irradiation damage of the rat heart and improve heart function. Methods and Materials: Twenty rats received single-dose irradiation of 20 Gy gamma ray locally to the heart and were randomized into two groups. Two weeks after irradiation, these two groups of rats received Ad-HGF or mock adenovirus vector intramyocardial injection, respectively. Another 10 rats served as sham-irradiated controls. At post-irradiation Day 120, myocardial perfusion was tested by myocardial contrast echocardiography with contrast agent injected intravenously. At post-irradiation Day 180, cardiac function was assessed using the Langendorff technique with an isolated working heart model, after which heart samples were collected for histological evaluation. Results: Myocardial blood flow was significantly improved in HGF-treated animals as measured by myocardial contrast echocardiography at post-irradiation Day 120 . At post-irradiation Day 180, cardiac function was significantly improved in the HGF group compared with mock vector group, as measured by left ventricular peak systolic pressure (58.80 +- 9.01 vs. 41.94 +- 6.65 mm Hg, p < 0.05), the maximum dP/dt (5634 +- 1303 vs. 1667 +- 304 mm Hg/s, p < 0.01), and the minimum dP/dt (3477 +- 1084 vs. 1566 +- 499 mm Hg/s, p < 0.05). Picrosirius red staining analysis also revealed a significant reduction of fibrosis in the HGF group. Conclusion: Based on the study findings, hepatocyte growth factor gene transfer can attenuate radiation-induced cardiac injury and can preserve cardiac function.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Testing Results from the Low Activity Waste Pretreatment System (LAWPS) Full-Scale Ion Exchange Column Test and Engineering Scale Integrated System Test - 18634

The U.S. Department of Energy (DOE), Office of River Protection's (ORP) primary mission is to retrieve and treat Hanford's tank waste and close the Tank Farms to protect the Columbia River. Mixed radioactive waste is stored in 177 underground tanks at the Hanford Site as reported in DOE/ORP 2003- 02, Environmental Impact Statement for Retrieval, Treatment, and Disposal of Tank Waste and Closure of the Single Shell Tanks at the Hanford Site, Richland WA, Inventory and Source Term Data Package. The 177 underground tanks are estimated to contain about 56 million gallons of waste. The Low Activity Waste Pretreatment System (LAWPS) Project provides for the early production of immobilized low activity waste (ILAW) by feeding LAW directly from Tank Farms to the Hanford Waste Treatment Plant's (WTP's) LAW Facility, bypassing the Pretreatment Facility. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated in the LAWPS to meet the WTP LAW waste acceptance criteria. The LAWPS will also facilitate the return of secondary liquid wastes from the WTP LAW Vitrification Facility to the Tank Farms. In November of 2015 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to the AECOM team to design, fabricate and operate two test platforms to generate performance data at two different scales and demonstrate technology maturation. The first platform models the ion exchange (IX) columns at full scale, and the second platform models the integrated flowsheet (cross flow filter (CFF) and IX) at 1/9. scale. Overarching technical objectives of performing the full-scale ion exchange test and the engineering-scale integrated test are to: 1. Test interactions between unit process operations; 2. Test removal of non-radioactive cesium from process stream; 3. Test removal of undissolved solids from process stream; 4. Confirm operational flow rate range and stability; 5. Confirm volumetric throughput of waste stream over flow operating range; 6. Confirm range of process temperatures over planned operating range; 7. Establish system hydraulics and process criteria; 8. Coordinate key control and monitoring components; 9. Establish treated product chemistry meets requirements (cesium, solids, and pH); and 10. Test the hazard control strategy for a no flow condition through the IX column. Data collected during testing will be used by WRPS to validate the preliminary design, inform the final design of the permanent plant equipment, and demonstrate that the critical technology elements have advanced to a technology readiness level of 6 (prototypical system validation in a relevant environment). Testing on both platforms started in fall of 2016 generating NQA-1 data. This paper covers test results from the first five phases of testing on the 1/9. scale integrated test platform. A further three phases of testing are currently being executed, these including a 5.6 M sodium simulant containing foulant, a high viscosity simulant and finally a run performed with a lower Cs concentration (all earlier tests were spiked to 4 x Cs to reduce volume and cost). Results from these tests were not available at the time of writing available. Results are also presented from the full scale IX testing. Eight test were performed covering column loading, elution and regeneration; column loading, elution and regeneration with upflow displacement; IX column loading and gas migration; resin removal; solids accumulation; and IX column emergency recirculation and vent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theoretical analyses of aerosol aging on a substrate without wall-effects by a cross-flow

Long time ({approx}1 day) aging or reactions of aerosol is typically studied using either large aerosol chambers (> 10 m3) or particles supported on a substrate to minimize wall effects. To avoid wall effects in the latter, it is often essential that the wall reactivity be extremely small (<< 10-5 reactions per encounter) and that the particle loadings be very small (< 1 pg/cm2) to eliminate transport-limited trace gas depletion near the particles and substrate. We evaluate here a cross-flow approach, which greatly reduces these constraints. Particles are to be supported on a micromesh ({approx}50% or more open area) through which the reactive gas is drawn at around a few hundred cm/s. The analysis shows how the competitions between flow and diffusion establishes a 'zone of isolation' several microns wide around each reactive particle, outside of which the reactivity of other particles or the substrate are irrelevant to the local reactions. This cross-flow approach reduces the effects of substrate and collective particle reactivity typically orders of magnitude, and will facilitate aging studies of supported aerosols.

54 ENVIRONMENTAL SCIENCES↗

A Network Management System for Handling Scientific Data Flows

Large scientific data transfers often occur at high rates causing increased burstiness in Internet traffic. To limit the adverse effects of these high-rate large-sized flows, which are referred to as $\alpha $ flows, on delay-sensitive audio/video flows, a network management system called Alpha Flow Traffic Engineering System (AFTES) is proposed for intra-domain traffic engineering. An offline approach is used in which AFTES analyzes NetFlow records collected by routers, extracts source–destination address prefixes of $\alpha $ flows, and uses these prefixes to configure firewall filters at ingress routers of a provider’s network to redirect future $\alpha $ flows to traffic-engineered paths and isolated queues. The effectiveness of this scheme was evaluated through an analysis of 7 months of NetFlow data obtained from an ESnet router. For this data set, 91 % of bytes generated by $\alpha $ flows during high-rate intervals would have been directed had AFTES been deployed. The negative aspect of using address prefixes in firewall filters, i.e., the redirection of $\beta $ flows to $\alpha $-flow paths/queues, was also quantified.

97 MATHEMATICS AND COMPUTING↗

On the Scaling and Growth Limit of Fluvial Dunes

Abstract Bedforms emerge in a variety of shapes and sizes when a granular erodible surface is subject to a strong enough shear flow, as observed in topographic data from submarine canyons, rivers, deserts, and planetary bodies. The two salient features of bedforms are the ability to collectively transport particles, and to generate form drag thus increasing flow resistance. These two mechanisms are in competition and contribute to force bedforms of increasing size migrating more slowly. In a dedicated large‐scale open channel flow facility, hierarchies of fluvial bedforms were generated and measured in equilibrium conditions. The corresponding scale‐dependent migration velocity and mass flux contributions were quantified in the wave number and frequency domains. Experimental results are paired with a validated set of theoretical models to demonstrate that ripples or dunes reach an equilibrium state when drag partitioning ensures high enough frictional drag to sustain the bedload transport of sediment, and low enough form drag to enable the migration of the largest bedform size. This mechanism is inferred to constrain the growth of bedforms when sediment supply is not the limiting factor.

58 GEOSCIENCES↗

Multigrid Relaxation of a Factorizable, Conservative Discretization of the Compressible Flow Equations

The second-order factorizable discretization of the compressible Euler equations developed by Sidilkover is extended to conservation form on general curvilinear body-fitted grids. The discrete equations are solved by symmetric collective Gauss-Seidel relaxation and FAS multigrid. Solutions for flow in a channel with Mach numbers ranging from 0.0001 to a supercritical Mach number are shown, demonstrating uniform convergence rates and no loss of accuracy in the incompressible limit. A solution for the flow around the leading edge of a semi-infinite parabolic body demonstrates that the scheme maintains rapid convergence for a flow containing a stagnation point.

Roberts, Thomas W.↗

A New Method for Breath Capture Inside a Space Suit Helmet

This project investigates methods to capture an astronaut's exhaled carbon dioxide (CO2) before it becomes diluted with the high volumetric oxygen flow present within a space suit. Typical expired breath contains CO2 partial pressures (pCO2) in the range of 20-35 mm Hg. This research investigates methods to capture the concentrated CO2 gas stream prior to its dilution with the low pCO2 ventilation flow. Specifically this research is looking at potential designs for a collection cup for use inside the space suit helmet. The collection cup concept is not the same as a breathing mask typical of that worn by firefighters and pilots. It is well known that most members of the astronaut corps view a mask as a serious deficiency in any space suit helmet design. Instead, the collection cup is a non-contact device that will be designed using a detailed Computational Fluid Dynamic (CFD) analysis of the ventilation flow environment within the helmet. The CFD code, Fluent, provides modeling of the various gas species (CO2, water vapor, and oxygen (O2)) as they pass through a helmet. This same model will be used to numerically evaluate several different collection cup designs for this same CO2 segregation effort. A new test rig will be built to test the results of the CFD analyses and validate the collection cup designs. This paper outlines the initial results and future plans of this work.

Filburn, Tom↗

Performance and test section flow characteristics of the National Full-Scale Aerodynamics Complex 40- by 80-foot wind tunnel

Results from the performance and test section flow calibration of the 40- by 80-Foot Wind Tunnel are presented. A flow calibration test was conducted in May and June 1987. The goal of the flow calibration test was to determine detailed spatial variations in the 40- by 80-ft test section flow quality throughout the tunnel operational envelope. Data were collected for test section speeds up to 300 knots and for air exchange rates of 0, 5, and 10 percent. The tunnel performance was also calibrated during the detailed mapping of the test section flow field. Experimental results presented indicate that the flow quality in the test section, with the exception of temperature, is relatively insensitive to the level of dynamic pressure and the air exchange rate. The dynamic pressure variation in the test section is within + or - 0.5 deg at all test section velocities. Cross-stream temperature gradients in the test section caused by the air exchange system were documented, and a correction method was established. Streamwise static pressure variation on the centerline is about 1 percent of test section dynamic pressure over 30 ft of the test section length.

Zell, Peter T.↗

Urine collection device

A urine collection device for females is described. It is comprised of a collection element defining a urine collection chamber and an inlet opening into the chamber and is adapted to be disposed in surrounding relation to the urethral opening of the user. A drainage conduit is connected to the collection element in communication with the chamber whereby the chamber and conduit together comprise a urine flow pathway for carrying urine generally away from the inlet. A first body of wicking material is mounted adjacent the collection element and extends at least partially into the flow pathway. The device preferably also comprise a vaginal insert element including a seal portion for preventing the entry of urine into the vagina.

Michaud, R. B.↗

Dissolved Organic Carbon 14C in Southern Nevada Groundwater and Implications for Groundwater Travel Times

Dissolved inorganic carbon (DIC) carbon-14 ( 14 C) ages must be corrected for complex chemical and physical reactions and processes that change the amount of 14 C in groundwater as it flows from recharge to downgradient areas. Because of these reactions, DIC 14 C can produce unrealistically old ages and long groundwater travel times that may, or may not, agree with travel times estimated by other methods. Dissolved organic carbon (DOC) 14 C ages are often younger than DIC 14 C ages because there are few chemical reactions or physical processes that change the amount of DOC 14 C in groundwater. However, there are several issues that create uncertainty in DOC 14 C groundwater ages including limited knowledge of the initial (A 0 ) DOC 14 C in groundwater recharge and potential changes in DOC composition as water moves through an aquifer. This study examines these issues by quantifying A 0 DOC 14 C in recharge areas of southern Nevada groundwater flow systems and by evaluating changes in DOC composition as water flows from recharge areas to downgradient areas. The effect of these processes on DOC 14 C groundwater ages is evaluated and DOC and DIC 14 C ages are then compared along several southern Nevada groundwater flow paths. Twenty-seven groundwater samples were collected from springs and wells in southern Nevada in upgradient, midgradient, and downgradient locations. DOC 14 C for upgradient samples ranged from 96 to 120 percent modern carbon (pmc) with an average of 106 pmc, verifying modern DOC 14 C ages in recharge areas, which decreases uncertainty in DOC 14 C A 0 values, groundwater ages, and travel times. The HPLC spectra of groundwater along a flow path in the Spring Mountains show the same general pattern indicating that the DOC compound composition does not change along this flow path. Although DOC concentration decreases from recharge-area to downgradient groundwater, the organic compounds are similar, indicating that DOC 14 C is unaffected by other processes such as microbial degradation. A small amount of organic carbon was leached from crushed volcanic and carbonate aquifer outcrop rock in rock-leaching experiments. The leached DOC was high in 14 C (75 pmc carbonate rocks, 91 pmc volcanic) suggesting that the leached DOC likely came from microbes in the rock samples. The small amount of DOC and high 14 C indicates that the amount of old organic carbon in these rocks is low so there should be minimal impact on groundwater DOC 14 C ages. Based on the results from this study, DOC 14 C ages do not require additional corrections. Several correction models were applied to DIC 14 C ages to correct for water-rock reactions along two carbonate and two volcanic flow paths and the corresponding travel times were compare to DOC 14 C travel times. The DOC 14 C travel times were hundreds to thousands of years shorter than uncorrected and corrected DIC 14 C travel times except for the upper section of one carbonate flow path. DOC 14 C travel times ranged from 400 to 5,400 years as compared to DIC 14 C that ranged from modern to 20,900 years. The DIC 14 C ages are greatly influenced by carbonate mineral and gas reactions and other processes such as matrix diffusion, isotope exchange, or adsorption, which are not always adequately accounted for in DIC 14 C groundwater age correction models.

54 ENVIRONMENTAL SCIENCES↗

NNSS Soils Monitoring: Plutonium Valley (CAU 366) FY2013 and FY2014

The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil transport from the Plutonium Valley Contamination Area (CA) as a result of wind transport and storm runoff in support of Nevada Nuclear Security Administration (NNSA) efforts to complete regulatory closure of the contamination areas. The DRI work is intended to confirm the likely mechanism(s) of transport and determine the meteorological conditions that might cause movement of contaminated soils. Emphasis is given to collecting sediment transported by channelized storm runoff at the Plutonium Valley investigation sites. These data will inform closure plans that are being developed, which will facilitate appropriate closure design and postclosure monitoring. Desert Research Institute installed two meteorological monitoring stations south (station number 1) and north (station number 2) of the Plutonium Valley CA and a runoff sediment sampling station within the CA in 2011. Temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and airborne particulate concentration are collected at both meteorological stations. The maximum, minimum, and average or total (as appropriate) for each of these parameters is recorded for each 10-minute interval. The sediment sampling station includes an automatically activated ISCO sampling pump with collection bottles for suspended sediment, which is activated when sufficient flow is present in the channel, and passive traps for bedload material that is transported down the channel during runoff events. This report presents data collected from these stations during FY2013 and FY2014.

54 ENVIRONMENTAL SCIENCES↗

NNSS Soils Monitoring: Plutonium Valley (CAU 366) FY2015

Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil transport from the Plutonium Valley Contamination Area (CA) as a result of wind transport and storm runoff in support of National Nuclear Security Administration (NNSA) efforts to complete regulatory closure of the contamination areas. The DRI work is intended to confirm the likely mechanism(s) of transport and determine the meteorological conditions that might cause movement of contaminated soils. The emphasis of the work is on collecting sediment transported by channelized storm runoff at the Plutonium Valley investigation sites. These data will inform closure plans that are being developed, which will facilitate the appropriate closure design and post-closure monitoring. In 2011, DRI installed two meteorological monitoring stations south (station #1) and north (station #2) of the Plutonium Valley CA and a runoff sediment sampling station within the CA. Temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and airborne particulate concentration are collected at both meteorological stations. The maximum, minimum, and average or total (as appropriate) for each of these parameters are recorded for each 10-minute interval. The sediment sampling station includes an automatically activated ISCO sampling pump with collection bottles for suspended sediment, which is activated when sufficient flow is present in the channel, and passive traps for bedload material that is transported down the channel during runoff events. This report presents data collected from these stations during fiscal year (FY) 2015.

54 ENVIRONMENTAL SCIENCES↗