Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

FORMATION OF PLANETARY CORES AT TYPE I MIGRATION TRAPS

One of the long-standing unsolved problems of planet formation is how solid bodies of a few decimeters in size can 'stick' to form large planetesimals. This is known as the 'meter-size barrier'. In recent years, it has become increasingly clear that some form of 'particle trapping' must have played a role in overcoming the meter-size barrier. Particles can be trapped in long-lived local pressure maxima, such as those in anticyclonic vortices, zonal flows, or those believed to occur near ice lines or at dead zone boundaries. Such pressure traps are the ideal sites for the formation of planetesimals and small planetary embryos. Moreover, they likely produce large quantities of such bodies in a small region, making it likely that subsequent N-body evolution may lead to even larger planetary embryos. The goal of this Letter is to show that this indeed happens, and to study how efficient it is. In particular, we wish to find out if rocky/icy bodies as large as 10 M{sub +} can form within 1 Myr, since such bodies are the precursors of gas giant planets in the core accretion scenario.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sacramento Municipal Utility District PV and Smart Grid Pilot at Anatolia

Under DE-FOA-0000085 High Penetration Solar Deployment, the U. S. Department of Energy funded agreements with SMUD and Navigant Consulting, SunPower, GridPoint, the National Renewable Energy Laboratory, and the California Energy Commission for this pilot demonstration project. Funding was $5,962,409.00. Cost share of $500,000 was also provided by the California Energy Commission. The project has strategic implications for SMUD, other utilities and the PV and energy-storage industries in business and resource planning, technology deployment and asset management. These implications include: -At this point, no dominant business models have emerged and the industry is open for new ideas. -Demonstrated two business models for using distributed PV and energy storage, and brainstormed several dozen more, each with different pros and cons for SMUD, its customers and the industry. -Energy storage can be used to manage high penetrations of PV and mitigate potential issues such as reverse power flow, voltage control violations, power quality issues, increased wear and tear on utility equipment, and system wide power supply issues. - Smart meters are another tool utilities can use to manage high penetrations of PV. The necessary equipment and protocols exist, and the next step is to determine how to integrate the functionality with utility programs and what level of utility control is required. - Time-of-use rates for the residential customers who hosted energy storage systems did not cause a significant change in energy usage patterns. However, the rates we used were not optimized for PV and energy storage. Opportunities exist for utilities to develop new structures.

14 SOLAR ENERGY↗

Generalized photoclinometry for Mariner 9

A theory is developed for the photoclinometric determination of topography when the photometric function of a planetary surface is not restricted beyond the expectation that it is a function of phase angle, angle of incidence, and angle of emergence. Several versions of such an operational theory are presented together with several approaches to the numerical analysis. Reasons for the differences in numerical techniques are discussed. A preliminary result is considered which has been produced for an early Mariner 9 frame wherein the dust-laden atmosphere seems to exhibit standing-wave patterns. It is shown that if the assumption of homologous departures from plane-parallel atmospheric configuration is valid, the photoclinometry implies that laminar flow lines in the optically observable dust layer undergo a near-sinusoidal rise and fall of about 40 to 50 meters.

Wildey, R. L.↗

Local vertical motions and kinetic temperature from AE-C as evidence for aurora-induced gravity waves

In situ measurements of local vertical neutral particle motions have been made using the Neutral Atmosphere Temperature Instrument (NATE) on Atmosphere Explorer-C from observations of the direction of flow of neutral particles into the antechamber of the sensor (mass spectrometer). Values ranging from a few to more than 80 meters per second have been observed. The data show vertical motions greater than a few meters per second to be present most of the time, the magnitude being a function of many factors including magnetic activity, location, and magnetic storm history. In a specific case, it is concluded that the observed vertical motions and kinetic temperature are evidence of a travelling disturbance originating as a gravity wave in the auroral zone.

Spencer, N. W.↗

Coupled radiation effects in thermochemical nonequilibrium shock-capturing flowfield calculations

Lunar and Mars return conditions are examined using the LAURA flowfield code and the LORAN radiation code to assess the effect of radiative coupling on axisymmetric thermochemical nonequilibrium flows. Coupling of the two codes is achieved iteratively. Special treatment required to couple radiation in a shock-capturing method is discussed. Results indicate that while coupling effects are generally the same as occur in equilibrium flows, under certain conditions radiation can modify the chemical kinetics of a nonequilibrium flow and thus alter relaxation processes. Coupling effects are found to be small for all cases considered, except for a five meter diameter aerobrake returning from Mars at 13.6 km/sec.

Hartung, Lin C.↗

Aerodynamic characteristics and pressure distributions for an executive-jet baseline airfoil section

A wind tunnel test of an executive-jet baseline airfoil model was conducted in the adaptive-wall test section of the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel. The primary goal of the test was to measure airfoil aerodynamic characteristics over a wide range of flow conditions that encompass two design points. The two design Mach numbers were 0.654 and 0.735 with corresponding Reynolds numbers of 4.5 x 10(exp 6) and 8.9 x 10(exp 6) based on chord, respectively, and normal-force coefficients of 0.98 and 0.51, respectively. The tests were conducted over a Mach number range from 0.250 to 0.780 and a chord Reynolds number range from 3 x 10(exp 6) to 18 x 10(exp 6). The angle of attack was varied from -2 deg to a maximum below 10 deg with one exception in which the maximum was 14 deg for a Mach number of 0.250 at a chord Reynolds number of 4.5 x 10(exp 6). Boundary-layer transition was fixed at 5 percent of chord on both the upper and lower surfaces of the model for most of the test. The adaptive-wall test section had flexible top and bottom walls and rigid sidewalls. Wall interference was minimized by the movement of the adaptive walls, and the airfoil aerodynamic characteristics were corrected for any residual top and bottom wall interference.

Allison, Dennis O.↗

Scramjet Performance Assessment Using Water Absorption Diagnostics (U)

Simultaneous multiple path measurements of temperature and H2O concentration will be presented for the AIMHYE test entries in the NASA Ames 16-Inch Shock Tunnel. Monitoring the progress of high temperature chemical reactions that define scramjet combustor efficiencies is a task uniquely suited to nonintrusive optical diagnostics. One application strategy to overcome the many challenges and limitations of nonintrusive measurements is to use laser absorption spectroscopy coupled with optical fibers. Absorption spectroscopic techniques with rapidly tunable lasers are capable of making simultaneous measurements of mole fraction, temperature, pressure, and velocity. The scramjet water absorption diagnostic was used to measure combustor efficiency and was compared to thrust measurements using a nozzle force balance and integrated nozzle pressures to develop a direct technique for evaluating integrated scramjet performance. Tests were initially performed with a diode laser tuning over a water absorption feature at 1391.7 nm. A second diode laser later became available at a wavelength near 1343.3 nm covering an additional water absorption feature and was incorporated in the system for a two-wavelength technique. Both temperature and mole fraction can be inferred from the lineshape analysis using this approach. Additional high temperature spectroscopy research was conducted to reduce uncertainties in the scramjet application. The lasers are optical fiber coupled to ports at the combustor exit and in the nozzle region. The output from the two diode lasers were combined in a single fiber, and the resultant two-wavelength beam was subsequently split into four legs. Each leg was directed through 60 meters of optical fiber to four combustor exit locations for measurement of beam intensity after absorption by the water within the flow. Absorption results will be compared to 1D combustor analysis using RJPA and nozzle CFD computations as well as to data from a nozzle metric balance measuring thrust and integrated pressure measurements along the length of the nozzle. Assessment of its value as a combustor performance evaluation tool will be conducted.

Cavolowsky, John A.↗

Ion Species Fractions in the Far-Field Plume of a High-Specific Impulse Hall Thruster

An ExB probe was used to measure the ion species fractions of Xe(+), Xe(2+), and Xe(3+) in the far-field plume of the NASA-173Mv2 laboratory-model Hall thruster. The thruster was operated at a constant xenon flow rate of 10 milligrams per second and discharge voltages of 300 to 900 V. The ExB probe was placed two meters downstream of the thruster exit plane on the thruster centerline. At a discharge voltage of 300 V, the species fractions of Xe(2+) and Xe(3+) were lower, but still consistent with, previous Hall thruster studies using other mass analyzers. Over discharge voltages of 300 to 900 V, the Xe(2+) species fractions increased from 0.04 to 0.12 and the Xe(3+) species fraction increased from 0.01 to 0.02.

Hofer, Richard R.↗

Coupled Radiation Effects in Thermochemical Nonequilibrium Shock-Capturing Flowfield Calculations

Lunar and Mars return conditions are examined using the LAURA flow field code and the LORAN radiation code to assess the effect of radiative coupling on axisymmetric thermochemical nonequilibrium flows. Coupling of the two codes is achieved iteratively. Special treatment required to couple radiation in a shock-capturing method is discussed. Results indicate that while coupling effects are generally the same as occur in equilibrium flows, under certain conditions radiation can modify the chemical kinetics of a nonequilibrium flow and thus alter relaxation processes. Coupling effects are found to be small for all cases considered, except for a five meter diameter aerobrake returning from Mars at 13.6 kilometers per second.

Hartung, Lin C.↗

A Side by Side Comparison of Filter-Based PM(sub 2.5) Measurements at a Suburban Site: A Closure Study

Reliable determination of the effects of air quality on public health and the environment requires accurate measurement of PM(sub 2.5) mass and the individual chemical components of fine aerosols. This study seeks to evaluate PM(sub 2.5) measurements that are part of a newly established national network by comparing them with a more conventional sampling system. Experiments were carried out during 2002 at a suburban site in Maryland, United States, where two samplers from the U.S. Environmental Protection Agency (USEPA) Speciation Trends Network: Met One Speciation Air Sampling System STNS and Thermo Scientific Reference Ambient Air Sampler STNR, two Desert Research Institute Sequential Filter Samplers DRIF, and a continuous TEOM monitor (Thermo Scientific Tapered Element Oscillating Microbalance) were sampling air in parallel. These monitors differ not only in sampling configuration but also in protocol-specific sample analysis procedures. Measurements of PM(sub 2.5) mass and major contributing species were well correlated among the different methods with r-values > 0.8. Despite the good correlations, daily concentrations of PM(sub 2.5) mass and major contributing species were significantly different at the 95% confidence level from 5 to 100% of the time. Larger values of PM(sub 2.5) mass and individual species were generally reported from STNR and STNS. The January STNR average PM(sub 2.5) mass (8.8 (micro)g/per cubic meter) was 1.5 (micro)g/per cubic meter larger than the DRIF average mass. The July STNS average PM(sub 2.5) mass (27.8 (micro)g/per cubic meter) was 3.8 (micro)g/per cubic meter larger than the DRIF average mass. These differences can only be partially accounted for by known random errors. Variations in flow control, face velocity, and sampling artifacts likely influence the measurement of PM(sub 2.5) speciation and mass closure. Simple statistical tests indicate that the current uncertainty estimates used in the STN network may underestimate the actual uncertainty.

Haines, Jennifer C.↗

Technology Development for the Advanced Technology Large Aperture Space Telescope (ATLAST) as a Candidate Large UV-Optical-Infrared (LUVOIR) Surveyor

The Advanced Technology Large Aperture Space Telescope (ATLAST) team has identified five key technologies to enable candidate architectures for the future large-aperture ultraviolet/optical/infrared (LUVOIR) space observatory envisioned by the NASA Astrophysics 30-year roadmap, Enduring Quests, Daring Visions. The science goals of ATLAST address a broad range of astrophysical questions from early galaxy and star formation to the processes that contributed to the formation of life on Earth, combining general astrophysics with direct-imaging and spectroscopy of habitable exoplanets. The key technologies are: internal coronagraphs, starshades (or external occulters), ultra-stable large-aperture telescopes, detectors, and mirror coatings. Selected technology performance goals include: 1x1010 raw contrast at an inner working angle of 35 milli-arcseconds, wavefront error stability on the order of 10 pm RMS per wavefront control step, autonomous on-board sensing & control, and zero-read-noise single-photon detectors spanning the exoplanet science bandpass between 400 nm and 1.8 μm. Development of these technologies will provide significant advances over current and planned observatories in terms of sensitivity, angular resolution, stability, and high-contrast imaging. The science goals of ATLAST are presented and flowed down to top-level telescope and instrument performance requirements in the context of a reference architecture: a 10-meter-class, segmented aperture telescope operating at room temperature (~290 K) at the sun-Earth Lagrange-2 point. For each technology area, we define best estimates of required capabilities, current state-of-the-art performance, and current Technology Readiness Level (TRL) - thus identifying the current technology gap. We report on current, planned, or recommended efforts to develop each technology to TRL 5.

Technology Development↗

Photovoltaic and Behind-the-Meter Battery Storage: Advanced Smart Inverter Controls and Field Demonstration

Electric utilities have little visibility of the electrical distribution system, and consequently, limited diagnostic capabilities. The distribution grid was designed for a unidirectional power flow, where energy is supplied by few large centralized power plants; however, this is set to change to meet California’s aggressive decarbonization goals. The large-scale deployment of distributed renewable generation, such as photovoltaics (PV), can have many negative effects on an unprepared grid. As illustrated in the California “duck curve,” PV generation modifies load profiles during the day, which causes steep ramping in the evening. This effect indicates the need to revise the electrical grid’s design and operation. This project sought to (a) create a centralized resource in California to test and validate distribution technology controls with industry standard PV, storage, and high-fidelity sensors, (b) support strategic and operational decisions for new grid architectures by providing simulation models, (c) promote new ways to control clusters of PV smart inverters, in accordance with California Rule 21, and (d) innovate, develop, and field test a predictive controller to maximize economic profit for the customer while supporting the grid. The controller was built using the state-of-the-art model predictive control methodology to optimally control behind-the-meter PV and battery storage. In consideration of the duck curve, the controller optimally controls the battery dispatch by charging during excess generation periods and discharging during the critical afternoon demand hours. The controller was evaluated in annual simulations and revealed the potential cost-effectiveness of behind-the-meter battery storage. The simulations showed that the annual electricity bill could be reduced by as much as 35 percent, with a payback period of the investment in battery storage in about 6 years – significantly shorter than the manufacturer’s 10-year warranty. All developed simulation models, the grid event library, and the MPC controller are open-source and available online.

Model Predictive control↗

Towards Improved Real-Time Observability of Behind-Meter PhotoVoltaic Systems: A Data-Driven Approach

The stochasticity in energy supply introduced by increased PV penetration in grid distribution systems can lead to frequent and sudden supply-demand imbalances, thereby causing voltage and frequency fluctuations. Enhanced observability, in real-time, of grid attributes such as real and reactive power flows, power injections/consumption and voltages is becoming increasingly essential to ensure smooth grid operation under these new large-scale PV integration scenarios. Two significant challenges prevent grid operators from achieving this objective: 1) Computational complexity of quasi-static timeseries simulations, and 2) Partial observability of behind-meter grid assets. In this work, we take a step towards this objective by enhancing the observability of smart inverter equipped PV systems located behind AMI meters. Smart inverters convert the DC output of PV systems into real and reactive power, the ratio of which is governed by a power factor setting. This in turn is governed by the real-time voltage at its terminal, as per a pre-set volt/var curve. While it is possible to infer the power factor setting - thereby, real and reactive power injection of the PV system - at each time interval by quasi-static time series simulations, such methods are not scalable to large grid sizes. We propose to reduce the reliance on simulations by developing a deep neural network based data-driven model which predicts the time dependent power factors of the PV systems in the grid. The model uses a small amount of simulated data to learn the dependence of power factor on 1) load and apparent PV power injection (root mean square of real and reactive power) data, and 2) AMI net-load data (for BTM PV assets). Our results show that our model can predict power factors with mean absolute error of less than 6.2% under full observability scenario and under 8.6% under the partial observability scenario. Thus, our data-driven model can reduce the amount of simulations required to compute real and reactive injections from PV systems in the distribution system with or without complete information.

14 SOLAR ENERGY↗

Noise reduction in a Mach 5 wind tunnel with a rectangular rod-wall sound shield

A rod wall sound shield was tested over a range of Reynolds numbers of 0.5 x 10 to the 7th power to 8.0 x 10 to the 7th power per meter. The model consisted of a rectangular array of longitudinal rods with boundary-layer suction through gaps between the rods. Suitable measurement techniques were used to determine properties of the flow and acoustic disturbance in the shield and transition in the rod boundary layers. Measurements indicated that for a Reynolds number of 1.5 x 10 to the 9th power the noise in the shielded region was significantly reduced, but only when the flow is mostly laminar on the rods. Actual nozzle input noise measured on the nozzle centerline before reflection at the shield walls was attenuated only slightly even when the rod boundary layer were laminar. At a lower Reynolds number, nozzle input noise at noise levels in the shield were still too high for application to a quiet tunnel. At Reynolds numbers above 2.0 x 10 the the 7th power per meter, measured noise levels were generally higher than nozzle input levels, probably due to transition in the rod boundary layers. The small attenuation of nozzle input noise at intermediate Reynolds numbers for laminar rod layers at the acoustic origins is apparently due to high frequencies of noise.

Creel, T. R., Jr.↗

A new linearized theory of laminar film condensation of two phase annular flow in a capillary pumped loop

Future large space based facilities, such as Space Station, will require energy management systems capable of transporting tens of kilowatts of heat over a hundred meters or more. This represents better than an order of magnitude improvement over current technology. Two-phase thermal systems are currently being developed to meet this challenge. Condensation heat transfer plays a very important role in this system. The present study attempts an analytic solution to the set of linearized partial differential equations. The axial velocity and temperature functions were found to be Bessel functions which have oscillatory behavior. This result agrees qualitatively with the experimental evidence from tests at both NASA Goddard Space Flight Center and elsewhere.

Hsu, Y. K.↗

Interaction of Airspace Partitions and Traffic Flow Management Delay

To ensure that air traffic demand does not exceed airport and airspace capacities, traffic management restrictions, such as delaying aircraft on the ground, assigning them different routes and metering them in the airspace, are implemented. To reduce the delays resulting from these restrictions, revising the partitioning of airspace has been proposed to distribute capacity to yield a more efficient airspace configuration. The capacity of an airspace partition, commonly referred to as a sector, is limited by the number of flights that an air traffic controller can safely manage within the sector. Where viable, re-partitioning of the airspace distributes the flights over more efficient sectors and reduces individual sector demand. This increases the overall airspace efficiency, but requires additional resources in some sectors in terms of controllers and equipment, which is undesirable. This study examines the tradeoff of the number of sectors designed for a specified amount of traffic in a clear-weather day and the delays needed for accommodating the traffic demand. Results show that most of the delays are caused by airport arrival and departure capacity constraints. Some delays caused by airspace capacity constraints can be eliminated by re-partitioning the airspace. Analyses show that about 360 high-altitude sectors, which are approximately today s operational number of sectors of 373, are adequate for delays to be driven solely by airport capacity constraints for the current daily air traffic demand. For a marginal increase of 15 seconds of average delay, the number of sectors can be reduced to 283. In addition, simulations of traffic growths of 15% and 20% with forecasted airport capacities in the years 2018 and 2025 show that delays will continue to be governed by airport capacities. In clear-weather days, for small increases in traffic demand, increasing sector capacities will have almost no effect on delays.

Palopo, Kee↗

(abstract) Measurement of Aerodynamic Roughness Using Radar Backscatter over Vegetated Surfaces

Gathering of local information from remote platforms is often a more cost-effective way of obtaining the required data type than are local measurements. A good example is the collection of wind regime data in order to infer the amount and type of aeolian transport at a given site. This paper describes a potential mechanism for remotely inferring the wind regime from synthetic aperture radar data and describes a project to estimate the practicality of using such a mechanism. Both radar backscatter and wind flow are functions of the roughness of the site under study. It is therefore reasonable to suspect that a fairly well-behaved relationship might exist between normalized radar backscatter coefficient and aerodynamic roughness length. Aeolian transport of small particles depends in turn on wind flow and is an important quantity to measure for several economic-related reasons, but the direct measurement of wind flow regime generally involves construction of wind towers and many days of data collection, making such data extremely expensive and prohibitive in areas that cannot be easily accessed. For both desert and vegetated sites where extensive wind profile data already exist, a NASA airborne multifrequency, multipolarization radar was used to acquire radar data at several incidence angles. At the vegetated sites, vegetation height varied from tens of centimeters to several meters, and surface roughness was a few centimeters.

radar↗

A Comparison of Interactional Aerodynamics Methods for a Helicopter in Low Speed Flight

Recent advances in computing subsonic flow have been applied to helicopter configurations with various degrees of success. This paper is a comparison of two specific methods applied to a particularly challenging regime of helicopter flight, very low speeds, where the interaction of the rotor wake and the fuselage are most significant. Comparisons are made between different methods of predicting the interactional aerodynamics associated with a simple generic helicopter configuration. These comparisons are made using fuselage pressure data from a Mach-scaled powered model helicopter with a rotor diameter of approximately 3 meters. The data shown are for an advance ratio of 0.05 with a thrust coefficient of 0.0066. The results of this comparison show that in this type of complex flow both analytical techniques have regions where they are more accurate in matching the experimental data.

Berry, John D.↗