Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MECHANICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Communications: Mechanical Deformation of Dendrites by Fluid Flow

It is generally accepted that liquid agitation during alloy solidification assists in crystal multiplication, as in dendrite fragmentation and the detachment of side arms in the mushy region of a casting. Even without deliberate stirring by electromagnetic or mechanical means, there is often vigorous interdendritic fluid flow promoted by natural thermosolutal convection. In this analysis, we shall estimate the stress at the root of a secondary dendrite arm of aluminum arising from the action of a flow of molten metal past the dendrite arm.

Pilling, J.↗

Reliability Quantification of Advanced Stirling Convertor (ASC) Components

The Advanced Stirling Convertor, is intended to provide power for an unmanned planetary spacecraft and has an operational life requirement of 17 years. Over this 17 year mission, the ASC must provide power with desired performance and efficiency and require no corrective maintenance. Reliability demonstration testing for the ASC was found to be very limited due to schedule and resource constraints. Reliability demonstration must involve the application of analysis, system and component level testing, and simulation models, taken collectively. Therefore, computer simulation with limited test data verification is a viable approach to assess the reliability of ASC components. This approach is based on physics-of-failure mechanisms and involves the relationship among the design variables based on physics, mechanics, material behavior models, interaction of different components and their respective disciplines such as structures, materials, fluid, thermal, mechanical, electrical, etc. In addition, these models are based on the available test data, which can be updated, and analysis refined as more data and information becomes available. The failure mechanisms and causes of failure are included in the analysis, especially in light of the new information, in order to develop guidelines to improve design reliability and better operating controls to reduce the probability of failure. Quantified reliability assessment based on fundamental physical behavior of components and their relationship with other components has demonstrated itself to be a superior technique to conventional reliability approaches based on utilizing failure rates derived from similar equipment or simply expert judgment.

Shah, Ashwin R.↗

Physiologic mechanisms of circulatory and body fluid losses in weightlessness identified by mathematical modeling

Central volume expansion due to fluid shifts in weightlessness is believed to activate adaptive reflexes which ultimately result in a reduction of the total circulating blood volume. However, the flight data suggests that a central volume overdistention does not persist, in which case some other factor or factors must be responsible for body fluid losses. We used a computer simulation to test the hypothesis that factors other than central volume overdistention are involved in the loss of blood volume and other body fluid volumes observed in weightlessness and in weightless simulations. Additionally, the simulation was used to identify these factors. The results predict that atrial volumes and pressures return to their prebedrest baseline values within the first day of exposure to head down tilt (HDT) as the blood volume is reduced by an elevated urine formation. They indicate that the mechanisms for large and prolonged body fluid losses in weightlessness is red cell hemoconcentration that elevates blood viscosity and peripheral resistance, thereby lowering capillary pressure. This causes a prolonged alteration of the balance of Starling forces, depressing the extracellular fluid volume until the hematocrit is returned to normal through a reduction of the red cell mass, which also allows some restoration of the plasma volume. We conclude that the red cell mass becomes the physiologic driver for a large 'undershoot' of the body fluid volumes after the normalization of atrial volumes and pressures.

Simanonok, K. E.↗

Conceptual design for the Space Station Freedom fluid physics/dynamics facility

A study team at NASA's Lewis Research Center has been working on a definition study and conceptual design for a fluid physics and dynamics science facility that will be located in the Space Station Freedom's baseline U.S. Laboratory module. This modular, user-friendly facility, called the Fluid Physics/Dynamics Facility, will be available for use by industry, academic, and government research communities in the late 1990's. The Facility will support research experiments dealing with the study of fluid physics and dynamics phenomena. Because of the lack of gravity-induced convection, research into the mechanisms of fluids in the absence of gravity will help to provide a better understanding of the fundamentals of fluid processes. This document has been prepared as a final version of the handout for reviewers at the Fluid Physics/Dynamics Facility Assessment Workshop held at Lewis on January 24 and 25, 1990. It covers the background, current status, and future activities of the Lewis Project Study Team effort. It is a revised and updated version of a document entitled 'Status Report on the Conceptual Design for the Space Station Fluid Physics/Dynamics Facility', dated January 1990.

Thompson, Robert L.↗

Low melting temperature alloy deployment mechanism and recent experiments

This paper describes the concept of a low melting temperature alloy deployment mechanism, U.S. Patent 4,842,106. It begins with a brief history of conventional dimethyl-silicone fluid damped mechanisms. Design fundamentals of the new melting alloy mechanism are then introduced. Benefits of the new over the old are compared and contrasted. Recent experiments and lessons learned complete this paper.

Madden, M. J.↗

Evaporative Heat Transfer Mechanisms within a Heat Melt Compactor

This paper will discuss the status of microgravity analysis and testing for the development of a Heat Melt Compactor (HMC). Since fluids behave completely differently in microgravity, the evaporation process for the HMC is expected to be different than in 1-g. A thermal model is developed to support the design and operation of the HMC. Also, low-gravity aircraft flight data is described to assess the point at which water may be squeezed out of the HMC during microgravity operation. For optimum heat transfer operation of the HMC, the compaction process should stop prior to any water exiting the HMC, but nevertheless seek to compact as much as possible to cause high heat transfer and therefore shorter evaporation times.

Heat Transfer↗

Extending mARC II Arc-Jet Test Duration via Design and Implementation of Model System Cooling Sleeve

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.

sting arm↗

Non-linear resonance of fluids in a crystal growth cavity

In the microgravity environment, the effect of gravity on fluid motion is much reduced. Hence, secondary effects such as vibrations, jitters, surface tension, capillary effects, and electromagnetic forces become the dominant mechanism of fluid convection. Numerous studies have been conducted to investigate fluid behavior in microgravity with the ultimate goal of developing processes with minimal influence from convection. Industrial applications such as crystal growth from solidification of melt and protein growth for pharmatheutical application are just a few examples of the vast potential benefit that can be reaped from material processing in space. However, a space laboratory is not immune from all undesirable disturbances and it is imperative that such disturbances be well understood, quantifiable, and controlled. Non-uniform and transient accelerations such as vibrations, jitters, and impulsive accelerations exist as a result of crew activities, space vehicle maneuvering, and the operations of on-board equipment. Measurements conducted on-board a U.S. Spacelab showed the existence of vibrations in the frequency range of 1 to 100 Hz with a dominant mode of 17 Hz and harmonics of 54 Hz. The observed vibration is not limited to any coordinate plane but exists in all directions. Similar situation exists on-board the Russian MIR space station. Due to the large structure of its design, the future International Space Station will have its own characteristic vibration spectrum. It is well known that vibration can exert substantial influence on heat and mass transfer processes, thus hindering any attempts to achieve a diffusion-limited process. Experiments on vibration convection for a liquid-filled enclosure under one-g environment showed the existence of different flow regimes as vibration frequency and intensity changes. Results showed the existence of a resonant frequency, near which the enhancement is the strongest, and the existence of a high frequency asymptote. Numerical simulations of vibration convection have been conducted by Yurkov, Fu and Shieh, and by Wang. These analyses considered a two-dimensional air-filled cell under weightlessness condition and showed results similar to those of the experiments. It is not yet known whether resonance convection can be triggered by jitter alone or whether it requires the interaction of jitter with other convective forces in low gravity. An order of magnitude analysis, however, can be used to show the dependence of the resonance frequency on the fluid Prandtl number. Even though the onset of resonance convection may depend on other factors, results indicates that fluids with low Prandtl numbers are more susceptible to resonance than those with high Prandtl numbers. The current study is aimed at gaining additional insights to this problem using germanium as working fluid. Germanium was chosen for this analysis because of its common usage in solidification process and its relatively low Prandtl number (Pr = 0.02).

Wang, Francis C.↗

Combined buoyancy-thermocapillary convection

Combined buoyancy-thermocapillary convection was studied in 2D and 3D. Fluid motion caused by thermally induced tension gradients on the free surface of a fluid is termed thermocapillary convection. It is well-known that in containerless processing of materials in space, thermocapillary convection is a dominant mechanism of fluid flow. Welding and crystal growth processes are terrestrial applications where thermocapillary convection has direct relevance.

Homsy, G. M.↗

Thermocapillary Convection in Liquid Droplets

The purpose of this video is to understand the effects of surface tension on fluid convection. The fluid system chosen is the liquid sessile droplet to show the importance in single crystal growth, the spray drying and cooling of metal, and the advance droplet radiators of the space stations radiators. A cross sectional representation of a hemispherical liquid droplet under ideal conditions is used to show internal fluid motion. A direct simulation of buoyancy-dominant convection and surface tension-dominant convection is graphically displayed. The clear differences between two mechanisms of fluid transport, thermocapillary convection, and bouncy dominant convection is illustrated.

Source record↗

Exploration of Impinging Water Spray Heat Transfer at System Pressures Near the Triple Point

The heat transfer of a water spray impinging upon a surface in a very low pressure environment is of interest to cooling of space vehicles during launch and re-entry, and to industrial processes where flash evaporation occurs. At very low pressure, the process occurs near the triple point of water, and there exists a transient multiphase transport problem of ice, water and water vapor. At the impingement location, there are three heat transfer mechanisms: evaporation, freezing and sublimation. A preliminary heat transfer model was developed to explore the interaction of these mechanisms at the surface and within the spray.

Heat Transfer↗

Fluid Line Evacuation and Freezing Experiments for Digital Radiator Concept

The digital radiator technology is one of three variable heat rejection technologies being investigated for future human-rated NASA missions. The digital radiator concept is based on a mechanically pumped fluid loop with parallel tubes carrying coolant to reject heat from the radiator surface. A series of valves actuate to start and stop fluid flow to di erent combinations of tubes, in order to vary the heat rejection capability of the radiator by a factor of 10 or more. When the flow in a particular leg is stopped, the fluid temperature drops and the fluid can freeze, causing damage or preventing flow from restarting. For this reason, the liquid in a stopped leg must be partially or fully evacuated upon shutdown. One of the challenges facing fluid evacuation from closed tubes arises from the vapor generated during pumping to low pressure, which can cause pump cavitation and incomplete evacuation. Here we present a series of laboratory experiments demonstrating fluid evacuation techniques to overcome these challenges by applying heat and pumping to partial vacuum. Also presented are results from qualitative testing of the freezing characteristics of several different candidate fluids, which demonstrate significant di erences in freezing properties, and give insight to the evacuation process.

human space flight↗

Radiant energy absorption studies for laser propulsion

A study of the energy absorption mechanisms and fluid dynamic considerations for efficient conversion of high power laser radiation into a high velocity flow is presented. The objectives of the study are: (1) to determine the most effective absorption mechanisms for converting laser radiation into translational energy, and (2) to examine the requirements for transfer of the absorbed energy into a steady flow which is stable to disturbances in the absorption zone. A review of inverse Bremsstrahlung, molecular and particulate absorption mechanisms is considered and the steady flow and stability considerations for conversion of the laser power to a high velocity flow in a nozzle configuration is calculated. A quasi-one-dimensional flow through a nozzle was formulated under the assumptions of perfect gas.

Caledonia, G. E.↗

Origin of the Two Scales of Wind Ripples on Mars

Earth's sandy deserts host two main types of bedforms - decimeter-scale ripples and larger dunes. Years of orbital observations on Mars also confirmed the existence of two modes of active eolian bedforms - meter-scale ripples, and dunes. By analogy to terrestrial ripples, which are thought to form from a grain mechanism, it was hypothesized that large martian ripples also formed from grain impacts, but spaced further apart due to elongated saltation trajectories from the lower martian gravity and different atmospheric properties. However, the Curiosity rover recently documented the coexistence of three scales of bedforms in Gale crater. Because a grain impact mechanism cannot readily explain two distinct and coeval ripple modes in similar sand sizes, a new mechanism seems to be required to explain one of the scales of ripples. Small ripples are most similar to Earth's impact ripples, with straight crests and subdued profiles. In contrast, large martian ripples are sinuous and asymmetric, with lee slopes dominated by grain flows and grainfall deposits. Thus, large martian ripples resemble current ripples formed underwater on Earth, suggesting that they may form from a fluid-drag mechanism. To test this hypothesis, we develop a scaling relation to predict the spacing of fluid-drag ripples from an extensive flume data compilation. The size of large martian ripples is predicted by our scaling relation when adjusted for martian atmospheric properties. Specifically, we propose that the wavelength of martian wind-drag ripples arises from the high kinematic viscosity of the low-density atmosphere. Because fluid density controls drag-ripple size, our scaling relation can help constrain paleoatmospheric density from wind-drag ripple stratification.

Lapotre, Mathieu G. A.↗

Europa Clipper Thermal Control Design

This paper details the design developments of the Europa Clipper spacecraft thermal control system and its primary element the Heat Redistribution System (HRS). The Europa Clipper spacecraft will launch in the early 2020s and will have multiple flybys of Jupiter’s icy moon, Europa. The HRS, which utilizes a Mechanically Pumped Fluid Loop (MPFL) to reclaim waste heat from an avionics vault module and redistribute it to the propulsion module and radiator, has become an integral part of the spacecraft architecture both in terms of mechanical configuration and spacecraft operations capability. A walkthrough on the planned implementation of the HRS on the primary spacecraft modules is provided along with a description on thermal control of spacecraft hardware not located on the HRS vault, where thermal isolation and tolerance to extreme thermal environment drives the hardware designs.

Bhandari, Pradeep↗

Extending mARC II Arc-Jet Test Duration via Design and Implementation of Model System Cooling Sleeve

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.

numerical simulations↗

Fitting Leak Test Report: Ground-Based Cryogenic Leak Test of Fittings for Cryogenic Fluid Management

EXECUTIVE SUMMARY Mechanically connected joints used in cryogenic fluid lines as part of space flight elements need to survive launch vibrations and remain leak-free to minimize the loss of on-board commodity and hazardous gas accumulation. In 2020, a cryogenic test apparatus was developed which can evaluate the leak performance of pressurized threaded fluid fittings. The fittings were mounted in the TVAC and cooled to cryogenic test temperature and pressurized with helium while the leak rate was measured using a calibrated GHe leak detector. The test articles for the initial proof of concept testing were ¼ and 1 inch Swagelok VCR fittings with three different types of seal rings copper, nickel, and Ni. Each fitting configuration (size/seal material) was subjected to two consecutive cryogenic thermal cycles, followed by exposure to a launch vibration profile at ambient temperature, after which two additional TVAC cycle tests were performed. The testing reported here is a continuation of the 2020 tests with a statistically significant large number of samples and test runs. Three Swagelok VCR fitting sizes were tested ¼, ½ and 1 inch, and five (5) samples of each fitting size, each sample was tested with SST and Ni seal rings (Total of 30 unique test articles). Each test article was subjected to four (4) thermal cycles. Half of these cycles were performed before vibration testing and half were performed after vibration testing. The vibration testing was performed to evaluate the ability of the fittings to survive launch-type vibration profiles and remain leak-free. Leak checking of each fitting was completed at temperatures between 20K – 30K. The test procedure in Section 8.0 was designed to facilitate a qualification test program by allowing a higher test throughput rate coupled with repeatable test profiles. Results were very positive and show that out of the 30 samples they all passed with leak rates a factor of 2-3 lower than the established 10-6sccs GHe leak threshold. The result showed the Ni seals had lower leak rate, but the SST was more rugged. There were two deviations where damage to the Ni seal ring during assembly resulted in a leaky fitting, this is discussed in Section 10.7 Test Deviations. These fittings show great promise for space flight use and further testing is recommended to fully qualify the fittings per the ASTM F1387-19 and/or other relevant NASA specifications. The test equipment hardware and software capability developed for this testing is generic and not restricted to VCR fittings. It can be employed to evaluate/qualify the leak performance of other types of fittings and a wide range of other cryogenic fluid components such as valves, gages, connectors, etc.

Cryogenic↗

Drinking and water balance during exercise and heat acclimation

The interactions between fluid intake and balance, and plasma ion, osmotic, and endocrine responses during dehydration produced by exercise in cool and warm environments during acclimation are explored. Two groups of five male subjects performed 8 days of ergometer exercise in hot and thermoneutral conditions, respectively. The exercise trials lasted 2 hr each. Monitoring was carried out on the PV, osmotic, sodium, and endocrine concentrations, voluntary fluid intake, fluid balances, and fluid deficits. A negative correlation was observed between the plasma sodium and osmolality during acclimation. The presence of hypervolemia during acclimation is suggested as a cause of drinking, while the vasopressin concentration was not found to be a significant factor stimulating drinking. Finally, the predominant mechanism in fluid intake during exercise and heat exposure is concluded to be the renin-angiotensin II system in the presence of reductions in total body water and extracellular plasma volumes.

Greenleaf, J. E.↗