Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Pattern formation in strongly magnetized plasmas: observations from the magnetized dusty plasma experiment (MDPX) device

The last decade has seen the development of new experimental devices to explore the physics of magnetized dusty plasmas. Because of the small charge-to-mass ratio of the charged microparticles, it is necessary to operate these experiments at high magnetic fields of several Tesla in order to observe the direct effect of the magnetic forces on the transport properties of the charged microparticles. While the study of magnetized dusty plasmas is still the ultimate goal, these experiments have also provided new opportunities to studies regimes of strongly magnetized, low temperature, laboratory plasmas that have not been extensively explored. Experiments show the formation of new types of self- and imposed-ordered structures that form in both the plasma and among the microparticles. This work summarizes recent experimental observations of plasma filamentation (in the plasma) and will discuss possible connections to 'dust gridding' phenomena that are observed in the magnetized dusty plasma experiment device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Modeling of Full Converter Adjustable-speed Pumped Storage Hydropower (FC AS-PSH)

Full converter adjustable-speed pumped storage hydropower (FC AS-PSH) technology, as one of advanced-PSH technology, is developed from wind turbine technology. By making the synchronous machine connect to the grid through a full-size converter, FC AS-PSH has a wider adjustment range of speed and a better reactive power control capability compared with a doubly-fed asynchronous generator AS-PSH technology. When it plays as an energy backup in the power system, FC AS-PSH can provide a much faster response than conventional-PSH (C-PSH) which makes this technology provide better ancillary service for a high renewable penetrated system. In this paper, the dynamic modeling of FC AS-PSH is fully studied. We develop a detailed model of this technology in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform. Especially, the first governor model is developed based on the Engineer’s Program Control Language (EPCL) user-defined model in this platform. All operation modes are validated and studied under a system contingency. Besides, comparison cases between FC AS-PSH and C-PSH are studied to show advantages providing from FC AS-PSH when it works with renewable energy.

50 EE - Wind and Water Power Program - Water (EE-4↗

Cooperative Model Predictive Control Scheme for Dispersed Smart Inverters at the Grid Edge

Growing number of distributed energy resources (DERs) requires cutting-edge control schemes to ensure uniform but not identical involvement of DERs to address rapid fluctuations on voltage of the grid clusters. Designing such control schemes for a grid with high penetration of DERs connected various clusters is complex and depends on physical configuration of the clusters themselves. This paper proposes a two-layered cooperative model predictive control scheme for fleet of dispersed smart inverters connected to a three-phase grid cluster located at the edge of a grid cluster. The upper layer of the controller ensures cooperative operation of fleet of smart inverters to perform voltage regulation and address voltage fluctuations in the grid cluster; while the lower level controller guarantees each individual inverter obeys the dictated references for active/reactive powers by the upper layer controller. In addition, the proposed twolayered controller has low voltage ride through (LVRT) capability to support the grid clusters during voltage sags. By employing the proposed control approach, the smart inverters will inject desired active/reactive powers based on circumstance of the entire cluster while guaranteeing proper power curtailment among the generation units. The control scheme is verified by simulation.

Fard, Amin Y.↗

Critical Load Restoration using Distributed Energy Resources for Resilient Power Distribution System

Extreme weather events have a significant impact on the aging and outdated power distribution infrastructures. These high-impact low-probability (HILP) events often result in extended outages and loss of critical services, thus, severely affecting customers' safety. This calls for the need to ensure resilience in distribution networks by quickly restoring the critical services during a disaster. This paper presents an advanced feeder restoration method to restore critical loads using distributed energy resources (DERs). A resilient restoration approach is proposed that jointly maximizes the amount of restored critical loads and optimizes the restoration times by optimally allocating grid's available DER resources. The restoration problem is modeled as a mixed-integer linear program with the objective of maximizing the resilience to post-restoration failures while simultaneously satisfying grid's critical connectivity and operational constraints and ensuring a radial operation for a given open-loop feeder configuration. Simulations are performed to demonstrate the effectiveness of the proposed approach using IEEE 123-node feeder with 5 DERs supplying 11 critical loads and IEEE 906-bus feeder with 3 DERs supplying 17 critical loads. The impacts of DER availability and fuel reserve on restored networks are assessed and it is shown that the proposed approach is successfully able to restore a maximum number of critical loads using available DERs.

resilience, microgrids, reactive power, energy res↗

Robust Output Feedback Control Design for Inertia Emulation by Wind Turbine Generators

Wind generation has gained widespread use as a renewable energy source. Most wind turbines and other renewables connected to the grid through converters result in a reduction in the natural inertial response to grid frequency changes. The doubly-fed induction generator (DFIG) can be controlled to compensate for this reduction and, in fact, provide faster response than traditional synchronous machines. This paper proposes to design observer based output feedback linear quadratic regulator (LQR) and H control laws to realize the inertia emulation function and deliver fast frequency support. Furthermore, the aim is to track the reference speed by a diesel synchronous generator (DSG) in order to reach the desired inertia. The control signal is computed based on a reduced order model using the balanced truncation technique. A comparison with selective modal analysis (SMA) and balanced truncation model reduction techniques is presented. Comprehensive results show the effective emulation of synthetic inertia by implementing the control laws on a nonlinear three- phase diesel-wind system. The proposed technique is analyzed for different short circuit ratio (SCR) scenarios.

17 WIND ENERGY↗

1:52 Scale Testing of the First US Commercial Scale Floating Wind Turbine, VolturnUS: Testing Overview and the Evolution of Scale Model Testing Methods

Over the past 6 years, the University of Maine (UMaine) has been an active contributor in research and scale-model testing of floating offshore wind turbines (FOWTs). This paper serves to share the evolution of UMaine’s scale-model testing pedigree by exploring the various test campaigns at a high level, culminating with the design validation of the VolturnUS floating platform. These model test campaigns have each provided key insights into the behavior of FOWT platforms as well as improving the ability to perform model tests of FOWTs. In 2011, the UMaine-led DeepCwind Consortium carried out 1/50-scale model tests of a generic tension leg platform (TLP), a semi-submersible (semi), and a spar-buoy (spar) floating platform at the Maritime Research Institute Netherlands (MARIN) test facility. The designs were Froude-scaled and supported a scaled version of the 5-MW National Renewable Energy Laboratory (NREL) offshore research turbine. Data from these tests has been used extensively for numerical simulation validation efforts using NREL’s computer-aided engineering software FAST and laid the foundation for UMaine’s design efforts on VolturnUS. In 2013, UMaine conducted another test campaign at MARIN using the original semi-submersible from 2011 with an improved turbine as well as a 1:50-scale model of the VolturnUS concrete semi-submersible design. The improved DeepCwind semi-submersible data is currently being utilized in the validation of a large number of other analysis codes as part of the International Energy Agency’s OC5 project. In 2015, UMaine opened its own Wind/Wave test facility, the Alfond Wind/Wave Ocean Engineering Laboratory (W2). Utilizing this new facility, UMaine tested the 1:50-scale model DeepCwind semi-submersible, repeating the tests from MARIN, to validate the experimental equipment and procedures as well as demonstrate the capability of the W2. In 2016 UMaine carried out testing of a 1:52-scale model of the 100% design of the VolturnUS with a 6-MW topside as a final design validation to support the US Department of Energy-supported, full-scale Aqua Ventus demonstration project scheduled to be connected to the grid in 2019. A newly designed 6-MW scale model turbine was used in this test and the performance-matched turbine design methodology is described. Selected results from the test campaign and preliminary numerical comparisons are discussed as well as key lessons learned from the model test campaigns are presented.

17 WIND ENERGY↗

Experimental Verification of ABS Concrete Design Methodology Applied to the Design of the First Commercial Scale Floating Offshore Wind Turbine in the United States

The abundance of consistent high strength winds off the world’s coastlines and the close proximity to dense population centers has led to development of innovative marine structures to support wind turbines to capture this energy resource. Off the US coast, 60% of the offshore wind lies in deep water (greater than 60m) where the development of Floating Offshore Wind Turbine (FOWT) hull technology will likely be required in lieu of fixed bottom technology such as jacket structures. The United States National Renewable Energy Laboratory (NREL) and the offshore wind community commonly refer to 60m as the transition point between fixed bottom structures and floating structures due to economic reasons. Floating wind turbines deployed in the harsh offshore marine environment require the use of materials that are cost-effective, corrosion resistant, require little maintenance and are highly durable. This has led the University of Maine to develop a concrete hull technology called VolturnUS for full-scale 6MW FOWTs. In this work, experimental testing was conducted to verify the performance of the concrete under operational, serviceability, and extreme loading conditions as required by the American Bureau of Shipping Guide for Building and Classing Floating Offshore Wind Turbines. Here, the testing included structural testing sub-components of the hull and served as experimental verification of American Bureau of Shipping (ABS) concrete design methodology which is currently approved and being used to design the first commercial scale FOWTs in the United States. Two 6MW wind turbines supported on VolturnUS concrete hulls will be used for the New England Aqua Ventus I project. The project is planned to be deployed and connected to the grid by 2019 in the Northeast U.S. and is funded by the US Department of Energy.

Concretes↗

SU-FF-T-390: In-Vivo Prostate Brachytherapy Absorbed Dose Measurements

Purpose: In-vivo prostate brachytherapy absorbed dosimetrydetector using scintillating fibers. Method and Materials: Five pairs of 85.5 {+-} 0.05 cm long blue shifted scintillating fibers (model BCF-10) with 1 mm{sup 2} cross sectional area were placed in a mixture of gelatin (368.6 {+-} 0.5 grams) and water (3.78 {+-} 0.025 liters) to measured the absorbed dose delivered by a 12 Ci {sup 192}Ir HDR source. The fibers were held by a 7 x 7 cm{sup 2} template grid and optically connected to a 16-channel multianode photomultiplier tube (Hamamatsu, model H6568). Each pair consisted of one fiber 4 mm shorter than the other one to extract the dose by the subtraction method. A dose atlas was used for radiation delivered to the phantom. The plans followed delivered 5 and 7 Gy to a point located 2.0 centimeters away from the central dwelling positions. A total of 32 data points were acquired in a plan to assess the linearity and reproducibility of the measurements.Results: Reproducibility of the data was found to be within 5% and the overall accuracy of the system estimated to be {+-}5.5%. The linearity of the data for all 7 measureddose values (ranging from 0.6 to 7 Gy), gives a slope of 312 counts/Gy with a 1.4% relative deviation. Conclusion: This work indicates the possibility of measuring in real-time the dose effectively delivered to a biological system during prostate brachytherapy treatments. The availability of commercially thin (150 {micro}m) scintillating fibers opens the capability of using such system during clinical treatments (by embedding the fibers within the catheters) with the advantage of performing real-time adjustment of the dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

SAM™ (System Advisor Model™) [SWR-16-02, SWR-10-13]

See the SAM™ website to build a desktop version of the National Laboratory of the Rockies' (NLR's) System Advisor Model™ (SAM). https://sam.nlr.gov/ The System Advisor Model™ (SAM™) is a free techno-economic software model that facilitates decision-making for people in the renewable energy industry: -Project managers and engineers -Policy analysts -Technology developers -Researchers SAM can model many types of renewable energy systems: -Photovoltaic systems, from small residential rooftop to large utility-scale systems -Battery storage with Lithium ion, lead acid, or flow batteries for front-of-meter or behind-the-meter applications -Concentrating Solar Power systems for electric power generation, including parabolic trough, power tower, and linear Fresnel -Industrial process heat from parabolic trough and linear Fresnel systems -Wind power, from individual turbines to large wind farms -Marine energy wave and tidal systems -Solar water heating -Fuel cells -Geothermal power generation -Biomass combustion for power generation -High concentration photovoltaic systems SAM's financial models are for the following types of projects: -Residential and commercial projects where the renewable energy system is on the customer side of the electric utility meter (behind the meter), and power from the system is used to reduce the customer's electricity bill. -Power purchase agreement (PPA) projects where the system is connected to the grid at an interconnection point, and the project earns revenue through power sales. The project may be owned and operated by a single owner or by a partnership involving a flip or leaseback arrangement. -Third party ownership where the system is installed on the customer's (host) property and owned by a separate entity (developer), and the host is compensated for power generated by the system through either a PPA or lease agreement. For a more detailed description of SAM, see Blair et al. (2018), System Advisor Model (SAM) General Description (Version 2017.9.5), NREL/TP-6A20-70414. https://www.nrel.gov/docs/fy18osti/70414.pdf

Ryberg, David↗

PG&E WaveConnect Program (Final Report)

The PG&E WaveConnect project was intended to demonstrate the technical and economic viability of wave power in the open ocean adjacent to PG&E's service territory. WaveConnect was conceived as a multi-stage development process leading to long-term megawatt-scale wave power production. The first-stage tasks consisted of site selection, permitting, pilot plant design, and assessment of technology and commercial readiness. The second stage would have included development of infrastructure, undersea cabling, and deployment of wave energy conversion devices (WECs). In the third stage, the most promising WEC devices would have been deployed in larger quantities and connected to the grid. This report documents the findings of Stage One. Site Selection: After studying the wave energy potential, grid interconnection and other project infrastructure along the California coast, PG&E selected two sites: one near Eureka, called the Humboldt WaveConnect (HWC) project, and another near Vandenberg Air Force Base, called the Central Coast WaveConnect project (CCWC).

16 TIDAL AND WAVE POWER↗

Microgrid Design Toolkit (MDT) Technical Documentation and Component Summaries

The Microgrid Design Toolkit (MDT) is a decision support software tool for microgrid designers to use during the microgrid design process. The models that support the two main capabilities in MDT are described. The first capability, the Microgrid Sizing Capability (MSC), is used to determine the size and composition of a new microgrid in the early stages of the design process. MSC is a mixed-integer linear program that is focused on developing a microgrid that is economically viable when connected to the grid. The second capability is focused on refining a microgrid design for operation in islanded mode. This second capability relies on two models: the Technology Management Optimization (TMO) model and Performance Reliability Model (PRM). TMO uses a genetic algorithm to create and refine a collection of candidate microgrid designs. It uses PRM, a simulation based reliability model, to assess the performance of these designs. TMO produces a collection of microgrid designs that perform well with respect to one or more performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A New Remote Communications Link to Reduce Residential PV Solar Costs

Monitoring of PV/DER site production is expensive to install and unreliable. Among third party systems providers, lost communications links are a growing concern. Nearly 20% of links are failing, provisioning is complex, recovery is expensive, production data is lost, and access is fragmented. FleetLink is a new concept in DER system communications, purpose built for lowering the cost of maintaining active contact with residential end user sites and ensuring that production data is reliably available to third party systems providers. Systems providers require accurate, secure system monitoring and reporting of production data and system faults while driving down overall costs to compete effectively. This plug and play, independently operating communications solution lowers the cost of fleet contact from typically .08 dollars-$.12/W down to .02 dollars -.03/W including installation and maintenance expenses. FleetLink establishes a breakthrough in simplicity that facilitates rapid expansion of residential solar by reducing initial capital outlay and lowering installation labor time and skill levels. The solution also facilitates higher DER installation growth rates by driving down maintenance costs and eliminating communications trouble calls. This is accomplished by the FleetLink’s unique network technology that enables dynamic network configuration for fast changes, and active, self-healing DER site contact for uptime assurance. Using an open source network framework with proprietary, application specific enhancements, FleetLink independently manages connectivity, security, recovery, grid control communications, and fleet expansion while presenting a compliant SunSpec interface to the third party operations centers. The net system cost savings of at least .05 dollars/W supports the SunShot cost goals and the flexibility and scalability of the solution accelerates the velocity and ubiquitous adoption of solar.

14 SOLAR ENERGY↗

Microgrid Design Toolkit (MDT) User Guide Software (V.1.1)

The Microgrid Design Toolkit (MDT) most readily supports decision analysis for new ("greenfield") microgrid designs, but can also be used to evaluate microgrids with existing infrastructure under some limitations. The current version of MDT includes two main capabilities. The first capability, the Microgrid Sizing Capability (MSC), is used to determine the size and composition of a new microgrid in the early stages of the design process. MSC is focused on developing a microgrid that is economically viable when connected to the grid. The second capability is focused on refining a microgrid design for operation in islanded mode. This second capability relies on two models: the Technology Management Optimization (TMO) model and Performance Reliability Model (PRM).

24 POWER TRANSMISSION AND DISTRIBUTION↗

New England Aqua Ventus I: 100% Hull Design (Final Technical Report)

This report serves as the final technical report for the US Department of Energy (DOE) award DE-EE0006713 (Award 6713). The project is titled “New England Aqua Ventus I Offshore Wind Advanced Technology Demonstration Project 100% Front-End Engineering and Design (FEED)”. The New England Aqua Ventus I (NEAV) project demonstrates a unique prestressed concrete semi-submersible floating hull technology, called VolturnUS. The technology is applicable to harness nearly 60% of the US offshore wind resource within 50 miles of the coast. The hull will be demonstrated at full-scale with a commercial scale wind turbine connected to the grid in the Northeast US off Monhegan Island, Maine for 20 years.

17 WIND ENERGY↗

Small Reactors in Microgrids: Technology Modeling and Selection (Net-Zero Microgrid Program Project Report)

This report demonstrates the capabilities of the net-zero microgrid (NZM) Xendee platform for modeling an SR module with electricity, heat extraction and thermal storage in microgrids configurations. The model effectively captures the most important technical and economic considerations for SR technology specific analysis: cost and operational characteristics of SR technology and financial costs and incentives. The model can analyze multiple scenarios to establish metrics for cost-competitive and zero-carbon microgrids connected to the grid or completely isolated. The model is fully integrated within the Xendee platform for modeling and analysis of clean energy microgrids with storage and generation from renewable energy sources. The model captures the capabilities, constraints, and nuances of SR by incorporating parameters related to plant economics, design efficiency and performance, plant operation and component and fuel lifespan. The cost and operational parameters modeled in the SR module are specific to the technology selected for integration in the microgrid. Cost parameters recognize advanced nuclear technology for modular production and installation based on economies of scale from factory manufacture and related commissioning, and cost reduction through technology maturation—first-of-a-kind (FOAK) and nth-of-a-Kind (NOAK). The cost parameters include installation, operations and maintenance (O&M), fuel refueling cycle, and reactor life. Installation cost reflects economies of scale due to unit sizing at scale and colocation. O&M economies of scale for both fixed- and variable-cost fuel life-cycle costs are incurred at every refueling interval, with separate front- and back-end fuel costs, as well as waste-handling and disposition costs. This report investigates key characteristics of different SR technologies suitable for microgrid applications, including design principles, sizing, coolant properties, temperature ratings, fuel structures, and life-cycle considerations. This also includes fuel technologies applicable to these SR systems, alongside strategies for nuclear-waste and spent-fuel management and approaches to address safety, security, and proliferation challenges. Four primary groups of SR technologies are examined: water-cooled, liquid-metal-cooled, high-temperature gas-cooled, and molten-salt-cooled systems. In this report, an initial guideline for technology selection is established, aligning the characteristics of the technologies with the requirements of microgrids. The selection of technology in a microgrid is influenced by various factors, including financial capacity, location and accessibility, demand type and characteristics, reliability and resilience requirements, area constraints, and the lifespan of the microgrid. The types of electrical and non-electrical applications within the microgrid also play a significant role in technology selection. The characteristics of SRs, such as their smaller size, modularity, transportability, long refueling interval, improved safety features, ability to operate in autonomous or semi-autonomous mode, and provision of high-grade heat, are particularly appealing for microgrids. Furthermore, a list of considerations for implementing SRs in microgrids is outlined. The SR model is created to be continuously improved with the acquisition of actual data on investment and operational costs, experience with supply chains, production at scale, and field deployments. In the near term, performance data on applications in microgrids will become available from lessons learned from laboratory tests, such as those planned for the Microreactor Applications Research Validation and Evaluation Project (MARVEL), led by Idaho National Laboratory (INL). The SR model incorporates scenario data and known SR design specifications, enabling technoeconomic analysis for SR deployment in microgrids. It specifically considers the distinctive attributes of SRs as generators in technoeconomic studies. SRs can be modeled and analyzed with generation from renewable-energy sources, energy storage, and flexible loads over a range of functionality and applications. This offers a comprehensive tool for feasibility studies, scenario development, and sensitivity analysis for “what-if” consideration of any range of assumptions about SRs in microgrids and other aggregations of distributed-energy resources, including virtual power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Use of the High-density UN Fuel in Heat-pipe Microreactors

Heat-pipe microreactors (HPMRs) are very small-scale nuclear reactors that employ heat pipes for heat removal. HPMRs can be easily integrated with other forms of renewable energies, used for emergency responses to disaster relief zones, deployed in remote locations not connected to the grid, and removed from sites and replaced by new ones. HPMRs can also be used for space missions as heat pipes do not rely on gravity for heat transfer. Conventional fuel materials, such as UO 2 and UCO, are currently considered in most existing HPMR designs, but ceramic UN fuel that has high uranium density, high thermal conductivity, and a high melting point may become a better fuel candidate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of Nuclear Sensors and Instrumentation Maturity in Advanced Nuclear Reactors

In the last decade, 97% of the worldwide commercial nuclear reactors connected to the grid were Light Water Reactors (LWRs). LWRs are expected to stay the dominant type of nuclear reactors for the next few decades. Reliable and redundant safety systems are required in nuclear reactors to ensure safe operation and shutdown in abnormal conditions. These safety systems are actuated by the signals obtained from several sensors and instrumentation in and out of the reactor core. Research and Development (R&D) in advanced sensors and instrumentation has gained extra attention, particularly following the accident at the Three Mile Island Unit-2 (TMI-2). In LWRs, these sensors and instrumentation have shown a high level of maturity with long operating experience. Ensuring the compatibility of these sensors and instrumentation with advanced nuclear reactors (Generation IV) is necessary, particularly with the expected expansion of the nuclear industry in the next few decades. Nuclear Sensor and instrumentation technologies used in the current generation of LWRs were investigated. The compatibility of these technologies with advanced reactors was assessed by comparing the advanced reactors' environments with those of the currently operating reactors. In addition to that, the needed R&D for such technologies was highlighted. In comparison with the LWRs environment, it was shown that advanced reactor environments are expected to experience elevated temperatures, a fast neutron spectrum, and a harsh corrosion environment. It was demonstrated that R&D is required mainly for fixed in-core nuclear sensors and instrumentation, while it is not a priority for ex-core nuclear sensors and instrumentation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗