Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

FREQUENCY DEPENDENCE OF PULSE WIDTH FOR 150 RADIO NORMAL PULSARS

The frequency dependence of the pulse width is studied for 150 normal pulsars, mostly selected from the European Pulsar Network, for which the 10% multifrequency pulse widths can be well fit with the Thorsett relationship W {sub 10} = Aν{sup μ} + W {sub 10,} {sub min}. The relative fraction of pulse width change between 0.4 GHz and 4.85 GHz, η = (W {sub 4.85} – W {sub 0.4})/W {sub 0.4}, is calculated in terms of the best-fit relationship for each pulsar. It is found that 81 pulsars (54%) have η < –10% (group A), showing considerable profile narrowing at high frequencies, 40 pulsars (27%) have –10% ≤η ≤ 10% (group B), meaning a marginal change in pulse width, and 29 pulsars (19%) have η > 10% (group C), showing a remarkable profile broadening at high frequencies. The fractions of the group-A and group-C pulsars suggest that the profile narrowing phenomenon at high frequencies is more common than the profile broadening phenomenon, but a large fraction of the group-B and group-C pulsars (a total of 46%) is also revealed. The group-C pulsars, together with a portion of group-B pulsars with slight pulse broadening, can hardly be explained using the conventional radius-to-frequency mapping, which only applies to the profile narrowing phenomenon. Based on a recent version of the fan beam model, a type of broadband emission model, we propose that the diverse frequency dependence of pulse width is a consequence of different types of distribution of emission spectra across the emission region. The geometrical effect predicting a link between the emission beam shrinkage and spectrum steepening is tested but disfavored.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of absolute transition frequencies of {sup 87}Rb to nS and nD Rydberg states by means of electromagnetically induced transparency

We report the measurement of absolute excitation frequencies of {sup 87}Rb to nS and nD Rydberg states. The Rydberg transition frequencies are obtained by observing electromagnetically induced transparency on a rubidium vapor cell. The accuracy of the measurement of each state is < or approx. 1 MHz, which is achieved by frequency stabilizing the two diode lasers employed for the spectroscopy to a frequency comb and a frequency comb calibrated wavelength meter, respectively. Based on the spectroscopic data we determine the quantum defects of {sup 87}Rb, and compare it with previous measurements on {sup 85}Rb. We determine the ionization frequency from the 5S{sub 1/2}(F=1) ground state of {sup 87}Rb to 1010.029 164 6(3)THz, providing the binding energy of the ground state with an accuracy improved by two orders of magnitude.

74 ATOMIC AND MOLECULAR PHYSICS↗

Enhanced Inertial Support: Modeling Fast Frequency Response Controls for Energy Storage System Inverters

Reduction of power system inertia is a growing concern for grid operators given the transition under way from conventional fossil generators to inverter-based resources. One key concern is the rapid and severe dip in power system frequency following a large disturbance which could trigger remedial actions including operation of under frequency load shedding (UFLS) relays. A potential solution is to utilize battery energy storage systems (BESS) to provide fast frequency response(FFR) to mitigate the system frequency impact of low system inertia. In this work, we investigate different control parameters to achieve modeled FFR response from BESS in the simulated US Western Interconnection. First, a very low inertia model is developed from an existing positive sequence model of the Western Interconnection. Afterwards, we tune the BESS dynamic response parameters to eliminate any risks of reaching UFLS relay thresholds following the loss of large generators. Finally, we investigate the relative impact of having large BESS units in comparison of multiple smaller units in the same area. The results of the analyses indicate that 1 GW of transmission-connected BESS can help mitigate the frequency drop caused by large generators outages in the Western Interconnection, and significantly reduce the risk of under frequency load shedding.

power system dynamic performance, Low Inertia, Fas↗

Rapid Active Power Control of Photovoltaic Systems for Grid Frequency Support

As deployment of power electronic coupled generation such as photovoltaic (PV) systems increases, grid operators have shown increasing interest in calling on inverter-coupled generation to help mitigate frequency contingency events by rapidly surging active power into the grid. When responding to contingency events, the faster the active power is provided, the more effective it may be for arresting the frequency event. This paper proposes a predictive PV inverter control method for very fast and accurate control of active power. This rapid active power control method will increase the effectiveness of various higher-level controls designed to mitigate grid frequency contingency events, including fast power-frequency droop, inertia emulation, and fast frequency response, without the need for energy storage. The rapid active power control method, coupled with a maximum power point estimation method, is implemented in a prototype PV inverter connected to a PV array. The prototype inverter's response to various frequency events is experimentally confirmed to be fast (beginning within 2 line cycles and completing within 4.5 line cycles of a severe test event) and accurate (below 2% steady-state error).

14 SOLAR ENERGY↗

Transmission-Distribution Dynamic Co-Simulation of Electric Vehicles Providing Grid Frequency Response

This paper investigates the impacts of electric vehicles (EVs) on power system frequency regulation based on an open-source transmission-and-distribution (T&D) dynamic co-simulation framework. The development of a EV dynamic model based on appropriate WECC dynamic model is introduced first, then the T&D dynamic co-simulation platform is described. The advantage of the overall platform is that DERs such as distributed photovoltaic (DPV) and EV are modeled explicitly in both transmission and distribution simulators for frequency dynamics and voltage, respectively. In the case studies, EVs frequency responses (i.e., primary and/or secondary) are simulated after the system is exposed to N-1 contingency such as a generation trip. Various EV frequency regulation participation strategies are investigated as well to study their impacts on system frequency response. The studies shows that EVs have potential capability to provide effective frequency regulation services.

electric vehicle↗

Experimental Demonstration of Frequency Regulation by Commercial Buildings – Part II: Results and Performance Evaluation

This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. We developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control and frequency regulation in Part I. In Part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation, and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland Power Market (PJM) very accurately. In addition, we discuss potential effects of frequency regulation on building operation (e.g., increase in energy consumption, oscillations in supply air temperature, and effect on chiller cycling), and provide suggestions for real-world implementation projects. Lastly, our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frequency Event Categorization in Power Distribution Systems Using Micro PMU Measurements

Frequency is an important metric for power stability. To enhance the situational awareness in power distribution systems, this article proposes a data-driven approach that utilizes the data from micro phasor measurement units (μPMU) to categorize frequency events observed in distribution feeders. The proposed approach has three layers, each of which analyzes if a frequency event is propagated from the transmission system, formed inside a distribution feeder or falsely produced by instantaneous frequency (IF) estimation algorithms, respectively. In the first layer, the Granger causality is utilized to compare the causal relations from measurements across different locations to decide if an event is propagated from the transmission side. In the second layer, a trained sparse coding dictionary is utilized to unmix the physical causes of a frequency event. In the third layer, a moving z-score based event-pair detector is applied to identify if a frequency event is algorithm-induced. The proposed approach is tested using the μPMU measurements collected from Lawrence Berkeley National Laboratory (LBNL) and Riverside Public Utility (RPU).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sizing SiC Storage Inverters for Fast Grid Frequency Support

As wind and solar displace synchronous generators whose inertia stabilizes the AC grid frequency on fast time scales, it has been proposed to use energy storage systems (ESSs) to mitigate frequency transient events. Such events require a rapid surge of power from the ESS, but they occur only rarely. The high temperature tolerance of SiC MOSFETs and diodes presents an opportunity for innovative ESS inverter designs. Herein we investigate a SiC ESS inverter design such that the SiC device ratings are obeyed during mild frequency events but are exceeded during rare, major events, for a potentially more economical inverter design. In support of this proposal we present: 1. An analysis of four years of grid frequency events in the U.S. Western Interconnection. 2. A switch-level ESS inverter simulation using SiC devices with detailed loss estimates. 3. Thermal analysis of the SiC power modules during a worst-case frequency event, showing that the modules can likely withstand the brief overcurrent. This analysis supports the conclusion that it may be advantageous for economical designs (acknowledging the increased risks) to undersize the SiC switches when designing inverters to perform active power control for grid frequency support. Such a strategy may result in SiC-based designs being more competitive with less costly silicon IGBT-based designs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Universal Frequency Dependence of the Hopping AC Conductance in p-Ge/GeSi Structures in the Integer Quantum Hall Effect Regime

The hopping ac conductance, which is realized at the transverse conductance minima in the regime of the integer Hall effect, has been measured using a combination of acoustic and microwave methods. Measurements have been made in the p-GeSi/Ge/GeSi structures with quantum wells in a wide frequency range (30–1200 MHz). The experimental frequency dependences of the real part of ac conductance σ{sub 1} have been interpreted on the basis of the model presuming hops between localized electronic states belonging to isolated clusters. At high frequencies, dominating clusters are pairs of close states; upon a decrease in frequency, large clusters that merge into an infinite percolation cluster as the frequency tends to zero become important. In this case, the frequency dependences of the ac conductance can be represented by a universal curve. The scaling parameters and their magnetic-field dependence have been determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Nonuniversality of the Frequency Dependence of the Conductivity in Disordered Nanogranulated Systems

The real part of the high-frequency phononless conductivity is calculated in the pair approximation for a disordered array of densely packed spherical nanogranules. The generalization of the theory of phononless conductivity for systems with point impurities to systems with localized finite sizes (arrays of nanogranules or quantum dots) reveals that the high-frequency conductivity depends on the distribution function of the distances between the surfaces of granules P(w). This is expected to cause the discrepancy of the real part of the conductivity σ{sub 1}(ω) from the linear frequency dependence. In the vicinity of the frequency ω ~ ω{sub c} = 2I{sub 0}/ℏ (here I{sub 0} is a preexponential factor of the resonance integral) for disordered granulated systems is likely to deviate from the universality σ{sub 1}(ω) ~ ω{sup s} (s ≈ 1) due to the attenuation of the frequency dependence σ{sub 1}(ω) of the conductivity and its nonmonotonicity. The nonmonotonicity of σ{sub 1}(ω) must arise at lower frequencies as a result of decreased preexponential factor I{sub 0} of the resonance integral with increasing granule size.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Stabilization of a self-referenced, prism-based, Cr:forsterite laser frequency comb using an intracavity prism

The frequency comb from a prism-based Cr:forsterite laser has been frequency stabilized using intracavity prism insertion and pump power modulation. Absolute frequency measurements of a CW fiber laser stabilized to the P(13) transition of acetylene demonstrate a fractional instability of {approx}2x10{sup -11} at a 1 s gate time, limited by a commercial Global Positioning System (GPS)-disciplined rubidium oscillator. Additionally, absolute frequency measurements made simultaneously using a second frequency comb indicate relative instabilities of 3x10{sup -12} for both combs for a 1 s gate time. Estimations of the carrier-envelope offset frequency linewidth based on relative intensity noise and the response dynamics of the carrier-envelope offset to pump power changes confirm the observed linewidths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency Instability Problems in North American Interconnections

Alternating current power transmission and distribution systems in the United States operate at a nominal (target) frequency of 60 Hz. Large deviations from this frequency can cause network instability, and even small deviations can adversely affect sensitive end-use devices. Frequency deviations commonly result from a mismatch between energy supply and demand on a power network. If supply is insufficient to meet demand, the system frequency will decrease; if supply exceeds demand, frequency will increase. Over 100 balancing authorities within four electrical interconnections in North America manage power flows so that frequency will remain stable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Domain Reflectometry (FDR) Simulation Techniques for Digital Twin Representation of an Electrical Cable

Simulation of cable system response to frequency domain reflectometry (FDR) tests can be instrumental to understanding these tests and the nature and influence of various cable anomalies on test signatures. Reflectometry simulations are based upon a finite element representation of cable conductors and insulation to produce an S-parameter at each evaluated frequency. The aggregate collection of cable model S-parameters can simulate the influence on a test signal injected into a physical cable. Such an approach was undertaken in this work to produce a digital twin simulation of a low-voltage electrical cable. The electrical cable digital twin examined the influence of test simulation parameters and the relative influence of cable anomalies, including thermal aging, water or moisture exposure, water or moisture ingress, and other anomalies. The digital twin in this work included modeling of the conductors, insulation, jacket, and surrounding environment (air, water, etc.). The digital twin could be expanded to include cable bends, junctions and splices, branch or T systems, and termination impedances of motors or instruments. Observations and conclusions of this work include: 1. Fully 3D digital twin simulation of an electrical cable using an FDR approach is possible. However, there are tradeoffs between simulation fidelity and solution time, which must be balanced to ensure the simulation solves in an adequate amount of time (e.g., less than 20 minutes). Simulation parameters to balance include frequency bandwidth, number of frequencies, mesh density, connection impedance, and permittivity tolerance. 2. The digital twin simulation can explain FDR sensitivity to various cable anomalies, including entry and exit from an oven or water bath. 3. The digital twin simulation FDR response attenuates with distance along the cable and is further affected by the frequency bandwidth, which is similar to that observed with physical measurements. 4. The resolution of the digital twin FDR peaks increased with increasing bandwidth and with increasing number of frequencies, again similar to physical measurements. 5. The presence of multiple anomalies in the digital twin does not substantially attenuate the FDR response to anomalies located beyond the first encountered anomaly and impedance mismatch. 6. Spectral variation of the permittivity did not have a significant effect on the FDR response compared to a fixed nominal value. 7. Extension of the digital twin to 1000 ft still allowed for detection of distal anomalies near the far end of the electrical cable from the instrument connection point. 8. The ARENA test bed facilitates efficient NDE evaluations of well understood cable anomalies with various NDE methods without risking actual plant damage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HIGH-PRECISION ASTROMETRIC MILLIMETER VERY LONG BASELINE INTERFEROMETRY USING A NEW METHOD FOR MULTI-FREQUENCY CALIBRATION

In this paper we describe a new approach for millimeter Very Long Baseline Interferometry (mm-VLBI) calibration that provides bona-fide astrometric alignment of the millimeter-wavelength images from a single source, for the measurement of frequency-dependent effects, such as “core-shifts” near the black hole of active galactic nucleus jets. We achieve our astrometric alignment by solving first for the ionospheric (dispersive) contributions using wide-band centimeter-wavelength observations. Second, we solve for the tropospheric (non-dispersive) contributions by using fast frequency-switching at the target millimeter-wavelengths. These solutions can be scaled and transferred from low frequency to the high frequency. To complete the calibration chain an additional step is required to remove a residual constant phase offset on each antenna. The result is an astrometric calibration and the measurement of the core-shift between 22 and 43 GHz for the jet in BL Lacertae to be −8 ± 5, 20 ± 6 μ as, in R.A. and decl., respectively. By comparison to conventional phase referencing at centimeter-wavelengths we are able to show that this core shift at millimeter-wavelengths is significantly less than what would be predicted by extrapolating the low-frequency result, which closely followed the predictions of the Blandford and Königl conical jet model. As such it would be the first demonstration for the association of the VLBI core with a recollimation shock, normally hidden at low frequencies due to the optical depth, which could be responsible for the γ -ray production in blazar jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Path Attenuation Estimates for the GPM Dual-Frequency Precipitation Radar (DPR)

Estimation of path attenuation is a critical part of retrieving precipitation parameters using measurements from the Dual-Frequency Precipitation Radar (DPR) on board the Global Precipitation Measurement Mission (GPM) satellite. In this paper, we describe the latest implementation of the Surface Reference Technique that uses surface scattering properties to infer path attenuation through the precipitation. Both single- and dual-frequency versions of this method are available and while the dual-frequency version appears to be more accurate at moderate rain rates, the single-frequency approach at Ku-band is needed when the Ka-band data are not available. Despite improvements afforded by the dual-frequency version of the method, other methods such as the Hitschfeld-Bordan and standard dual-frequency approaches offer advantages particularly at lighter rain rates and at near-nadir incidence angles over land. Weighted averages of the results from these methods appear to offer the best estimate of path attenuation presently available.

attenuation↗

Modeling Electro-Optic Frequency Comb Generation as a Pump Source for Quantum Communications

The Quantum Communications group at NASA GRC is focused on developing technologies and system architectures to enable future space-based quantum networks. High-repetition rate pulsed pump lasers are needed because the signal on the quantum channel cannot be amplified, hence entanglement generation rates can only be increased through high-rate pumping. Additionally, tunability in center frequency, pulse width, and repetition rate allows for a wider parameter space over which to optimize quantum channel frequency conversion efficiency, joint spectral engineering, and channel synchronization for high-fidelity entanglement swapping –a necessary stepping-stone towards quantum repeater development. One of the most flexible methods for high-repetition rate pulse generation is through spectral shaping–generating a frequency comb from a continuous-wave(CW)laser using electro-optic modulators (EOMs). As a result, this project focuses on analytically modeling and simulating the effects various EOMs such as phase and intensity modulators have on a CW source. Generating a tunable frequency comb as the pump source allows us to conveniently fine-tune the central frequency, repetition rate, and the spectral shape of our source to match the strict optimal parameters for any given entanglement source considered in the future. These models and simulations are to be used for comparison purposes for future experiments as well as for providing the Quantum Communications group a convenient tool to understand the effects of manipulating various parameters have on the outgoing frequency comb.

Electro-optic modulator↗

Effects of Long Duration Space Flight on Low Frequency Hearing

Pure tone hearing threshold data has been collected on astronauts since the early days of spaceflight. Between 1981 and 2001 (STS-1 thru 108) it was found that of the 608 shuttle astronauts, 17% returned home with a significant hearing threshold shift, and of that 6% had permanent changes in the high frequencies. Believed to be due to prolonged noise exposure on the space crafts. (Hart, 2006) As NASA aimed for longer duration missions the uncertainty about the effects of month-long noise exposure needed to be addressed. To avoid constraining crewmembers to constant earplug usage, and satisfying budget demands, a focused effort on overcoming the issues began. Noise monitoring systems were introduced onto the International Space Station (ISS) and astronauts were given education on the noise environment aboard the ISS, the hazards of noise induced hearing loss, hearing conservation principles, and countermeasure strategies (earplugs, noise cancellation headsets). As well as being trained on a new countermeasure effort that had been in trial testing on prior shuttle missions (STS-6 thru 8), On-Orbit Hearing Assessment (OOHA). (Hart, 2006) OOHA was implemented to routinely monitor the hearing thresholds of crewmembers who are on orbit for longer than 30 days. Flight Surgeons on ground monitor these test for significant hearing changes while aboard. Between 2000 and 2021 the ISS OOHA system (EarQ) recorded changes in the low frequency hearing thresholds. Low frequency hearing changes are not typically caused by noise exposure, and it was initially believed that these changes were due to environmental noise interference. In 2021 an ISS software upgrade (KUDUwave) allowed for a more comprehensive hearing assessment. The new testing system allowed for additional tests that helped describe the type of hearing loss being experienced and determine the influence of ambient noise or other environmental factors. OOHA Data indicates a low frequency hearing shift in 40% of all tests and 60% of all crewmembers. Since 2021, OOHA results (using the KUDUwave) suggest that these shifts are sensorineural and are not the result of ambient noise. While hearing shifts are seen at both 250 and 500 Hz, metrics tracking these shifts have only used 500 Hz data. The lack of 250 Hz has prevented accurate reporting of low frequency hearing shift recovery. The aim of this study is to capture 250 Hz data and accurately present low frequency hearing loss recovery.

hearing↗

The Benefits of Using Time-Frequency Analysis with Synthetic Aperture Focusing Technique

Improvements in detection and resolution are always desired and needed. There are various instruments available for the inspection of concrete structures that can be used with confidence for detecting different defects. However, more often than not that confidence is heavily dependent on the experience of the operator rather than the clear, objective discernibility of the output of the instrument. The challenge of objective discernment is amplified when the concrete structures contain multiple layers of reinforcement, are of significant thickness, or both, such as concrete structures in nuclear power plants. We seek to improve and extend the usefulness of results produced using the synthetic aperture focusing technique (SAFT) on data collected from thick, complex concrete structures. A secondary goal is to improve existing SAFT results, with regards to repeatedly and objectively identifying defects and/or internal structure of concrete structures. Towards these goals, we are applying the time-frequency technique of wavelet packet decomposition and reconstruction using a mother wavelet that possesses the exact reconstruction property. However, instead of analyzing the coefficients of each decomposition node, we select and reconstruct specific nodes based on the frequency band it contains to produce a frequency band specific time-series representation. SAFT is then applied to these frequency specific reconstructions allowing SAFT to be used to visualize the reflectivity of a frequency band and that band s interaction with the contents of the concrete structure. We apply our technique to data sets collected using a commercial, ultrasonic linear array (MIRA) from two 1.5m x 2m x 25cm concrete test specimens. One specimen contains multiple layers of rebar. The other contains honeycomb, crack, and rebar bonding defect analogs. This approach opens up a multitude of possibilities for improved detection, readability, and overall improved objectivity. We will focus on improved defect/reinforcement isolation in thick and multilayered reinforcement environments. Additionally, the ability to empirically explore the possibility of a frequency-band-defect-type relationship or sensitivity becomes available.

concrete NDE↗