Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

LSST Undergraduate Internships at Fermilab

Fermi National Accelerator Laboratory (Fermilab) plans to leverage the laboratory’s long tradition of hosting internships in high-energy physics and cosmology by setting up a mentoring laboratory program for undergraduate students to study data and model driven Large Synoptic Survey Telescope (LSST) science at the laboratory’s Center for Particle Astrophysics. The laboratory program will form an intern group that will explore the science of combining of LSST analysis using DC2 simulations and CosmoSIS modeling. Interns will be empowered to learn from each other while under the supervision of experienced cosmic frontier scientists, a model that has been successful in the laboratory setting. In addition, many of these undergraduate interns will form future candidate graduate student classes

79 ASTRONOMY AND ASTROPHYSICS↗

Status of Scintillator Development at Fermilab

Fermilab has had a 20+ year history in producing scintillator and is now one of the largest producers of organic scintillator in the world. Its scintillator has been used in a wide variety of applications including archeology, volcanology, mining exploration, agriculture, national security, as well as more traditional applications in HEP and Astro-particle physics. We will survey these applications. We have a scintillator extrusion facility and recently we have added injection molding capacity. We will discuss ongoing and near-term future projects for these facilities. We discuss ongoing R&D to improve light yield and timing performance of the extruded scintillator and hence reduce cost. We will discuss methods to improve light yield of injection-molded scintillator by refinements in the scintillator chemistry and process. Finally, we will present longer-term future plans for making new scintillating materials tailored for specific applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Combined Function Magnets for the Fermilab PIP-II Booster Upgrade

The Proton Improvement Plan II (PIP-II) is an enhancement to the Fermilab accelerator complex enabling a high intensity proton beam to support the laboratory’s experiments. The heart of PIP-II is a superconducting linac which will increase the injection energy in the booster from the existing 400 MeV to 800 MeV. To make room for the modified injection into the booster, two shorter defocusing gradient magnets have been designed. Two wide aperture defocusing gradient magnets have also been designed to go on either side of the extraction septa to reduce extractions losses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress on an Electron Beam Profile Monitor at the Fermilab Main Injector

The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with other planned improvements, is in support of proton beam intensities in the Main Injector (MI) that will exceed 2 MW. Measuring the transverse profiles of these high intensity beams in a ring requires non-invasive techniques. The MI uses ionization profile monitors as its only profile system. An alternative technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. This type of device was installed in MI and initial studies of it have been previously presented. This paper will present the status and recent studies of the device utilizing different techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Current Status of the High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (FNAL) and Lawrence Berkeley National Laboratory (LBNL) are collaborating to construct a new High Field Vertical Magnet Test Facility (HFVMTF) designed for testing superconducting cables in high magnetic fields. This state-of-the-art facility will be situated at Fermilab and will provide capabilities comparable to EDIPO at PSI and FRESCA2 at CERN. The HFVMTF’s background magnetic field, reaching 15 T, will be generated by a magnet supplied by LBNL. The HFVMTF is a collaborative effort supported by the US DOE Offices of Science, High Energy Physics, and Fusion Energy Sciences. It will serve as a vital testbed for superconducting HTS cables, subjecting them to high magnetic fields and a wide range of temperatures, benefiting both scientific communities. Additionally, this facility will play a key role in testing high-field superconducting magnet models and demonstrators, including hybrid magnets, developed by the US Magnet Development Pro gram (MDP). These hybrid magnets, utilizing both LTS and HTS superconductors, are significant advancements toward achieving 18+ T dipoles for future hadron-hadron colliders. The presentation outlines the current status of the facility, covering aspects such as construction progress, cryostat designs, top and lambda plates, and systems for powering, quench protection, and monitoring.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scheme for quantitative description of longitudinal drifts in the Fermilab Linac and their correction

The Fermilab Linac accepts the 0.75 MeV H- ions from the front end and accelerates them to 400 MeV for injection into the Booster. Day-to-day drifts of the longitudinal trajectory in the Linac, reconstructed from phase readings of Beam Position Monitors, are at the level of several degrees. They are believed to cause additional losses both in the Linac and Booster, and are addressed by empirically adjusting the phases of Linac cavities. This work explores the option of expressing these drifts in terms of phase shifts in two cavities at the low-energy part of the Linac. Such a description allows for a simplified visual representation of the drifts, suggests a clear algorithm for their compensation, and provides a tool for estimating efficiency of such compensation.

43 PARTICLE ACCELERATORS↗

State of Rucio at Fermilab

Annual presentation regarding the usage of the Rucio data management software at Fermilab.

White, Brandon↗

Space Charge Dominated Momentum Spread and Compensation Strategies in the Post-Linac Section of Proton Improvement Plan-II at Fermilab

The upcoming Proton Improvement Plan-II (PIP-II), designated for enhancements to the Fermilab accelerator complex, features a Beam Transfer Line (BTL) that channels the beam from the linac exit to the booster. In the absence of longitudinal focusing beyond the superconducting linac, the beam experiences an elevated momentum spread, primarily due to nonlinear space-charge forces, surpassing the allowable limit of 2.1e-4. This study presents a detailed examination of the space-charge-induced momentum spread and outlines mitigative strategies. The investigation includes the fine-tuning of a de-buncher cavity, analyzed in terms of operating frequency, longitudinal location, and gap voltage, under both standard and perturbed beam conditions—specifically accounting for momentum jitter and energy variation. The impact of buncher cavity misalignments on the beam's longitudinal phase space is also assessed. The paper concludes by recommending an optimized cavity configuration to effectively mitigate the observed increase in momentum spread along the BTL.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Physics Design of Proton Improvement Plan-II at Fermilab

This paper presents the final physics design of the Proton Improvement Plan-II (PIP-II) at Fermilab, focusing on the linear accelerator (Linac) and its beam transfer line. We address the challenges in longitudinal and transverse lattice design, specifically targeting collective effects, parametric resonances, and space charge nonlinearities that impact beam stability and emittance control. The strategies implemented effectively mitigate space charge complexities, resulting in significant improvements in beam quality—evidenced by reduced emittance growth, lower beam halo, decreased loss, and better energy spread management. This comprehensive study is pivotal for the PIP-II project's success, providing valuable insights and approaches for future accelerator designs, especially in managing nonlinearities and enhancing beam dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative Description and Correction of Longitudinal Drifts in the Fermilab Linac

The Fermilab Linac accepts the 0.75 MeV H- ions from the front end and accelerates them to 400 MeV for injection into the Booster. Day-to-day drifts of the longitudinal trajectory in the Linac, reconstructed from phase readings of Beam Position Monitors, are at the level of several degrees. They are believed to cause additional losses both in the Linac and Booster, and are addressed by empirically adjusting the phases of Linac cavities. This work explores the option of expressing these drifts in terms of phase shifts in two cavities at the low-energy part of the Linac. Such description allows for a simplified visual representation of the drifts, suggest a clear algorithm for their compensation, and provides a tool for estimating efficiency of such compensation.

43 PARTICLE ACCELERATORS↗

Cosmic Background Rejection of the ICARUS experiment at Fermilab

The Short Baseline Neutrino program at Fermilab aims to explore significant regions of parameter space, applicable to sterile neutrinos at the eV mass scale, as suggested by existing experimental anomalies. To this purpose it exploits Liquid Argon Time Projection Chamber detectors located along the Booster Neutrino Beamline to measure both νe appearance and νµ disappearance: the Short Baseline Neutrino Detector and the ICARUS-T600 detector at 110 and 600 m from the neutrino source, respectively. The ICARUS T-600 Far Detector, located at shallow depth, is surrounded by a Cosmic Ray Tagger system to mitigate the cosmic ray background. On average ~ 11 muon tracks are expected to cross the detector during the ~ 1 ms drift time. The cosmic ray tagger is composed of plastic scintillator bars, ensuring near 4π coverage of the detector aiming at tagging cosmic muons and thus reject 𝛾s produced by muon interactions in the surrounding materials that can generate an electromagnetic showers mimicking a νe signal. The system allows one to disentangle cosmic rays from particles originated in a neutrino interaction inside the detector by measuring their position and crossing time. A synchronization of the cosmic ray tagger with the ICARUS photon detection system with a nanosecond accuracy allows one to reject cosmic particles recorded during the beam spill and thus select an enriched sample of neutrino triggered events ahead of the event reconstruction. An overview of the cosmic ray tagger system as well as its role in the neutrino events identification and cosmic background rejection will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated Simulation of PIP-II at Fermilab

We describe progress towards a community software ecosystem for efficient modeling of the Fermilab PIP-II complex for design validation and virtual test stands.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication status of production SSR1 jacketed cavities for PIP-II at Fermilab

This paper provides an overview of the current fabrication status of superconducting SSR1 spoke cavities intended for integration into the PIP-II SRF linac at Fermilab. It explores the ongoing development and fabrication processes of the jacketed SSR1 cavity, highlighting key modifications made in the mechanical design to enhance structural integrity.

Aiazzi, T.↗

Performance of the Fermilab Linac Injector

The Fermilab Linac injection line consists of a 35 keV magnetron-type H- ion source, two-solenoid Low Energy Beam Transport (LEBT), 201 MHz 4-rod 750 keV Radio Frequency Quadrupole (RFQ), and a Medium Energy Transport (MEBT) containing 4 quadrupoles and a bunching cavity. The injector delivers 25 mA, 48 s pulses to drift-tube Linac at a repetition rate of 15Hz. The transmission efficiency has been lower than expected since commissioning. Recent beam current measurements suggest that the beam is primarily lost upstream of the RFQ exit. Numerical simulations indicate that ions passing through the non-linear field region of the solenoids could produce a beam with an increased emittance resulting in up to 50 % of the LEBT beam current failing to meet the RFQ acceptance. An aperture restriction was installed upstream of the first solenoid to remove these ions. This report describes the results of measurements and simulations as well as the LEBT tuning.

Jones, Daniel C.↗