Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated power system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Cost and Systems Analysis of Innovative Fuel Resources Concepts

Economically recovered uranium from seawater can have a transformative effect on the way policy makers view the long-term viability of uranium based fuel cycles. Seawater uranium, even when estimated to cost more than terrestrially mined uranium, is integral in establishing an economic backstop, thus reducing uncertainty in future nuclear power costs. While a passive recovery scheme relying on a field of polymer adsorbents prepared via radiation induced grafting has long been considered the leading technology for full scale deployment, non-trivial cost and logistical barriers persist. Consequently, university partners of the nation-wide consortium for seawater uranium recovery have developed variants of this technology, each aiming to address a substantial weakness. The focus of this NEUP project is the economic impacts of the proposed variant technologies. The team at University of Alabama has pursued an adsorbent synthesis method that replaces the synthetic fiber backbone with a natural waste product. Chitin fibers suitable for ligand grafting have been prepared from shrimp shell waste. These environmental benefits could be realized at a comparable cost to the reference fiber so long as the uptake can be increased or the chemical consumption cost decreased.

54 ENVIRONMENTAL SCIENCES↗

A Digital Twin for an Inverter-Based Resource Power Plant: Real-time data streaming unlocks situation awareness

Here, this study presents the development and successful implementation of a digital twin specifically designed for a grid-connected IBR power plant. By integrating a reduced-order model of the IBR system and dynamically updating the grid impedance with real-time data, the digital twin effectively captures and replicates the behavior of the physical system. Its accuracy and reliability are validated through critical test scenarios, including a three-phase fault and a line-tripping event. The results confirm that the digital twin closely emulates its physical counterpart, demonstrating its strong potential for real-time analysis, system monitoring, and predictive decision making in modern power systems.

Digital twins↗

Preparation for an Earth Independent Medical Operations Demonstration using the Tempus ALS™ Medical Device

NASA’s exploration-class missions have severe resource constraints, long return trip durations, significant communication delays and limited resupply opportunities. Validation on the International Space Station (ISS) of medical devices that fit within Earth-Independent Medical Operations (EIMO) systems is a necessary preparation step. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. The Human Research Program’s (HRP) Exploration Medical Capability (ExMC) Element and the Exploration Medical Integrated Product Team (XM-IPT) are planning an ISS technology demonstration to determine the feasibility of including a multifunctional medical device into an EIMO medical system. Demonstration Preparations: The Tempus ALS (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf medical device, with United States Food and Drug Administration clearance and is Conformité Européene marked in Europe. Several thousand units have been sold and are successfully operating in pre-hospital and in remote settings, such as by European Space Agency (ESA) flight surgeons and some of NASA’s commercial partners during post-flight medical operations. The Tempus ALS provides vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature. The device has ultrasound imaging and video laryngoscopy capabilities and has automatic or manual defibrillation modes for treating cardiac arrhythmias. It includes procedural guidance capabilities to assist in the collection of the vital sign measurements and it has various data transmission and report generation features. NASA’s HRP ExMC and XM-IPT are partnering with the ESA to demonstrate the Tempus ALS on ISS, with ESA manifesting the Tempus ALS and its accessories. ESA will compare performance of periodic health status exams and medical contingency drills performed nominally and with the Tempus ALS. NASA’s EIMO demonstration will include the use of Tempus ALS to diagnose a complaint of abdominal pain under increasingly independent circumstances. The caregiver must assess the present illness, collect vital sign measurements, and perform an abdominal ultrasound, under one of three communication situations, including real-time, with a several second delay and with a delay on the order of minutes. Expected Outcomes: Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis instead of separate devices with singular functionalities. Information will also be collected about performance differences as communication delays increase and available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities which takes the EIMO construct into consideration.

Beth Lewandowski↗

A New Modeling Framework for Geothermal Operational Optimization with Machine Learning (GOOML)

Geothermal power plants are excellent resources for providing low carbon electricity generation with high reliability. However, many geothermal power plants could realize significant improvements in operational efficiency from the application of improved modeling software. Increased integration of digital twins into geothermal operations will not only enable engineers to better understand the complex interplay of components in larger systems but will also enable enhanced exploration of the operational space with the recent advances in artificial intelligence (AI) and machine learning (ML) tools. Such innovations in geothermal operational analysis have been deterred by several challenges, most notably, the challenge in applying idealized thermodynamic models to imperfect as-built systems with constant degradation of nominal performance. This paper presents GOOML: a new framework for Geothermal Operational Optimization with Machine Learning. By taking a hybrid data-driven thermodynamics approach, GOOML is able to accurately model the real-world performance characteristics of as-built geothermal systems. Further, GOOML can be readily integrated into the larger AI and ML ecosystem for true state-of-the-art optimization. This modeling framework has already been applied to several geothermal power plants and has provided reasonably accurate results in all cases. Therefore, we expect that the GOOML framework can be applied to any geothermal power plant around the world.

15 GEOTHERMAL ENERGY↗

Survey of Advanced Generation IV Reactor Parameters for Integrated Energy System Modeling Capabilities

This paper is to categorize and characterize advanced Generation IV nuclear reactors that are not water based according to the key parameters for the Integrated Energy Systems (IES) project[1]. A key goal of the IES project is to assess the economic viability of including an advanced nuclear reactor into an IES. The landscape of advanced reactors is heterogeneous: several unique designs with different heat profiles are currently being studied and designed. This report provides a high-level perspective of advanced reactor concepts, including primary loop nuclear output temperatures and operation schemes that could affect secondary side power production or storage. For example, this report addresses the type of thermodynamic system (Brayton, supercritical CO 2 [S-CO 2 ], etc.) and the various pressures and temperatures on the secondary side that are expected to be provided by the various primary side reactor types. Based on these characteristics, it may be possible to determine which type of nuclear power plant could be the most economical for analysis in the IES framework for power production coupled with energy storage and waste heat utilization. The results of this effort will serve as input for model development of various secondary side components, concentrating on off-the-shelf capabilities for current and near future secondary side power generation and heat rejection as simulated in TRANSFORM. Generic models can be created which are agnostic of the nuclear energy supply without violating intellectual property rights of the developer. These models can be used to make informed decisions on the economics of integrating various energy system components with nuclear plant designs. Once complete, conclusions may be drawn regarding (1) the economics, efficiency, and reliability of certain nuclear reactors, (2) certain industry processes and energy storage systems, and (3) prioritization of certain reactor types with the studied industry types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transforming Energy Through Sustainable Mobility: Expanding Low-Carbon Transportation R&D Solutions

As the nation's premier laboratory for cutting-edge transportation decarbonization research and development solutions, the National Renewable Energy Laboratory (NREL) pioneers the creation and deployment of sustainable mobility technologies and strategies, with a focus on slashing transportation sector greenhouse gas emissions and combatting climate change. Trucks, planes, cargo ships, and other difficult-to-decarbonize vehicles are part of this essential transition for the transportation sector, which is currently the nation's largest source of the greenhouse gas emissions. NREL provides the scientific building blocks needed to spur innovation through multifaceted analysis, research, and engineering. This work acts as a catalyst to help industry bring affordable, high-performance, energy-efficient, and low-emission modes of transport and related infrastructure to market sooner. Our researchers collaborate closely with academic, government, and industry partners to design better batteries, drivetrains, and engines. They develop technologies for high-power charging, thermal management, energy storage, and power electronics. They are also reimagining fuels and combustion while creating sustainable lightweight materials. Unbiased expert guidance - backed by credible data and analysis, tools, and scientific rigor - empowers partners to make informed decisions about sustainable transportation. NREL recognizes that communities with limited mobility options face reduced access to employment opportunities, health care, and education, lowering overall quality of life. Alongside partners, NREL experts are creating transportation solutions that meet community-identified needs and increase mobility equity in historically underserved and overburdened communities. Rather than providing a one-size-fits-all solution, we take an interdisciplinary approach to mobility equity that considers the needs and challenges of diverse groups, maximizing benefits at the individual, community, and societal levels.

ADVANCED PROPULSION SYSTEMS↗

Comprehensive Exergy Analysis of Three IGCC Power Plant Configurations with CO 2 Capture

We have conducted comprehensive exergy analyses of three integrated gasification combined cycle with carbon capture and storage (IGCC-CCS) power plant configurations: (1) a baseline model using Selexol™ for H 2 S/CO 2 removal; (2) a modified version that adds a H 2 -selective membrane before the Selexol™ acid gas removal system; and (3) a modified baseline version that uses a CO 2 -selective membrane before the Selexol™ acid gas removal system. While holding the coal input flow rate and the CO 2 captured flow rates constant, it was determined that the H 2 -selective membrane case had a higher net power output (584 MW) compared to the baseline (564 MW) and compared to the CO 2 -selective membrane case (550 MW). Interestingly, the CO 2 -selective membrane case destroyed the least amount of exergy within the power plant (967 MW), compared with the Baseline case (999 MW) and the H 2 -membrane case (972 MW). The main problem with the CO 2 -selective membrane case was the large amount of H 2 (48 MW worth of H 2 chemical exergy) remaining within the supercritical CO 2 that exits the power plant. Finally, regardless of the CO 2 capture process used, the majority of the exergy destruction occurred in the gasifier (305 MW) and gas turbine (~380 MW) subsystems, suggesting that these two areas should be key areas of focus of future improvements.

20 FOSSIL-FUELED POWER PLANTS↗

Identification of Important Phenomena for Light Water Reactors During Heat Transport System Failure Events in Integrated Energy Systems

This work adapts historical literature and existing phenomena identification and ranking tables (PIRT) to be applicable to a novel nuclear power plant (NPP) and chemical or thermal process integrated energy system (IES), particularly focusing on the process heat and heat transport system failure events that are not a concern during normal NPP operation but become vital when an IES is considered. Nuclear energy has been suggested to go beyond base-load applications and be used for hydrogen co-generation systems, amongst other IESs. Prior to the implementation of nuclear IESs, sufficient analysis must be performed on accident events to ensure public safety. The events considered were deemed important because of their potential to damage systems, structures, and components (SSCs). Process thermal events of concern include loss of heat load and temperature transient events. Loss of heat load events were characterized as having high importance and being well understood. Temperature transient events may be further categorized by the cyclic loading and harmonics phenomena. Cyclic loading issues were classified as medium to high importance with knowledge gaps existing regarding fatigue and low power operation, while harmonics phenomena were classified as low importance and are well understood. Heat transport system failure events of concern include intermediate and process heat exchanger failures, mass addition to reactor coolant, ingress of material from thermal manifold/energy storage, and loss of intermediate fluid. Furthermore, these events tended to be of high or medium importance, with some knowledge gaps needing to be filled for individual reactor systems due to unique designs.

Integrated Energy System (IES)↗

The Value of Post-Combustion Carbon Dioxide Capture and Storage Technologies in a World with Uncertain Greenhouse Gas Emissions Constraints

By analyzing how the largest CO2 emitting electricity generating region in the United States, the East Central Area Reliability Coordination Agreement (ECAR), responds to hypothetical constraints on greenhouse gas emissions, the authors demonstrate that there is an enduring role for post combustion CO2 capture technologies. The utilization of pulverized coal with carbon dioxide capture and storage (PC+CCS) technologies is particularly significant in a world where there is significant uncertainty about the future evolution of climate policy and in particular uncertainty about the rate at which the climate policy will become more stringent. The paper’s analysis shows that within this one large, heavily coal-dominated electricity generating region, as much as 20-40 GW of PC+CCS could be in operation before the middle of this century. Depending upon the state of PC+CCS technology development and the evolution of future climate policy, the analysis shows that these CCS systems could be mated to either already existing PC units or PC units that are currently under construction, announced and planned units, as well as PC units that could continue to be built for a number of decades even in the face of a climate policy. In nearly all the cases analyzed here, these PC+CCS generation units are compliments to a much larger deployment of CCS-enabled coal-fired integrated gasification combined cycle (IGCC) power plants. The analysis presented here shows that the combined deployment of PC+CCS and IGCC+CCS units within this one region of the U.S. could result in the potential capture and storage of between 3.2 and 4.9 billion tones of CO2 before the middle of this century in the region’s deep geologic storage formations.

01 COAL, LIGNITE, AND PEAT↗

Preparing Distribution Utilities for Utility-Scale Storage and Electric Vehicles: A Novel Analytical Framework

Emerging distributed energy resources (DERs)—such as solar photovoltaics (PV), battery energy storage systems (BESS), and electric vehicles (EVs)—are expected to increase substantially in India in the coming years following policy-driven targets of the Government of India to modernize its electricity system, reduce greenhouse gas emissions (GHGs), and improve air quality. These emerging technologies can pose challenges to distribution utilities, forcing overhauls in planning and operational practices. They can also create challenges in power system infrastructure planning and cause more frequent system operational violations (e.g., network voltage bounds and loading thresholds) if not properly integrated. The impacts on the localized power distribution grid from these emerging technologies manifest in increased infrastructure investments and erratic shifts in demand patterns. These impacts are not yet well understood, and analytic solutions are not readily available. To address these challenges, the National Renewable Energy Laboratory (NREL), in collaboration with BSES Rajdhani Power Ltd. (BRPL), developed an advanced power distribution system impact analysis framework of BRPL’s distribution system. This framework helps analyze the readiness of the power distribution network to accommodate emerging technologies and the potential opportunities they might introduce. The framework has been predominantly set up to evaluate distributed PV, BESS, and EVs. In this collaboration between NREL and BRPL, we developed and evaluated the framework on two distribution feeders in the BRPL territory for various scenarios of BESS and EVs. BESS are evaluated for their effectiveness on the grid to mitigate present and future feeder overloading scenarios, and they are subsequently analyzed for their costs compared to the costs of traditional upgradation measures. Scenarios include assessing the effects of EV density on grid infrastructure upgrades and interlinking EV management with BESS integration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Integrated energy balance analysis for Space Station Freedom

An integrated simulation model is described which characterizes the dynamic interaction of the energy transport subsystems of Space Station Freedom for given orbital conditions and for a given set of power and thermal loads. Subsystems included in the model are the Electric Power System (EPS), the Internal Thermal Control System (ITCS), the External Thermal Control System (ETCS), and the cabin Temperature and Humidity Control System (THC) (which includes the avionics air cooling, cabin air cooling, and intermodule ventilation systems). Models of the subsystems were developed in a number of system-specific modeling tools and validated. The subsystem models are then combined into integrated models to address a number of integrated performance issues involving the ability of the integrated energy transport system of Space Station Freedom to provide power, controlled cabin temperature and humidity, and equipment thermal control to support operations.

Tandler, John↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid power plant design for low-carbon hydrogen in the United States

In this study, we provide a nationwide techno-economic analysis of clean hydrogen production powered by a hybrid renewable energy plant for over 50,000 locations in the United States. We leverage the open-source Hybrid Optimization Performance Platform (HOPP) tool to simulate the hourly performance of an off-grid wind-solar plant integrated with a 1-GW polymer exchange membrane electrolyzer system. The levelized cost of hydrogen is calculated for varying technology costs, and tax credits to explore cost sensitivities independent of plant design, performance, and site selection. Our findings suggest that strategies for cost reduction include selecting sites with abundant wind resources, complementary wind and solar resources, and optimizing the sizing of wind and solar assets to maximize the hybrid plant capacity factor. These strategies are linked to increased hydrogen production and reduced electrolyzer stack replacements, thereby lowering the overall cost of hydrogen.

08 HYDROGEN↗

Evaluation of Anomaly Detection for Wide-Area Protection Using Cyber Federation Testbed

Cyber physical security research for smart grid is currently one of the nation's top R&D priorities. The existing vulnerabilities in the legacy grid infrastructure make it particularly susceptible to countless cyber-attacks. There is a growing emphasis towards building interconnected, sophisticated federated testbeds to perform realistic experiments by allowing the integration of geographically-dispersed resources in the dynamic cyber-physical environment. In this paper, we present a cyber (network) based federation testbed to validate the performance of an anomaly detector in context of a Wide Area Protection (WAP) security. Specifically, we have utilized the resources available at the Iowa State University Power Cyber (ISU PCL) Laboratory to emulate the substation and local center networks; and the US Army Research Laboratory (ARL); to emulate the regional control center network. Initially, we describe a hardware-in-the loop based experimental setup for implementing data integrity attacks on an IEEE 39 bus system. We then perform network packet analysis focusing on latency and bandwidth as well as evaluate the performance of a decision tree based anomaly detector in measuring its ability to identify different attacks. Our experimental results reveal the computed wide area network latency; bandwidth requirement for minimum packet loss; and successful performance of the anomaly detector. Our studies also highlight the conceptual architecture necessary for developing the federated testbed, inspired by the NASPI network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calorimetric and magnetic study for Ni{sub 50}Mn{sub 36}In{sub 14} and relative cooling power in paramagnetic inverse magnetocaloric systems

The non-stoichiometric Heusler alloy Ni{sub 50}Mn{sub 36}In{sub 14} undergoes a martensitic phase transformation in the vicinity of 345 K, with the high temperature austenite phase exhibiting paramagnetic rather than ferromagnetic behavior, as shown in similar alloys with lower-temperature transformations. Suitably prepared samples are shown to exhibit a sharp transformation, a relatively small thermal hysteresis, and a large field-induced entropy change. We analyzed the magnetocaloric behavior both through magnetization and direct field-dependent calorimetry measurements. For measurements passing through the first-order transformation, an improved method for heat-pulse relaxation calorimetry was designed. The results provide a firm basis for the analytic evaluation of field-induced entropy changes in related materials. An analysis of the relative cooling power (RCP), based on the integrated field-induced entropy change and magnetizing behavior of the Mn spin system with ferromagnetic correlations, shows that a significant RCP may be obtained in these materials by tuning the magnetic and structural transformation temperatures through minor compositional changes or local order changes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GridCoPilot for Thermal Events: An LLM-Based Platform for Power Grid Reliability Analysis

Large Language Models show promise for translating natural language into database queries, but deploying such systems in safety-critical domains requires high reliability. We present an application of GridCoPilot to thermal event analysis (heatwaves and coldwaves) that affect power grid reliability. Our approach uses a LangChain SQL Agent to translate natural language queries into auditable SQL statements, with deterministic visualization routines that parse the structured query results. We introduce structural framing as a design principle, we integrate a NERC-region-level event library with county-level meteorology and decompose the combined data into three relational tables (event metadata, county-level event details, and a county-to-NERC subregion mapping), using prompt-guided joins to direct the model toward correct multi-table queries. For two core analytical patterns (identifying worst events by region and by region-year), the system achieved 100% SQL accuracy across all 16 NERC subregions and both event types (64 queries total). These results validate the approach for target use cases, though performance on diverse natural language formulations requires further investigation. We discuss design trade-offs, failure modes including JSON output truncation, and pathways for extending this approach to other hazard domains.

24 POWER TRANSMISSION AND DISTRIBUTION↗