Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Energy Storage Flywheels on Spacecraft

With advances in carbon composite material, magnetic bearings, microprocessors, and high-speed power switching devices, work has begun on a space qualifiable Energy Momentum Wheel (EMW). An EMW is a device that can be used on a satellite to store energy, like a chemical battery, and manage angular momentum, like a reaction wheel. These combined functions are achieved by the simultaneous and balanced operation of two or more energy storage flywheels. An energy storage flywheel typically consists of a carbon composite rotor driven by a brushless DC motor/generator. Each rotor has a relatively large angular moment of inertia and is suspended on magnetic bearings to minimize energy loss. The use of flywheel batteries on spacecraft will increase system efficiencies (mass and power), while reducing design-production time and life-cycle cost. This paper will present a discussion of flywheel battery design considerations and a simulation of spacecraft system performance utilizing four flywheel batteries to combine energy storage and momentum management for a typical LEO satellite. A proposed set of control laws and an engineering animation will also be presented. Once flight qualified and demonstrated, space flywheel batteries may alter the architecture of most medium and high-powered spacecraft.

Bartlett, Robert O.↗

Electrochemical dynamics of imidazolium ionic liquids at graphene electrodes for energy storage applications

Electric double layer capacitors (EDLCs) are prominent energy storage systems that constitute the foundation of more reliable and sustainable energy infrastructures. Modern EDLCs often incorporate ionic liquids (ILs) as a key component in their electrolytes, leveraging the high electrochemical stability of ILs to enhance device performance. The performance and functionality of these capacitors also hinge on the interfacial behavior of ILs at electrode surfaces, which remain insufficiently understood. Here, we performed synchrotron infrared nanospectroscopy (SINS) in combination with density functional theory (DFT) calculations to investigate the electric double layers (EDLs) of three imidazolium-based ILs in a custom-designed graphene liquid cell. This approach revealed new insights into the dynamics of IL EDLs and the underpinning factors originating from the IL structures. Variations in anion size and structure were found to tune the ILs’ ability to form EDLs with compact and closely-correlated ion arrangements, which are critical for enhancing their capacitive performance. These findings highlight the intricate interactions between ions governed by their structures and charge behaviors, which underscores the opportunities for targeted design of IL-based electrolytes to optimize EDLC functionality.

Electric double layers↗

Desiccants enabling energy-efficient buildings: A review

Buildings account for about 39% of the total energy consumption in the United States. Developing highly energy-efficient and environmentally friendly systems that are either actively or passively integrated into buildings plays a crucial role in decarbonizing the building sector. Among various technologies, desiccant-based energy systems have received particular attention in recent years due to their unique advantages, such as being thermally driven using low-grade waste or solar energies and being reliable over a wide range of operating ranges. Extensive research efforts have been exerted on desiccant-enabled technologies at both material and system levels aiming to increase their performance and achieve high technological readiness levels. The present review paper comprehensively discusses research works made at the system level. It overviews desiccant-based air conditioning systems, desiccant-based humidity pumps, desiccant-based thermal energy storage systems, and desiccant-based appliances. The study identifies challenges and opportunities to accelerate the commercialization of desiccant-enabled technologies. It is found that desiccant materials offer great promise to improve energy efficiency and functionality of future buildings through decoupling the latent and sensible cooling loads in air conditioning systems, humidity pumps integrated into building facades, and next-generation appliances. However, commercial viability and widespread acceptance of desiccant-based systems have been hampered by several major obstacles, including liquid and air flow mal-distribution and inferior thermo-physical properties of desiccant materials resulting in low ab/adsorption and regeneration rates and bulky/costly systems.

25 ENERGY STORAGE↗

Mesoporous MoO 2 thin films for high rate Li + storage: Effect of crystallinity and porous structure

MoO 2 has attracted much recent attention as a high capacity energy storage material. While much of the current work on MoO 2 has been focused on the high capacity four-electron reduction, this reaction is limited to slow charging process due to the large volume change and phase transitions involved. In this study we focus on one-electron insertion reactions and demonstrate that ordered mesoporous thin films of MoO 2 can show signatures of pseudocapacitive charge storage. Mesoporous MoO 2 (mp-MoO 2 ) thin films were treated at different temperatures between 350 and 700 °C to explore the role of crystallinity and nanoscale structure on charging dynamics. The porosity and pore size decreased while the crystallinity and grain size increased as the calcination temperature increased. Materials processed at 600 °C showed the best electrochemical performance due to an optimized combination of high crystallinity and small grain size. These materials could be charged and discharged in 24 s while still achieving a Li + storage capacity of 158 mAh/g. While such thin film systems do not constitute a practical energy storage device, the work here provides structural design parameters for the production of future bulk nanoporous materials.

25 ENERGY STORAGE↗

Shuttle/Centaur Upper Stage Capability

A joint project to design, develop, procure, and produce Centaur upper stages for use with the Space Shuttle is discussed. A common Centaur G stage 6 meters (19.5 feet) in length is being jointly developed. A longer version designated Centaur G Prime is being developed by NASA to accomplish the Galileo and International Solar-Polar Mission flights in 1986. The Centaur G and G Prime will have the capability to place, respectively, approximately 4540 kilograms (10,000 pounds) and 5910 kilograms (13,000 pounds) into geosynchronous orbit from a standard Shuttle parking orbit of 278 kilometers (150 nautical miles) and Shuttle performance (lift) capability 29,500 kilograms (65,000 pounds). The advent of high energy upper stage capability in 1986 will permit space users and spacecraft developers to utilize spacecraft growth, stage combination concepts with storage modules, teleoperator systems, and other mission peculiar devices to satisfy complex mission demands. These capabilities should greatly enhance the usefulness of the space environment and stimulate mission planners toward conception of innovative means to meet ever increasing mission requirements.

Clark, H. J.↗

Developing a safe on-orbit cryogenic depot

New U.S. space initiatives will require technology to realize planned programs such as piloted lunar and Mars missions. Key to the optimal execution of such missions are high performance orbit transfer vehicles and propellant storage facilities. Large amounts of liquid hydrogen and oxygen demand a uniquely designed on-orbit cryogenic propellant depot. Because of the inherent dangers in propellant storage and handling, a comprehensive system safety program must be established. This paper shows how the myriad and complex hazards demonstrate the need for an integrated safety effort to be applied from program conception through operational use. Even though the cryogenic depot is still in the conceptual stage, many of the hazards have been identified, including fatigue due to heavy thermal loading from environmental and operating temperature extremes, micrometeoroid and/or depot ancillary equipment impact (this is an important problem due to the large surface area needed to house the large quantities of propellant), docking and maintenance hazards, and hazards associated with extended extravehicular activity. Various safety analysis techniques were presented for each program phase. Specific system safety implementation steps were also listed. Enhanced risk assessment was demonstrated through the incorporation of these methods.

Bahr, Nicholas J.↗

Symposium on High Power, Ambient Temperature Lithium Batteries, 180th Meeting of the Electrochemical Society, Phoenix, AZ, Oct. 13-17, 1991, Proceedings

Papers presented in these proceedings are on the state of the art in high-power lithium batteries, a design analysis of high-power Li-TiS2 battery, the performance and safety features of spiral wound lithium/thionyl chloride cells, the feasibility of a superhigh energy density battery of the Li/BrF3 electrochemical system, and an enhanced redox process of disulfide compounds and their application in high energy storage. Attention is also given to the structure and charge-discharge characteristics of mesophase-pitch based carbons, a study of carbons and graphites as anodes for lithium rechargeable cells, Li metal-free rechargeable Li(1+x)Mn2O4/carbon cells, and rechargeable lithium batteries using V6O13/V5O5 as the positive electrode material. Other papers discuss the electrochemical stability of organic electrolytes in contact with solid inorganic cathode materials, the electrochemical behavior of methyl formate solutions, and the interface between a solid polymer electrolyte and lithium anode.

Clark, W. D. K.↗

Lustre at Petascale: Experiences in Troubleshooting and Upgrading

Some veterans in the HPC industry semi-facetiously define supercomputers as devices that convert compute-bound problems into I/O-bound problems. Effective utilization of large high performance computing resources often requires access to large amounts of fast storage. The National Institute for Computational Sciences (NICS) operates Kraken, a 1.17 PetaFLOPS Cray XT5 for the National Science Foundation (NSF). Kraken s primary file system has migrated from Lustre 1.6 to 1.8 and is currently being moved to servers external to the machine. Additional bandwidth will be made available by mounting the NICS-wide Lustre file system. Newer versions of Lustre, beyond what Cray provides, are under evaluation for stability and performance. Over the past several years of operation, Kraken s Lustre file system has evolved to be extremely stable in an effort to better serve Kraken s users.

99 GENERAL AND MISCELLANEOUS↗

DRAGON: breaking GPU memory capacity limits with direct NVM access

Heterogeneous computing with accelerators is growing in importance in high performance computing (HPC). Recently, application datasets have expanded beyond the memory capacity of these accelerators, and often beyond the capacity of their hosts. Meanwhile, nonvolatile memory (NVM) storage has emerged as a pervasive component in HPC systems because NVM provides massive amounts of memory capacity at affordable cost. Currently, for accelerator applications to use NVM, they must manually orchestrate data movement across multiple memories and this approach only performs well for applications with simple access behaviors. To address this issue, we developed DRAGON, a solution that enables all classes of GP-GPU applications to transparently compute on terabyte datasets residing in NVM. DRAGON leverages the page-faulting mechanism on the recent NVIDIA GPUs by extending capabilities of CUDA Unified Memory (UM). Our experimental results show that DRAGON transparently expands memory capacity and obtain additional speedups via automated I/O and data transfer overlapping.

Markthub, Pak↗

Regulatory Basis for Dry Spent Nuclear Fuel Storage Canister Inspections

Nuclear power plants in the United States began moving Spent Nuclear Fuel (SNF) from wet storage to dry storage in Independent Spent Fuel Storage Installations (ISFSIs) in 1986 at Surry station in Virginia. Dry storage represented an innovative solution to the problem created by the U.S. government's failure to fulfill its obligation to begin removing SNF from power plant sites. Today, about 70 ISFSIs have been placed into operation on the sites of current, or former nuclear power plants. There are currently over 2,200 SNF dry storage systems (DSSs) in service at these locations. Thirteen of these ISFSIs are located at sites with no operating reactor, and this number is due to increase in the coming years. Operating nuclear power stations use ISFSI storage to maintain wet storage capacity for recently discharged SNF. Permanently shutdown nuclear power plants use ISFSI storage to allow decommissioning and dismantlement of the power plant structures, systems, and components. The U.S. Nuclear Regulatory Commission (NRC) regulates the licensing, construction, and operation of ISFSIs under Title 10 of the U.S. Code of Federal Regulations, Energy, Part 72, Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste, and Reactor-Related Greater than Class-C Waste (10 CFR 72). When the regulations in 10 CFR 72 were created around 1980, 20 years was chosen by the NRC as the license term for a specific ISFSI license and later, for a DSS Certificate of Compliance (CoC). Twenty years was, at the time, believed to be a sufficient time period for on-site interim dry storage of spent nuclear fuel before the U.S. government began moving the spent fuel away from the plant site for final disposal. Little, if any consideration was given to providing a regulatory framework for extending ISFSI licenses and DSS CoCs beyond 20 years at that time. However, shortly after the turn of the century, with still no federal program for removing SNF from reactor sites on the near-term horizon it became apparent that most DSSs would be required to remain in service at the ISFSIs beyond the initial 20-year license term. Operation beyond the original license term requires the specific license or the DSS CoC (used at a general license ISFSI) to be renewed. The requirements for renewal of a specific ISFSI license or a DSS CoC include addressing age-related degradation of structures, systems, and components that perform or support safety functions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Enhanced High Temperature Performance of NOx Reduction Catalyst Materials

Two primary NOx after-treatment technologies have been recognized as the most promising approaches for meeting stringent NOx emission standards for diesel vehicles within the Environmental Protection Agency’s (EPA’s) 2007/2010 mandated limits, NOx Storage Reduction (NSR) and NH3 selective catalytic reduction (SCR); both are, in fact being commercialized for this application. However, in looking forward to 2015 and beyond with expected more stringent regulations, the continued viability of the NSR technology for controlling NOx emissions from lean-burn engines such as diesels will require at least two specific, significant and inter-related improvements. First, it is important to reduce system costs by, for example, minimizing the precious metal content while maintaining, even improving, performance and long-term stability. A second critical need for future NSR systems, as well as for NH3 SCR, will be significantly improved higher and lower temperature performance and stability. Furthermore, these critically needed improvements will contribute significantly to minimizing the impacts to fuel economy of incorporating these after-treatment technologies on lean-burn vehicles. To meet these objectives will require, at a minimum an improved scientific understanding of the following things: i) the various roles for the precious and coinage metals used in these catalysts; ii) the mechanisms for these various roles; iii) the effects of high temperatures on the active metal performance in their various roles; iv) mechanisms for higher temperature NOx storage performance for modified and/or alternative storage materials; v) the interactions between the precious metals and the storage materials in both optimum NOx storage performance and long term stability; vi) the sulfur adsorption and regeneration mechanisms for NOx reduction materials; vii) materials degradation mechanisms in CHA-based NH3 SCR catalysts. The objective of this CRADA project between PNNL and Cummins, Inc. is to develop a fundamental understanding of the above-listed issues. Model catalysts that are based on literature formulations are the focus of the work being carried out at PNNL. In addition, the performance and stability of more realistic high temperature NSR catalysts, supplied by JM, are being studied in order to provide baseline data for the model catalysts that are, again, based on formulations described in the open literature. For this short summary, we will primarily highlight representative results from our recent studies of the stability of candidate high temperature NSR materials.

Environmental Molecular Sciences Laboratory↗

Optimization of a solar cooling system with interior energy storage

This paper focuses on the optimization of the performance of a solar absorption cooling system composed by four units with interior energy storage. A full dynamic simulation model that includes the solar collector field, the absorption heat pump system and the building load calculation has been developed. It has been applied to optimize the coupling of a system based on this new technology of solar powered absorption heat pump, to a bioclimatic building recently constructed in the Plataforma Solar de Almeria (PSA) in Spain. The absorption heat pump system considered is composed by four heat pumps that store energy in the form of crystallized salts so that no external storage capacity is required. Each heat pump is composed of two separate barrels that can charge (store energy from the solar field) and discharge (deliver heat or cold to the building) independently. Different configurations of the four units have been analysed taking into account the storage possibilities of the system and its capacity to respond to the building loads. It has been shown how strong the influence of the control strategies in the overall performance is, and the importance of using hourly simulations models when looking for highly efficient buildings. (author)

14 SOLAR ENERGY↗

Recent Developments and Trends in Redox Flow Batteries

Stationary energy storage systems are needed to facilitate the widespread integration of intermittent renewable electricity generators, such as solar photovoltaic and wind turbines, and to improve the energy efficiency of the electrical grid. While no single technology can meet all needs, redox flow batteries (RFBs) have shown a favorable balance of cost, safety, and performance for many high-value applications. RFBs are rechargeable electrochemical devices that utilize the reversible redox reactions of two soluble electroactive species for energy storage. A compelling feature of the RFB configuration is the independent scaling of power and energy which enables cost-effective implementation of electrochemical couples with low energy density. Aqueous RFBs have been the subject of the vast majority of research efforts to date, which have yielded industry-level demonstrations. By comparison, non-aqueous RFBs are still in their infancy but have the potential for high energy density due to the extended stability window of non-aqueous electrolytes and the enriched selection of redox materials due to the broad variety of organic solvents. This chapter aims to introduce emerging, potentially transformative, strategies for enhancing RFB technologies through molecular design, electrolyte development, and cell-level engineering. Detailed discussions focus on recent developments in redox active materials (inorganic – aqueous, organic – aqueous, inorganic – non-aqueous, and organic – non-aqueous) and in system design (interdigitated flow fields, semi-solid flow cells, and hybrid flow cells). Future research directions and key challenges for RFB technologies are also highlighted.

Su, Liang↗

In-situ thermophysical measurement of flowing molten chloride salt using modulated photothermal radiometry

Molten salts are leading candidates for high-temperature heat transfer fluids (HTFs) for thermal energy storage and conversion systems in concentrated solar power (CSP) and nuclear energy power plants. The ability to probe molten salt thermal transport properties in both stationary and flowing status is important for the evaluation of their heat transfer performance under realistic operational conditions, including the temperature range and potential degradation due to corrosion and contamination. However, accurate thermal transport properties are usually challenging to obtain even for stagnant molten salts due to different sources of errors from convection, radiation, and corrosion, let alone at flowing status. To the best of authors’ knowledge, there is no available in-situ technique for measuring flowing molten salt thermal conductivity. Here, we report the first in-situ flowing molten salt thermal conductivity measurement using modulated photothermal radiometry (MPR). We could successfully perform the first in-situ thermal conductivity measurement of flowing molten NaCl-KCl-MgCl 2 in the typical operating temperature (520 and 580 °C) with flow velocities ranging from around 0.3 to 1.0 m s -1 . The relative change of the molten salt thermal conductivity was measured. Gnielinski’s correlation was also used to estimate the heat transfer coefficient h of the flowing NaCl-KCl-MgCl 2 in the given experimental condition. Furthermore, the work showed the potential of the MPR technique serving as an in-situ diagnostics tool to evaluate the heat transfer performance of flowing molten salts and other high-temperature HTFs.

14 SOLAR ENERGY↗

Thermo-Hydrological Modeling of Thermal Energy Storage in a Depleted Oil Reservoir

Thermal energy storage in oil and gas reservoirs leverages the existing surface and subsurface infrastructure, which can pave the way for economic production of geothermal energy. Existing studies on geothermal energy storage are focused mostly on the use of aquifers with more homogeneous rock and fluid properties. Coupling of heat and fluid flow in a multiphase-multicomponent system, such as an oil reservoir, is imperative especially if existing oil field assets need to be repurposed as required for a sustainable energy transition. The objective is to model the subsurface thermo-hydrological processes associated with reservoir performance and operational sustainability. The model evaluates formation pressure and temperature within the reservoir and at the injection/production wells during multiple charge and discharge cycles. Hot water (approximately 200 degrees C) heated by Concentrating Solar Power (CSP) at high pressure is injected into the existing oil reservoir for storage and produced as thermal energy for power generation, which will be accompanied by enhanced oil recovery. To demonstrate the coupled fluid and heat flow during the injection/production cycle in the subsurface reservoir, TOUGH3 (developed by Berkeley Lab) is used to simulate the thermo-hydrological (TH) processes in a multiphase, multicomponent system. Two well geometries are considered within the reservoir grid: 1) a single-well huff-n-puff system (same well is used for injection and production), and 2) an isolated injection-production well doublet. Seasonal charge and discharge cycling are implemented based on the scheduling specified in the model input file. The model reports pressure, temperature, enthalpy, liquid fluxes, heat fluxes, pore velocities, and changes in porosity & permeability due to temperature and pressure variations during the cyclic Reservoir Thermal Energy Storage (RTES) operations. The results from the simulations can be used to optimize the operational parameters (such as well spacing and injection/production rates) and round-trip efficiency for surface power-plants coupled with thermal energy storage over time. They can also serve as important inputs for levelized cost of storage estimations. The research will help to design and integrate surface renewable energy sources, such as concentrating solar power (CSP), with RTES to help balance out power supply and demand on the grid.

CSP↗

Solar multiple optimization for a solar-only thermal power plant, using oil as heat transfer fluid in the parabolic trough collectors

Usual size of parabolic trough solar thermal plants being built at present is approximately 50 MW{sub e}. Most of these plants do not have a thermal storage system for maintaining the power block performance at nominal conditions during long non-insolation periods. Because of that, a proper solar field size, with respect to the electric nominal power, is a fundamental choice. A too large field will be partially useless under high solar irradiance values whereas a small field will mainly make the power block to work at part-load conditions. This paper presents an economic optimization of the solar multiple for a solar-only parabolic trough plant, using neither hybridization nor thermal storage. Five parabolic trough plants have been considered, with the same parameters in the power block but different solar field sizes. Thermal performance for each solar power plant has been featured, both at nominal and part-load conditions. This characterization has been applied to perform a simulation in order to calculate the annual electricity produced by each of these plants. Once annual electric energy generation is known, levelized cost of energy (LCOE) for each plant is calculated, yielding a minimum LCOE value for a certain solar multiple value within the range considered. (author)

14 SOLAR ENERGY↗

Fabrication of ultrathin solid electrolyte membranes of β-Li 3 PS 4 nanoflakes by evaporation-induced self-assembly for all-solid-state batteries

All-solid-state lithium batteries are attractive candidates for next-generation energy storage devices because of their anticipated high energy density and intrinsic safety. Owing to their excellent ionic conductivity and stability with metallic lithium anodes, nanostructured lithium thiophosphate solid electrolytes such as β-Li 3 PS 4 have found use in the fabrication of all-solid lithium batteries for large-scale energy storage systems. However, current methods for preparing air-sensitive solid electrolyte membranes of lithium thiophosphates can only generate thick membranes that compromise the battery's gravimetric/volumetric energy density and thus its rate performance. To overcome this limitation, the solid electrolyte's thickness needs to be effectively decreased to achieve ideal energy density and enhanced rate performance. In this paper, we show that the evaporation-induced self-assembly (EISA) technique produces ultrathin membranes of a lithium thiophosphate solid electrolyte with controllable thicknesses between 8 and 50 μm while maintaining the high ionic conductivity of β-Li 3 PS 4 and stability with metallic lithium anodes up to 5 V. Finally, it is clearly demonstrated that this facile EISA approach allows for the preparation of ultrathin lithium thiophosphate solid electrolyte membranes for all-solid-state batteries.

25 ENERGY STORAGE↗