Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat engine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Pilot scale testing of an advanced solvent in a 0.7 MWe post-combustion CO 2 capture unit

An advanced Amine Promoted Buffer Solution (APBS), APBS-CDRMax® (CDRMax), developed by Carbon Clean Solutions Limited (CCSL), was tested at the 0.7 MWe CO 2 capture facility at Kentucky Utilities E.W. Brown Generation Station using a heat-integrated two-staged stripping CO 2 capture process. The performance of the solvent was evaluated to determine operating conditions that maximized the cyclic capacity of the solvent and results in energy savings. The regeneration energy ranged from 2.9 to 3.3 GJ/ton CO 2 with 14 vol % (dry) CO 2 inlet and approximately 90 % capture. The difference in the reboiler specific heat duty at stripper pressures of 1.7 and 2.1 bar was minimal as similar amounts of water vapor were observed in the CO 2 product stream at stripper outlet. Recycling of product CO 2 increased the inlet CO 2 concentration to the absorber from 14 to 16 vol% which enhanced mass transfer from the gas to the solvent resulting in about 5 % reduction in the energy of regeneration at the lower stripper pressure. The solvent circulation rate was reduced by about 30 % relative to previous 30 wt% MEA campaign for the CO 2 target capture of 90 %. Finally, the reduced solvent make-up rate of CDRMax shows promise for capital and operating cost savings for post-combustion CO 2 capture.

42 ENGINEERING↗

Characterization of multi-regime reaction zones in a piloted inhomogeneous jet flame with local extinction

In this study, gradient free regime identification (GFRI) is applied to 1D Raman/Rayleigh/LIF measurements of temperature and major species from the intermediate velocity case of the Sydney piloted inhomogeneous jet flame series to better understand the structure of reaction zones and the downstream evolution of multi-regime characteristics. The GFRI approach allows local reaction zones to be detected and characterized as premixed, dominantly premixed, multi-regime, dominantly non-premixed, or non-premixed flame structures, based on flame markers (mixture fraction, chemical mode, and heat release rate) derived from the experimental data. The statistics of chemical mode zero-crossings, which mark premixed reaction zones, and the relative populations of flame structures are shown to be sensitive to the state of mixing in the near field of the flame and to the level of local extinction farther downstream. Multi-regime structures, where premixed and non-premixed reaction zones occur in close proximity and both contribute to overall heat release, account for nearly half the total population at streamwise locations within the first several jet diameters. There is a rapid transition within the near field whereby the relative population of non-premixed and dominantly non-premixed structures grows from 0.05 to nearly 0.5, and the population of premixed and dominantly premixed structures decreases correspondingly as fluid entering the reaction zone becomes progressively fuel-rich. Local extinction and re-ignition bring a resurgence in premixed-type structures, many of which occur at fuel-lean conditions. There are also modest populations of multi-regime structures, having chemical mode zero-crossings at lean conditions, which would not exist in a fully burning jet flame.

42 ENGINEERING↗

An in situ cell to study phase transitions in individual aerosol particles on a substrate using scanning transmission x-ray microspectroscopy

A new in situ cell to study phase transitions and chemical processes on individual aerosol particles in the x-ray transmission microscope at the PolLux beamline of the Swiss light source has been built. The cell is machined from stainless steel and aluminum components and is designed to be used in the standard mount of the microscope without need of complicated rearrangements of the microscope. The cell consists of two parts, a back part which contains connections for the gas supply, heating, cooling devices, and temperature measurement. The second part is a removable clip, which hosts the sample. This clip can be easily exchanged and brought into a sampling unit for aerosol particles. Currently, the cell can be operated at temperatures ranging from -40 to +50 deg. C. The function of the cell is demonstrated using two systems of submicron size: inorganic sodium bromide aerosols and soot originating from a diesel passenger car. For the sodium bromide we demonstrate how phase transitions can be studied in these systems and that O1s spectra from aqueous sodium bromide solution can be taken from submicron sized particles. For the case of soot, we demonstrate that the uptake of water onto individual soot particles can be studied.

36 MATERIALS SCIENCE↗

Mixed convection heat transfer in a differentially heated cavity with two rotating cylinders

Mixed convection heat transfer in a differentially heated cavity with two rotating cylinders was studied numerically for various pertinent parameters such as Richardson number, Reynolds number, non-dimensional rotation speed of the cylinder, and the location of the cylinders. The results from these simulations were validated using an open-source spectral element code, Nek5000. The results of this study were presented in terms of streamlines, isotherms, local and average Nusselt number, and temperature profiles. The results illustrated that the average Nusselt number depends strongly on the rotation speed of the cylinder, Reynolds number, and Richardson number. However, the average Nusselt number was found to be independent of the rotation speed at high Richardson number (Ri = 10). In addition, the direction of the rotation speed of the cylinders has a profound effect on the average Nusselt. Finally, the study illustrated that the magnitude and direction of the rotation speed of the cylinders have a significant effect on the flow pattern and isotherms.

42 ENGINEERING↗

Optimization of R290 variable geometry heat exchangers

Air-to-refrigerant heat exchangers (HX) are vital components in Heating, Ventilating and Air Conditioning and Refrigeration (HVAC&R) equipment. Recent literature has proposed utilizing shape-optimized, non-round tubes to reduce component size and refrigerant charge, thus enabling the adoption of low-GWP natural refrigerants like R290. However, most designs are restricted to fixed tube configurations, limiting the overall performance potential. In this work, multi-objective optimization is used in a staged approach to develop variable geometry multi-pass air-to-R290 HXs with minimal volume and airside pressure drop. Non-round tubes are used throughout the domain and each pass may have different tube arrangements to maximize HX performance. Compared to conventional fin-tube HXs, the optimized designs demonstrate more than 60% reductions in envelope volume, 30% reductions in face area, and up to 24% reduction in airside pressure drop. Additionally, the refrigerant charge reduction was up to 64%, thus enabling safe use of flammable and mildly-flammable refrigerants.

42 ENGINEERING↗

Effect of heat treatment on microstructural evolution and hardness homogeneity in laser powder bed fusion of alloy 718

The thermal history developed in laser powder bed fusion (LPBF) processes has been shown to be complex resulting in equally complex microstructures and mechanical properties. Microscopic observations and Vickers micro-hardness mapping measurements were carried out on diff ;erent section planes of LPBF alloy 718 cuboids. Three-dimensional finite element analysis was used to simulate thermal history and to predict the residual stress distribution in the as-built material. Computational thermodynamics was used to predict the micro-segregation and nucleation driving force of various phases in the bulk and in segregated regions. Varied heat-treatments such as simulated hot isostatic pressing, and double aging were applied. Their influence on the microstructure, microsegregation, precipitate formation, and micro-hardness variations of LPBF alloy 718 were investigated. Hardness map results showed heterogeneous micro-hardness on the xy- and xz-planes of the as-built parts where the bottom plane and center regions had larger hardness of ~315 HV 0.5 while the top plane and contours showed hardness of ~300 HV 0.5 . It was found that the aging treatment increased the overall hardness of the as-built condition from ~310 HV 0.5 to 470 HV 0.5 but also increased the hardness gradient throughout the coupon. After simulated hot isostatic pressing process (i.e., without applied pressure) at 1020 °C for 4 h followed by water quench (HIPWQ), the hardness gradient and hardness was minimized (~210 HV 0.5 ) as the microstructure transitioned from heterogeneous columnar grains in the as-built condition to more uniform recrystallized grains. A double aging treatment was applied to enhance hardness from ~210 HV 0.5 to ~440 HV 0.5 . Finally, HIPWQ followed by double aging produced a homogeneous microstructure and more uniform hardness map with enhanced mechanical properties in LPBF alloy 718 coupons.

36 MATERIALS SCIENCE↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Nuclear Hybrid Energy System: Molten Salt Energy Storage (Summer Report 2013)

Effective energy use is a main focus and concern in the world today because of the growing demand for energy. The nuclear hybrid energy system (NHES) is a valuable technical concept that can potentially diversify and leverage existing energy technologies. This report considers a particular NHES design that combines multiple energy systems including a nuclear reactor, energy storage system (ESS), variable renewable generator (VRG), and additional process heat applications. Energy storage is an essential component of this particular NHES because its design allows the system to produce peak power while the nuclear reactor operates at constant power output. Many energy storage options are available, but this study mainly focuses on a molten salt ESS. The primary purpose of the molten salt ESS is to enable the nuclear reactor to be a purely constant heat source by acting as a heat storage component for the reactor during times of low demand, and providing additional capacity for thermo-electric power generation during times of peak electricity demand. This report will describe the rationale behind using a molten salt ESS and identify an efficient molten salt ESS configuration that may be used in load following power applications. Several criteria are considered for effective energy storage and are used to identify the most effective ESS within the NHES. Different types of energy storage are briefly described with their advantages and disadvantages. The general analysis to determine the most efficient molten salt ESS involves two parts: thermodynamic, in which energetic and exergetic efficiencies are considered; and economic. Within the molten salt ESS, the two-part analysis covers three major system elements: molten salt ESS designs (two tank direct and thermocline), the molten salt choice, and the different power cycles coupled with the molten salt ESS. Analysis models are formulated and analyzed to determine the most effective ESS. The results show that the most efficient idealized energy storage system is the two tank direct molten salt ESS with an Air Brayton combined cycle using LiF-NaF-KF as the molten salt, and the most economical is the same design with KCl MgCl2 as the molten salt. With energy production being a major worldwide industry, understanding the most efficient molten salt ESS boosts development of an effective NHES with cheap, clean, and steady power.

42 ENGINEERING↗

Preliminary modeling of triply periodic minimal surface (TPMS) structures using RELAP5-3D

With the United States Department of Energy (DOE)’s goal of quadrupling the nation’s nuclear energy supply by 2050, and with the Advanced Fuels Campaign pushing for new types of advanced reactor fuels and geometries, the need has arisen for new nuclear fuel designs. One such design is to swap out current nuclear fuel geometries in exchange for another type of geometry, called a Triply Periodic Minimal Surface (TPMS). TPMSs are self-supporting, infinitely repeating lattices—attributes that lend themselves well to additive manufacturing. These surfaces also possess enhanced heat transfer properties thanks to their internal area changes and large surface-area-to-volume ratios. Their drawback, however, is an increased pressure drop. Given the small amount of correlations and data (Reynolds numbers in the 2,000–8,000 range), and the minimal amount of experience so far obtained by modeling TPMS structures using 1D systems codes such as the Reactor Excursion and Leak Analysis Program (RELAP5-3D), further research into this topic was needed. Using data from the University of Wisconsin - Madison (UW), curve fits were created for both a Heat Transfer Coefficient (HTC) correlation and a Darcy friction factor empirical coefficient correlation. The curves’ coefficients and multipliers were then output and utilized in RELAP5-3D models of two upcoming experiments—Flow Loop for INFLUX Pressure drop (FLIP) and Microreactor Agile Non-nuclear Experimental Test (MAGNET)—aimed at increasing the available data for Reynolds numbers to the 16,000–36,000 range for TPMS structures. The models were run under the conditions utilized by a Computational Fluid Dynamics (CFD) analysis performed by another group at Idaho National Laboratory. Only CFD pressure drop values were obtained from the FLIP test, and those values showed that the RELAP5-3D models had a lower rate of pressure increase in comparison to the CFD values. In addition, there seemed to be a vertical shift upward in the pressure drop for both models whenever the TPMS porosity decreased, and the RELAP5-3D models showed a higher vertical shift in comparison to the CFD values. The MAGNET results did not correspond to any CFD or experimental results against which they could be compared, so they were instead compared against the proposed CFD input conditions. These values were then compared with each other to make sure the model seemed to be performing as expected, paving the way for future tests that can be run for the purpose of further analyses and comparisons. The pressure drop increased with temperature and mass flow rate independently. The temperature change would decrease with increasing mass flow rate and temperature, which was just as we expected based on the fact that the lower viscosity and decreased density would result in higher friction and churning losses. The last metric that was assessed was the enthalpy flow change, which increased with increasing mass flow rate and decreasing temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Revised Heating Load Line Analysis: Addendum to ORNL/TM-2015/281

The original heating load line analysis of ORNL TM-2015/281 was modified to incorporate two adjustments of (1) removing mechanical ventilation and (2) resizing the heat pump units based on new criteria. This resulted in a lowering of the HLL slope factor from the originally rounded 1.3 level to 1.15 in DOE Region IV and V while leaving unchanged the zero-load ambient at a rounded value of 55 F. For the other four DOE regions, the zero-load ambients dropped by 1 to 2 F from those found earlier and the rounded HLL slope factors ranged from 1.05 to 1.3. The average rounded HLL slope factor over all six DOE regions is 1.15. Effects of the revised slope factor on rated HSPFs (Region IV) for single- and two-capacity units dropped from 16% in the original work to 12.6% in this report. For VS units, the HSPF reductions of 14 to 25% in the original report were lowered to a range of 9 to 21%. As in the original report, for VS units that do not limit minimum speed operation below 47 F ambient, the average HSPF reduction for the cases evaluated is approximately the same as for single- and two-capacity units. For VS units that do limit minimum speed operation below 47 F ambient, the lower 1.15 slope factor of this report generally results in small overpredictions of rated HSPF by 1 to 3% compared to functional HSPF. An exception is minimum-speed-limited VS units where the minimum speed COP at 47 F is higher than that at 62 F; one such unit was found to have an HSPF overprediction of over 14% with the 1.15 HLL slope factor level. For such VS exception cases, a default HSPF penalty should be considered. For the more typical VS units that limit minimum speed operation, use of a 1.15 slope factor for rated HSPF was found to still acceptably limit the HSPF error. If slope factors lower than 1.15 are used for HSPF ratings, some means should be considered to appropriately derate the HSPFs for VS units which limit minimum speed operation below 47 F ambient.

42 ENGINEERING↗

Actively controlled coolant tank to increase thermal storage capacity of hybrid electric vehicles

An engine and cabin thermal management system for use with a vehicle having an engine, a cabin heating system configured to thermally heat a cabin of the vehicle, a coolant system operably coupled to the engine and to the cabin heating system to thermally manage a temperature of the engine and a temperature of the cabin. The coolant system having one or more coolant thermal storage units fluidly coupled with a radiator and heater core of the coolant system forming a coolant loop. The system further having a control system configured to monitor and maintain at least a predetermined coolant temperature at the cabin heating system even during a coolant temperature decrease at the engine stops.

Amini, Mohammad Reza↗

Material selection and manufacturing for high‐temperature heat exchangers: Review of state‐of‐the‐art development, opportunities, and challenges

Abstract Many energy systems demand heat transfer at high temperatures to keep up with high demand for power, so high‐temperature material that can perform and last under these harsh conditions is needed for heat exchangers. The engineering requirements for these high‐temperature heat exchanger material call for high thermal conductivity, high resistance to fracture, high resistance to creep deformation, environmental stability in environments associated with the application, and high modulus of elasticity while maintaining low cost to make and maintain. Naturally, ceramics are a good solution for this endeavor. In the past, high‐temperature heat exchangers made from ceramics have been used. We provide examples of ceramics in relevant heat exchange applications and provide motivation where additive manufacturing (AM) can improve efficiency. AM for the relevant material is under development, and we provide insight on the AM of ceramic materials and examples of AM heat exchangers keeping cost in mind. The motivation of the review paper is to provide a framework for material and manufacturing selection for high‐temperature heat exchangers for AM to keep up with the demand for better efficiency, better material, better manufacturing, and cost moving forward with AM technology in high‐temperature ceramic heat exchangers.

36 MATERIALS SCIENCE↗

Weighted Modules and Capacities on a Riemann Surface

On a Riemann surface (in the broad sense of the word in the terminology of Hurwitz–Courant), the weighted capacity and module (with a Muckenhoupt weight) of a condenser with a finite number of plates are defined. The equality of the capacity and module of a condenser is proved, which solves a Dubinin problem.

42 ENGINEERING↗

Channel Flow of a Concentrated Suspension

A theory for creeping flow of concentrated suspensions is described that takes into account the fluctuations of particles about their mean motion. The intensity of the velocity fluctuations is characterized by an internal field analogous to the temperature in classical kinetic theories, and governed by a balance law for the fluctuation energy. Explicit forms are posed for the constitutive models relating the viscosity, conductivity, dissipation, and pressure to the temperature and mean interparticle separation. Flow between parallel plates is considered; exact and approximate solutions are found for the temperature and separation fields. The mean velocity is given in terms of a simple integral involving the temperature. The solution exhibits qualitative behavior comparable to experimental observations: particle fluctuations and the mean shearing are confined to a region near the channel wall, while a plug-like region prevails in the center.

42 ENGINEERING↗

Using optical fibers to examine thermal mixing of liquid sodium in a pool-type geometry

Sodium fast reactors (SFR) are poised to be a leading candidate for the next generation of commercial nuclear reactor deployment. Companies are commissioning designs for SFR increasing the need for experimental and computational analysis to improve the economics and safety of these reactors. Analysis of SFR behavior during reactor transients directly informs the understanding of reactor safety. Particularly, investigating the thermal transients associated with the reactor loss of flow transient allows for informed design decisions to be made regarding reactor safety. During loss of flow transients the flow rate of the coolant is significantly reduced, but not necessarily stopped. The reduction in flow rate results in coolant temperatures exiting the reactor core that can be drastically different than the coolant in upper pool. When these different temperature fluids interact, thermally stratified layers can form causing cyclic thermal fatigue on the reactor vessel potentially leading to pre-material failure. Past experimental studies have lacked high resolution temperature measurements. This research focuses on demonstrating the reliability of novel techniques for acquiring high resolution temperature measurements in a scaled liquid sodium facility. Tests are conducted that simulate postulated loss of flow transients and provide unprecedented spatial temperature distribution measurements.

42 ENGINEERING↗