Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

An image-based technique to assess the perceptual quality of clinical chest radiographs

Purpose: Current clinical image quality assessment techniques mainly analyze image quality for the imaging system in terms of factors such as the capture system modulation transfer function, noise power spectrum, detective quantum efficiency, and the exposure technique. While these elements form the basic underlying components of image quality, when assessing a clinical image, radiologists seldom refer to these factors, but rather examine several specific regions of the displayed patient images, further impacted by a particular image processing method applied, to see whether the image is suitable for diagnosis. In this paper, the authors developed a novel strategy to simulate radiologists' perceptual evaluation process on actual clinical chest images. Methods: Ten regional based perceptual attributes of chest radiographs were determined through an observer study. Those included lung grey level, lung detail, lung noise, rib-lung contrast, rib sharpness, mediastinum detail, mediastinum noise, mediastinum alignment, subdiaphragm-lung contrast, and subdiaphragm area. Each attribute was characterized in terms of a physical quantity measured from the image algorithmically using an automated process. A pilot observer study was performed on 333 digital chest radiographs, which included 179 PA images with 10:1 ratio grids (set 1) and 154 AP images without grids (set 2), to ascertain the correlation between image perceptual attributes and physical quantitative measurements. To determine the acceptable range of each perceptual attribute, a preliminary quality consistency range was defined based on the preferred 80% of images in set 1. Mean value difference ({mu}{sub 1}-{mu}{sub 2}) and variance ratio ({sigma}{sub 1}{sup 2}/{sigma}{sub 2}{sup 2}) were investigated to further quantify the differences between the selected two image sets. Results: The pilot observer study demonstrated that our regional based physical quantity metrics of chest radiographs correlated very well with their corresponding perceptual attributes. The distribution comparisons, mean value difference estimations, and variance ratio estimations of each physical quantity between sets of images from two different techniques matched our expectation that the image quality of set 1 should be better than that of set 2. Conclusions: The measured physical quantities provide a robust reflection of perceptual image quality in clinical images. The methodology can be readily applied for automated evaluation of perceptual image quality in clinical chest radiographs.

60 APPLIED LIFE SCIENCES↗

Comprehensive experimental investigation on biomass-glass beads binary fluidization: A data set for CFD model validation

Fluidization behavior of biomass and glass beads binary mixtures in a bubbling fluidized bed was experimentally investigated. Mixtures containing different mass fraction of Loblolly Pine white wood and glass beads were fluidized at different fluidization velocities. The particle properties were characterized in a QICPIC that uses a dynamic image processing method to measure both particle size and sphericity. The minimum fluidization velocity was determined using the pressure drop method. An image processing method was developed to capture the dynamic expanded bed height at a very high frequency. The effect of biomass mass fraction and inlet gas velocity on mixing and segregation behavior was studied and analyzed through pressure drop measurements. Pressure drop fluctuations and expanded bed height fluctuations via fast Fourier transform were analyzed and compared. Here, the complete and accurate experimental data reported in this study could provide a benchmark data set for various computational fluid dynamics models validation, calibration, and identification.

42 ENGINEERING↗

Vector statistics of LANDSAT imagery

A digitized multispectral image, such as LANDSAT data, is composed of numerous four dimensional vectors, which quantitatively describe the ground scene from which the data are acquired. The statistics of unique vectors that occur in LANDSAT imagery are studied to determine if that information can provide some guidance on reducing image processing costs. A second purpose of this report is to investigate how the vector statistics are changed by various types of image processing techniques and determine if that information can be useful in choosing one processing approach over another.

Jayroe, R. R., Jr.↗

In-Flight Flow Visualization Using Infrared Thermography

The feasibility of remote infrared thermography of aircraft surfaces during flight to visualize the extent of laminar flow on a target aircraft has been examined. In general, it was determined that such thermograms can be taken successfully using an existing airplane/thermography system (NASA Dryden's F-18 with infrared imaging pod) and that the transition pattern and, thus, the extent of laminar flow can be extracted from these thermograms. Depending on the in-flight distance between the F-18 and the target aircraft, the thermograms can have a spatial resolution of as little as 0.1 inches. The field of view provided by the present remote system is superior to that of prior stationary infrared thermography systems mounted in the fuselage or vertical tail of a subject aircraft. An additional advantage of the present experimental technique is that the target aircraft requires no or minimal modifications. An image processing procedure was developed which improves the signal-to-noise ratio of the thermograms. Problems encountered during the analog recording of the thermograms (banding of video images) made it impossible to evaluate the adequacy of the present imaging system and image processing procedure to detect transition on untreated metal surfaces. The high reflectance, high thermal difussivity, and low emittance of metal surfaces tend to degrade the images to an extent that it is very difficult to extract transition information from them. The application of a thin (0.005 inches) self-adhesive insulating film to the surface is shown to solve this problem satisfactorily. In addition to the problem of infrared based transition detection on untreated metal surfaces, future flight tests will also concentrate on the visualization of other flow phenomena such as flow separation and reattachment.

vanDam, C. P.↗

Intelligent robotic tracker

An intelligent tracker capable of robotic applications requiring guidance and control of platforms, robotic arms, and end effectors has been developed. This packaged system capable of supervised autonomous robotic functions is partitioned into a multiple processor/parallel processing configuration. The system currently interfaces to cameras but has the capability to also use three-dimensional inputs from scanning laser rangers. The inputs are fed into an image processing and tracking section where the camera inputs are conditioned for the multiple tracker algorithms. An executive section monitors the image processing and tracker outputs and performs all the control and decision processes. The present architecture of the system is presented with discussion of its evolutionary growth for space applications. An autonomous rendezvous demonstration of this system was performed last year. More realistic demonstrations in planning are discussed.

Otaguro, W. S.↗

Thoughts on standardization of parameters for image evaluation

Images received for image processing and analysis are obtained from a wide variety of sources and with a wide variety of sensors. Because it is desirable to have image processing algorithms be as universally applicable as possible, they should be designed, where possible, to be insensitive to the parametric variations of the source material. Where this is not possible, these variations must be taken into account. Therefore, it is necessary to consider what parameters may be defined in common across a suite of image types. Objective parameters or measurements of images which, in the proper combinations, may serve as surrogates for real images may be pixel-specific, location dependent, or combinations thereof. Parameters which have proven useful in defining the characteristics of images include the gray scale linearity, granularity of the quantization, spectral content, geometrical fidelity, resolution of the system expressed as either the point spread function or the modulation transfer function, and the spatial frequency content and characteristics of the data itself.

Billingsley, F. C.↗

Temporal analysis of the coherent properties of optical images of rough nonplanar objects

The possibility of using temporal analysis to find the relation between chromatic properties of probe radiation and coherent properties of the optical images of rough non-planar objects is substantiated. The analysis is based on the use of the time correlation function and on the study of the speckle pattern contrast in the optical images. The conditions are determined under which the different parts of the optical image of an object are coherent, partially coherent and incoherent, while probe radiation is manifested as monochromatic, quasi-monochromatic, and polychromatic. It is shown that these conditions depend considerably on the object surface shape. The use of the temporal analysis for three-dimensional imaging of an object by its planar images and improving the optical image quality by removing its speckle pattern is illustrated by examples. (optical image processing)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Programmable Multiresolution CMOS Active Pixel Sensor

CMOS active pixel sensors (APS) allow the flexibility of placing signal processing circuitry on the imaging focal plane. The multiresolution CMOS APS can perform block averaging on-chip to eliminate the off-chip software intensive image processing. This 128 x 128 APS array can be read out at any user-defined resolution by configuring a set of digital shift registers. The resolution frame rate is 30 Hz with higher rates for all other image resolutions.

APS↗

Contour interpolated radial basis functions with spline boundary correction for fast 3D reconstruction of the human articular cartilage from MR images

Purpose: The aim of this work is to demonstrate a new image processing technique that can provide a “near real-time” 3D reconstruction of the articular cartilage of the human knee from MR images which is user friendly. This would serve as a point-of-care 3D visualization tool which would benefit a consultant radiologist in the visualization of the human articular cartilage. Methods: The authors introduce a novel fusion of an adaptation of the contour method known as “contour interpolation (CI)” with radial basis functions (RBFs) which they describe as “CI-RBFs.” The authors also present a spline boundary correction which further enhances volume estimation of the method. A subject cohort consisting of 17 right nonpathological knees (ten female and seven male) is assessed to validate the quality of the proposed method. The authors demonstrate how the CI-RBF method dramatically reduces the number of data points required for fitting an implicit surface to the entire cartilage, thus, significantly improving the speed of reconstruction over the comparable RBF reconstruction method of Carr. The authors compare the CI-RBF method volume estimation to a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Results: The authors demonstrate how the CI-RBF method significantly reduces the number of data points (p-value < 0.0001) required for fitting an implicit surface to the cartilage, by 48%, 31%, and 44% for the patellar, tibial, and femoral cartilages, respectively. Thus, significantly improving the speed of reconstruction (p-value < 0.0001) by 39%, 40%, and 44% for the patellar, tibial, and femoral cartilages over the comparable RBF model of Carr providing a near real-time reconstruction of 6.49, 8.88, and 9.43 min for the patellar, tibial, and femoral cartilages, respectively. In addition, it is demonstrated how the CI-RBF method matches the volume estimation of a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Furthermore, the performance of the segmentation method used for the extraction of the femoral, tibial, and patellar cartilages is assessed with a Dice similarity coefficient, sensitivity, and specificity measure providing high agreement to manual segmentation. Conclusions: The CI-RBF method provides a fast, accurate, and robust 3D model reconstruction that matches Carr’s RBF method, 3D DOCTOR, and a manual benchmark method in accuracy and significantly improves upon Carr’s RBF method in data requirement and computational speed. In addition, the visualization tool has been designed to quickly segment MR images requiring only four mouse clicks per MR image slice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SpIES: The Spitzer IRAC Equatorial Survey

We describe the first data release from the Spitzer-IRAC Equatorial Survey (SpIES); a large-area survey of ∼115 deg{sup 2} in the Equatorial SDSS Stripe 82 field using Spitzer during its “warm” mission phase. SpIES was designed to probe sufficient volume to perform measurements of quasar clustering and the luminosity function at z ⩾ 3 to test various models for “feedback” from active galactic nuclei (AGNs). Additionally, the wide range of available multi-wavelength, multi-epoch ancillary data enables SpIES to identify both high-redshift (z ⩾ 5) quasars as well as obscured quasars missed by optical surveys. SpIES achieves 5σ depths of 6.13 μJy (21.93 AB magnitude) and 5.75 μJy (22.0 AB magnitude) at 3.6 and 4.5 μm, respectively—depths significantly fainter than the Wide-field Infrared Survey Explorer (WISE). We show that the SpIES survey recovers a much larger fraction of spectroscopically confirmed quasars (∼98%) in Stripe 82 than are recovered by WISE (∼55%). This depth is especially powerful at high-redshift (z ⩾3.5), where SpIES recovers 94% of confirmed quasars, whereas WISE only recovers 25%. Here we define the SpIES survey parameters and describe the image processing, source extraction, and catalog production methods used to analyze the SpIES data. In addition to this survey paper, we release 234 images created by the SpIES team and three detection catalogs: a 3.6 μm only detection catalog containing ∼6.1 million sources, a 4.5 μm only detection catalog containing ∼6.5 million sources, and a dual-band detection catalog containing ∼5.4 million sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Potential medical applications of TAE

In cooperation with scientists in the University of Washington Medical School, a microcomputer-based image processing system for quantitative microscopy, called DMD1 (Digital Microdensitometer 1) was constructed. In order to make DMD1 transportable to different hosts and image processors, we have been investigating the possibility of rewriting the lower level portions of DMD1 software using Transportable Applications Executive (TAE) libraries and subsystems. If successful, we hope to produce a newer version of DMD1, called DMD2, running on an IBM PC/AT under the SCO XENIX System 5 operating system, using any of seven target image processors available in our laboratory. Following this implementation, copies of the system will be transferred to other laboratories with biomedical imaging applications. By integrating those applications into DMD2, we hope to eventually expand our system into a low-cost general purpose biomedical imaging workstation. This workstation will be useful not only as a self-contained instrument for clinical or research applications, but also as part of a large scale Digital Imaging Network and Picture Archiving and Communication System, (DIN/PACS). Widespread application of these TAE-based image processing and analysis systems should facilitate software exchange and scientific cooperation not only within the medical community, but between the medical and remote sensing communities as well.

Fahy, J. Ben↗

Planetary ring dynamics and morphology

Evidence for a moonlet belt in the region between Saturn's close-in moonrings Pandora and Prometheus is discussed. It is argued that little-known observations of magnetospheric electron density by Pioneer 11 imply substantial, ongoing injections of mass into the 2000 km region which surrounds the F ring. A hypothesis is presented that these events result naturally from interparticle collisions between the smaller members of an optically thin belt of moonlets. Also discussed is work on Uranus ring structure and photometry, image processing and analysis of the Jonian ring strucure, photometric and structural studies of the A ring of Saturn, and improvements to an image processing system for ring studies.

Cuzzi, Jeffrey N.↗

The correlation study of parallel feature extractor and noise reduction approaches

This paper presents literature reviews that show variety of techniques to develop parallel feature extractor and finding its correlation with noise reduction approaches for low light intensity images. Low light intensity images are normally displayed as darker images and low contrast. Without proper handling techniques, those images regularly become evidences of misperception of objects and textures, the incapability to section them. The visual illusions regularly clues to disorientation, user fatigue, poor detection and classification performance of humans and computer algorithms. Noise reduction approaches (NR) therefore is an essential step for other image processing steps such as edge detection, image segmentation, image compression, etc. Parallel Feature Extractor (PFE) meant to capture visual contents of images involves partitioning images into segments, detecting image overlaps if any, and controlling distributed and redistributed segments to extract the features. Working on low light intensity images make the PFE face challenges and closely depend on the quality of its pre-processing steps. Some papers have suggested many well established NR as well as PFE strategies however only few resources have suggested or mentioned the correlation between them. This paper reviews best approaches of the NR and the PFE with detailed explanation on the suggested correlation. This finding may suggest relevant strategies of the PFE development. With the help of knowledge based reasoning, computational approaches and algorithms, we present the correlation study between the NR and the PFE that can be useful for the development and enhancement of other existing PFE.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time out-of-plane artifact subtraction tomosynthesis imaging using prior CT for scanning beam digital x-ray system

Purpose: The scanning beam digital x-ray system (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis in multiple planes. This system could be used for image guidance during lung nodule biopsy. However, the reconstructed images suffer from strong out-of-plane artifact due to the small tomographic angle of the system. Methods: The authors propose an out-of-plane artifact subtraction tomosynthesis (OPAST) algorithm that utilizes a prior CT volume to augment the run-time image processing. A blur-and-add (BAA) analytical model, derived from the project-to-backproject physical model, permits the generation of tomosynthesis images that are a good approximation to the shift-and-add (SAA) reconstructed image. A computationally practical algorithm is proposed to simulate images and out-of-plane artifacts from patient-specific prior CT volumes using the BAA model. A 3D image registration algorithm to align the simulated and reconstructed images is described. The accuracy of the BAA analytical model and the OPAST algorithm was evaluated using three lung cancer patients’ CT data. The OPAST and image registration algorithms were also tested with added nonrigid respiratory motions. Results: Image similarity measurements, including the correlation coefficient, mean squared error, and structural similarity index, indicated that the BAA model is very accurate in simulating the SAA images from the prior CT for the SBDX system. The shift-variant effect of the BAA model can be ignored when the shifts between SBDX images and CT volumes are within ±10 mm in the x and y directions. The nodule visibility and depth resolution are improved by subtracting simulated artifacts from the reconstructions. The image registration and OPAST are robust in the presence of added respiratory motions. The dominant artifacts in the subtraction images are caused by the mismatches between the real object and the prior CT volume. Conclusions: Their proposed prior CT-augmented OPAST reconstruction algorithm improves lung nodule visibility and depth resolution for the SBDX system.

60 APPLIED LIFE SCIENCES↗

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING↗

A Method to Recognize Anatomical Site and Image Acquisition View in X-ray Images

A method was developed to recognize anatomical site and image acquisition view automatically in 2D X-ray images that are used in image-guided radiation therapy. The purpose is to enable site and view dependent automation and optimization in the image processing tasks including 2D-2D image registration, 2D image contrast enhancement, and independent treatment site confirmation. The X-ray images for 180 patients of six disease sites (the brain, head-neck, breast, lung, abdomen, and pelvis) were included in this study with 30 patients each site and two images of orthogonal views each patient. A hierarchical multiclass recognition model was developed to recognize general site first and then specific site. Each node of the hierarchical model recognized the images using a feature extraction step based on principal component analysis followed by a binary classification step based on support vector machine. Given two images in known orthogonal views, the site recognition model achieved a 99% average F1 score across the six sites. If the views were unknown in the images, the average F1 score was 97%. If only one image was taken either with or without view information, the average F1 score was 94%. The accuracy of the site-specific view recognition models was 100%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereo-Video Data Reduction of Wake Vortices and Trailing Aircrafts

This report presents stereo image theory and the corresponding image processing software developed to analyze stereo imaging data acquired for the wake-vortex hazard flight experiment conducted at NASA Langley Research Center. In this experiment, a leading Lockheed C-130 was equipped with wing-tip smokers to visualize its wing vortices, while a trailing Boeing 737 flew into the wake vortices of the leading airplane. A Rockwell OV-10A airplane, fitted with video cameras under its wings, flew at 400 to 1000 feet above and parallel to the wakes, and photographed the wake interception process for the purpose of determining the three-dimensional location of the trailing aircraft relative to the wake. The report establishes the image-processing tools developed to analyze the video flight-test data, identifies sources of potential inaccuracies, and assesses the quality of the resultant set of stereo data reduction.

Alter-Gartenberg, Rachel↗

Photon detection with parallel asynchronous processing

An approach to photon detection with a parallel asynchronous signal processor is described. The visible or IR photon-detection capability of the silicon p(+)-n-n(+) detectors and the parallel asynchronous processing are addressed separately. This approach would permit an independent analog processing channel to be dedicated to every pixel. A laminar architecture consisting of a stack of planar arrays of the devices would form a 2D array processor with a 2D array of inputs located directly behind a focal-plane detector array. A 2D image data stream would propagate in neuronlike asynchronous pulse-coded form through the laminar processor. Such systems can integrate image acquisition and image processing. Acquisition and processing would be performed concurrently as in natural vision systems. The possibility of multispectral image processing is addressed.

Coon, D. D.↗