Search NASA⌕ Search

SEARCH · Search NASA

Results for “Generating Site”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Design and Licensing of Irradiated Uranyl Nitrate Liquid Containers and Applicable Loading and Packaging System - 18481

Irradiated highly enriched uranyl nitrate liquid (HEUNL) solutions are typically residual materials resulting from the processing of uranium target materials in the production of radioisotopes. Traditionally, these residual materials have been processed and stored at the site of origin, due to the lack of an option for packaging, transportation and disposition. Modern alternatives to process, stabilize, package and dispose of these materials have been developed, but until recently there has not been a viable Type B package solution that could be used to ship these materials in sufficient quantities to justify the cost of an off-site disposition strategy. For this reason, most facilities that generate irradiated HEUNL materials have implemented on-site storage tanks or containers, resulting in the significant accumulation of HEUNL inventories worldwide. This paper provides an overview of the design and licensing activities for the development of sealed irradiated HEUNL transport containers to permit safe transportation of this material in the NAC Legal Weight Truck (NAC-LWT) cask. A description of the robust HEUNL container, licensing and fabrication is also presented. In addition, NAC has developed a specialized loading system to optimize the process to load, package and un-package HEUNL materials to minimize worker exposure during loading, and execute the packaging process efficiently for safe transport and retrieval. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

OB200-DV-1 Treatability Testing: Final Results

The Hanford Site in Washington state previously generated plutonium for nuclear weapons. During operations, radionuclide byproducts and chemical process fluids were intentionally and/or unintentionally released to the subsurface, resulting in more than 800 contaminated waste sites across the Central Plateau, where historical chemical separations and waste management activities took place. As the Hanford Site mission transitioned from operations to site cleanup, remediation of the vadose zone and groundwater became a priority. However, given the depth of the unsaturated zone contamination above the groundwater, the unique nature of the waste, and the continuing impacts on groundwater quality, technologies needed to be identified and evaluated for in situ remediation in the deep vadose zone (DVZ). A laboratory treatability study has been completed to evaluate site-relevant effectiveness for nine in situ technologies that may be used to treat continuing sources of contaminants in specific areas of the Central Plateau waste sites that are grouped into the 200-DV-1 Operable Unit (OU). The 200-DV-1 OU was established in 2010 to address 43 Central Plateau waste sites with complex DVZ remediation challenges. Eight of these technologies were identified through a prescreening effort that evaluated remedial technologies potentially applicable to DVZ contamination in the Central Plateau . These eight technologies were selected for further study based on site specific knowledge gaps about their effectiveness. A ninth technology was added to the treatability study based on new information from separate laboratory investigations (conducted following the prescreening effort) demonstrating the technology’s potential effectiveness (see Section 1.2 for more information) and value for inclusion in the treatability study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spatiotemporal Variability in Wind Turbine Blade Leading Edge Erosion

Wind turbine blade leading edge erosion (LEE) reduces energy production and increases wind energy operation and maintenance costs. Degradation of the blade coating and ultimately damage to the underlying blade structure are caused by collisions of falling hydrometeors with rotating blades. The selection of optimal methods to mitigate/reduce LEE are critically dependent on the rates of coating fatigue accumulation at a given location and the time variance in the accumulation of material stresses. However, no such assessment currently exists for the United States of America (USA). To address this research gap, blade coating lifetimes at 883 sites across the USA are generated based on high-frequency (5-min) estimates of material fatigue derived using a mechanistic model and robust meteorological measurements. Results indicate blade coating failure at some sites in as few as 4 years, and that the frequency and intensity of material stresses are both highly episodic and spatially varying. Time series analyses indicate that up to one-third of blade coating lifetime is exhausted in just 360 5-min periods in the Southern Great Plains (SGP). Conversely, sites in the Pacific Northwest (PNW) exhibit the same level of coating lifetime depletion in over three times as many time periods. Thus, it may be more cost-effective to use wind turbine deregulation (erosion-safe mode) for damage reduction and blade lifetime extension in the SGP, while the application of blade leading edge protective measures may be more appropriate in the PNW. Annual total precipitation and mean wind speed are shown to be poor predictors of blade coating lifetime, re-emphasizing the need for detailed modeling studies such as that presented herein.

Pryor, Sara C. (ORCID:0000000348473440)↗

Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 547: Miscellaneous Contaminated Waste Sites, Nevada National Security Site, Nevada, Revision 0

The purpose of this CADD/CAP is to present the corrective action alternatives (CAAs) evaluated for CAU 547, provide justification for selection of the recommended alternative, and describe the plan for implementing the selected alternative. Corrective Action Unit 547 consists of the following three corrective action sites (CASs): (1) CAS 02-37-02, Gas Sampling Assembly; (2) CAS 03-99-19, Gas Sampling Assembly; and(3) CAS 09-99-06, Gas Sampling Assembly. The gas sampling assemblies consist of inactive process piping, equipment, and instrumentation that were left in place after completion of underground safety experiments. The purpose of these safety experiments was to confirm that a nuclear explosion would not occur in the case of an accidental detonation of the high-explosive component of the device. The gas sampling assemblies allowed for the direct sampling of the gases and particulates produced by the safety experiments. Corrective Action Site 02-37-02 is located in Area 2 of the Nevada National Security Site (NNSS) and is associated with the Mullet safety experiment conducted in emplacement borehole U2ag on October 17, 1963. Corrective Action Site 03-99-19 is located in Area 3 of the NNSS and is associated with the Tejon safety experiment conducted in emplacement borehole U3cg on May 17, 1963. Corrective Action Site 09-99-06 is located in Area 9 of the NNSS and is associated with the Player safety experiment conducted in emplacement borehole U9cc on August 27, 1964. The CAU 547 CASs were investigated in accordance with the data quality objectives (DQOs) developed by representatives of the Nevada Division of Environmental Protection (NDEP) and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for CAU 547. Existing radiological survey data and historical knowledge of the CASs were sufficient to meet the DQOs and evaluate CAAs without additional investigation. As a result, further investigation of the CAU 547 CASs was not required. The following CAAs were identified for the gas sampling assemblies: (1) clean closure, (2) closure in place, (3) modified closure in place, (4) no further action (with administrative controls), and (5) no further action. Based on the CAAs evaluation, the recommended corrective action for the three CASs in CAU 547 is closure in place. This corrective action will involve construction of a soil cover on top of the gas sampling assembly components and establishment of use restrictions at each site. The closure in place alternative was selected as the best and most appropriate corrective action for the CASs at CAU 547 based on the following factors: (1) Provides long-term protection of human health and the environment; (2) Minimizes short-term risk to site workers in implementing corrective action; (3) Is easily implemented using existing technology; (4) Complies with regulatory requirements; (5) Fulfills FFACO requirements for site closure; (6) Does not generate transuranic waste requiring offsite disposal; (7) Is consistent with anticipated future land use of the areas (i.e., testing and support activities); and (8) Is consistent with other NNSS site closures where contamination was left in place.

54 ENVIRONMENTAL SCIENCES↗

Achieving Leak Tightness in New Savannah River Site Saltstone Disposal Units - 17454

Saltstone Disposal Unit (SDU) 6 is a new disposal unit at the Department of Energy's Savannah River Site Saltstone Disposal Facility. The Saltstone Facility is part of the site's overarching waste management and disposal system. It receives the low-level waste stream and will immobilize in grout more than 90 percent of the liquid volume generated during treatment of the site's liquid high level waste. SDU-6 is the first in a series of large disposal units to be constructed on site. Its internal diameter and height are 114 m (375 ft) and 13.1 m (43 ft), respectively. It uses a cylindrical wire-wrapped concrete water tank design (AWWA D110, Type I), and at 121 ML (32 Mgal), it is one of the largest structures of its kind in the country. Because of its size, SDU-6's base slab was placed in ten sections. Earlier placed sections restrained newer adjacent sections, resulting in shrinkage cracking. Visible cracks were repaired with epoxy. However, the SDU basemat leaked at less than an estimated 4 L/min rate during its first full-height hydrostatic test (2015). The project baseline was to install a coating system to chemically protect the concrete from the high-pH, high-sulfate Saltstone solutions. The coating was not installed during the first hydrostatic test, and subsequently, an adhered elastomeric liner system was chosen to provide higher assurance of bridging floor cracks and preventing leakage. A robust process was used to select and install a liner that will not only provide chemical protection but also achieve leak tightness, which was successfully demonstrated in a second hydrostatic test late in 2016. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hierarchical Resilience Planning for Networked Microgrids: A Case Study of Puerto Rico

Microgrids can be designed to enhance the energy resilience of communities and critical infrastructures, such as hospitals, data centers, and communication networks, which are vulnerable to frequent weather-related disruption. Coordinating multiple microgrids in a network can leverage the geographical diversity of load and generation resources while enabling resilient and cost-effective planning of the distribution system. Designing a networked microgrid is complex, involving intricate technical assessment, cost-benefit analysis, site-specific requirements, and the evaluation of existing resources. Therefore, this paper proposes a hierarchical resilience planning framework and performs an extensive techno-economic analysis for the design of a networked microgrid. Hierarchical resilience planning involves technology sizing at an individual community level to meet the critical load and satisfy resilience criteria, and resource optimization at networked microgrid level to provide a higher level of resilience and energy adequacy. A real-world case of Puerto Rico's cooperative microgrid “Microrred de la Montaña” is investigated considering localized electricity tariffs, site-specific demand profiles, solar generation, and existing hydro resources. Multiple optimization scenarios are developed based on the resiliency requirement to estimate the capacity of solar photovoltaic and battery energy storage (BES) to be installed at each substation. The results provide the optimal sizing for individual community and networked microgrid to withstand 1day and 3-day outages along with the criteria for critical load.

13 - HYDRO ENERGY↗

Energy Facility Siting by Means of Environmental Modelling with LANDSAT, Thematic Mapper and Geographic Information System (GIS) Data

Currently based on ground and aerial surveys, the land cover data base of the Pennsylvania Power and Light Company is routinely used for modelling the effects of alternative generating plant and transmission line sites on the local and regional environment. The development of a satellite-based geographic information system would facilitate both the preparation of environmental impact statements by power companies and assessment of the data by the Nuclear Regulatory Commission. A cooperative project is planned to demonstrate the methodology for integrating satellite data into an existing geographic information system, d to further evaluate the ability of satellite data in modeling environmental conditions that would be applied in the preparation and assessment of environmental impact statements.

Source record↗

Burnt Mountain Alaska RTG Extraction, Transport and Disposal Project - 17359

The Air Force Technical Applications Center (AFTAC), headquartered at Patrick Air Force Base (AFB), Florida, removed excess nuclear material from one of the center's seismic arrays on Burnt Mountain, Alaska, after nearly 15 years of un-operability, and transferred it to a the low-level waste disposal facility at the Nevada National Security Site (NNSS). Ten radioisotope thermoelectric generators (RTGs), were used as a power source by AFTAC at its array 97 kilometers (60 miles) north of the Arctic Circle. Originally placed on Burnt Mountain in 1973, the first RTG was installed to power a single seismometer. Twelve years later, due to the increase in communications equipment and demand for additional power, nine more RTGs were placed at the site. For the next 17 years, the RTGs were operated and maintained by AFTAC's Detachment 460 based at Eielson AFB near Fairbanks, Alaska, and were used because of their high reliability and low maintenance requirements to determine if regional seismic activity was caused by nuclear explosions or naturally-occurring events such as earthquakes, volcanic activity, etc. AFTAC's primary mission is to verify compliance with nuclear test ban treaties. In 1992, a tundra fire encroached on the Burnt Mountain site and damaged some of the data cables. Despite the fact the fire did not impact the generators themselves, it raised public concern among nearby inhabitants about the safety of using radioactive material as a power source at the station. The Air Force, in coordination with multiple agencies and mission partners, made the decision to remove the RTGs and relocate them to NNSS for permanent disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prairie State Generating Company 2D Seismic Interpretation

The objectives of the Illinois Storage Corridor (ISC) project are to accelerate commercial deployment of carbon capture utilization and storage at two individual sites and receive approvals for Underground Injection Control (UIC) Class VI permits for construction at each site (ISC Project Narrative, 2020). As part of this project, and as part of the subsurface geologic characterization, two-dimensional (2D) seismic data was acquired at both sites. This report summarizes the findings from two phases of 2D acquisition and seismic interpretation at the Prairie State Generating Company site near Marissa, Illinois. The seismic data indicates the presence of three faults that completely transect the storage and confining units. The initial 2021 2D seismic acquisition revealed the presence of a feature two miles east of the Lively Grove #1 characterization well. The feature is a polyphase fault with a component of strike-slip motion, forming a small positive flower structure. The second phase of 2D seismic acquisition in 2022 constrained the maximum extent of the fault, indicating it has a relatively limited length. Other 2022 seismic lines revealed the presence of two other faults that transect the storage and confining units in the southwest and northeast portions of the 2D seismic acquisition area. The 2021 and 2022 2D seismic surveys have identified three specific locations within the project area that may have an elevated risk of out of zone CO 2 migration due to faulting. Further technical work will be needed to quantify this risk and determine how and if this risk will impact the placement of CO 2 injection wells across the project area.

01 COAL, LIGNITE, AND PEAT↗

Structural snapshots of base excision by the cancer-associated variant MutY N146S reveal a retaining mechanism

Abstract DNA glycosylase MutY plays a critical role in suppression of mutations resulted from oxidative damage, as highlighted by cancer-association of the human enzyme. MutY requires a highly conserved catalytic Asp residue for excision of adenines misinserted opposite 8-oxo-7,8-dihydroguanine (OG). A nearby Asn residue hydrogen bonds to the catalytic Asp in structures of MutY and its mutation to Ser is an inherited variant in human MUTYH associated with colorectal cancer. We captured structural snapshots of N146S Geobacillus stearothermophilus MutY bound to DNA containing a substrate, a transition state analog and enzyme-catalyzed abasic site products to provide insight into the base excision mechanism of MutY and the role of Asn. Surprisingly, despite the ability of N146S to excise adenine and purine (P) in vitro, albeit at slow rates, N146S-OG:P complex showed a calcium coordinated to the purine base altering its conformation to inhibit hydrolysis. We obtained crystal structures of N146S Gs MutY bound to its abasic site product by removing the calcium from crystals of N146S-OG:P complex to initiate catalysis in crystallo or by crystallization in the absence of calcium. The product structures of N146S feature enzyme-generated β-anomer abasic sites that support a retaining mechanism for MutY-catalyzed base excision.

59 BASIC BIOLOGICAL SCIENCES↗

Fixed-Site KAZR b1 Data Processing: Corrections, Calibrations, and Processing Report

The U.S. Department of Energy’s (DOE) Atmospheric Radiation Measurement (ARM) User Facility operates three fixed-site observatories: Eastern North Atlantic (ENA), North Slope of Alaska (NSA), and Southern Great Plains (SGP). Each fixed site has a wide variety of atmospheric instrumentation that has been collecting data for at least 10 years (NSA and SGP over 25 years). Each site is unique because it represents a different climate state. The environment at ENA is characterized by marine stratocumulus clouds and one of the key scientific areas of focus is the interaction of these clouds with aerosols. At NSA the focus is on arctic climate and cloud and radiative processes in a high-latitude environment. SGP represents a mid-latitude, mid-continent climate that experiences environmental cycles on diurnal and seasonal time scales. The ARM observatories are all meant to improve understanding of atmospheric processes that can then be better incorporated into weather and climate models. Another common thread between the fixed sites is the focus on cloud processes. Each site is equipped with at least one radar that provides continuous remote-sensing observations of clouds and precipitation. This report details the analysis of a1-level radar data at the fixed sites and the process for generating b1-level data. While b1-level data have been produced for ARM campaigns at the mobile facilities, this is the first analysis led by ARM radar mentors to correct data at the fixed sites. In particular, we focus on calibrations and corrections of the Ka-band ARM Zenith Radars (KAZRs) at ENA, NSA, and SGP. Ongoing and future work will involve corrections applied to other fixed-site radars.

54 ENVIRONMENTAL SCIENCES↗

Stabilizing Single-Atom Iron Electrocatalysts for Oxygen Reduction via Ceria Confining and Trapping

Atomically dispersed Fe-N-C materials recently hold great interest in costly Pt substitution for the cathodic oxygen reduction reaction of fuel cells. However, the heat treatment involved in the materials preparation excites Fe aggregating into low activity of nanosized species rather than high activity of single-atom Fe sites. Herein we proposed a new "ceria-assisted" strategy to preferentially generate the active single-atom Fe sites in Fe-N-C materials, which involves oxidative polymerization of pyrrole, Ce 3+ and Fe 3+ adsorption, and subsequent heat treatment. Owing to its spatial confinement and strong trapping for Fe atoms, ceria can effectively suppress agglomeration of isolated Fe atoms and stabilize the Fe atoms by bonding to O in the lattice during the heat treatment, leading to a high content of atomically dispersed Fe (4.6 wt.%). Accordingly, the final catalyst showed ultrahigh ORR activity with a half-wave potential of 0.915 V and kinetic current density of 7.15 mA cm -2 at 0.9 V. When it was as assembled an anion exchange membrane fuel cell, a large maximum power density of 496 mW cm -2 was achieved.

25 ENERGY STORAGE↗

Pyrolysis of Wood and Bark in an Auger Reactor: Physical Properties and Chemical Analysis of the Produced Bio-oils

Bio-oil was produced at 450C by fast pyrolysis in a continuous auger reactor. Four feed stocks were used: pine wood, pine bark, oak wood, and oak bark. After extensive characterization of the whole bio-oils and their pyrolytic lignin-rich ethyl acetate fractions by gas chromatography/mass spectrometry (GC/MS), gel permeation chromatography (GPC), calorific values, viscosity dependences on shear rates and temperatures, elemental analyses, {sup 1}H and {sup 13}C NMR spectroscopy, water analyses, and ash content, these bio-oils were shown to be comparable to bio-oils produced by fast pyrolysis in fluidized bed and vacuum pyrolysis processes. This finding suggests that portable auger reactors might be used to produce bio-oil at locations in forests to generate bio-oil on-site for transport of the less bulky bio-oil (versus raw biomass) to biorefineries or power generation units. The pyrolysis reported herein had lower heat transfer rates than those achieved in fluidized bed reactors, suggesting significant further improvements are possible.

09 BIOMASS FUELS↗

Integration of Rooftop Photovoltaic Systems in St. Paul Ford Site's Redevelopment Plans

The purpose of this analysis is to estimate how much electricity the redeveloped Ford Motor Company assembly plant site in St. Paul, Minnesota, might consume under different development scenarios and how much rooftop photovoltaic (PV) generation might be possible at the site. Because the current development scenarios are high-level, preliminary sketches that describe mixes of residential, retail, commercial, and industrial spaces, electricity consumption and available rooftop area for PV under each scenario can only be grossly estimated. These results are only indicative and should be used for estimating purposes only and to help inform development goals and requirements moving forward.

14 SOLAR ENERGY↗

Integrated Risk-Informed Condition Based Maintenance Capability and Automated Platform: Technical Report 3

This project is a collaborative research effort between PKMJ Technical Services LLC, Idaho National Laboratory, and Public Service Enterprise Group (PSEG) Nuclear, LLC. The collaboration, led by PKMJ Technical Services LLC, is part of the industry Funding Opportunity Announcement (FOA) award under Advanced Nuclear Technology Development FOA #DE-FOA-0001817. The pilot demonstration focuses on the Circulating Water System (CWS), an important non-safety-related system that impacts the power generation capability of the plant site. Achieving riskinformed condition-based Predictive Maintenance (PdM) on the CWS will result in significant economic benefits, and the developed methodologies can also be applied to other plant systems. This approach supports an industry goal of ensuring that nuclear power generation remains a viable, economically competitive option in the energy market. Operation and Maintenance (O&M) costs include labor-intensive Preventive Maintenance (PM) programs that involve manually performed inspection, calibration, testing, and maintenance of plant assets at periodic frequencies as well as time-based replacement of assets, irrespective of condition. This project offers an alternative by focusing on riskinformed condition-based maintenance to reduce O&M costs while still maintaining plant health and safety. This report summarizes the progress made toward achieving a risk-informed condition-based maintenance approach. The research and development (R&D) activities presented in this report are associated with development of a nuclear digital platform application, integration of fault signature models, and automated work management processes. The fault signatures and Machine Learning (ML) models are key components in predictive analytics and are heavily leveraged to improve the insights received by existing plant process data sources. Availability of the analysis results within a centralized digital platform enhances efficiency by enabling automation of activities otherwise performed manually. Personnel are presented with enhanced information that can be used to evaluate plant status and risks. Utilizing the enhancements to data analytics supports automated responses, (i.e. issuance of work orders) to address developing equipment faults and thus preventing forced, unplanned shutdowns of components or systems. The R&D activities described within this report lay the foundation for developing and demonstrating a digital automated platform to centralize the implementation of condition monitoring and response to equipment faults. The digital automated platform is cloud-based and designed to enable improved efficiency of plant processes. The digital platform includes content related to maintenance optimization, fault signature analysis, and plant records, which can all be used to support efficiencies when located within a centralized digital platform. These efficiencies could be further enhanced when deployed through industry-wide deployment of the technology to improve insights and processes based upon economies of scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flight Testing a Real-Time Hazard Detection System for Safe Lunar Landing on the Rocket-Powered Morpheus Vehicle

The Hazard Detection System (HDS) is a component of the ALHAT (Autonomous Landing and Hazard Avoidance Technology) sensor suite, which together provide a lander Guidance, Navigation and Control (GN&C) system with the relevant measurements necessary to enable safe precision landing under any lighting conditions. The HDS consists of a stand-alone compute element (CE), an Inertial Measurement Unit (IMU), and a gimbaled flash LIDAR sensor that are used, in real-time, to generate a Digital Elevation Map (DEM) of the landing terrain, detect candidate safe landing sites for the vehicle through Hazard Detection (HD), and generate hazard-relative navigation (HRN) measurements used for safe precision landing. Following an extensive ground and helicopter test campaign, ALHAT was integrated onto the Morpheus rocket-powered terrestrial test vehicle in March 2014. Morpheus and ALHAT then performed five successful free flights at the simulated lunar hazard field constructed at the Shuttle Landing Facility (SLF) at Kennedy Space Center, for the first time testing the full system on a lunar-like approach geometry in a relevant dynamic environment. During these flights, the HDS successfully generated DEMs, correctly identified safe landing sites and provided HRN measurements to the vehicle, marking the first autonomous landing of a NASA rocket-powered vehicle in hazardous terrain. This paper provides a brief overview of the HDS architecture and describes its in-flight performance.

Avoidance↗

Generation of knock-in primary human T cells using Cas9 ribonucleoproteins

T-cell genome engineering holds great promise for cell-based therapies for cancer, HIV, primary immune deficiencies, and autoimmune diseases, but genetic manipulation of human T cells has been challenging. Improved tools are needed to efficiently “knock out” genes and “knock in” targeted genome modifications to modulate T-cell function and correct disease-associated mutations. CRISPR/Cas9 technology is facilitating genome engineering in many cell types, but in human T cells its efficiency has been limited and it has not yet proven useful for targeted nucleotide replacements. Here we report efficient genome engineering in human CD4 + T cells using Cas9:single-guide RNA ribonucleoproteins (Cas9 RNPs). Cas9 RNPs allowed ablation of CXCR4, a coreceptor for HIV entry. Cas9 RNP electroporation caused up to ~40% of cells to lose high-level cell-surface expression of CXCR4, and edited cells could be enriched by sorting based on low CXCR4 expression. Importantly, Cas9 RNPs paired with homology-directed repair template oligonucleotides generated a high frequency of targeted genome modifications in primary T cells. Targeted nucleotide replacement was achieved in CXCR4 and PD-1 ( PDCD1 ), a regulator of T-cell exhaustion that is a validated target for tumor immunotherapy. Deep sequencing of a target site confirmed that Cas9 RNPs generated knock-in genome modifications with up to ~20% efficiency, which accounted for up to approximately one-third of total editing events. These results establish Cas9 RNP technology for diverse experimental and therapeutic genome engineering applications in primary human T cells.

60 APPLIED LIFE SCIENCES↗

Cryo-EM structure of the Rhodospirillum rubrum RC–LH1 complex at 2.5 Å

The reaction centre light-harvesting 1 (RC–LH1) complex is the core functional component of bacterial photosynthesis. We determined the cryo-electron microscopy (cryo-EM) structure of the RC–LH1 complex from Rhodospirillum rubrum at 2.5 Å resolution, which reveals a unique monomeric bacteriochlorophyll with a phospholipid ligand in the gap between the RC and LH1 complexes. The LH1 complex comprises a circular array of 16 αβ-polypeptide subunits that completely surrounds the RC, with a preferential binding site for a quinone, designated Q P , on the inner face of the encircling LH1 complex. Quinols, initially generated at the RC Q B site, are proposed to transiently occupy the Q P site prior to traversing the LH1 barrier and diffusing to the cytochrome bc 1 complex. Thus, the Q P site, which is analogous to other such sites in recent cryo-EM structures of RC–LH1 complexes, likely reflects a general mechanism for exporting quinols from the RC–LH1 complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗