Search NASA⌕ Search

SEARCH · Search NASA

Results for “Convolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Comparing Mapper Graphs of Artificial Neuron Activations

The mapper graph is a popular tool from topological data analysis that provides a graphical summary of point cloud data. It has been used to study data from cancer research, sports analytics, neurosciences, and machine learning. In particular, mapper graphs have been used recently to visualize the topology of high-dimensional artificial neural activations from convolutional neural networks and large language models. However, a key question that arises from using mapper graphs across applications is how to compare mapper graphs to study their structural differences. In this paper, we introduce a distance between mapper graphs using tools from optimal transport. We demonstrate the utility of such a distance by studying the topological changes of neural activations across convolutional layers in deep learning, as well as by capturing the loss of structural information for multiscale mapper.

mapper graphs, computational topology, machine lea↗

Accelerating Binarized Neural Networks via Bit-Tensor-Cores in Turing GPUs

Despite foreseeing tremendous speedups over conventional deep neural networks, the performance advantage of binarized neural networks (BNNs) has merely been showcased on general-purpose processors such as CPUs and GPUs. In fact, due to being unable to leverage bit-level-parallelism with a word-based architecture, GPUs have been criticized for extremely low utilization (1%) when executing BNNs. Consequently, the latest tensorcores in NVIDIA Turing GPUs start to experimentally support bit computation. In this work, we look into this brand new bit computation capability and characterize its unique features. We show that the stride of memory access can significantly affect performance delivery and a data-format co-design is highly desired to support the tensorcores for achieving superior performance than existing software solutions without tensorcores. We realize the tensorcore-accelerated BNN design, particularly the major functions for fully-connect and convolution layers — bit matrix multiplication and bit convolution. Evaluations on two NVIDIA Turing GPUs show that, with ResNet-18, our BTC-BNN design can process ImageNet at a rate of 5.6K images per second, 77% faster than state-of-the-art. Our BNN approach is released on https://github.com/pnnl/TCBNN.

Li, Ang↗

Frequency Disturbance Event Detection Based on Synchrophasors and Deep Learning

Power system frequency disturbances are caused by various generation and transmission events including generator trips, load disconnections, line trips, etc. Accurate detections of the events are crucial to bulk power system situation awareness and event investigation. This paper utilizes the recent advances of deep learning to build a convolutional neural network model to detect events in an accurate yet straightforward manner. Herein, the rate of change of frequency and the relative angle shift are converted to images as the inputs of the proposed model. Finally, this paper uses two convolutional neural networks and classifier fusion to achieve the detection result. Compared with the conventional event detection algorithm and the frequency only deep learning model, the proposed model improves the detection accuracy by over 48%. As a promising tool for bulk power system situation awareness, the proposed model requires a short decision time, which is suitable for practical scenarios.

42 ENGINEERING↗

Data-Efficient Dimensionality Reduction and Surrogate Modeling of High-Dimensional Stress Fields

Tensor datatypes representing field variables like stress, displacement, velocity, etc., have increasingly become a common occurrence in data-driven modeling and analysis of simulations. Numerous methods [such as convolutional neural networks (CNNs)] exist to address the meta-modeling of field data from simulations. As the complexity of the simulation increases, so does the cost of acquisition, leading to limited data scenarios. Modeling of tensor datatypes under limited data scenarios remains a hindrance for engineering applications. Here, in this article, we introduce a direct image-to-image modeling framework of convolutional autoencoders enhanced by information bottleneck loss function to tackle the tensor data types with limited data. The information bottleneck method penalizes the nuisance information in the latent space while maximizing relevant information making it robust for limited data scenarios. The entire neural network framework is further combined with robust hyperparameter optimization. We perform numerical studies to compare the predictive performance of the proposed method with a dimensionality reduction-based surrogate modeling framework on a representative linear elastic ellipsoidal void problem with uniaxial loading. The data structure focuses on the low-data regime (fewer than 100 data points) and includes the parameterized geometry of the ellipsoidal void as the input and the predicted stress field as the output. The results of the numerical studies show that the information bottleneck approach yields improved overall accuracy and more precise prediction of the extremes of the stress field. Additionally, an in-depth analysis is carried out to elucidate the information compression behavior of the proposed framework.

artificial intelligence↗

In silico simulations of tunneling barrier measurements for molecular orbital-mediated junctions: A molecular orbital theory approach to scanning tunneling microscopy

A new simulator for scanning tunneling microscopy (STM) is presented based on the linear combination of atomic orbitals molecular orbital (LCAO-MO) approximation for the effective tunneling Hamiltonian, which leads to the convolution integral when applied to the tip interaction with the sample. This approach intrinsically includes the structure of the STM tip. Through this mechanical emulation and the tip-inclusive convolution model, dI/dz images for molecular orbitals (which are closely associated with apparent barrier height, ϕ{sub ap}) are reported for the first time. For molecular adsorbates whose experimental topographic images correspond well to isolated-molecule quantum chemistry calculations, the simulator makes accurate predictions, as illustrated by various cases. Distortions in these images due to the tip are shown to be in accord with those observed experimentally and predicted by other ab initio considerations of tip structure. Simulations of the tunneling current dI/dz images are in strong agreement with experiment. The theoretical framework provides a solid foundation which may be applied to LCAO cluster models of adsorbate–substrate systems, and is extendable to emulate several aspects of functional STM operation.

42 ENGINEERING↗

Image transformers for classifying acute lymphoblastic leukemia

Cancer is the leading cause of death by disease in American children. Each year, nearly 16,000 children in the United States and over 300,000 children globally are diagnosed with cancer. Leukemia is a form of blood cancer that originates in the bone marrow and accounts for one-third of pediatric cancers. This disease occurs when the bone marrow contains 20% or more immature white blood cell blasts. Acute lymphoblastic leukemia is the most prevalent leukemia type found in children, with half of all annual cases in the U.S. diagnosed for subjects under 20 years of age. To diagnose acute lymphoblastic leukemia, pathologists often conduct a morphological bone marrow assessment. This assessment determines whether the immature white blood cell blasts in bone marrow display the correct morphological characteristics, such as size and appearance of nuclei. Pathologists also use immunophenotyping via multi-channel flow cytometry to test whether certain antigens are present on the surface of blast cells; the antigens are used to identify the cell lineage of acute lymphoblastic leukemia. These manual processes require well-trained personnel and medical professionals, thus being costly in time and expenses. Computerized decision support via machine learning can accelerate the diagnosis process and reduce the cost. Training a reliable classification model to distinguish between mature and immature white blood cells is essential to the decision support system. Here, we adopted the Vision Transformer model to classify white blood cells. The Vision Transformer achieved superb classification performance compared to state-of-the-art convolutional neural networks while requiring less computational resources for training. Additionally, the latent self-attention architecture provided attention maps for a given image, providing clues as to which portion(s) of the image were significant in decision-making. We applied the Vision Transformer model and a convolutional neural network model to an acute lymphoblastic leukemia classification dataset of 12,528 samples and achieved accuracies of 88.4% and 86.2%.

Cho, Priscilla↗

Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations

Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S values for monoenergetic sources (electrons and photons) and different radionuclides ({sup 90}Y, {sup 131}I, and {sup 188}Re) were calculated. Simulations were performed in soft tissue. Three general-purpose MC codes were employed for simulating radiation transport: MCNP4C, EGSnrc, and GEANT4. The data published by the MIRD Committee in Pamphlet No. 17, obtained with the EGS4 MC code, were also included in the comparisons. The impact of the differences (in terms of voxel S values) among the MC codes was also studied by convolution calculations of the absorbed dose in a volume of interest. For uniform activity distribution of a given radionuclide, dose calculations were performed on spherical and elliptical volumes, varying the mass from 1 to 500 g. For simulations with monochromatic sources, differences for self-irradiation voxel S values were mostly confined within 10% for both photons and electrons, but with electron energy less than 500 keV, the voxel S values referred to the first neighbor voxels showed large differences (up to 130%, with respect to EGSnrc) among the updated MC codes. For radionuclide simulations, noticeable differences arose in voxel S values, especially in the bremsstrahlung tails, or when a high contribution from electrons with energy of less than 500 keV is involved. In particular, for {sup 90}Y the updated codes showed a remarkable divergence in the bremsstrahlung region (up to about 90% in terms of voxel S values) with respect to the EGS4 code. Further, variations were observed up to about 30%, for small source-target voxel distances, when low-energy electrons cover an important part of the emission spectrum of the radionuclide (in our case, for {sup 131}I). For {sup 90}Y and {sup 188}Re, the differences among the various codes have a negligible impact (within few percents) on convolution calculations of the absorbed dose; thus either one of the MC programs is suitable to produce voxel S values for radionuclide targeted therapy dosimetry. However, if a low-energy beta-emitting radionuclide is considered, these differences can affect also dose depositions at small source-target voxel distances, leading to more conspicuous variations (about 9% for {sup 131}I) when calculating the absorbed dose in the volume of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric characterization of the iBEAM evo carbon fiber couch for radiotherapy

Purpose: This study characterizes the dosimetric properties of the iBEAM evo carbon fiber couch manufactured by Medical Intelligence and examines the accuracy of the CMS XiO and Nucletron Oncentra Masterplan (OMP) treatment planning systems for calculating beam attenuation due to the presence of the couch. Methods: To assess the homogeneity of the couch, it was CT scanned at isocentric height and a number of signal intensity profiles were generated and analyzed. To simplify experimental procedures, surface dose and central axis depth dose measurements were performed in a solid water slab phantom using Gafchromic film for 6 and 10 MV photon beams at gantry angles of 0 deg. (normal incidence), 30 deg., and 60 deg. with an inverted iBEAM couch placed on top of the phantom. Attenuation measurements were performed in a cylindrical solid water phantom with an ionization chamber positioned at the isocenter. Measurements were taken for gantry angles from 0 deg. to 90 deg. in 10 deg. increments for both 6 and 10 MV photon beams. This setup was replicated in the XiO and OMP treatment planning systems. Dose was calculated using the pencil beam, collapsed cone, convolution, and superposition algorithms. Results: The CT scan of the couch showed that it was uniformly constructed. Surface dose increased by (510{+-}30)% for a 6 MV beam and (600{+-}20)% for a 10 MV beam passing through the couch at normal incidence. Obliquely incident beams resulted in a higher surface dose compared to normally incident beams for both open fields and fields with the couch present. Depth dose curves showed that the presence of the couch resulted in an increase in dose in the build up region. For 6 and 10 MV beams incident at 60 deg., nearly all skin sparing was lost. Attenuation measurements derived using the ionization chamber varied from 2.7% (0 deg.) to a maximum of 4.6% (50 deg.) for a 6 MV beam and from 1.9% (0 deg.) to a maximum of 4.0% (50 deg.) for a 10 MV beam. The pencil beam and convolution algorithms failed to accurately calculate couch attenuation. The collapsed cone and superposition algorithms calculated attenuation within an absolute error of {+-}1.2% for 6 MV and {+-}0.8% for 10 MV for gantry angles from 0 deg. to 40 deg. Some differences in attenuation were observed dependent on how the couch was contoured. Conclusions: These results demonstrate that the presence of the iBEAM evo carbon fiber couch increases the surface dose and dose in the build up region. The inclusion of the couch in the planning scan is limited by the field of view employed and the couch height at the time of CT scanning.

60 APPLIED LIFE SCIENCES↗

Portal dosimetry for VMAT using integrated images obtained during treatment

Purpose: Portal dosimetry provides an accurate and convenient means of verifying dose delivered to the patient. A simple method for carrying out portal dosimetry for volumetric modulated arc therapy (VMAT) is described, together with phantom measurements demonstrating the validity of the approach. Methods: Portal images were predicted by projecting dose in the isocentric plane through to the portal image plane, with exponential attenuation and convolution with a double-Gaussian scatter function. Appropriate parameters for the projection were selected by fitting the calculation model to portal images measured on an iViewGT portal imager (Elekta AB, Stockholm, Sweden) for a variety of phantom thicknesses and field sizes. This model was then used to predict the portal image resulting from each control point of a VMAT arc. Finally, all these control point images were summed to predict the overall integrated portal image for the whole arc. The calculated and measured integrated portal images were compared for three lung and three esophagus plans delivered to a thorax phantom, and three prostate plans delivered to a homogeneous phantom, using a gamma index for 3% and 3 mm. A 0.6 cm{sup 3} ionization chamber was used to verify the planned isocentric dose. The sensitivity of this method to errors in monitor units, field shaping, gantry angle, and phantom position was also evaluated by means of computer simulations. Results: The calculation model for portal dose prediction was able to accurately compute the portal images due to simple square fields delivered to solid water phantoms. The integrated images of VMAT treatments delivered to phantoms were also correctly predicted by the method. The proportion of the images with a gamma index of less than unity was 93.7% ± 3.0% (1SD) and the difference between isocenter dose calculated by the planning system and measured by the ionization chamber was 0.8% ± 1.0%. The method was highly sensitive to errors in monitor units and field shape, but less sensitive to errors in gantry angle or phantom position. Conclusions: This method of predicting integrated portal images provides a convenient means of verifying dose delivered using VMAT, with minimal image acquisition and data processing requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of cardiac output from dynamic pulmonary circulation time CT

Purpose: To introduce a method of estimating cardiac output from the dynamic pulmonary circulation time CT that is primarily used to determine the optimal time window of CT pulmonary angiography (CTPA). Methods: Dynamic pulmonary circulation time CT series, acquired for eight patients, were retrospectively analyzed. The dynamic CT series was acquired, prior to the main CTPA, in cine mode (1 frame/s) for a single slice at the level of the main pulmonary artery covering the cross sections of ascending aorta (AA) and descending aorta (DA) during the infusion of iodinated contrast. The time series of contrast changes obtained for DA, which is the downstream of AA, was assumed to be related to the time series for AA by the convolution with a delay function. The delay time constant in the delay function, representing the average time interval between the cross sections of AA and DA, was determined by least square error fitting between the convoluted AA time series and the DA time series. The cardiac output was then calculated by dividing the volume of the aortic arch between the cross sections of AA and DA (estimated from the single slice CT image) by the average time interval, and multiplying the result by a correction factor. Results: The mean cardiac output value for the six patients was 5.11 (l/min) (with a standard deviation of 1.57 l/min), which is in good agreement with the literature value; the data for the other two patients were too noisy for processing. Conclusions: The dynamic single-slice pulmonary circulation time CT series also can be used to estimate cardiac output.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other methods of dose calculation usually applied in the clinic.

60 APPLIED LIFE SCIENCES↗

SU-E-T-456: Impact of Dose Calculation Algorithms On Biologically Optimized VMAT Plans for Esophageal Cancer

Purpose: To evaluate the impact of dose calculation algorithm on the dose distribution of biologically optimized Volumatric Modulated Arc Therapy (VMAT) plans for Esophgeal cancer. Methods: Eighteen retrospectively treated patients with carcinoma esophagus were studied. VMAT plans were optimized using biological objectives in Monaco (5.0) TPS for 6MV photon beam (Elekta Infinity). These plans were calculated for final dose using Monte Carlo (MC), Collapsed Cone Convolution (CCC) & Pencil Beam Convolution (PBC) algorithms from Monaco and Oncentra Masterplan TPS. A dose grid of 2mm was used for all algorithms and 1% per plan uncertainty maintained for MC calculation. MC based calculations were considered as the reference for CCC & PBC. Dose volume histogram (DVH) indices (D95, D98, D50 etc) of Target (PTV) and critical structures were compared to study the impact of all three algorithms. Results: Beam models were consistent with measured data. The mean difference observed in reference with MC calculation for D98, D95, D50 & D2 of PTV were 0.37%, −0.21%, 1.51% & 1.18% respectively for CCC and 3.28%, 2.75%, 3.61% & 3.08% for PBC. Heart D25 mean difference was 4.94% & 11.21% for CCC and PBC respectively. Lung Dmean mean difference was 1.5% (CCC) and 4.1% (PBC). Spinal cord D2 mean difference was 2.35% (CCC) and 3.98% (PBC). Similar differences were observed for liver and kidneys. The overall mean difference found for target and critical structures was 0.71±1.52%, 2.71±3.10% for CCC and 3.18±1.55%, 6.61±5.1% for PBC respectively. Conclusion: We observed a significant overestimate of dose distribution by CCC and PBC as compared to MC. The dose prediction of CCC is closer (<3%) to MC than that of PBC. This can be attributed to poor performance of CCC and PBC in inhomogeneous regions around esophagus. CCC can be considered as an alternate in the absence of MC algorithm.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-15: Physical Aspects and Clinical Applications of Post-Treatment Yttrium-90 PET-Based Dosimetry

Purpose: The accuracy of PET-based post-treatment dosimetry of yttrium-90 microspheres has been improving over the past decade and is now at a stage, permitting volumetric dose-outcome studies. We outline the recent advances and identify the physical limitations to the accuracy of the dose calculations. Methods: Convolution of the measured PET activity density distribution with a pre-calculated voxel-dose-kernel (VDK) is the most widely used method for dose reconstruction. Therefore, accurate knowledge of the beta+ branching ratio as well as the micro-dosimetric characteristics of electron interactions within the microsphere is essential for the computation of the dose kernel. We implement a model of the microspheres used in our clinic to calculate the modified electron energy spectrum at the microsphere’s surface and to determine the impact of self-shielding on the dose reconstruction. The three-dimensional dose distributions obtained for 10 patients treated with radio-embolization with yttrium-90 microspheres are evaluated and various DVH markers are investigated for correlation with outcome. Results: The methods for reducing the overall computation uncertainty are systematically outlined in this presentation. Since the latest experimental data on yttrium-90 beta+ branching ratio has a relative uncertainty of 1.5%, all contributing factors derived from Monte Carlo simulations must be brought to a sub 1% level. The self-shielding within the microspheres is found to be responsible for up to 6% reduction of the reconstructed dose in low-gradient regions and must be taken into account. The contribution of trace amounts of other beta+ emitters introduced during the manufacturing process is also discussed. Conclusion: The accelerating pace of clinical adoption of PET-based post-treatment dosimetry is mainly due to advances in both quantitative PET imaging and physical models of dose deposition. We show that the overall physical dose uncertainty in the convolution step can be further reduced, thus making ongoing multi-institutional dose-outcome studies even more reliable.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-06: Dose Calculation in Curved Space

Purpose: Microbeam Radiation Therapy is a preclinical method in radiation oncology that modulates radiation fields on a micrometre scale. Dose calculation is challenging due to arising dose gradients and therapeutically important dose ranges. Monte Carlo (MC) simulations, often used as gold standard, are computationally expensive and hence too slow for the optimisation of treatment parameters in future clinical applications. On the other hand, conventional kernel based dose calculation leads to inaccurate results close to material interfaces. The purpose of this work is to overcome these inaccuracies while keeping computation times low. Methods: A point kernel superposition algorithm is modified to account for tissue inhomogeneities. Instead of conventional ray tracing approaches, methods from differential geometry are applied and the space around the primary photon interaction is locally warped. The performance of this approach is compared to MC simulations and a simple convolution algorithm (CA) for two different phantoms and photon spectra. Results: While peak doses of all dose calculation methods agreed within less than 4% deviations, the proposed approach surpassed a simple convolution algorithm in accuracy by a factor of up to 3 in the scatter dose. In a treatment geometry similar to possible future clinical situations differences between Monte Carlo and the differential geometry algorithm were less than 3%. At the same time the calculation time did not exceed 15 minutes. Conclusion: With the developed method it was possible to improve the dose calculation based on the CA method with respect to accuracy especially at sharp tissue boundaries. While the calculation is more extensive than for the CA method and depends on field size, the typical calculation time for a 20×20 mm{sup 2} field on a 3.4 GHz and 8 GByte RAM processor remained below 15 minutes. Parallelisation and optimisation of the algorithm could lead to further significant calculation time reductions.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-05: Machine-Learning Based Segmentation of Organs at Risks for Head and Neck Radiotherapy Planning

Purpose: Accurate and efficient delineation of tumor target and organs-at-risks is essential for the success of radiotherapy. In reality, despite of decades of intense research efforts, auto-segmentation has not yet become clinical practice. In this study, we present, for the first time, a deep learning-based classification algorithm for autonomous segmentation in head and neck (HaN) treatment planning. Methods: Fifteen HN datasets of CT, MR and PET images with manual annotation of organs-at-risk (OARs) including spinal cord, brainstem, optic nerves, chiasm, eyes, mandible, tongue, parotid glands were collected and saved in a library of plans. We also have ten super-resolution MR images of the tongue area, where the genioglossus and inferior longitudinalis tongue muscles are defined as organs of interest. We applied the concepts of random forest- and deep learning-based object classification for automated image annotation with the aim of using machine learning to facilitate head and neck radiotherapy planning process. In this new paradigm of segmentation, random forests were used for landmark-assisted segmentation of super-resolution MR images. Alternatively to auto-segmentation with random forest-based landmark detection, deep convolutional neural networks were developed for voxel-wise segmentation of OARs in single and multi-modal images. The network consisted of three pairs of convolution and pooing layer, one RuLU layer and a softmax layer. Results: We present a comprehensive study on using machine learning concepts for auto-segmentation of OARs and tongue muscles for the HaN radiotherapy planning. An accuracy of 81.8% in terms of Dice coefficient was achieved for segmentation of genioglossus and inferior longitudinalis tongue muscles. Preliminary results of OARs regimentation also indicate that deep-learning afforded an unprecedented opportunities to improve the accuracy and robustness of radiotherapy planning. Conclusion: A novel machine learning framework has been developed for image annotation and structure segmentation. Our results indicate the great potential of deep learning in radiotherapy treatment planning.

60 APPLIED LIFE SCIENCES↗

Neuromorphic computing for temporal scientific data classification

In this work, we apply a spiking neural network model and an associated memristive neuromorphic implementation to an application in classifying temporal scientific data. We demonstrate that the spiking neural network model achieves comparable results to a previously reported convolutional neural network model, with significantly fewer neurons and synapses required.

Schuman, Catherine↗

A sequential DNN based Baseline Energy Prediction Framework with Long term Error Mitigation

In this paper,we aim to present a novel sequential framework containing two deep network architectures for baseline energy prediction, applied to a simulated commercial building dataset. We have observed that this sequential framework helps to improve long term prediction accuracy, there by mitigating prediction error accumulation over time. The proposed framework utilizes convolution layers to extract features from the input data space without changing spatial relations between variables. These features are memorized by tensor train based gated recurrent units for an accurate long-term prediction. Although, architecture comprising the amalgamation of convolution layers and memory cell have shown promising results in domains such as social media analysis, language modeling, video frame prediction and image recognition, this paper extends its scope to the context of energy applications. Furthermore, the addition of tensor train based gated recurrent units is motivated by the necessity of computational time reduction during the training process, there by making this framework more suitable for future in-field deployment. Lastly, results show the current framework outperforms other existing machine learning based methods, in both short-term and long-term prediction categories.

Chakraborty, Indrasis↗

Effects of Radiation-Induced Defects on Corrosion

The next generation of nuclear reactors will expose materials to conditions that, in some cases, are even more extreme than those in current fission reactors, inevitably leading to new materials science challenges. Radiation-induced damage and corrosion are two key phenomena that must be understood both independently and synergistically, but their interactions are often convoluted. In the light water reactor community, a tremendous amount of work has been done to illuminate irradiation-corrosion effects, and similar efforts are under way for heavy liquid metal and molten salt environments. While certain effects, such as radiolysis and irradiation-assisted stress corrosion cracking, are reasonably well established, the basic science of how irradiation-induced defects in the base material and the corrosion layer influence the corrosion process still presents many unanswered questions. In this review, we summarize the work that has been done to understand these coupled extremes, highlight the complex nature of this problem, and identify key knowledge gaps.

36 MATERIALS SCIENCE↗