Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Evaluation of Photodiode and Thermopile Pyranometers for Photovoltaic Applications: Preprint

Accurately determining PV module performance in the field requires measurement of solar irradiance reaching the PV panel at a high level of accuracy and known uncertainty. Silicon detectors used in various solar energy measuring instruments including reference cells are potentially an attractive choice for multiple reasons that include faster responsivity than thermopile detectors, cheaper cost and lower maintenance. The main drawback though is the fact that the silicon detectors are only spectrally responsive in a narrow part of the solar spectrum. Therefore, to determine broadband solar irradiance a calibration factor that converts the narrowband response to broadband is required. Normally this calibration factor is a single number determined under standard conditions but then used for various scenarios including varying air-mass, panel orientation and atmospheric conditions. This would not have been an issue if all wavelengths that form the broadband spectrum responded uniformly to atmospheric constituents. Unfortunately the scattering and absorption signature varies widely across wavelengths and the calibration factor computed under certain test conditions is not appropriate for other conditions. This paper lays out the issues that will arise from the use of silicon detectors for PV performance measurement in the field. We also present a comparison of simultaneous spectral and broadband measurements from silicon and thermopile detectors and estimated measurement errors when using silicon devices for both array performance and resource assessment.

14 SOLAR ENERGY↗

AN INFRARED COMPARISON OF TYPE-1 AND TYPE-2 QUASARS

We model the optical to far-infrared spectral energy distributions (SEDs) of a sample of six type-1 and six type-2 quasars selected in the mid-infrared. The objects in our sample are matched in mid-IR luminosity and selected based on their Spitzer IRAC colors. We obtained new targeted Spitzer Infrared Spectrograph and Multiband Imaging Photometer for Spitzer observations and used archival photometry to examine the optical to far-IR SEDs. We investigate whether the observed differences between samples are consistent with orientation-based unification schemes. The type-1 objects show significant emission at 3 mum. They do not show strong polycyclic aromatic hydrocarbon (PAH) emission and have less far-IR emission on average when compared to the type-2 objects. The SEDs of the type-2 objects show a wide assortment of silicate features, ranging from weak emission to deep silicate absorption. Some also show strong PAH features. In comparison, silicate is only seen in emission in the type-1 objects. This is consistent with some of the type-2's being reddened by a foreground screen of cooler dust, perhaps in the host galaxy itself. We investigate the active galactic nucleus contribution to the far-IR emission and find it to be significant. We also estimate the star formation rate (SFR) for each of the objects by integrating the modeled far-IR flux and compare this with the SFR found from PAH emission. We find that the type-2 quasars have a higher average SFR than the type-1 quasars based on both methods, though this could be due to differences in bolometric luminosities of the objects. While we find pronounced differences between the two types of objects, none of them are inconsistent with orientation-based unification schemes.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of Langasite Crystal Orientation on Hydrogen Gas Detection up to 400°C

Hydrogen gas sensors are of great importance due to the explosive nature and volatility of H 2 at concentrations above 4%. Also important is the capability of operation at high temperatures in harsh industrial environments, aerospace, automotive, and power generation applications. Surface Acoustic Wave (SAW) technology offers many desirable properties for sensor fabrication, such as the capability of wireless and battery free operation, mass-production, small size and weight. Piezoelectric substrates or thin films, such as langasite and aluminum nitrate, exist that allow SAW devices to operate at high temperatures. Langasite SAW-based devices have been previously demonstrated as temperature, strain and gas sensors. For high temperature SAW-based gas sensors, sensitive films capable to react selectively with the target species are normally used. This work presents the detection of hydrogen gas at high-temperature (up to 470 C) using SAW resonators on the commercially available LGS plane described by Euler angles {0°, 138.5°,Ψ}. The Pt-Al 2 O 3 composite thin film is used as both the electrode and sensitive layer. Devices fabricated along different crystal orientations on the same wafer revealed different sensitivities to H 2 , which were also measured as a function of temperature up to 470 C. These different sensitivities to H 2 open the possibility of using different orientations of this commercially available LGS crystal cut to fabricate sensors capable of operating as a network, and detecting different measurands at high-temperature, including hydrogen gas.

36 MATERIALS SCIENCE↗

Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations

Purpose: To investigate the response of plastic scintillation detectors (PSDs) in a 6 MV photon beam of various field sizes using Monte Carlo simulations. Methods: Three PSDs were simulated: A BC-400 and a BCF-12, each attached to a plastic-core optical fiber, and a BC-400 attached to an air-core optical fiber. PSD response was calculated as the detector dose per unit water dose for field sizes ranging from 10x10 down to 0.5x0.5 cm{sup 2} for both perpendicular and parallel orientations of the detectors to an incident beam. Similar calculations were performed for a CC01 compact chamber. The off-axis dose profiles were calculated in the 0.5x0.5 cm{sup 2} photon beam and were compared to the dose profile calculated for the CC01 chamber and that calculated in water without any detector. The angular dependence of the PSDs' responses in a small photon beam was studied. Results: In the perpendicular orientation, the response of the BCF-12 PSD varied by only 0.5% as the field size decreased from 10x10 to 0.5x0.5 cm{sup 2}, while the response of BC-400 PSD attached to a plastic-core fiber varied by more than 3% at the smallest field size because of its longer sensitive region. In the parallel orientation, the response of both PSDs attached to a plastic-core fiber varied by less than 0.4% for the same range of field sizes. For the PSD attached to an air-core fiber, the response varied, at most, by 2% for both orientations. Conclusions: The responses of all the PSDs investigated in this work can have a variation of only 1%-2% irrespective of field size and orientation of the detector if the length of the sensitive region is not more than 2 mm long and the optical fiber stems are prevented from pointing directly to the incident source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerial navigation by dead reckoning

The problem to be solved, as presented to the pilot or observer of an aircraft, is as follows: The aircraft starting from A must land at B, the only data being the speed of the airplane, the altitude and the orientation D of the course. The above data would be amply sufficient, were it not for the fact that the airplane is constantly subjected to a wind of variable direction and strength.

AIR NAVIGATION - DEAD RECKONING↗

Earth Observatory Satellite system definition study. Report 5: System design and specifications. Volume 1: Baseline system description

A system baseline design oriented to the requirements of the next generation of Earth Observatory Satellite missions is presented. The first mission (EOS-A) is envisioned as a two-fold mission which (1) provides a continuum of data of the type being supplied by ERTS for the emerging operational applications and also (2) expands the research and development activities for future instrumentation and analysis techniques. The baseline system specifically satisfies the requirements of this first mission. However, EOS-A is expected to be the first of a series of earth observation missions. Thus the baseline design has been developed so as to accommodate these latter missions effectively as the transition is made from conventional, expendable launch vehicles and spacecraft to the Shuttle Space Transportation System era. Further, a subset of alternative missions requirements including Seasat, SEOS, SMM and MSS-5 have been analyzed to verify that the spacecraft design to serve a multi-mission role is economically sound. A key feature of the baseline system design is the concept of a modular observatory system whose elements are compatible with varying levels of launch vehicle capability. The design configuration can be used with either the Delta or Titan launch vehicles and will adapt readily to the space shuttle when that system becomes available in the early 1980's.

Source record↗

Sub-2 Kelvin Characterization of Nitrogen-Vacancy Centers in Silicon Carbide Nanopillars

The development of efficient quantum communication technologies depends on the innovation in multiple layers of its implementation, a challenge we address from the fundamental properties of the physical system at the nanoscale to the instrumentation level at the macroscale. We select a promising near-infrared quantum emitter, the nitrogen-vacancy (NV) center in 4H-SiC, and integrate it, at an ensemble level, with nanopillar structures that enhance photon collection efficiency into an objective lens. Moreover, changes in collection efficiency in pillars compared to bulk can serve as indicators of color center orientation in the lattice. To characterize NV center properties at the unprecedented sub-2 K temperatures, we incorporate compatible superconducting nanowire single photon detectors inside the chamber of an optical cryostat and create the ICECAP, the Integrated Cryogenic system for Emission, Collection And Photon detection. ICECAP measurements show no significant line-width broadening of NV ensemble emission and up to 14-fold enhancement in collected emission. With additional filtering, we measure emitter lifetimes of NV centers in a basal ( hk ) and axial ( kk ) orientation, unveiling their cryogenic values of 2.2 and 2.8 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly polarized emission from electrical spin injection into an InGaAs quantum well with free carriers

We report on a highly polarized emission from InGaAs/GaAs-quantum well light-emitting diodes in which we inject spin-polarized electrons from an Fe/Schottky contact. The emission spectra consist of the e{sub 1}h{sub 1} free exciton (FX) and a feature 12 meV below FX attributed to band-to-band (BB) recombination. The FX exhibits a maximum circular polarization of 22%, with a magnetic-field dependence characteristic of spin injection from Fe. The BB emission on the other hand exhibits a polarization that is strongly bias and temperature dependent, with intriguing magnetic-field dependence: The polarization exhibits a maximum of 78% at 2.5 T and 2 K, then decreases linearly with field and reaches −78% at 7 T, attributed to magnetic-field dependent spin relaxation in the presence of excess electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spherical fused silica cells filled with pure helium for nuclear magnetic resonance-magnetometry

High magnetic fields (>1 T) are measured by NMR magnetometers with unrivaled precision if the precessing spin sample provides long coherence times. The longest coherence times are found in diluted {sup 3}He samples, which can be hyperpolarized for sufficient signal strength. In order to have minimal influence on the homogeneity and value of the measured magnetic field, the optimal container for the {sup 3}He should be a perfect sphere. A fused silica sphere with an inner diameter of 8 mm and an outer diameter of 12 mm was made from two hemispheres by diffusion bonding leaving only a small hole for cleaning and evacuation. This hole was closed in vacuum by a CO{sub 2} laser and the inner volume was filled with a few mbars of {sup 3}He via wall permeation. NMR-measurements on such a sample had coherence times of 5 min. While the hemispheres were produced with <1 μm deviation from sphericity, the bonding left a step of ca. 50 μm at maximum. The influence of such a mismatch, its orientation, and the immediate environment of the sample is analyzed by FEM-simulations and discussed in view of coherence times and absolute field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MURAVES muon telescope: a low power consumption muon tracker for muon radiography applications

Muon Radiography or muography is based on the measurement of the absorption or scattering of cosmic muons, as they pass through the interior of large scale bodies, In particular, absorption muography has been applied to investigate the presence of hidden cavities inside the pyramids or underground, as well as the interior of volcanoes’ edifices. The MURAVES project has the challenging aim of investigating the density distribution inside the summit of Mt. Vesuvius. The information, together with that coming from gravimetric measurements, is useful as input to models, to predict how an eruption may develop. The MURAVES apparatus is a robust and low power consumption muon telescope consisting of an array of three identical and independent muon trackers, which provide in a modular way a total sensitive area of three square meters. Each tracker consists of four doublets of planes of plastic scintillator bars with orthogonal orientation, optically coupled to Silicon photomultipliers for the readout of the signal. The muon telescope has been installed on the slope of the volcano and has collected a first set of data, which are being analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of ERS-1 scatterometer and Florida State University tropical winds

Monthly mean winds from the CMODFD (wind vector data set) ERS-1 Active Microwave Instrument (AMI) scatterometer are evaluated by comparing them to monthly mean tropical Pacific and Indian Ocean wind analyses based on in-situ data. The FSU (an observation based set of fields) winds agree qualitatively with the ERS-1 winds. Magnitudes of the vector differences are 2 to 4 m/s. Evident in the ERS-1 fields are north-south oriented bands which coincide with orbital sampling swaths. These bands are more evident in the curl maps of the mean monthly wind fields. Suitability of the ERS-1 monthly mean wind fields for ocean modeling is evaluated through a comparison of results from a model of the tropical Pacific forced by both FSU and ERS-1 wind fields. Model responses in the eastern equatorial Pacific are similar, and both track variability in the observed sea level. However, ERS-1 wind results do not correlate as well to the monthly variations in the sea level data.

Legler, David M.↗

Study of the quiet corona with the SOHO/SUMER spectrometer

The Solar and Heliospheric Observatory (SOHO)/Solar Ultraviolet Measurement of Emitted Radiations (SUMER) spectrometer is developed to study the low corona and chromosphere-corona transition zone. The main scientific objectives are oriented towards the search of mechanisms producing the coronal heating and driving the first impulse of the solar wind. The main contribution will be given by an accurate measurement of line profiles, intensities and shifts combined with high angular resolution on the solar disk and above the limb. In this paper, we recall the scientific objectives, we describe the corresponding instrument capabilities and we show how the observations can be performed and the kind of data expected. The complementary role of the SOHO coronal instruments in coordinating observations to optimize the quality of the data is emphasized.

Lemaire, P.↗

Cryogenic Thermal Vacuum Testing with Remote Optical Metrology

Flexure Engineering was awarded an SBIR to research and develop technology needed to build a thermal vacuum chamber made to take laser radar metrology through a window. The XATF test is proof of concept for this, and demonstrated the need for such a chamber. XATF refers to two pieces of critical ground support equipment for NASA's JWST (James Webb Space Telescope) Integrated Science Instrument Module (ISIM), the ISIM Alignment Target Fixture (IATF) and the Master Alignment Target Fixture (MATF). These optical alignment assemblies require characterization while under cryogenic temperature. A thermal vacuum chamber equipped with a shroud cooled with gaseous and liquid nitrogen was used. An inner shroud was cooled with liquid helium to approximately 30K. The XATF assemblies were kinematically mounted and oriented inside the inner shroud such that the optical targets were visible from outside an optical window on one of the chamber ports. Laser radar and theodolite mounted outside the window took measurements of various optical targets. Two cold cycles were completed. A third cycle was aborted. Metrology was successfully taken. There were some problems with the helium system. The cryo pumps were turned off to reduce vibrations during metrology. Many new technologies and testing methods must be developed for JWST and future programs that will require precision measurements. These technologies will be applicable to other cold temperature applications, such as lunar missions and superconductors. Remote metrology technologies can also be applicable to testing in harsh environments. Facilities with remote metrology capability will be valuable.

Boyd, Guinevere↗

System and method for generating motion corrected tomographic images

A method and related system for generating motion corrected tomographic images includes the steps of illuminating a region of interest (ROI) to be imaged being part of an unrestrained live subject and having at least three spaced apart optical markers thereon. Simultaneous images are acquired from a first and a second camera of the markers from different angles. Motion data comprising 3D position and orientation of the markers relative to an initial reference position is then calculated. Motion corrected tomographic data obtained from the ROI using the motion data is then obtained, where motion corrected tomographic images obtained therefrom.

47 OTHER INSTRUMENTATION↗

Tuning the beam: a physics perspective on beam diagnostic instrumentation

In a nutshell, the role of a beam diagnostic measurement is to provide information needed to get a particle beam from Point A (injection point) to Point B (a target) in a useable condition, with 'useable' meaning the right energy and size and with acceptable losses. Specifications and performance requirements of diagnostics are based on the physics of the particle beam to be measured, with typical customers of beam parameter measurements being the accelerator operators and accelerator physicists. This tutorial will be a physics-oriented discussion of the interplay between tuning evolutions and the beam diagnostics systems that support the machine tune. This will include the differences between developing a tune and maintaining a tune, among other things. Practical longitudinal and transverse tuning issues and techniques from a variety of proton and electron machines will also be discussed.

43 PARTICLE ACCELERATORS↗

Overview of NASA's Ocean Color Instrument Solar Calibration Architecture, Pre-Launch Tests and Preliminary On-Orbit Results

Launched in February 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. Like its predecessors, OCI will provide two day global coverage of TOA radiances. Unlike its predecessors, OCI will cover a spectral range from 340nm to 2260nm. Below 900nm, OCI will include two spectrometers that continuously span the ultraviolet to 600nm and 600nm to near-infrared spectral regions to provide hyperspectral radiances sampled every 2.5 nm, with a bandwidth of 5 nm for each channel. Wavelengths above 900nm are measured in seven discrete multispectral bands of varying bandwidths, six of which are at similar wavelengths to those on heritage missions to support both atmospheric and ocean color applications. Nominal spatial resolution is similar to the SeaWiFS instrument with 1050 m at nadir. As for SeaWiFS, the pixel size increases due to a ~20 degree tilt and as a function of scan angle. Variations in the radiometric sensitivity of each OCI channel over time will be monitored by solar diffuser measurements for short term instrument gain adjustments and independent lunar measurements for trend adjustments of long time periods, similar to the approach employed for the VIIRS instrument [4]. The OCI flight-unit was built at NASA’s Goddard Space Flight Center. At the time of this writing, OCI has completed on-orbit commissioning activities and normal science operations have begun. A key aspect of the OCI architecture is the capability to trend absolute and relative calibration changes over the course of mission life with solar calibration. Every 24 hours, the PACE spacecraft performs an inertial hold as the ground track nears the North Pole which orients a Quasi-Volume Diffuser (QVD) mounted on OCI towards the sun. By knowing the irradiance of the sun and the reflectivity of the target, the absolute radiance at the input to the OCI aperture can be computed as OCI scans the target. The allowable absolute uncertainty budget for each solar calibration measurement is 1.6% 1-sigma below 900nm at beginning of life (BOL) and the allowable relative uncertainty budget is ~0.26% 1-sigma. The Solar Calibration Assembly (SCA) consists of three targets selectable via a single mechanism which also opens a door. The targets consist of a Daily Bright Target (DBT), Monthly Bright Target (MBT), and Daily Dim Target (DDT). The bright targets are quartz QVDs with the monthly target being used to track the degradation of the daily target. The dim target is used to track CCD linearity using Progressive Time-Delay Integration (PTDI). A composite baffle is attached to the SCA housing aperture to block Earth shine and stray light from the spacecraft. The SCA assembly is mounted to a view port ~90° from OCI nadir. This paper provides an overview of driving solar calibration requirements, error-budgets and early trade studies which drove the solar calibration assembly (SCA) architecture and on-orbit maneuver. Measurements of the diffuser Bidirectional Reflectance Distribution Function (BRDF) at TNO, Netherlands and GSFC are briefly described. Optical modelling and test results at the sub-system and instrument level are included. Finally, preliminary measurements on-orbit are compared to pre-launch predictions.

Joseph J Knuble↗

Overview of NASA's Ocean Color Instrument Solar Calibration Architecture, Pre-Launch Tests and Preliminary On-Orbit Results

Launched in February 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. Like its predecessors, OCI will provide two day global coverage of TOA radiances. Unlike its predecessors, OCI will cover a spectral range from 340nm to 2260nm. Below 900nm, OCI will include two spectrometers that continuously span the ultraviolet to 600nm and 600nm to near-infrared spectral regions to provide hyperspectral radiances sampled every 2.5 nm, with a bandwidth of 5 nm for each channel. Wavelengths above 900nm are measured in seven discrete multispectral bands of varying bandwidths, six of which are at similar wavelengths to those on heritage missions to support both atmospheric and ocean color applications. Nominal spatial resolution is similar to the SeaWiFS instrument with 1050 m at nadir. As for SeaWiFS, the pixel size increases due to a ~20 degree tilt and as a function of scan angle. Variations in the radiometric sensitivity of each OCI channel over time will be monitored by solar diffuser measurements for short term instrument gain adjustments and independent lunar measurements for trend adjustments of long time periods, similar to the approach employed for the VIIRS instrument [4]. The OCI flight-unit was built at NASA’s Goddard Space Flight Center. At the time of this writing, OCI has completed on-orbit commissioning activities and normal science operations have begun. A key aspect of the OCI architecture is the capability to trend absolute and relative calibration changes over the course of mission life with solar calibration. Every 24 hours, the PACE spacecraft performs an inertial hold as the ground track nears the North Pole which orients a Quasi-Volume Diffuser (QVD) mounted on OCI towards the sun. By knowing the irradiance of the sun and the reflectivity of the target, the absolute radiance at the input to the OCI aperture can be computed as OCI scans the target. The allowable absolute uncertainty budget for each solar calibration measurement is 1.6% 1-sigma below 900nm at beginning of life (BOL) and the allowable relative uncertainty budget is ~0.26% 1-sigma. The Solar Calibration Assembly (SCA) consists of three targets selectable via a single mechanism which also opens a door. The targets consist of a Daily Bright Target (DBT), Monthly Bright Target (MBT), and Daily Dim Target (DDT). The bright targets are quartz QVDs with the monthly target being used to track the degradation of the daily target. The dim target is used to track CCD linearity using Progressive Time-Delay Integration (PTDI). A composite baffle is attached to the SCA housing aperture to block Earth shine and stray light from the spacecraft. The SCA assembly is mounted to a view port ~90° from OCI nadir. This paper provides an overview of driving solar calibration requirements, error-budgets and early trade studies which drove the solar calibration assembly (SCA) architecture and on-orbit maneuver. Measurements of the diffuser Bidirectional Reflectance Distribution Function (BRDF) at TNO, Netherlands and GSFC are briefly described. Optical modelling and test results at the sub-system and instrument level are included. Finally, preliminary measurements on-orbit are compared to pre-launch predictions.

ocean color↗

A RING OF POLARIZED LIGHT: EVIDENCE FOR TWISTED CORONAL MAGNETISM IN CAVITIES

Coronal prominence cavities may be manifestations of twisted or sheared magnetic fields capable of storing the energy required to drive solar eruptions. The Coronal Multi-Channel Polarimeter (CoMP), recently installed at Mauna Loa Solar Observatory, can measure polarimetric signatures of current-carrying magnetohydrodynamic (MHD) systems. For the first time, this instrument offers the capability of daily full-Sun observations of the forbidden lines of Fe XIII with high enough spatial resolution and throughput to measure polarimetric signatures of current-carrying MHD systems. By forward-calculating CoMP observables from analytic MHD models of spheromak-type magnetic flux ropes, we show that a predicted observable for such flux ropes oriented along the line of sight is a bright ring of linear polarization surrounding a region where the linear polarization strength is relatively depleted. We present CoMP observations of a coronal cavity possessing such a polarization ring.

79 ASTRONOMY AND ASTROPHYSICS↗