Search NASA⌕ Search

SEARCH · Search NASA

Results for “DISPATCH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Predictive performance modeling framework for a novel enclosed particle receiver configuration and application for thermochemical energy storage

Concentrating solar power (CSP) plants can provide dispatchable power with a thermal energy storage capability for increased renewable-energy grid penetration. Particle-based CSP systems permit higher temperatures, and thus, potentially higher solar-to-electric efficiency than state-of-the-art molten-salt heat-transfer systems. This paper describes a detailed numerical analysis framework for estimating the performance of a novel, geometrically complex, enclosed particle receiver design. The receiver configuration uses arrays of small tubular absorbers to collect and subsequently transfer solar energy to a flowing particulate medium. The enclosed nature of the receiver design renders it amenable to either an inert heat-transfer medium, or a reactive heat-transfer medium that requires a controllable ambient environment. The numerical analysis framework described in this study is demonstrated for the case of thermal reduction of CaCr 0.1 Mn 0.9 O 3-$\delta$ for thermochemical energy storage. The modeling strategy consists of Monte Carlo ray tracing for absorbed solar-energy distributions from a surround heliostat field, computational fluid dynamics modeling of small-scale local tubular arrays, surrogate response surfaces that approximately capture simulated tubular array performance, a quasi-two-dimensional reduced-order description of counter-flow reactive solids and purge gas, and a radiative exchange model applied to embedded-cavity structures at the size scale of the full receiver. In this work we apply the numerical analysis strategy to a single receiver configuration, but the framework can be generically applicable to alternative enclosed designs. In conclusion, we assess sensitivity of receiver performance to surface optical properties, heat-transfer coefficients, solids outlet temperature, and purge-gas feed rates, and discuss the significance of model assumptions and results for future receiver development.

14 SOLAR ENERGY↗

Overbuilding & curtailment: The cost-effective enablers of firm PV generation

Current thinking considers that PV output curtailment is a last resort measure to be avoided. In this article, we argue that supply-shaping, achieved through proactive curtailment associated with PV oversupply, is actually critical to achieving intermittency mitigation and delivering firm PV generation at the lowest cost. We investigate the premium to transform a low-cost, but intermittent solar kWh into a firm, effectively dispatchable kWh. We show that a fundamental ingredient of minimizing this premium is to optimally overbuild and, as necessary and appropriate, curtail PV generation. Drawing on a case study in the State of Minnesota, we show that firm, high-penetration-ready PV generation could be achieved at a production cost at or below current conventional generation, especially when optimally coupled with wind generation. Here, we conclude with a recommendation that in order to achieve this lowest cost firm generation potential, proactive curtailment strategies should inform future transactional PV remuneration systems.

14 SOLAR ENERGY↗

Reduced order modeling of a fluidized bed particle receiver for concentrating solar power with thermal energy storage

Oxide particles can serve as both the heat transfer and thermal energy storage (TES) media for next-generation concentrating solar power (CSP) plants where high-temperature TES enables dispatchable electricity from efficient power cycles with firing temperatures above 600 °C. Transferring heat to flowing particles at such high temperatures in a MW-scale central tower receiver remains a challenge for the CSP community. For indirect receivers with external walls to contain the particles, maintaining wall temperatures below the limits of structural metal alloys requires high heat transfer coefficients between the wall and the moving particle stream. Bubbling fluidization of downward-flowing particles can sustain high bed-wall heat transfer coefficients (> 1000 W m -2 K -1 ). Using experimentally calibrated correlations for bed-wall heat transfer and vertical particle dispersion, this study implements an axially discretized zonal model of a counterflow fluidized bed receiver to explore how bubbling fluidization may enable indirect cavity particle receivers. High bed-wall heat transfer coefficients support solar fluxes on angled cavity walls > 200 kW m -2 at peak aperture fluxes of 980 kW m -2 while maintaining external wall temperatures < 950 °C. Lateral particle dispersion enables hotter particles near the receiver leading edge to mix with cooler particles further from the leading edge to lower maximum external wall temperatures. Parametric studies identify how mass fluxes, particle dispersion, and solar concentrations impact indirect receiver thermal efficiency and uniformity for a CSP plant. These studies provide a basis for the design of indirect fluidized-bed cavity receivers that can maintain particle outlet temperatures for TES above 750 °C.

14 SOLAR ENERGY↗

Estimating value of information for heliostat washing operations at solar thermal plants

Concentrating solar power (CSP) plants depend on thousands of heliostats whose reflectance declines as dust accumulates. Operators routinely measure reflectance to estimate soiling and, in turn, inform cleaning schedules, but the value of collecting more frequent or more accurate data has not been formally quantified. This study introduces a Monte Carlo discrete event simulation framework that integrates stochastic models of soiling, weather, and measurement error with a dynamic cleaning dispatch policy to estimate annual energy production and operations costs. Applied to two representative central-receiver field configurations, the results show that both the frequency and accuracy of reflectance measurements can meaningfully impact plant performance. In both case studies, reducing measurement intervals yields significant returns, with the energy gains greatly exceeding the cost of more frequent data collection. The simulation framework serves as a decision-support tool for CSP operators, allowing them to input site-specific soiling conditions, measurement accuracy, and survey frequency to evaluate the tradeoffs between data collection cost and energy recovery, and to identify measurement strategies that maximize plant profit.

14 SOLAR ENERGY↗

Measuring efficiency in wholesale electricity markets

The mechanisms of the bid-based economic dispatch and market power mitigation algorithms which result in the market clearing price epitomize the complexity of the new regulatory regime. The augmented Lerner Index presented here offers a method to objectively assess the efficiency of the new structure. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The marginal effects of the price for carbon dioxide: quantifying the effects on the market for electric generation in Florida

Greater emphasis on public policy aimed at internalizing the societal cost of carbon dioxide emissions leads to more questions about the economic impacts of that policy. In cooperation with the State of Florida's Department of Environmental Protection, the authors have constructed a model to simulate the dispatch of electric generating units to serve electric load in the state - and obtained some counterintuitive results. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Wind energy contribution to a low-carbon grid

Wind power systems being promoted today contribute little to a low-carbon grid because the system concept is 70-90 percent dependent on dispatchable fossil fuel generators. This structural conflict has no visible solutions. (author)

17 WIND ENERGY↗

Capacity contributions of Southern Oregon offshore wind to the Pacific Northwest and California

Variable renewable energy generation poses unique capacity challenges, which increasingly depend on weather events at varying timescales. Facilitated by transmission planning, geographic and technological diversity of the generation fleet may provide a mitigation to capacity shortfalls. In this work, offshore wind (OSW) energy is sited in the areas off the West Coast between Coos Bay, Oregon, and Crescent City, California. Three generation and transmission scenarios are modeled within the Western Interconnection: (i) 3.4 gigawatts (GW) of installed OSW capacity connected to Southern Oregon through a High Voltage Alternating Current (HVAC) Radial Topology in 2030; (ii) 12.9 GW of installed OSW capacity connected to Washington, Oregon, and California through a High Voltage Direct Current (HVDC) Radial Topology post-2030, and (iii) the same 12.9 GW connected to the same locations through a Multi-terminal DC (MTDC) Backbone Topology post-2030. Zonal dispatch simulations assuming coincident wind, solar, and hydropower production and loads over 18 meteorological years, accounting for temperature-dependent equipment derating and forced outages, serve as inputs to the Associated System Capacity Contribution (ASCC) methodology. The capacity credit is 33%, 25% and 34% for the 2030 HVAC Radial Topology, 2030+ HVDC Radial Topology, and 2030+ MTDC Backbone Topology, respectively. Transmission design is shown to mitigate the typical erosion of marginal capacity contribution as more OSW is developed, underscoring the opportunity for grid modernization while decarbonizing the generation mix.

17 WIND ENERGY↗

Implications of Power Plant Idling and Cycling on Water Use Intensity

Survey data from the Energy Information Administration (EIA) was combined with data from the Environmental Protection Agency (EPA) to explore ways in which operations might impact water use intensity (both withdrawals and consumption) at thermoelectric power plants. Two disparities in cooling and power systems operations were identified here that could impact water use intensity: 1) Idling Gap—where cooling systems continue to operate when their boilers and generators are completely idled; and 2) Cycling Gap—where cooling systems operate at full capacity, while their associated boiler and generator systems cycle over a range of loads. Analysis of the EIA and EPA data indicated that cooling systems operated on average 13% more than their corresponding power system (Idling Gap), while power systems operated on average 30% below full load when the boiler was reported as operating (Cycling Gap). Regression analysis was then performed to explore whether the degree of power plant idling/cycling could be related to the physical characteristics of the plant, its environment or time of year. While results suggested that individual power plants’ operations were unique, weak trends consistently pointed to a plant’s place on the dispatch curve as influencing patterns of cooling system, boiler, and generator operation. This insight better positions us to interpret reported power plant water use data as well as improve future water use projections.

54 ENVIRONMENTAL SCIENCES↗

Spinel Cu–Mn–Cr Oxide Nanoparticle-Pigmented Solar Selective Coatings Maintaining >94% Efficiency at 750 °C

High-temperature concentrating solar power (CSP) system is capable of harvesting and storing solar energy as heat towards cost-effective dispatchable solar electricity. Solar selective coating is a critical component to boost its efficiency by maximizing solar absorptance and minimizing thermal emittance losses. However, maintaining a high solar-thermal conversion efficiency >90% for long-term operation at ≥750 ºC remains a significant challenge. Herein, we report spray-coated spinel Cu-Mn-Cr oxide nanoparticle-pigmented solar selective coatings on Inconel tube sections maintaining ≥94% efficiency at 750 ºC and ≥92.5% at 800 ºC under 1000x solar concentration after 60 simulated day-night thermal cycles in air, each cycle comprising 12h at 750 ºC/800 ºC and 12h cooling to 25 ºC. The solar spectral selectivity is intrinsic to the band-to-band and d-d transitions of non-stoichiometric spinel Cu-Mn-Cr oxide nanoparticles. Furthermore, this feature offers a large fabrication tolerance in nanoparticle volume fraction and coating thickness, facilitating low-cost and scalable spray-coated high-efficiency solar selective absorbers for high-temperature CSP systems.

14 SOLAR ENERGY↗

Molecular Design Principles for Photosystem I-Based Biohybrid Solar Fuel Catalysts

Direct solar-to-chemical conversion offers a compelling route to clean, dispatchable energy. Photosystem I (PSI), an evolutionarily optimized light-driven oxidoreductase, can be repurposed for solar-fuel production by coupling its photochemistry to catalytic interfaces. However, the molecular determinants that govern productive electron transfer to abiotic catalysts remain poorly understood. Here, we present molecular structures of active PSI-Pt nanoparticle (PtNP) biohybrids that reveal how protein architecture controls catalyst access, binding geometry, and photocatalytic efficiency. Removal of stromal subunits exposes the electron transfer chain and enables PtNP binding proximal to the F X cluster, demonstrating that steric occlusion limits access to native acceptor regions in PSI. In contrast, in trimeric PSI, PtNPs bind at multiple sites per monomer, but only a subset are positioned within electron transfer distance of terminal cofactors, resulting in a heterogeneous population of productive and nonproductive configurations. Structural analyses and molecular dynamics simulations define the interface topology, electrostatics, and cofactor-to-nanoparticle distances that govern catalyst binding and electron transfer. These results establish that catalytic inefficiency arises not only from intrinsic electron transfer constraints but also from the distribution of binding geometries imposed by the protein scaffold. Together, these findings provide a molecular framework linking protein structure to biohybrid function and define design principles for engineering PSI-based solar fuel systems and protein-nanomaterial interfaces for light-driven catalysis.

biohybrid↗

Crystallographic and Catalytic Studies of the Peroxide-Shunt Reaction in a Diiron Hydroxylase

A diiron hydroxylase reaction typically begins by combination of O{sub 2} with a diferrous center to form reactive intermediates capable of hydrocarbon hydroxylation. In this natural cycle, reducing equivalents are provided by specific interactions with electron transfer proteins. The biological process can be bypassed by combining H{sub 2}O{sub 2} with a diferric center, i.e., peroxide-shunt catalysis. Here we show that toluene 4-monooxygenase has a peroxide-shunt reaction that is {approx}600-fold slower than catalysis driven by biological electron transfer. However, the toluene 4-monooxygenase hydroxylase-effector protein complex was stable in the presence of 300 mM H{sub 2}O{sub 2}, suggesting overall benign effects of the exogenous oxidant on active site structure and function. The X-ray structure of the toluene 4-monooxygenase hydroxylase-effector protein complex determined from crystals soaked in H{sub 2}O{sub 2} revealed a bound diatomic molecule, assigned to a cis-{mu}-1,2-peroxo bridge. This peroxo species resides in an active site position adjacent to the hydrogen-bonding substructure established by effector protein binding and faces into the distal cavity where substrate must bind during regiospecific aromatic ring hydroxylation catalysis. These results provide a new structural benchmark for how activated intermediates may be formed and dispatched during diiron hydroxylase catalysis.

59 BASIC BIOLOGICAL SCIENCES↗

Concentrating solar thermoelectric generators with a peak efficiency of 7.4%

Concentrating solar power normally employs mechanical heat engines and is thus only used in large-scale power plants; however, it is compatible with inexpensive thermal storage, enabling electricity dispatchability. Concentrating solar thermoelectric generators (STEGs) have the advantage of replacing the mechanical power block with a solid-state heat engine based on the Seebeck effect, simplifying the system. The highest reported efficiency of STEGs so far is 5.2%. We report experimental measurements of STEGs with a peak efficiency of 9.6% at an optically concentrated normal solar irradiance of 211 kW m -2 , and a system efficiency of 7.4% after considering optical concentration losses. The performance improvement is achieved by the use of segmented thermoelectric legs, a high-temperature spectrally selective solar absorber enabling stable vacuum operation with absorber temperatures up to 600 °C, and combining optical and thermal concentration. Our work suggests that concentrating STEGs have the potential to become a promising alternative solar energy technology.

14 SOLAR ENERGY↗

Compound climate events transform electrical power shortfall risk in the Pacific Northwest

Power system operations are sensitive to climate-driven variations in both energy demands and water availability. Yet the combined effect of these impacts on power system adequacy is rarely evaluated. Here we assess power shortfall risk for the U.S. Pacific Northwest under combined climate impacts on loads and hydropower generation. Climate change emerges as both a risk and an opportunity; potential shortfall events occur more readily, but are significantly less severe in nature (annual shortfall probability is more than doubled for a business as usual policy; average shortfall event duration is halved and average maximum shortfall is reduced by up to ~60%). A seasonal reversal in shortfall risk occurs: winter shortfalls are eradicated due to reduced building heating demands, whilst summer shortfalls multiply as increased peak loads for day-time cooling coincide with impaired hydropower generation. Many of these summer shortfalls go unregistered when climate change impacts on loads and hydro dispatch are analyzed in isolation—suggesting an important role of compound events.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Gold-in-copper at low *CO coverage enables efficient electromethanation of CO 2

The renewable-electricity-powered CO 2 electroreduction reaction provides a promising means to store intermittent renewable energy in the form of valuable chemicals and dispatchable fuels. Renewable methane produced using CO 2 electroreduction attracts interest due to the established global distribution network; however, present-day efficiencies and activities remain below those required for practical application. Here we exploit the fact that the suppression of *CO dimerization and hydrogen evolution promotes methane selectivity: we reason that the introduction of Au in Cu favors *CO protonation vs. C-C coupling under low *CO coverage and weakens the *H adsorption energy of the surface, leading to a reduction in hydrogen evolution. We construct experimentally a suite of Au-Cu catalysts and control *CO availability by regulating CO 2 concentration and reaction rate. This strategy leads to a 1.6× improvement in the methane:H 2 selectivity ratio compared to the best prior reports operating above 100 mA cm -2 . We as a result achieve a CO 2 -to-methane Faradaic efficiency (FE) of (56 ± 2)% at a production rate of (112 ± 4) mA cm -2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An intertemporal decision framework for electrochemical energy storage management

Dispatchable energy storage is necessary to enable renewable-based power systems that have zero or very low carbon emissions. The inherent degradation behaviour of electrochemical energy storage (EES) is a major concern for both EES operational decisions and EES economic assessments. Here in this paper, we propose a decision framework that addresses the intertemporal trade-offs in terms of EES degradation by deriving, implementing and optimizing two metrics: the marginal benefit of usage and the average benefit of usage. These metrics are independent of the capital cost of the EES system, and, as such, separate the value of EES use from the initial cost, which provides a different perspective on storage valuation and operation. Our framework is proved to produce the optimal solution for EES life-cycle profit maximization. We show that the proposed framework offers effective ways to assess the economic values of EES, to make investment decisions for various applications and to inform related subsidy policies.

25 ENERGY STORAGE↗