Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Energy Proportionality and Performance in Data Parallel Computing Clusters

Energy consumption in datacenters has recently become a major concern due to the rising operational costs andscalability issues. Recent solutions to this problem propose the principle of energy proportionality, i.e., the amount of energy consumedby the server nodes must be proportional to the amount of work performed. For data parallelism and fault tolerancepurposes, most common file systems used in MapReduce-type clusters maintain a set of replicas for each data block. A coveringset is a group of nodes that together contain at least one replica of the data blocks needed for performing computing tasks. In thiswork, we develop and analyze algorithms to maintain energy proportionality by discovering a covering set that minimizesenergy consumption while placing the remaining nodes in lowpower standby mode. Our algorithms can also discover coveringsets in heterogeneous computing environments. In order to allow more data parallelism, we generalize our algorithms so that itcan discover k-covering sets, i.e., a set of nodes that contain at least k replicas of the data blocks. Our experimental results showthat we can achieve substantial energy saving without significant performance loss in diverse cluster configurations and workingenvironments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal control structure and garment

A flexible thermally conductive structure. The structure generally includes a plurality of thermally conductive yarns, at least some of which are at least partially disposed adjacent to an elastomeric material. Typically, at least a portion of the plurality of thermally conductive yarns is configured as a sheet. The yarns may be constructed from graphite, metal, or similar materials. The elastomeric material may be formed from urethane or silicone foam that is at least partially collapsed, or from a similar material. A thermal management garment is provided, the garment incorporating a flexible thermally conductive structure.

36 MATERIALS SCIENCE↗

System and method for managing electrical components for energy usage

A system for managing performance of one or more electrical components in real-time includes one or more sensors to provide working conditions of one or more energy consuming devices. The system further includes one or more actuators coupled to and configured to control the one or more energy consuming devices. Additionally, the system includes a computing device in electrical communication with the one or more sensors and the one or more actuators. The system also includes a database capable of retaining an instruction program for the computing device. The computing device includes a processor that is configured to receive data from the one or more sensors, analyze data from the one or more sensors, and execute the instruction program received from the database in order to optimize operation of the one or more energy consuming devices based on one or more criteria.

Chen, Jie↗

Hybrid Fuel Cell Systems for Heavy-Duty Trucks: Configuration, Heat Rejection, and Performance

Low-temperature polymer electrolyte membrane fuel cell systems can achieve higher efficiency than diesel engines, but heat rejection remains a major challenge in class-8 heavy-duty fuel cell trucks. For the same rated power, the radiator heat load is greater than that in a diesel engine, while the allowable operating temperatures are lower. This work proposes and evaluates 400 kWe fuel cell–battery hybrid (FCH) platforms and operating strategies that manage heat rejection without enlarging the radiator frontal area. Three FCH platforms are identified, each varying in fuel cell system (FCS) rated power, battery energy storage system (ESS) capacity, and maximum stack coolant exit temperature (T h1 ). All three satisfy key system and vehicle requirements, including 175 kWe FCS power at top sustained speed, 400 kWe FCH power on a 6% grade climb, a target stack power density (PD) of 750 mW e /cm 2 , and heat rejection constraints. The first FCH has the smallest FCS, the largest ESS, and a T h1 of 90 °C. The second achieves the highest PD of 840 mW e /cm 2 at a T h1 of 95 °C. The third has the largest FCS, the smallest ESS, and a T h1 of 102 °C. At a Th1 of 115 °C, the platform can be configured as a stand-alone 400 kWe(net) FCS without hybridization, but the achievable PD drops to 460 mW e /cm 2 .

25 ENERGY STORAGE↗

Instantiation of the Damara Tern Platform for Advanced Materials and Manufacturing Technologies (AMMT) Program Collaborative Data Management

This work package focused on deploying an instance of the Damara Tern platform to support AMMT collaborative research activities. The objectives were to provide selected AMMT collaborators with access to a shared environment for capturing operations, trackables, and associated metadata, and to implement data entry functionalities that reflect site-specific procedures. Key activities included creating configurable, schema-driven entry forms and validating the data collection process. The report details the deployment process, the platform infrastructure, and the implemented data entry workflows, providing a reference for end users and establishing a foundation for future production-scale deployments.

36 MATERIALS SCIENCE↗

A Hands-On Curriculum for Training in HPC Cluster Deployment and Management

This paper presents the design, methodology, and outcomes of the High-Performance Computing Technologies (HPCT) course, a hands-on training program focused on the system-side of HPC cluster deployment and administration. Delivered as part of the Master in High Performance Computing (MHPC) program, the course introduces students to key concepts in cluster configuration, including networking, software stack provisioning, job scheduling, and monitoring. Initially taught in person, the course was transitioned to an online format during the COVID-19 pandemic. This shift led to the development of openly available instructional material and a flipped-classroom approach that continues to support both in-person and hybrid delivery. All course materials are publicly available at www.hpc.temple.edu/mhpc/hpc-technology/index.html. By documenting the structure, infrastructure, and evolution of HPCT, this paper offers a model for accessible HPC system training that supports workforce development in computational science.

Posada Correa, Fernando [ORNL] (ORCID:000000022565↗

Independent Review of Groundwater Remediation Strategy for Hexavalent Chromium and RDX Groundwater Plumes at Los Alamos National Laboratory (Rev. 1)

Site operations at the Los Alamos National Laboratory (LANL) resulted in the release of oxidized chromium, Cr(VI), into Sandia Canyon from cooling tower effluent from 1956 until 1972. The chromium traveled with the surface water approximately 3 miles downstream before migrating below ground surface. Chromium concentrations exceed 50 μg/L in the upper portion of the aquifer. Another LANL groundwater plume of concern is associated with RDX (Royal Demolition Explosives, 1,3,5-trinitro-1,3,5-triazine). Between 1951 and 1996, RDX was released to the mesa-top facilities' process water outfall, adjacent and underlying soils, and alluvial sediments, along with surface water in Cañon de Valle. Between 2000 and 2010, two remedial actions were deployed, removing much of the near-surface RDX, however, recharge due to precipitation has transported RDX into the perched-intermediate zone and into the regional aquifer. The report documents an independent technical review by scientists from the Department of Energy (DOE) Network of National Laboratories for Environmental Management and Stewardship (NNLEMS) to provide recommendations for potential near term actions to address and optimize remediation for both the Cr(VI) and RDX plumes. The proposed near-term remedial actions include design of pump and treat systems for Cr(VI) and monitoring and study for natural attenuation for RDX. The review assesses existing data, conceptual and numerical modeling, and it recommends a technical integration process to support identifying and implementing strategic, effective and efficient remedies. The DOE Environmental Management Los Alamos Field Office (EM-LA) and their cleanup contractor Newport News Nuclear-BWTX, LLC Los Alamos (N3B) provided the information required for the review. Interviews were also conducted with regulators to obtain the full spectrum of technical, regulatory and scientific perspectives. The independent review team was impressed by the capabilities, experiences, innovativeness, and insightfulness of the technical representatives from both the regulator, the New Mexico Environment Department (NMED) and N3B. Incorporation of vadose zone flow pathways in the conceptual site model (CSM) and configuring the numerical modeling for the site was generally state-of-the-practice (or better). This could be considered state-of-the-art by addressing uncertainties related to spatial extent of hydraulic windows. The reviews from the regulators were thorough and often provided useful concepts for consideration and future/study resolutions. The overarching consensus recommendation of independent review team is that the LANL groundwater plumes should be addressed in context of the emerging "management of complex sites" paradigm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Risk-based monitoring designs for detecting CO 2 leakage through abandoned wellbores: An application of NRAP’s WLAT and DREAM tools

We report that one suggested approach to managing the risk of geologic CO 2 storage projects is to perform risk-based subsurface monitoring targeting early leak detection. The challenge in risk-based monitoring is that leakage impacts are expected to be small in comparison with the footprint of the stored CO 2 plume and could be at depths ranging from the depth of storage (often ~1 km bgs) up to surficial aquifers. Addressing this challenge requires a multidisciplinary effort capable of characterizing potential subsurface leakage in terms of likelihood, location, magnitude, impacts to overlying aquifers, and uncertainty as well as innovative monitoring technology design and implementation. The National Risk Assessment Partnership (NRAP) was established to develop related risk assessment tools to provide guidance on such assessments. Here we demonstrate the application workflow of two of the NRAP computational tools, WLAT (Wellbore Leakage Analysis Tool) and DREAM (Designs for Risk Evaluation and Management), to a hypothetical CO 2 storage site based on a study area in the Midwestern United States. This workflow shows how CO 2 leakage may be estimated, evaluated, and monitored in terms of risk. Results provide guidance on monitoring configurations and technologies which minimize the time to leak detection, maximize the probability detection, and provide cost considerations.

54 ENVIRONMENTAL SCIENCES↗

SU-D-BRD-03: Improving Plan Quality with Automation of Treatment Plan Checks

Purpose: To evaluate the effectiveness of an automated plan check tool to improve first-time plan quality as well as standardize and document performance of physics plan checks. Methods: The Plan Checker Tool (PCT) uses the Eclipse Scripting API to check and compare data from the treatment planning system (TPS) and treatment management system (TMS). PCT was created to improve first-time plan quality, reduce patient delays, increase efficiency of our electronic workflow, and to standardize and partially automate plan checks in the TPS. A framework was developed which can be configured with different reference values and types of checks. One example is the prescribed dose check where PCT flags the user when the planned dose and the prescribed dose disagree. PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user. A PDF report is created and automatically uploaded into the TMS. Prior to and during PCT development, errors caught during plan checks and also patient delays were tracked in order to prioritize which checks should be automated. The most common and significant errors were determined. Results: Nineteen of 33 checklist items were automated with data extracted with the PCT. These include checks for prescription, reference point and machine scheduling errors which are three of the top six causes of patient delays related to physics and dosimetry. Since the clinical roll-out, no delays have been due to errors that are automatically flagged by the PCT. Development continues to automate the remaining checks. Conclusion: With PCT, 57% of the physics plan checklist has been partially or fully automated. Treatment delays have declined since release of the PCT for clinical use. By tracking delays and errors, we have been able to measure the effectiveness of automating checks and are using this information to prioritize future development. This project was supported in part by P01CA059827.

60 APPLIED LIFE SCIENCES↗

Typical hot water draw patterns based on field data

There is significant variation in hot water use and draw patterns among households. This report describes typical hot water use patterns in single-family residences in North America. We found that daily hot water use is highly variable both among residences and within the same residence. We compared the results of our analysis of the field data to the conditions and draw patterns established in the current U.S. Department of Energy (DOE) test procedure for residential water heaters. The results show a higher number of smaller draws at lower flow rates than used in the test procedure. The data from which the draw patterns were developed were obtained from 12 separate field studies. This report describes the ways in which we managed, cleaned, and analyzed the data and the results of our data analysis. After preparing the data, we used the complete data set to analyze inlet and outlet water temperatures. Then we divided the data into three clusters reflecting house configurations that demonstrated small, medium, or large median daily hot water use. We developed the three clusters partly to reflect efforts of the ASHRAE standard project committee (SPC) 118.2 to revise the test procedure for residential water heaters to incorporate a range of draw patterns. ASHRAE SPC 118.2 has identified the need to separately evaluate at least three, and perhaps as many as five, different water heater capacities. We analyzed the daily hot water use data within each cluster in terms of volume and number of hot water draws. The daily draw patterns in each cluster were characterized using distributions for volume of draws, duration of draws, time since previous draw, and flow rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

As-Run Thermal Analysis for the Utah State University Experiment in the Advanced Test Reactor

The Utah State University (USU) Advanced Test Reactor (ATR) National Scientific User Facility experiment is a materials test consisting of specimens of hafnium aluminide intermetallic and composite. Specimens were contained in sealed, drop-in capsule pairs that were irradiated in the ATR B2 position for up to four reactor cycles (149A, 149B, 150 B and 151A). The experiment configuration was modeled using ABAQUS CAE Version 6.14-2 for construction of the finite element model and ABAQUS Standard to calculate specimen temperatures under as-run irradiation conditions. This ECAR report was formalized as requested by the NSUF project manager (Attachment A). A thermal analysis was performed to determine the irradiation temperatures of each test specimen for up to four irradiation cycles (149A, 149B, 150 B and 151A) that comprised the irradiation campaign. Computed minimum, average and maximum specimen temperatures are given for each of the 132 specimens for an average set of heat rates provided by the physics analysis. In addition, bounding temperatures are given for each specimen using the maximum heat rates from the physics analysis. Specimens in Capsules C 1, D 1 and B 2 experienced the lowest temperatures, followed by those in Capsules B 1, C 2 and D-2, and the highest temperatures were in specimens located in Capsules A-1 and A-2. Temperatures of the specimens for all cycles were between 325.2K and 424.7K. The highest average specimen temperature of 422.9K occurred in the intermetallic rod specimens in Capsule A-1 during Cycle 149B. The highest bounding temperature in the specimens was 424.7K. This information will be used in conjunction with PIE measurements to elucidate the thermophysical mechanisms occurring during, and as a result of, irradiation in the ATR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Wood-to-Fuel Demonstration Project for California's Transportation Sector using Autothermal Pyrolysis (Non-Proprietary Summary Process Hazard Assessment)

Frontline has prioritized personnel safety, equipment preservation, and environmental protection throughout the design process of the autothermal pyrolysis unit. To facilitate a safe design, Frontline completed an informal hazards and operability (HAZOP) study and a formal HAZOP study, and employ management of change procedures. The result of these safety procedures is a plant that will function in a safe manner with a limited and acceptable amount of risk. Frontline took an approach it used in previous projects to execute a preliminary, internally facilitated hazards and operability (HAZOP) study. While this HAZOP study was performed without any subsequent change tracking, it enables a group of well-trained engineers to consider the safety implications of each part of the plant in a thorough and methodical manner. Frontline chose to bring in a pyrolysis consultant (Daren Daugaard of Burning Oak Energy) to participate in the review. Following the preliminary HAZOP and once the detailed design work was nearing completion, Frontline performed a formal HAZOP with a third-party facilitator, Jason Stittleburg of Novetus Engineering. Although the plant is not subject to process safety management (PSM) requirements, this formal HAZOP was performed in accordance with OSHA regulations deemed reasonable for PSM. Finally, after the formal HAZOP was conducted, Frontline maintained a safe system by implementing and following management of change procedures on each substantial change to the process. Frontline has kept a record of each subsequent change made to the formal HAZOP P&IDs. The process hazard assessment process allowed Frontline to find and correct several unacceptable configurations within the plant.

09 BIOMASS FUELS↗

IER-479: Final Design of Low-Temperature TEX Experiments [Slides]

This presentation discusses the final design of low-temperature Thermal Epithermal eXperiments (TEX) experiments. Designed to validate low temperature cross sections and crit safety analyses. The presentation includes discussion on Low-Temp TEX Chamber a Cryostat Chamber capable of cooling between room temp and -40c. Finally, the presentation touches on reactivity via separation where the need to know how the system will behave approaching critical as lifted into annular reflector is analyzed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fermilab s Transition to Token Authentication

Fermilab is the first High Energy Physics institution to transition from X.509 user certificates to authentication tokens in production systems. All of the experiments that Fermilab hosts are now using JSON Web Token (JWT) access tokens in their grid jobs. Many software components have been either updated or created for this transition, and most of the software is available to others as open source. The tokens are defined using the WLCG Common JWT Profile. Token attributes for all the tokens are stored in the Fermilab FERRY system which generates the configuration for the CILogon token issuer. High security-value refresh tokens are stored in Hashicorp Vault configured by htvault-config, and JWT access tokens are requested by the htgettoken client through its integration with HTCondor. The Fermilab job submission system jobsub was redesigned to be a lightweight wrapper around HTCondor. For automated job submissions a managed tokens service was created to reduce duplication of effort and knowledge of how to securely keep tokens active. The existing Fermilab file transfer tool ifdh was updated to work seamlessly with tokens, as well as the Fermilab POMS (Production Operations Management System) which is used to manage automatic job submission and the RCDS (Rapid Code Distribution System) which is used to distribute analysis code via the CernVM FileSystem. The dCache storage system was reconfigured to accept tokens for authentication in place of X.509 proxy certificates. As some services and sites have not yet implemented token support, proxy certificates are still sent with jobs for backwards compatibility but some experiments are beginning to transition to stop using them. There have been some glitches and learning curve issues but in general the system has been performing well and is being improved as operational problems are addressed.

Dykstra, David↗

Local access control system management using domain information updates

Systems and methods are presented for managing physical access to an access-controlled area using a local access control system. In certain embodiments, information that may be used in access control determinations managed by a remote domain controller may be communicated to a local access control system for use in connection with local access control determinations performed by the access control system independent of the domain controller. In some embodiments, such a configuration may allow for access control determinations to be performed when communication with the domain controller is interrupted and/or otherwise limited.

Masters, George W.↗

Local access control system management using domain information updates

Systems and methods are presented for managing physical access to an access-controlled area using a local access control system. In certain embodiments, information that may be used in access control determinations managed by a remote domain controller may be communicated to a local access control system for use in connection with local access control determinations performed by the access control system independent of the domain controller. In some embodiments, such a configuration may allow for access control determinations to be performed when communication with the domain controller is interrupted and/or otherwise limited.

Masters, George W.↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

42 ENGINEERING↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

Lundstrom, Blake Richard↗