Search NASA⌕ Search

SEARCH · Search NASA

Results for “DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Multi-level inverter with mixed device types

Provided is a novel multi-level inverter with mixed device types and methods of controlling same. This novel multi-level inverter topology and control method allows the use of high frequency switching devices for controlled PWM switching, while also using lower frequency switching devices for directional switches. This combination of high frequency PWM switching devices with low frequency directional switching devices allows a cost reduction without a significant performance degradation.

Mekonnen, Ezana T.↗

In-Situ Gamma Radiation Mapping Device - 19353

The SRNL developed GrayQb{sup TM} is a passive, low cost gamma radiation mapping device which uses a tungsten pinhole and a phosphor storage plate (PSP) to generate images. Presently, the device requires retrieval to extract images off the PSP using an external scanner. In partnership with Los Alamos National Lab (LANL), SRNL has developed an in-situ GrayQb{sup TM} radiation mapping device eliminating the need to remove the radiation sensitive phosphor storage plate (PSP) from the device for scanning between exposures. By incorporating a customized version of the LANL patented MiniMax camera-based PSP reader system into the GrayQb{sup TM} housing, the exposed PSP can now be read in-situ and digitally transmitted to a remote computer for viewing. In-situ imaging is a valuable addition to GrayQb{sup TM} because of the reduced need of personnel interaction which mitigates risk as well as the option for multiple images being acquired during one deployment. Upgrades implemented which allow for in-situ imaging to be performed include using the tungsten pinhole, a PSP, red LEDs, a blue light filter, and a commercial off the shelf (COTS) color camera. The images are transmitted wirelessly to an external computer. This presentation will discuss the selection, characteristics, and testing of the camera-based PSP reading system, improved PSP materials, and the results/performance of the upgraded GrayQb{sup TM} device. Testing has been performed with simulated radiation exposures as well as A-241 and Cs-137 button sources. These upgrades and tests have been performed over a 12-month period and this presentation will be a summary and conclusion to this year long project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and implementation of wearable devices in machine tools monitoring system - 279

The world's fourth industrial revolution has finally opened after the term Industry 4.0 was proposed by Germany at the Hannover Industrial Fair in 2011, which combined industrial production with an unmanned plant to perform automated production. With the rise of Internet of Things (IoT), cloud computing, and wearing computerized devices has brought more convenience to mankind with the immediate accessibility of the Internet and technology. For example, the development of mobile devices and network technology has inspired the rapid development of wearable devices on mobile devices. Thus, to enhance the current prospects of Taiwan's unmanned machinery factory's monitoring and maintenance capabilities, this paper studies the use of Google glass Machine Tools Monitoring system, GMTM system, to be implemented in Taiwan's machinery factories. GMTM system, via the Internet, monitors sensor tools to collect tool work data to be transferred to cloud computing for analysis, processing and show the actual working conditions of each machine tool. Furthermore, the proposed system uses the monitoring data in the database to inform the factory supervisors the working status of each machine to determine whether there is a need for machine tool maintenance. This system combines real-time monitoring of material with the presentation of Google Glass wearable devices and iBeacon interior space positioning technology. GMTM system can improve the quality of machine tool production and productivity as well as enhance Taiwan's industrial competitiveness. (authors)

47 OTHER INSTRUMENTATION↗

Electron beam directed energy device and methods of using same

A method and apparatus is disclosed for an electron beam directed energy device. The device consists of an electron gun with one or more electron beams. The device includes one or more accelerating plates with holes aligned for beam passage. The plates may be flat or preferably shaped to direct each electron beam to exit the electron gun at a predetermined orientation. In one preferred application, the device is located in outer space with individual beams that are directed to focus at a distant target to be used to impact and destroy missiles. The aimings of the separate beams are designed to overcome Coulomb repulsion. A method is also presented for directing the beams to a target considering the variable terrestrial magnetic field. In another preferred application, the electron beam is directed into the ground to produce a subsurface x-ray source to locate and/or destroy buried or otherwise hidden objects including explosive devices.

47 OTHER INSTRUMENTATION↗

Device Physics of Nanoscale Interdigitated Solar Cells (Poster)

Nanoscale interdigitated solar cell device architectures are being investigated for organic and inorganic solar cell devices. Due to the inherent complexity of these device designs quantitative modeling is needed to understand the device physics. Theoretical concepts have been proposed that nanodomains of different phases may form in polycrystalline CIGS solar cells. These theories propose that the nanodomains may form complex 3D intertwined p-n networks that enhance device performance.Recent experimental evidence offers some support for the existence of nanodomains in CIGS thin films. This study utilizes CIGS solar cells to examine general and CIGS-specific concepts in nanoscale interdigitated solar cells.

14 SOLAR ENERGY↗

Investigation of Junction Properties of CdS/CdTe Solar Cells and their Correlation to Device Properties (Presentation)

The objective of the Junction Studies are: (1) understand the nature of the junction in the CdTe/CdS device; (2) correlate the device fabrication parameters to the junction formation; and (3) develop a self consistent device model to explain the device properties. Detailed analysis of CdS/CdTe and SnO{sub 2}/CdTe devices prepared using CSS CdTe is discussed.

14 SOLAR ENERGY↗

Managing age-related changes in device radiation-response.

Aging effects in silicon electronics are a concern for systems with prolonged service lives that contain electronics not easily accessible for testing and replacement. Such effects are especially difficult to assess for components that must be exposed to, and function in, transient radiation environments. A methodology has been developed that utilizes electrical parametric and non-destructive laser testing techniques, charge collection microscopy, and controlled-environment storage to permit periodic reassessment of the state of health of such electronics. The use of a scanned, focused laser, charge collection microscopy technique, developed to detect the onset of change and then track these changes in charge collection efficiency with micron resolution, will be described. These results are then used to direct subsequent failure analyses using high-sensitivity, high spatial resolution materials analysis techniques, (such as Time-of-Flight SIMS), in order to identify the underlying material driver of the aging. It will be shown how the results of this methodology are used to create finite-element, charge transport, device models of age-affected devices, and how the time-dependence of the underlying material change is incorporated into the device aging model, so as to predict the future rate, and end-state, of the identified device aging process. Lastly the model is validated using wavelength-dependent charge collection microscopy measurements of the device's response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microfluidic device and method for focusing, segmenting, and dispensing of a fluid stream

A microfluidic device and method for forming and dispensing minute volume segments of a material are described. In accordance with the present invention, a microfluidic device and method are provided for spatially confining the material in a focusing element. The device is also adapted for segmenting the confined material into minute volume segments, and dispensing a volume segment to a waste or collection channel. The device further includes means for driving the respective streams of sample and focusing fluids through respective channels into a chamber, such that the focusing fluid streams spatially confine the sample material. The device may also include additional means for driving a minute volume segment of the spatially confined sample material into a collection channel in fluid communication with the waste reservoir.

47 OTHER INSTRUMENTATION↗

In situ scanning tunneling microscope tip treatment device for spin polarization imaging

A tip treatment device for use in an ultrahigh vacuum in situ scanning tunneling microscope (STM). The device provides spin polarization functionality to new or existing variable temperature STM systems. The tip treatment device readily converts a conventional STM to a spin-polarized tip, and thereby converts a standard STM system into a spin-polarized STM system. The tip treatment device also has functions of tip cleaning and tip flashing a STM tip to high temperature (>2000.degree. C.) in an extremely localized fashion. Tip coating functions can also be carried out, providing the tip sharp end with monolayers of coating materials including magnetic films. The device is also fully compatible with ultrahigh vacuum sample transfer setups.

47 OTHER INSTRUMENTATION↗

Fluidic nanotubes and devices

Fluidic nanotube devices are described in which a hydrophilic, non-carbon nanotube, has its ends fluidly coupled to reservoirs. Source and drain contacts are connected to opposing ends of the nanotube, or within each reservoir near the opening of the nanotube. The passage of molecular species can be sensed by measuring current flow (source-drain, ionic, or combination). The tube interior can be functionalized by joining binding molecules so that different molecular species can be sensed by detecting current changes. The nanotube may be a semiconductor, wherein a tubular transistor is formed. A gate electrode can be attached between source and drain to control current flow and ionic flow. By way of example an electrophoretic array embodiment is described, integrating MEMs switches. A variety of applications are described, such as: nanopores, nanocapillary devices, nanoelectrophoretic, DNA sequence detectors, immunosensors, thermoelectric devices, photonic devices, nanoscale fluidic bioseparators, imaging devices, and so forth.

47 OTHER INSTRUMENTATION↗

Infrared Nanoimaging of Hydrogenated Perovskite Nickelate Memristive Devices

Solid-state devices made from correlated oxides, such as perovskite nickelates, are promising for neuromorphic computing by mimicking biological synaptic function. However, comprehending dopant action at the nanoscale poses a formidable challenge to understanding the elementary mechanisms involved. Here, we perform operando infrared nanoimaging of hydrogen-doped correlated perovskite, neodymium nickel oxide (H-NdNiO 3 , H-NNO), devices and reveal how an applied field perturbs dopant distribution at the nanoscale. This perturbation leads to stripe phases of varying conductivity perpendicular to the applied field, which define the macroscale electrical characteristics of the devices. Hyperspectral nano-FTIR imaging in conjunction with density functional theory calculations unveils a real-space map of multiple vibrational states of H-NNO associated with OH stretching modes and their dependence on the dopant concentration. Moreover, the localization of excess charges induces an out-of-plane lattice expansion in NNO which was confirmed by in situ X-ray diffraction and creates a strain that acts as a barrier against further diffusion. Our results and the techniques presented here hold great potential for the rapidly growing field of memristors and neuromorphic devices wherein nanoscale ion motion is fundamentally responsible for function.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Memory effects in a Al/Ti:HfO{sub 2}/CuPc metal-oxide-semiconductor device

Metal oxide semiconductor structured organic memory device has been successfully fabricated. Ti doped hafnium oxide (Ti:HfO{sub 2}) nanoparticles has been fabricated by precipitation method and further calcinated at 800 °C. Copper phthalocyanine, a hole transporting material has been utilized as an organic semiconductor. The electrical properties of the fabricated device have been studied by measuring the current-voltage and capacitance-voltage characteristics. The amount of charge stored in the nanoparticles has been calculated by using flat band condition. This simple approach for fabricating MOS memory device has opens up opportunities for the development of next generation memory devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Enabling Long Term, Shelf‐Stable Perovskite Solar Cells: Alumina Barriers to Protect Perovskite Devices from Moisture and Oxygen

Current encapsulation architectures for thin-film metal halide perovskite do not adequately eliminate all ambient stressors. Here, we develop low transmission rate barrier layers using atomic layer deposited (ALD) aluminum oxide grown directly on the completed photovoltaic (PV) device stack to provide an additional seal, prior to full packaging. We investigate the effect of deposition temperature and oxidant chemistries on the barrier growth for protection of perovskite photovoltaic devices. We characterize the layers individually, then integrate into devices to detail the tradeoff between protection and deposition compatibility. To enhance compatibility and impermeability, we present an approach using water as the aluminum oxidant during nucleation and switching from water to ozone for the remainder of the growth. At 50 nm, the barrier results in a water vapor transmission rate (WVTR) of 4.5·10 −4 g/m 2 /day, and 1,000-hour device stability under 45°C with 85% relative humidity without further packaging. This barrier provides sufficient protection to enable minimal degradation of the perovskite solar cells while completely submerged in water for 140 minutes. Additionally, we characterize the oxygen transmission rate (OTR) to be 0.49 cm 3 /m 2 /day at 23°C and 0% relative humidity, which is 1.5 orders of magnitude improvement over the OTR of the current encapsulation.

14 SOLAR ENERGY↗

Design and biocompatibility of endovascular aneurysm filling devices

We report that the rupture of an intracranial aneurysm, which can result in severe mental disabilities or death, affects approximately 30,000 people in the United States annually. The traditional surgical method of treating these arterial malformations involves a full craniotomy procedure, wherein a clip is placed around the aneurysm neck. In recent decades, research and device development have focused on new endovascular treatment methods to occlude the aneurysm void space. These methods, some of which are currently in clinical use, utilize metal, polymeric, or hybrid devices delivered via catheter to the aneurysm site. In this review, we present several such devices, including those that have been approved for clinical use, and some that are currently in development. We present several design requirements for a successful aneurysm filling device and discuss the success or failure of current and past technologies. Lastly, we also present novel polymeric based aneurysm filling methods that are currently being tested in animal models that could result in superior healing.

47 OTHER INSTRUMENTATION↗

A programmable shared-memory system for an array of processing-in-memory devices

Processing in memory (PIM), the concept of integrating processing directly with memory has been attracting a lot of attention, since PIM can assist in overcoming the throughput limitation caused by data movement between CPU and memory. The challenge, however, is that it requires the programmers to have a deep understanding of the PIM architecture to maximize the benefits such as data locality and parallel thread execution on multiple PIM devices. In this study, we present AnalyzeThat, a programmable shared-memory system for parallel data processing with PIM devices. Thematic to AnalyzeThat is a rich PIM-aware data structure (PADS), which is an encapsulation that integrally ties together the data, the analysis tasks and the runtime needed to interface with the PIM device array. The PADS abstraction provides (i) a sophisticated key-value data container that allows programmers to easily store data on multiple PIMs, (ii) a suite of parallel operations with which users can easily implement data analysis applications, and (iii) a runtime, hidden to programmers, which provides the mechanisms needed to overlay both the data and the tasks on the PIM device array in an intelligent fashion, based on PIM-specific information collected from the hardware. We have developed a PIM emulation framework called AnalyzeThat. In conclusion, our experimental evaluation with representative data analytics applications suggests that the proposed system can significantly reduce the PIM programming effort without losing its technology benefits.

97 MATHEMATICS AND COMPUTING↗

Computational study of Fermi kinetics transport applied to large-signal RF device simulations

Here, a detailed description and analysis of the Fermi kinetics transport (FKT) equations for simulating charge transport in semiconductor devices is presented. The fully coupled nonlinear discrete FKT equations are elaborated, as well as solution methods and work-flow for the simulation of RF electronic devices under large-signal conditions. The importance of full-wave electromagnetics is discussed in the context of high-speed device simulation, and the meshing requirements to integrate the full-wave solver with the transport equations are given in detail. The method includes full semiconductor band structure effects to capture the scattering details for the Boltzmann transport equation. The method is applied to high-speed gallium nitride devices. Finally, numerical convergence and stability examples provide insight into the mesh convergence behavior of the deterministic solver.

42 ENGINEERING↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Photovoltaic device innovation for a solar future

Photovoltaics (PV), also known as solar cells, are now found everywhere - in utility plants; on roofs of homes and commercial buildings; on platforms at sea; in agricultural fields; on vehicles, buildings, drones, and backpacks; and, in their longest running application, providing power in space. Continuous device innovation has led to increased efficiency and improved reliability for multiple PV technologies. Confronted with an urgent need to deploy PV at multiterawatt (TW) scale over the next two decades to mitigate greenhouse gas emissions, PV device innovation takes on new urgency and impact. This perspective reviews recent progress in device design and performance for PV technologies that are currently in commercial production at greater than 1 GW/year or enabling significant space-based power generation - Si, CdTe, CIGS, and multijunction III-V - and looks ahead to the next 5 years. In conclusion, we also identify device-related topics requiring cross-cutting research and innovation.

14 SOLAR ENERGY↗