Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Smart Inverters for Seamless Reconnection of Isolated Residential Microgrids to Utility Grid

This paper proposes an approach to achieve seamless reconnection of isolated residential microgrids to utility grid. Any abnormal condition on the grid side results in isolating the residential microgrid from utility grid, and giving the full responsibility of supplying household loads to local distributed generation (DG) units. However, after resolving the abnormal condition on the grid side, the residential microgrid needs to seamlessly reconnect to the main grid. To this end, a seamless transition algorithm is presented which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid before reconnection to the main grid. A modified control scheme is proposed for single-phase inverters which turns them into smart inverters enable to interact with seamless transition algorithm. The proposed approach synchronizes each phase voltage with its respective grid-side voltage in order to seamlessly reconnect the residential microgrid to the main grid. Case study results are carried out in PSCAD/EMTDC environment to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Method and system employing graphical electric load categorization to identify one of a plurality of different electric load types

A system for different electric loads includes sensors structured to sense voltage and current signals for each of the different electric loads; a hierarchical load feature database having a plurality of layers, with one of the layers including a plurality of different load categories; and a processor. The processor acquires voltage and current waveforms from the sensors for a corresponding one of the different electric loads; maps a voltage-current trajectory to a grid including a plurality of cells, each of which is assigned a binary value of zero or one; extracts a plurality of different features from the mapped grid of cells as a graphical signature of the corresponding one of the different electric loads; derives a category of the corresponding one of the different electric loads from the database; and identifies one of a plurality of different electric load types for the corresponding one of the different electric loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimating the Impacts of Direct Load Control Programs Using GridPIQ, a Web-Based Screening Tool

In direct load control (DLC) programs, utilities can curtail the demand of participating loads to contractually agreed-upon levels during periods of critical peak load, thereby reducing stress on the system, generation cost, and required transmission and generation capacity. Participating customers receive financial incentives. The impacts of implementing DLC programs extend well beyond peak shaving. There may be a shift of load proportional to the interrupted load to the times before or after a DLC event, and different load shifts have different consequences. Tools that can quantify the impacts of such programs on load curves, peak demand, emissions, and fossil fuel costs are currently lacking. The Grid Project Impact Quantification (GridPIQ) screening tool includes a Direct Load Control module, which takes into account project-specific inputs as well as the larger system context in order to quantify the impacts of a given DLC program. This allows users (utilities, researchers, etc.) to test and compare different program specifications and their impacts.

Demand Reponse↗

Integration of a Smart Outlet-Based Plug Load Management System with a Building Automation System

The growth of and reliance on renewable energy necessitate a multi-pronged approach to achieve grid reliability and economics. As they represent a notable portion of U.S. energy consumption, commercial buildings must play an active role in this effort. Conserving energy and responding to grid conditions through demand flexibility can be achieved through the integration of major building systems. Integration of plug and process loads with lighting and heating, ventilation, and air conditioning systems maximizes the effectiveness of integrated building energy management. In this research, we demonstrate the integration of smart outlets into a building automation system. We cover the installation process as well as the architecture required for smart outlets to communicate data to the building automation system and to receive commands back. After recording power measurements for one week as a baseline, we configured the building automation system to turn the smart outlets on and off according to a set schedule. This resulted in energy savings of 66% during 1 week on 25 plug loads. This work demonstrates that grid-interactive efficient buildings are achievable through building system integration.

building automation system↗

Parallel adaptation of general three-dimensional hybrid meshes

A new parallel dynamic mesh adaptation and load balancing algorithm for general hybrid grids has been developed. The meshes considered in this work are composed of four kinds of elements; tetrahedra, prisms, hexahedra and pyramids, which poses a challenge to parallel mesh adaptation. Additional complexity imposed by the presence of multiple types of elements affects especially data migration, updates of local data structures and interpartition data structures. Efficient partition of hybrid meshes has been accomplished by transforming them to suitable graphs and using serial graph partitioning algorithms. Communication among processors is based on the faces of the interpartition boundary and the termination detection algorithm of Dijkstra is employed to ensure proper flagging of edges for refinement. An inexpensive dynamic load balancing strategy is introduced to redistribute work load among processors after adaptation. In particular, only the initial coarse mesh, with proper weighting, is balanced which yields savings in computation time and relatively simple implementation of mesh quality preservation rules, while facilitating coarsening of refined elements. Special algorithms are employed for (i) data migration and dynamic updates of the local data structures, (ii) determination of the resulting interpartition boundary and (iii) identification of the communication pattern of processors. Several representative applications are included to evaluate the method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LA100 Equity Strategies. Chapter 12: Distribution Grid Upgrades for Equitable Resilience and Solar, Storage, and Electric Vehicle Access

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. As Los Angeles transitions toward clean energy, existing distribution grid infrastructure will need to be updated and expanded to support reliable service during routine operations, enable interconnection with distributed energy resources and electrified loads, and provide access to energy-related services during disasters. This chapter focuses on equity in distribution grid upgrades, reliability, and resilience in Los Angeles. Specifically, NREL performed grid upgrade and resilience analyses using a detailed model of the distribution grid and income-differentiated household load profiles, electric vehicle (EV) adoption patterns, distributed solar adoption, and grid reliability to explore two key questions to inform how the City of Los Angeles can ensure a resilient and reliable distribution grid for all communities during the clean energy transition: Where can distribution system upgrades can be prioritized to enable equitable access to, and adoption of, clean energy technologies and how can Los Angeles provide equitable, resilient access to electricity-related services (e.g., health care, food) during disaster events like earthquakes and flooding? The electric distribution system is the "last mile" of the grid, linking the multistate bulk power system with customers; new loads, including EVs; and distributed energy resources, such as customer and community solar and storage. This analysis focuses on the 4.8-kilovolt (kV) system, including service transformers that represent the utility-side of the grid connection for most residential customers. Chapter 17 looks at the customer-side of the grid connection with a focus on electric panel upgrade needs. The transition toward clean energy can put additional stress on the distribution system from distributed energy resources and electrification - especially EVs and increased use of electricity for heating, cooling, cooking, and hot water. This stress, measured here as the number of equipment overloads and voltage violations, correlates strongly to grid reliability and therefore is used as a proxy for understanding additional upgrades needed and to help ensure equitable access to electrification and distributed energy resources. NREL also conducted community resilience analysis to examine customer-level access to both electricity and a larger range of services, such as hospitals and grocery stores during a disaster. This analysis explicitly considers equity to understand differences in current resilience and resilience strategies to effectively improve critical services access for all Angelenos. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Occupancy-Driven Stochastic Decision Framework for Ranking Commercial Building Loads

For effective integration of building operations into the evolving demand response programs of the power grid, real-time decisions concerning the use of building appliances for grid services must excel on multiple criteria, ranging from the added value to occupants' comfort to the quality of the grid services. In this paper, we present a data-driven stochastic decision-support framework to dynamically rank load control alternatives in a commercial building, addressing the needs of multiple decision criteria (e.g. occupant comfort, grid service quality) under uncertainties in occupancy patterns. We adopt a stochastic multi-criteria decision algorithm recently applied to prioritize residential on/off loads, and extend it to i) consider complex load control decisions (e.g. dimming of lights, changing zone temperature set-points) in a commercial building; and ii) systematically integrate zonal occupancy patterns to better identify short-term (and time-varying) opportunities for grid service participation. We evaluate the performance of the proposed framework for curtailment of air-conditioning, lighting, and plug-loads in a multi-zone commercial office building for a range of design choices. With the help of a prototype system that integrates an interactive \textit{Data Analytics and Visualization} frontend we demonstrate a way for the building operators to monitor and change in real-time the available flexibility in energy consumption and to develop trust in the decision recommendations by interpreting the rationale behind the ranking.

Jain, Milan↗

Short-Term Forecasting of Thermostatic and Residential Loads Using Long Short-Term Memory Recurrent Neural Networks

Internet of Things (IoT) devices in smart grids enable intelligent energy management for grid managers and personalized energy services for consumers. Investigating a smart grid with IoT devices requires a simulation framework with IoT devices modeling. However, there lack comprehensive study on the modeling of IoT devices in smart grids. This paper investigates the IoT device modeling of a thermostatic load and implements the recurrent neural networks model for short-term load forecasting in this IoT-based thermostatic load. The recurrent neural network structure is leveraged to build a load forecasting model on temporal correlation. The temporal recurrent neural network layers including long short-term memory cells are employed to learn the data from both the simulation platform and New South Wales residential datasets. The simulation results are provided for demonstration.

electric load forecasting↗

Chapter 5: Integration of Renewable Energy Technologies in Buildings and Cities

Sustainable Energy Technologies, such as the solar, wind, and waterpower systems described in other chapters of this book, need to be integrated into our energy systems to expand access to energy while avoiding harmful effects on the environment. The existing utility system or 'grid' is a network that consists of components for generation, transmission, distribution, and control of electric power from producers (also called 'resources') to consumers (also called 'loads' or 'demand'). Public safety necessitates that the grid be reliable, and public policy requires that grid power be affordable and broadly accessible. Much of the existing power grid was constructed before the advent of modern information technology for controls and automation. The existing grid is facing new challenges related to increases in power demand, complexity in managing more diverse and distributed resources, power quality issues introduced by 'non-linear' loads (that have parasitic inductance and capacitance like LED lights or computers), physical and cybersecurity threats, and challenges to the existing economic model of costs and revenues. Increases in power demand include not only growth in population and per-capita electricity use, but also call for electricity to meet the need for heating and transportation as well. Electric vehicles are a rapidly growing example of this electrification of previously fossil-fueled uses. [Your author's Chevrolet Volt vehicle uses about the same amount of electricity as his house, around 300 kWh/month. Fortunately, both are served with solar photovoltaics (PVs)]. Therefore, there is an immediate need for improvement toward a reliable, self-regulating, efficient, and economical grid system that will allow the integration of renewable distributed power generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Time-Series Distribution Test System Based on Real Utility Data

In this paper, we provide a time-series distribution test system. This test system is a fully observable distribution grid in Midwest U.S. with smart meters (SM) installed at all end users. Our goal is to share a real U.S. distribution grid model without modification. This grid model is comprehensive and representative since it consists of both overhead lines and underground cables, and it has standard distribution grid components such as capacitor banks, line switches, substation transformers with load tap changer and secondary distribution transformers. An important uniqueness of this grid model is it has one-year smart meter measurements at all nodes, thus bridging the gap between existing test feeders and quasi-static time-series based distribution system analysis.

Bu, Fankun↗

High-Fidelity Modeling of a Type-5 Wind Turbine Gearbox (Intern Poster) [Poster]

Type-5 wind turbines are unique in their use of a permanent magnet synchronous generator, as well as their use of a hydraulic torque converter. This architecture presents an opportunity to provide steady and grid-ready energy without the need for a power converter. With infrastructure continuity and reliability being an important topic amongst renewable energies, researchers have been prompted to further investigate the benefits of type-5 turbines’ unique electromechanical configuration on stable electricity generation. Researchers involved in the WindSG project, SG standing for synchronous generator, are aiming to model a type-5 turbine using Real Time Digital Simulation (RTDS) to evaluate its efficacy in the grid. RSCAD, the software run on the RTDS, comes pre-loaded with electrical and electromechanical components to help simulate electrical generation and grid conditions. However, within this repertoire there is a lack of a component to represent a gearbox with high-fidelity. Within RSCAD’s case studies, the gearbox is often represented simply by a gear ratio value. This presented the task of developing a high-fidelity gearbox model in RSCAD for use in the larger RTDS type-5 wind turbine model. This poster describes a method of developing a lumped parameter mathematical model to represent a planetary-parallel-parallel gearbox in RSCAD for use in RTDS.

17 WIND ENERGY↗

High-Fidelity Modeling of a Type-5 Wind Turbine Gearbox (Intern Technical Presentation) (Poster)

Type-5 wind turbines are unique in their use of a permanent magnet synchronous generator, as well as their use of a hydraulic torque converter. This architecture presents an opportunity to provide steady and grid-ready energy without the need for a power converter. With infrastructure continuity and reliability being an important topic amongst renewable energies, researchers have been prompted to further investigate the benefits of type-5 turbines’ unique electromechanical configuration on stable electricity generation. Researchers involved in the WindSG project, SG standing for synchronous generator, are aiming to model a type-5 turbine using Real Time Digital Simulation (RTDS) to evaluate its efficacy in the grid. RSCAD, the software run on the RTDS, comes pre-loaded with electrical and electromechanical components to help simulate electrical generation and grid conditions. However, within this repertoire there is a lack of a component to represent a gearbox with high-fidelity. Within RSCAD’s case studies, the gearbox is often represented simply by a gear ratio value. This presented the task of developing a high-fidelity gearbox model in RSCAD for use in the larger RTDS type-5 wind turbine model. This presentation describes a method of developing a lumped parameter mathematical model to represent a planetary-parallel-parallel gearbox in RSCAD for use in RTDS.

17 WIND ENERGY↗

Scalability and Effectiveness of Smart Charge Management

The rise in electric vehicle (EV) adoption presents growing challenges for power grids, particularly from simultaneous residential charging, which can cause voltage fluctuations and increase feeder peak loads. Baltimore Gas and Electric (BGE), with support from the U.S. Department of Energy, initiated a pilot program to evaluate managed residential EV charging through Smart Charge Management (SCM). This study analyzes real-world charging behavior data from the pilot and feeder-level base loads from BGE to simulate residential charging scenarios through 2035 across the Washington, DC–Baltimore region. Grid impacts under unmanaged charging are compared to three SCM strategies: TOU-immediate, TOU-distributed, and Load Balancing. Results show that the magnitude of peak reduction is highly feeder-dependent. Some feeders achieve reductions of more than 40% at high enrollment levels, while others show improvements closer to 10–15%. This heterogeneity reflects differences in baseline feeder load shapes, EV penetration, and plug-in behavior across customers. Results also highlight trade-offs between shifting load away from peak periods and minimizing secondary demand peaks, offering practical insights for future utility program design.

Electric vehicle↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

An RTDS-Based Testbed for Investigating the Impacts of Transmission-Level Disturbances on Solar PV Operation

The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.

14 SOLAR ENERGY↗

Improvements of the magnetic field design for SPIDER and MITICA negative ion beam sources

The design of the magnetic field configuration in the SPIDER and MITICA negative ion beam sources has evolved considerably during the past four years. This evolution was driven by three factors: 1) the experimental results of the large RF-driven ion sources at IPP, which have provided valuable indications on the optimal magnetic configurations for reliable RF plasma source operation and for large negative ion current extraction, 2) the comprehensive beam optics and heat load simulations, which showed that the magnetic field configuration in the accelerator is crucial for keeping the heat load due to electrons on the accelerator grids within tolerable limits, without compromising the optics of the negative ion beam in the foreseen operating scenarios, 3) the progress of the detailed mechanical design of the accelerator, which stimulated the evaluation of different solutions for the correction of beamlet deflections of various origin and for beamlet aiming. On this basis, new requirements and solution concepts for the magnetic field configuration in the SPIDER and MITICA beam sources have been progressively introduced and updated until the design converged. The paper presents how these concepts have been integrated into a final design solution based on a horizontal “long-range” field (few mT) in combination with a “local” vertical field of some tens of mT on the acceleration grids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗