Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

U.S. Department of Energy Portsmouth Annual Site Environmental Report (ASER) for 2012. Student Summary

The report that follows is a summary of the U.S. Department of Energy Portsmouth Annual Site Environmental Report for 2012 (ASER), regarding PORTS located near Piketon, Ohio. The summary has been compiled by the 2015 WHS Environmental Science class, made up of juniors and seniors at WHS during the 2014-2015 school year. Even with most of the class having lived in this region for their entire lives, it became apparent how little of the workings of the plant were known by the members of the class. In the process of putting this summary together, we were able to gain a better understanding of the history, function, and possible future of the site. The presentations provided by Ohio University, Fluor-B&W Portsmouth LLC (FBP), U.S. DOE, and Rio Grande University were greatly appreciated and provided invaluable understanding of the materials which we were asked to summarize. Not only did we learn from the presentations, but we greatly enjoyed the opportunities to participate in the field studies that gave us a glimpse into what is being done at the plant site to ensure the environmental safety of people and wildlife of this region. Our goal from this summary has been to make the information concerning the monitoring and cleanup of the PORTS facility better understood by the people who it most affects. We hope that this summary makes the information useful to you and that you can gain a better understanding of the cleanup processes that are going on around the site to ensure your safety. Though it has been hard work, we appreciate the opportunity that we have been presented with to learn and share with the people of our community.

54 ENVIRONMENTAL SCIENCES↗

Field Demonstration of Ground-Source Integrated Heat Pump Part I. Technology and Field Demo System/Site Descriptions, and Preliminary Summer/Fall Performance Analysis for One Site

The field study is planned to continue through the 2016 cooling season with the draft final project report due by September 30, 2016. This report provides a description of both installations and preliminary 2015 cooling and fall season performance results for the Knoxville site. For the August 18 through December 14 period, the Knoxville site GS-IHP provided 53.6% total source energy savings compared to a baseline electric RTU/heat pump and electric WH. Peak demand savings ranged from 33% to 59% per month. Energy cost savings of 53.1% have been achieved to date with more than half of that coming from reduced demand charges. Data on installation and maintenance costs are being collected and will be combined with total test period energy savings data for a payback analysis to be included in the project final report. The GS-IHP also saved a significant amount of carbon emissions. The total emission savings for the Knoxville site for the August-December 2015 period were ~0.8 metric tons. If trading for carbon credits ever becomes a reality, additional cost savings would be realized.

20 FOSSIL-FUELED POWER PLANTS↗

Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window and door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Cultivation Data from the Algae Testbed Public Private Partnership as Utilized in NREL's Algae State of Technology Assessments

The Algae Testbed Public Private Partnership (ATP3) conducted algal growth experiments over the course of 16 months termed the Unified Field Studies (UFS). These experiments were conducted at 5 different geographic locations in Arizona (ASU), California (CP), Florida (FA), Georgia (GT), and Hawaii (CELL). The UFS sought to evaluate different algal biomass harvesting strategies using identical ponds, media, and operational conditions through all four seasons across different geographic regions to isolate the effects on productivity attributed to locational climate and seasonal variability, overlaid by the differing harvest strategies. Set up as the baseline against which other experiments would build upon, it must be emphasized that as per the stated, approved experimental goals of the ATP3 UFS, no attempts at growth or lipid accumulation optimization were made; rather, the primary focus of the UFS work was to cultivate algal biomass under deliberate, consistent conditions, time periods, and harvesting protocols, to provide public data on year-round outdoor biomass production that could be directly compared between one site and another (with accompanying climate data for each site). Thus the resulting productivity numbers in effect represent a conservative baseline of non-optimized algal growth one may expect at these sites. Also clearly weather can vary dramatically from season to season and from year to year, and even within a given 'season' where an individual season's data was typically based on 4-6 week operating windows. Thus these numbers also only reflect a short snapshot in time, and must be interpreted carefully in projecting what may be expected over many years or decades (for example, a 30-year facility lifetime as evaluated in techno-economic models).

09 BIOMASS FUELS↗

Healthy Efficient New Gas Homes (HENGH) Pilot Test Results

The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The other home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Evaluation of SSL Field Performance in Select Interior Projects

This GATEWAY project evaluated four field installations to better understand the long-term performance of a number of LED products, which can hopefully stimulate improvements in designing, manufacturing, specifying, procuring, and installing LED products. Field studies provide the opportunity to discover and investigate issues that cannot be simulated or uncovered in a laboratory, but the installed performance over time of commercially available LED products has not been well documented. Improving long-term performance can provide both direct energy savings by reducing the need to over-light to account for light loss and indirect energy savings through better market penetration due to SSL’s competitive advantages over less-efficient light source technologies. The projects evaluated for this report illustrate that SSL use is often motivated by advantages other than energy savings, including maintenance savings, easier integration with control systems, and improved lighting quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summer Indoor Heat Pump Water Heater Evaluation in a Hot-Dry Climate

Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summer Indoor Heat Pump Water Heater Evaluation in a Hot-Dry Climate

Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Annual Status Report (FY2016) Performance Assessment for the Environmental Restoration Disposal Facility

DOE O 435.1, Radioactive Waste Management, and DOE M 435.1-1, Radioactive Waste Management Manual, require that a determination of continued adequacy of the performance assessment (PA), composite analysis (CA), and disposal authorization statement (DAS) be made on an annual basis, and it must consider the results of data collection and analysis from research, field studies, and monitoring. Annual summaries of low-level waste (LLW) disposal operations must be prepared with respect to the conclusions and recommendations of the PA and CA, and a determination of the need to revise the PA or CA must be made. The annual summary requirement provides a structured approach for demonstrating the continued adequacy of the PA and CA in demonstrating a reasonable expectation that the performance objectives will be met. This annual summary addresses only the status of the Environmental Restoration Disposal Facility (ERDF) PA (CP-60089, Performance Assessment for the Environmental Restoration Disposal Facility, Hanford Site, Washington, formerly WCH-520 Rev. 1)1. The CA for ERDF is supported by DOE/RL-2016-62, Annual Status Report (FY 2016): Composite Analysis of Low Level Waste Disposal in the Central Plateau at the Hanford Site. The ERDF PA portion of the CA document is found in Section 3.1.4, and the ERDF operations portion is found in Section 3.3.3.2 of that document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology Assessments of High Performance Envelope with Optimized Lighting, Solar Control, and Daylighting

The objective of this monitored field study was to identify near-term innovative façade technologies for solar control and daylighting with a goal of 20-40% energy use savings below Title 24 2013 in the 30-ft deep perimeter zone near vertical windows within cost and comfort constraints. The targeted market was new or existing commercial office buildings or buildings with similar patterns of use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Annual Status Report (FY2017): Performance Assessment for the Environmental Restoration Disposal Facility

In accordance with U.S. Department of Energy (DOE) requirements in DOE O 435.1 Chg 11 and DOE M 435.1-1 Chg 1,2 a determination of continued adequacy of the performance assessment (PA), composite analysis (CA), and disposal authorization statement (DAS) is required on an annual basis. This determination must consider the results of data collection and analysis from research, field studies, and monitoring.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computed Tomography Scanning and Geophysical Measurements of Core from the Marcellus Shale Energy and Environment Laboratory

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize middle Devonian black shale from the Marcellus Shale Energy and Environmental Laboratory (MSEEL) site in northeastern West Virginia. The samples are representative of the Middle Devonian Marcellus Formation, a clay-rich black shale in the Appalachian Basin. The MSEEL site is a unique field study area for new techniques supporting natural gas production and a high level of monitoring of environmental impacts. The primary impetus of this work is a collaboration between NETL, West Virginia University, Northeast Natural Energy (NNE), and Ohio State University to characterize core from multiple wells to better understand the structure and variation of the Marcellus Shale formations. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis.

58 GEOSCIENCES↗

Annual Status Report (FY 2018): Performance Assessment for the Environmental Restoration Disposal Facility

DOE O 435.1 and DOE M 435.1-1 require that a determination of continued adequacy of the performance assessment (PA), composite analysis, and disposal authorization statement be made on an annual basis, and it must consider the results of data collection and analysis from research, field studies, and monitoring. Beginning in 1996, the Environmental Restoration Disposal Facility (ERDF) started accepting low-level radioactive, hazardous, and mixed wastes that were generated during cleanup activities at the Hanford Site. ERDF is composed of a series of cells or disposal areas and can accommodate future design expansions as needed. Currently, there are 10 cells. During this reporting period (fiscal year 2018, which extends from October 1, 2017, through September 30, 2018), approximately 193,358 U.S. tons of waste was disposed at ERDF. From ERDF inception through September 30, 2018, approximately 18.3 million U.S. tons of waste had been disposed at ERDF, which equates to consumption of approximately 87% of the disposal volume. As a condition of the Disoposal Authorization Statement, disposal operations within ERDF must be in accordance with the waste acceptance criteria (WAC) that provides specific radionuclide disposal limits, waste form restrictions, and descriptions of acceptable waste packages in compliance with the requirements of DOE 435-1.1. The ERDF WAC stipulates that waste destined for disposal at ERDF be controlled based on source, physical form, and contaminant concentration and activity levels. Concentration limits included in the ERDF WAC were extracted from the ERDF PA. A sum of fraction analysis of of the ERDF inventory against the threshold concentration limits from inception through fiscal year 2018 produces a result <1. This result provides confirmation of compliance with PA imposed radionuclide limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Instruction Manual: River Function Questionnaire

The River Function Questionnaire (Questionnaire) is a series of questions designed to help stakeholders determine the impacts of hydropower on a series of environmental indicators, i.e. river functions, that may need to be understood or addressed through additional field studies or environmental assessments. In order to provide a platform accessible to many users, the questionnaire was developed in Microsoft Excel with convenient macro-enabled interactive features. The Questionnaire was developed under the Department of Energy (DOE)-funded Environmental Metrics for Hydropower (EMH) project in FY 2018. This document provides an instruction manual that provides overall guidance and step-by-step instructions for use.

13 HYDRO ENERGY↗

Technology Summary DNATRAX

DNATrax (DNA Tagged Reagents for Aerosol eXperiments) was developed to provide a safe simulant for understanding the transport and dispersion of pathogens. Specifically, it was developed as a safe surrogate for the Bacillus anthrasis spore bioagent, since most naturally occurring spores are not safe for public release. As DNA-tagged sugar particles, DNATrax aerosols are safe for public release. Scientists can add unique DNA barcode sequences to the sugar particles to produce a wide variety of test particles that can be easily differentiated, making it possible to release and test them simultaneously. The unique barcodes also eliminate the need to conduct decontamination between tests, dramatically reducing the cost and time to run experiments. Additionally, the surrogate offers a high-sensitivity detection method to understand key public health issues. We conducted both lab-based and largescale field studies using DNATrax to validate its capabilities for use as a pathogen surrogate. We have demonstrated the ability to produce DNATrax in a range of sizes, adjusting the microparticles to simulate different sized pathogens with ability to create unique sequences of DNA bases, enabling them to create a nearly unlimited variety of test particles.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Assessment for the Environmental Restoration Disposal Facility (FY 2019 Annual Status Report)

DOE O 435.1 and DOE M 435.1-1 require that a determination of continued adequacy of the performance assessment (PA), composite analysis, and disposal authorization statement (DAS) be annually, and it must consider the results of data collection and analysis from research, field studies, and monitoring as well as update any Radioactive Waste Management Basis documents. Beginning in 1996, the Environmental Restoration Disposal Facility (ERDF) has accepted low-level radioactive, hazardous, and mixed wastes that were generated during cleanup activities at the Hanford Site. ERDF is composed of a series of cells (currently 10) or disposal areas and can accommodate future design expansions as needed. During this reporting period (fiscal year 2019, October 1, 2018, to September 30, 2019). approximately 139,721 U.S. tons of waste was disposed at ERDF. From inception through September 30, 2019, ERDF has received approximately 18.5 million U.S. tons of waste, which equates to consumption of approximately 88% of the disposal volume. As a condition of the DAS, disposal operations within ERDF must be in accordance with the waste acceptance criteria (WAC) that provide specific radionuclide disposal limits, waste from restrictions, and descriptions of acceptable waste packages in compliance with DOE M 435-1.1 requirements. The ERDF WAC stipulates that waste destined for disposal at ERDF be controlled based on source, physical form, and containment concentration and activity levels

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-Destructive Imaging of a Liquid Moving Through Porous Media Using a Computer Tomography Scanner

The most common approach used by modelers to describe movement of liquids through a porous solid, such as cement, sediment, or glass, is to assume a uniform flow rate, such as a Darcy Flux or a diffusion constant. However, this convenient simplification is problematic because in many cases it ignors the presence of fractures and macropores, which commonly dominate water flow and contaminant transport. For this reason, it is common that such modeling results do not reflect the multi-modal flow detected in laboratory and field studies. The objective of this seedling study was to develop a new capability for SRNL to track liquid moving through micro- (matrix-) and macro-flow using an X-ray Computed Topography (CT) Scanner. 4-dimensional anamated renditions were created that permited quantifying traditional matrix flow and macropore flow. These animations were modelled using a public domain software, HYDRUS 1-D, describing one dimension, dual-porosity and dual-permeability processes. This new capability provides a proof of concept for reducing model uncertainty applicable to waste disposal risk calculations, environmental remediation, and waste form development when describing the movement of liquids as they pass through glass, cement, fractured rock, or soil.

47 OTHER INSTRUMENTATION↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗