Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cybersecurity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Hands-On, Heads-Up: Blending Cyber T&E with Data Science-Driven Training in Jupyter Notebooks

In an era of increasingly sophisticated threats to critical infrastructure, cybersecurity professionals must be more than just aware; they must be immersed, agile, and equipped to operate in environments where failure is not an option. Nowhere is this truer than in the nuclear sector, where cyber-physical systems, regulatory scrutiny, and insider threat potential demand a new generation of hands-on, technically fluent defenders. This paper presents a unified training approach that integrates Cybersecurity Test and Evaluation (T&E) with data science techniques using Jupyter Notebooks as the interactive lab environment. The program centers on a modular, scenario-driven curriculum designed to build not just knowledge but practical capability in the assessment and defense of radiation detection systems, firmware interfaces, and operational security postures.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Proactive Intrusion Detection and Mitigation System

SAND2023-05661O The proactive intrusion detection and mitigation system (PIDMS) provides grid-edge situational awareness for cybersecurity defense by capturing real-time distributed energy resource (DER) network traffic and performance data with a novel approach that improves the detection and prevention of cyber-physical attacks. The PIDMS addresses the grid-edge security gap with real-time analysis of both network traffic and photovoltaic performance data to deliver a novel, cyber-physical intrusion detection system (IDS) approach that increases the accuracy and effectiveness of detection and mitigation. This hybrid IDS analysis enables dual monitoring that increases the workload of the adversary; both cyber and physical data would have to be simultaneously spoofed to evade detection. Furthermore, monitoring and analyzing cyber data are insufficient in some cases. For example, in an insider threat aimed at disrupting inverter grid-support functions where proper credentials and authentication are achieved, only the altered PV performance would indicate abnormal behavior. All in all, the PIDMS provides novel capabilities for: • Distributed, real-time cyber-physical detection and mitigation analysis • Cybersecurity defense for grid-edge systems • Analysis framework that can provide situational awareness across the transmission, distribution, and DER systems The PIDMS sensor is designed to collect cyber-physical data, process the data using machine-learning algorithms, detect abnormal events, and deploy mitigations. With these goals, the main functional PIDMS objectives are: • Capability to collect cyber-physical data • Onboard storage of cyber-physical data • Peer-to-peer communication • Computationally efficient machine-learning algorithms • Online cyber-physical data analysis • Alerting/visualization capabilities • Mitigation deployment capability with bump-in-the-wire (BITW) implementation Each of these functional objectives enable PIDMS to perform effective cyber-physical intrusion detection and mitigation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Jones, Christian↗

Challenges of future high power wireless power transfer for light-duty electric vehicles----technology and risk management

Wireless power transfer is a state-of-the-art technology with the advantage of convenience and flexibility, as well as the capability of enabling fully automated charging. With power transfer levels increasing beyond 100 kW, many technical and risk management challenges emerge. Here, instead of focusing on the progress review of wireless power transfer technology, this paper discusses the future challenges and risks for high power wireless charging for light-duty electric vehicles. Aiming at 200 kW or higher wireless power transfer, we discuss technology and risk management challenges in the area of electromagnetic safety, resonant frequency determination, and cybersecurity risks in detail. As potential solutions to overcome these challenges, the latest technologies with an emphasis on advanced shielding solutions and recent progress on SiC converters from both industrial and academic institutions are reviewed, and some perspectives and propositions are provided.

25 ENERGY STORAGE↗

Towards Software Bill of Materials in the Nuclear Industry

Large, modern industrial facilities often incorporate thousands of digital assets in their operational technology. Regulated facilities, such as nuclear power plants (NPPs), maintain robust cybersecurity and configuration management programs that often use bills of materials (BOMs) for these assets, including make, model, and version of hardware, firmware, and software. However, these BOMs typically capture only first- or second-tier information provided by the original equipment manufacturer (OEM). Unfortunately, as indicated by the increasing number and sophistication of software supply chain attacks, this level of detail is insufficient for identifying all the potential vulnerabilities and risks in software applications. Software BOMs (SBOMs) provide detailed enumeration of components and dependencies within the product or devices, including firmware. SBOMs can be combined with vulnerability data sources and vendor vulnerability attestations to improve vulnerability management and enable rapid identification of affected components when new software vulnerabilities are discovered. Ideally, SBOMs are created by the OEM prior to installation. However, since this practice is not yet commonplace and since NPPs are typically slow to adopt new technology, most NPPs do not incorporate SBOMs into their asset or configuration management programs. Fortunately, SBOMs can be generated by NPPs on existing digital assets to provide further insight into risk management decisions. This report provides an overview of the current SBOM ecosystem and recommends guidance on how to get started in a “crawl, walk, run” manner to develop and implement a sustainable SBOM program for digital assets in an NPP.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Washington State Cyber Incident Response Summit Event Report

On September 7 and 8, 2022, Pacific Northwest National Laboratory and Washington State Adjutant General Major General Bret Daugherty, with support from the Department of Homeland Security Cybersecurity and Infrastructure Security Agency, hosted the Washington State Cyber Incident Response Summit at Camp Murray in Washington State. The invite-only summit convened 40 key decision makers and stakeholders from across the state to discuss strategies and pilot a collaborative approach to improve cyber incident response readiness within Washington. In small working groups, participants shared incident response lessons learned, best practices, and opportunities for improvement within the water and transportation sectors. This report highlights the details of the workshop presentations and discussions.

97 MATHEMATICS AND COMPUTING↗

The Distributed Energy Resource Risk Manager

Organizations need a comprehensive approach to managing security and privacy risks, especially for energy resources that are becoming increasingly distributed. A tool by the National Renewable Energy Laboratory (NREL) makes it possible to manage these risks and maintain the highest standards of cybersecurity. To simplify risk management for facilities and distributed energy resources, NREL has created the Distributed Energy Resource Risk Manager, an automated, user-friendly tool that helps navigate and implement one of the most widely trusted frameworks for information security, the National Institute of Standards and Technology Risk Management Framework.

compliance↗

A National Secure-by-Design Strategy

The US National Cybersecurity Strategy published March 2, 2023 uses plain language to communicate that the US is calling for a major change in how we prioritize the security of software systems used in critical infrastructure. It acknowledges that our current approach, which is essentially, “let the buyer beware,” leaves entities who are least able to assess or defend vulnerable software responsible for the impacts of designed-in weaknesses while the makers of the technology bear no liability. The strategy recommends a security-by-design approach, recommending that software vendors be held liable to uphold a “duty of care” to consumers and for systems to be designed to “fail safely and recover quickly” . For energy infrastructure, the strategy calls out the need to implement the National Cyber-Informed Engineering Strategy to achieve higher confidence security for energy infrastructures. The Idaho National Laboratory, a pioneer in cyber-informed engineering concepts, is at the forefront of organizations educating others in industry, academia, and government on how to apply these concepts to real-world challenges. In this brief, we'll outline some of the basic principles of security-by-design and offer examples of how, in a water sector context, they're being put into successful practice.

42 ENGINEERING↗

Operational Process for Trigger Identification and Comprehension (OPTIC)

The Operational Process for Trigger Identification and Comprehension (OPTIC) is a standalone, downloadable application designed to enhance the CyOTE (Cybersecurity for the Operational Technology Environment) methodology and will be made available for free download to industry. OPTIC brings key CyOTE functionalities into focus. OPTIC aids OT professionals in analyzing and determining whether an observed anomaly may indicate possible malicious activity or merely a maintenance related irregularity.

99 GENERAL AND MISCELLANEOUS↗

Bayesian Attack Model (BAM)

The Bayesian Attack Model (BAM) is an analytical tool designed to enhance the comprehension of adversarial activity in OT environments. BAM leverages both expert cybersecurity insights and historical data to characterize the likelihood of adversarial behavior given anomalous observable events.

99 GENERAL AND MISCELLANEOUS↗

Cyber Risk Considerations for Nuclear Digital I&C Systems

Many engineers and scientists researching modeling and analysis methods for nuclear energy advancement are focused on proof-of-concept and early-stage development for new reactor designs. Since instrumentation and control (I&C) systems are traditionally developed later in the systems engineering lifecycle, researchers may be unfamiliar with modern digital technology used in these I&C systems. It is even more likely that they are unfamiliar with the cyber risks associated with them. This paper provides a brief overview of nuclear digital I&C systems before examining the importance of cyber risk management at nuclear reactors and the benefits of including Cyber-Informed Engineering throughout the systems engineering lifecycle. The primary goal is for engineers and scientists to develop a mindset that incorporates cybersecurity as another discipline alongside safety when designing and developing new technologies, regardless of technology readiness level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Reactor Control and Operations (ARCO): A University Research Facility for Developing Optimized Digital Control Rooms

The Advanced Reactor Control and Operations (ARCO) facility was constructed in January 2018 to serve as a test bed for advanced reactor control rooms and operator support systems. Since then, it has supported human-machine interface user experience research, fault detection and mitigation technology development, control room concept of operations development, and remote operations research. ARCO serves as the control room for the Compact Integral Effects Test (CIET) facility, which replicates the primary-side flow paths and thermal-hydraulic behavior of a fluoride-salt-cooled high-temperature reactor (FHR) using simulant fluids and scaling principles. New reactor designs feature different operating conditions and scenarios than those in existing reactors. ARCO supports the research and development of digital tools for operator communications, intuitive real-time data analysis, online health monitoring and prognostics, and control room cybersecurity. By integrating these different technologies, ARCO acts as a prototypical control system to iteratively develop methods and tools of operation in advanced small modular nuclear reactors. This paper describes the features of and challenges to operating advanced small modular reactors underlying the design basis for ARCO and its operator support systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Secure and Cost-Effective Micro Phasor Measurement Unit (PMU)-Like Metering for Behind-the-Meter (BTM) Solar Systems using Blockchain-Assisted Smart Inverters

Recently, there is increasing interest in using behind-the-meter (BTM) solar systems for grid services. However, providing visibility and operational situational awareness of BTM solar systems mainly operated by small-scale solar inverters is challenging due to the requirement of relatively expansive networked observation tools (e.g., micro phasor measurement units (µPMUs)) and consequent cybersecurity threats through networks. This paper presents a secure, cost-effective, µPMUs-like metering method using a blockchain-assisted smart (BAS) inverters for a BTM solar system. The proposed BAS inverter consisting of an internet of things device as a node of a local blockchain network enables the secure provision of inverter measurement data for grid services. The BAS inverter sends the encrypted local measurement data with a timestamp to a local blockchain miner. Once the blockchain miner generates a tamper-resistant metering ledger including the measurements, it is used to assess the situational awareness of the BTM solar system. The concept of the proposed metering using the BAS inverters is validated by experimental studies.

behind the meter↗

Blockchain-Based Man-in-the-Middle (MITM) Attack Detection for Photovoltaic Systems

Cybersecurity of photovoltaic (PV) systems entails a much larger scope than just encryption and firewall of communications. For instance, integrity of data in transit between inverters and a cloud server can be compromised by authorized third-party, devices, and internal network within security perimeter (i.e., man-in-the-middle (MITM) attack). To address this challenge, this paper proposes a blockchain-based MITM attack detection method for a PV system. A breakthrough method includes screening network data, network intrusion detection, and hash comparison of in-transit data using distributed ledgers. Furthermore, the proposed method is implemented in Internet-of-Thing (IoT) security modules as clients of a blockchain network and validated by experiments.

blockchain↗

Secure Firmware Update and Device Authentication for Smart Inverters using Blockchain and Physically Uncloable Function (PUF)-Embedded Security Module

Cybersecurity of inverters has been significantly important as inverters become smarter in cyber-physical environments. However, firmware security of smart inverters against firmware attacks from various attack vectors has been less studied. Furthermore, this paper proposes a secure firmware update and device authentication method using a blockchain-based public key infrastructure (PKI) management system and a physically unclonable function (PUF)-embedded security module in a smart inverter. The proposed method is validated by experiments.

blockchain↗

Enabling a Decentralized Smart Grid Using Autonomous Edge Control Devices

As a large number of distributed devices are connected to the modern smart grid, the traditional centralized connectivity models fail to provide economic value. These models have relied on sending data to the cloud for processing and receiving commands to exert control actions, resulting in an ‘on-demand system’ with high bandwidth, low latency and an overload of data on the cloud. For realizing a decentralized system, there is a strong need to embed intelligence at the ‘edge of the network’. These intelligent devices, capable of sensing, local data processing and exerting control actions, report only actionable information to the cloud, acting as an edge control node. The system can then function autonomously, without constant cloud inputs, tolerating longer delays in communication, making the overall system ultra-low cost. The Global Asset Monitoring, Management and Analytics (GAMMA) Platform is a novel ultralow- cost, secure platform that operates through a Bluetooth based delay tolerant network. It relies on so-called ‘data mules’ to bridge the last mile connectivity gap in an inherently secure way. Due to this model, the platform requires no in-country certifications, does not rely on a dedicated backhaul technology and is immune to technology migration. This architecture also addresses some gaps identified in traditional IoT-based solutions in remote areas and sparse connectivity. A functional unit of the edge computing node has been built, taking into account various constraints like costs, customizations, data storage, cybersecurity and power management. Here, the platform has been built, deployed and has demonstrated distributed smart grid applications like power quality sensing, automated metering infrastructure and utility asset monitoring.

42 ENGINEERING↗

Model Residuals as Shields: A Two-Level Formulation to Defend Smart Grids From Poisoning Attacks

The advancement of smart grids presents both vast opportunities and heightened cybersecurity risks. Data-driven defense mechanisms, though designed as a shield against these threats, can fall prey to poisoning attacks. We delve into regression settings, underscoring the imperative to fortify defenses against a spectrum of poison ratios, notably those above 0.5—an issue scarcely addressed in prior studies. Recognizing the susceptibilities of smart grids and their manipulable sensors, we exploit the very intent of poisoning attacks, compromising model accuracy, as our defense mechanism. Our proposed two-level optimization framework discerns between poisoned and authentic data based on model residuals, outperforming or matching existing methods in 72% to 77% of precision and 75% to 80% of recalls across various poisoning attacks, poison ratios, and datasets. Once the authentic data are identified, the trained model is adaptable for a variety of applications. Comprehensive evaluations on different smart grid datasets, pitted against myriad poisoning schemes, validate our methodology’s edge over existing methods. Here, we also shed light on the implications of model misspecification originating from temporal auto-correlation, a common feature in Internet of Things and smart grid data.

Adversarial machine learning (ML)↗

Model-Based Detection of Coordinated Attacks (DCA) in Distribution Systems

The fast-paced growth in digitization of smart grid components enhances system observability and remote-control capabilities through efficient communication. However, enhanced connectivity results in heightened system vulnerability towards cybersecurity risks in the cyber-physical power system. Coordinated cyber-attacks (CCA), when undetected, lead to system-wide impact in terms of large disturbances or widespread outages. Detecting CCA in the cyber layer is critical to thwart cyber-attacks in real-time before the attack impacts the physical system. The challenge of locating CCA stems from the complex grid dynamics, making it difficult to distinguish between normal operational variations and cyber-attack impact. CCA often employs multiple attack vectors targeting geographically distributed components, further complicating CCA identification. Existing research in intrusion detection is primarily focused on the transmission network and limited to detecting individual attacks. In this paper, a novel proactive DCA strategy is proposed for early detection of CCA by establishing correlations among distinct attack events through model-based reinforcement learning that utilizes abductive reasoning to conclude the attacker goal. The solution includes understanding the system model, learning the system dynamics, and correlating individual cyber-attacks to extract the attacker’s objective. The developed learning algorithm identifies the most probable attack path to reach the attacker’s objective by predicting the next attack steps. A DNP3-based cyber-physical co-simulation testbed is developed to test the proposed algorithm using the IEEE 13-node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Verifying the Computational Integrity of Power Grid Controls with Zero-Knowledge Proof

The control of future power grids is migrating from a centralized to a distributed/decentralized scheme to enable a massive penetration of distributed energy resources with rising dependence on communication infrastructure. A common assumption made for most existing distributed/decentralized controllers is that local controllers would faithfully follow the designated controller dynamics based on the data received from communication channels. However, with increased probability of cyberattacks on Operational Technology infrastructure, such an assumption could be risky because proper execution of the controller dynamics is then built on trust in secure communication and computation. In this work, we leverage a cryptography technology known as zero-knowledge scalable transparent arguments of knowledge (zk-STARK) to verify the computational integrity of power grid control algorithms, with projected linear dynamics-based control schemes as the initial proof-of-concept test case. The method presented here converts the cybersecurity challenge of data integrity for grid control into a subset of computational integrity.

computational integrity↗