Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lasers, Computer science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Shake-Down Spectroscopy as State- and Site-Specific Probe of Ultrafast Chemical Dynamics

Tracking the multifarious ultrafast electronic and structural changes occurring in a molecule during a photochemical transformation is a challenging endeavor that benefits from recent experimental and computational progress in time-resolved techniques. Measurements of valence electronic states, which provide a global picture of the bonding structure of the molecule, and core electronic states, which provide insight into the local environment, traditionally require different approaches and are often studied separately. Here, we demonstrate that X-ray pulses from a seeded free-electron laser (FEL) enable the measurement of high-resolution, time-resolved X-ray photoelectron spectra (XPS) that capture weak satellite states resulting from shake-down processes in a valence-excited molecule. This approach effectively combines the advantages of both valence- and core-state investigations. We applied this method to investigate photoexcited CS2 molecules, where the role of internal conversion (IC) and intersystem crossing (ISC) in determining the predissociation dynamics is controversial. We present XPS spectra from photoexcited CS2, obtained at the FERMI FEL. High-resolution measurements, compared to the corresponding spectra obtained from accurate multireference quantum chemical calculations, reveal that shake-down satellite channels are highly sensitive to both valence electronic and geometric changes. Previous studies of the predissociation dynamics have led to uncertain assignments of the branching between singlet and triplet excited states. We derive a propensity rule that demonstrates the spin-selectivity of the shake-downs. This selectivity allows us to unequivocally assign contributions from the bright and dark singlet excited states, with populations tracked along the predissociation dynamic pathway.

Thompson, Henry J. [Univ. of Southampton (United K↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

TH-CD-201-09: High Spatial Resolution Absorbed Dose to Water Measurements Using Optical Calorimetry in Megavoltage External Beam Therapy

Purpose: To develop and implement a high spatial resolution calorimeter methodology to measure absorbed dose to water (ADW) using phase shifts (PSs) of light passing through a water phantom and to compare measurements with theoretical calculations. Methods: Radiation-induced temperature changes were measured using the PSs of a He-Ne laser beam passing through a (10×10×10) cm{sup 3} water phantom. PSs were measured using a Michelson interferometer and recording the time-dependent fringe patterns on a CCD camera. The phantom was positioned at the center of the radiation field. A Varian 21EX was used to deliver 500 MU from a 9 MeV beam using a (6×6) cm{sup 2} cone. A 127cm SSD was used and the PSs were measured at depths ranging from of 1.90cm to 2.10cm in steps of 0.05cm by taking profiles at the corresponding rows across the image. PSs were computed by taking the difference between pre- and post-irradiation image frames and then measuring the amplitude of the resulting image profiles. An amplitude-to-PS calibration curve was generated using a piezoelectric transducer to mechanically induce PSs between 0.05 and 1.50 radians in steps of 0.05 radians. The temperature dependence of the refractive index of water at 632.8nm was used to convert PSs to ADW. Measured results were compared with ADW values calculated using the linac output calibration and commissioning data. Results: Milli-radian resolution in PS measurement was achieved using the described methodology. Measured radiation-induced PSs ranged from 0.10 ± 0.01 to 0.12 ± 0.01 radians at the investigated depths. After converting PSs to ADW, measured and calculated ADW values agreed within the measurement uncertainty. Conclusion: This work shows that interferometer-based calorimetry measurements are capable of achieving sub-millimeter resolution measuring 2D temperature/dose distributions, which are particularly useful for characterizing beams from modalities such as SRS, proton therapy, or microbeams.

60 APPLIED LIFE SCIENCES↗

femto-PIXAR: a self-supervised neural network method for reconstructing femtosecond X-ray free electron laser pulses

X-ray Free Electron Lasers (X-FELs) operate in a wide range of lasing configurations for a broad variety of scientific applications at ultrafast time-scales such as structural biology, materials science, and atomic and molecular physics. Shot-by-shot characterization of the X-FEL pulses is crucial for analysis of many experiments as well as tuning the X-FEL performance. However, for the weak pulses found in advanced configurations, e.g. those needed for coherent, two-pulse studies of quantum materials, there is no current method for reliably resolving pulse profiles. Here we show that a physics-based U-net model can reconstruct the individual pulse power profiles for sub-picosecond pulse separation without the need for simulations. Using experimental data from weak X-FEL pulse pairs, we demonstrate we can learn the pulse characteristics on a shot-by-shot basis when conventional methods fail.

43 PARTICLE ACCELERATORS↗

Digital Elevation Model, 0.5 m, Barrow Environmental Observatory, Utqiagvik (Barrow), Alaska, 2012

This 0.5m horizontal resolution digital elevation model (DEM) was developed from Airborne Laser Altimetry flown by Aerometric Inc, now know as Quantum Spatial, Inc. on August 12, 2012. One Mission was flown and the data jointly processed with Los Alamos National Laboratory (LANL) personnel to produce a 0.5m DEM covering a region approximately 2.8km wide and 12.5km long extending from the coast above North Salt Lagoon to south of Gas Well Road. This DEM encompasses a diverse range of hyrdrologic, geomorphic, geophysical and biological features typical of the Barrow Peninsula. Vertical accuracy at the 95% confidence interval was computed as 0.145m. The coordinate system, datum, and geoid for this DEM are UTM Zone 4N, NAD83 (2011), NAVD88 (GEOID09). This dataset includes one .tif file and one .pdf file.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-557: Measuring Neutron Activation of Cardiac Devices Irradiated During Proton Therapy Using Indium Foils

Purpose: Measuring Neutron Activation of Cardiac devices Irradiated during Proton Therapy using Indium Foils Methods: The foils had dimensions of 25mm x 25mm x 1mm. After being activated, the foils were placed in a Canberra Industries well chamber utilizing a NaI(Tl) scintillation detector. The resulting gamma spectrum was acquired and analyzed using Genie 2000 spectroscopy software. One activation foil was placed over the upper, left chest of RANDO where a pacemaker would be. The rest of the foils were placed over the midline of the patient at different distances, providing a spatial distribution over the phantom. Using lasers and BBs to align the patient, 200 MU square fields were delivered to various treatment sites: the brain, the pancreas, and the prostate. Each field was shot at least a day apart, giving more than enough time for activity of the foil to decay (t1=2 = 54.12 min). Results: The net counts (minus background) of the three aforementioned peaks were used for our measurements. These counts were adjusted to account for detector efficiency, relative photon yields from decay, and the natural abundance of 115-In. The average neutron flux for the closed multi-leaf collimator irradiation was measured to be 1.62 x 106 - 0.18 x 106 cm2 s-1. An order of magnitude estimate of the flux for neutrons up to 1 keV from Diffenderfer et al. gives 3 x 106 cm2 s-1 which does agree on the order of magnitude. Conclusion: Lower energy neutrons have higher interaction cross-sections and are more likely to damage pacemakers. The thermal/slow neutron component may be enough to estimate the overall risk. The true test of the applicability of activation foils is whether or not measurements are capable of predicting cardiac device malfunction. For that, additional studies are needed to provide clinical evidence one way or the other.

07 ISOTOPE AND RADIATION SOURCES↗

Silicon nitride stress-optic microresonator modulator for optical control applications

Modulation-based control and locking of lasers, filters and other photonic components is a ubiquitous function across many applications that span the visible to infrared (IR), including atomic, molecular and optical (AMO), quantum sciences, fiber communications, metrology, and microwave photonics. Today, modulators used to realize these control functions consist of high-power bulk-optic components for tuning, sideband modulation, and phase and frequency shifting, while providing low optical insertion loss and operation from DC to 10s of MHz. In order to reduce the size, weight and cost of these applications and improve their scalability and reliability, modulation control functions need to be implemented in a low loss, wafer-scale CMOS-compatible photonic integration platform. The silicon nitride integration platform has been successful at realizing extremely low waveguide losses across the visible to infrared and components including high performance lasers, filters, resonators, stabilization cavities, and optical frequency combs. Yet, progress towards implementing low loss, low power modulators in the silicon nitride platform, while maintaining wafer-scale process compatibility has been limited. Here we report a significant advance in integration of a piezo-electric (PZT, lead zirconate titanate) actuated micro-ring modulation in a fully-planar, wafer-scale silicon nitride platform, that maintains low optical loss (0.03 dB/cm in a 625 µm resonator) at 1550 nm, with an order of magnitude increase in bandwidth (DC - 15 MHz 3-dB and DC - 25 MHz 6-dB) and order of magnitude lower power consumption of 20 nW improvement over prior PZT modulators. The modulator provides a >14 dB extinction ratio (ER) and 7.1 million quality-factor (Q) over the entire 4 GHz tuning range, a tuning efficiency of 162 MHz/V, and delivers the linearity required for control applications with 65.1 dB·Hz 2/3 and 73.8 dB·Hz 2/3 third-order intermodulation distortion (IMD3) spurious free dynamic range (SFDR) at 1 MHz and 10 MHz respectively. We demonstrate two control applications, laser stabilization in a Pound-Drever Hall (PDH) lock loop, reducing laser frequency noise by 40 dB, and as a laser carrier tracking filter. This PZT modulator design can be extended to the visible in the ultra-low loss silicon nitride platform with minor waveguide design changes. This integration of PZT modulation in the ultra-low loss silicon nitride waveguide platform enables modulator control functions in a wide range of visible to IR applications such as atomic and molecular transition locking for cooling, trapping and probing, controllable optical frequency combs, low-power external cavity tunable lasers, quantum computers, sensors and communications, atomic clocks, and tunable ultra-low linewidth lasers and ultra-low phase noise microwave synthesizers.

Wang, Jiawei (ORCID:0000000257965220)↗

Correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition using neutron diffraction and imaging techniques

In a directed energy deposition (DED) process, the energy density deposited into the materials drives the structure and properties. The energy density is influenced by several printing parameters, such as laser power, hatch spacing, scanning speed, etc. In this study, 316L stainless steels samples were fabricated with varying hatch spacing aiming to induce variations in sample microstructure and properties. A combination of techniques including engineering neutron diffraction, neutron computed tomography, and tensile testing, were employed to correlate the structure and macroscopic properties. Porosity was predominantly observed at the bottom of the deposited materials and was effectively reduced by decreased hatch spacing. Correlatively, compressive residual stress was observed at the bottom of the specimens, while internal stress is largely determined by the hatch spacing. The residual stress in general decreases as the hatch spacing decreases. The maximum ultimate tensile strength (UTS) was found to increase from 517.4 to 528.6 MPa with a strain increased from 0.847 to 0.897 as the hatch spacing decreased from 0.45 to 0.42 mm. However, further increase in energy density by reducing the hatch spacing resulted in a significant decrease in UTS (as low as 452 MPa). This work provides new insights from bulk non-destructive techniques into correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition.

316L stainless steel↗

Exploring the fragmentation efficiency of proteins analyzed by MALDI-TOF-TOF tandem mass spectrometry using computational and statistical analyses

Matrix-assisted laser desorption/ionization time-of-flight-time-of-flight (MALDI-TOF-TOF) tandem mass spectrometry (MS/MS) is a rapid technique for identifying intact proteins from unfractionated mixtures by top-down proteomic analysis. MS/MS allows isolation of specific intact protein ions prior to fragmentation, allowing fragment ion attribution to a specific precursor ion. However, the fragmentation efficiency of mature, intact protein ions by MS/MS post-source decay (PSD) varies widely, and the biochemical and structural factors of the protein that contribute to it are poorly understood. With the advent of protein structure prediction algorithms such as Alphafold2, we have wider access to protein structures for which no crystal structure exists. In this work, we use a statistical approach to explore the properties of bacterial proteins that can affect their gas phase dissociation via PSD. We extract various protein properties from Alphafold2 predictions and analyze their effect on fragmentation efficiency. Our results show that the fragmentation efficiency from cleavage of the polypeptide backbone on the C-terminal side of glutamic acid (E) and asparagine (N) residues were nearly equal. In addition, we found that the rearrangement and cleavage on the C-terminal side of aspartic acid (D) residues that result from the aspartic acid effect (AAE) were higher than for E- and N-residues. From residue interaction network analysis, we identified several local centrality measures and discussed their implications regarding the AAE. We also confirmed the selective cleavage of the backbone at D-proline bonds in proteins and further extend it to N-proline bonds. Finally, we note an enhancement of the AAE mechanism when the residue on the C-terminal side of D-, E- and N-residues is glycine. To the best of our knowledge, this is the first report of this phenomenon. Our study demonstrates the value of using statistical analyses of protein sequences and their predicted structures to better understand the fragmentation of the intact protein ions in the gas phase.

59 BASIC BIOLOGICAL SCIENCES↗

CS651 Computer Systems Security Foundations 3d Imagination Cyber Security Management Plan

3d Imagination is a new company that bases its business on selling and improving 3d open source related hardware. The devices that they sell include 3d imagers, 3d printers, pick and place machines and laser etchers. They have a fast company intranet for ease in sharing, storing and printing large, complex 3d designs. They have an employee set that requires a variety of operating systems including Windows, Mac and a variety of Linux both for running business services as well as design and test machines. There are a wide variety of private networks for testing transfer rates to and from the 3d devices, without interference with other network tra c. They do video conferencing conferencing with customers and other designers. One of their machines is based on the project found at delta.firepick.org(Krassenstein, 2014; Biggs, 2014), which in future, will perform most of those functions. Their devices all include embedded systems, that may have full blown operating systems. Most of their systems are designed to have swappable parts, so when a new technology is born, it can be quickly adopted by people with 3d Imagination hardware. This company is producing a fair number of systems and components, however to get the funding they need to mass produce quality parts, so they are preparing for an IPO to raise the funds they need. They would like to have a cyber-security audit performed so they can give their investors con dence that they are protecting their data, customers information and printers in a proactive manner.

97 MATHEMATICS AND COMPUTING↗

OptRAM: In-silico strain design via integrative regulatory-metabolic network modeling

The ultimate goal of metabolic engineering is to produce desired compounds on an industrial scale in a cost effective manner. To address challenges in metabolic engineering, computational strain optimization algorithms based on genome-scale metabolic models have increasingly been used to aid in overproducing products of interest. However, most of these strain optimization algorithms utilize a metabolic network alone, with few approaches providing strategies that also include transcriptional regulation. Moreover previous integrated approaches generally require a pre-existing regulatory network. In this study, we developed a novel strain design algorithm, named OptRAM (Optimization of Regulatory And Metabolic Networks), which can identify combinatorial optimization strategies including overexpression, knockdown or knockout of both metabolic genes and transcription factors. OptRAM is based on our previous IDREAM integrated network framework, which makes it able to deduce a regulatory network from data. OptRAM uses simulated annealing with a novel objective function, which can ensure a favorable coupling between desired chemical and cell growth. The other advance we propose is a systematic evaluation metric of multiple solutions, by considering the essential genes, flux variation, and engineering manipulation cost. We applied OptRAM to generate strain designs for succinate, 2,3-butanediol, and ethanol overproduction in yeast, which predicted high minimum predicted target production rate compared with other methods and previous literature values. Moreover, most of the genes and TFs proposed to be altered by OptRAM in these scenarios have been validated by modification of the exact genes or the target genes regulated by the TFs, for overproduction of these desired compounds by in vivo experiments cataloged in the LASER database. Particularly, we successfully validated the predicted strain optimization strategy for ethanol production by fermentation experiment. As a result, OptRAM can provide a useful approach that leverages an integrated transcriptional regulatory network and metabolic network to guide metabolic engineering applications.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring the Neutron Substructure with Advanced Polarized Helium-3 Targets (Or: How I Learned to Stop Worrying and Love Spectroscopy)

As we seek to understand the smallest, physical aspects of our universe, we cannot simply rely on our senses to probe the world around us as we did in the past. The smallest physical elements of our universe behave in strange, probabilistic ways and are completely invisible to the naked eye/ear/etc. So, we design clever experiments (such as scattering experiments) to probe these minute realms. Then, just as with the larger, observable world, we devise models and equations to describe what we think is happening. Due to the nature of the physical universe at the quantum scale and with the aid of symmetries such as Lorentz invariance, we can write down equations that describe the scattering, but the expressions contain functions, which we call ?form factors? and ?structure functions?, that we cannot compute from first principles. We can, however, formulate models that make predictions for these functions. By comparing our predictions with the observed data, we can gain insight into the validity of our models and thus a better physical understanding of what is happening at these minuscule scales. Studying the constituents inside of the nucleus of an atom adds another layer of difficulty if we can?t remove those components from the nucleus. This is the case with the neutron. When not bound in the nucleus with protons and other neutrons, the neutron will decay into a proton after about 15 minutes. So, we?re forced to study the neutron while it is still bound in the nucleus of an atom such as helium-3 (3He). For the last 1,000 years (rounding up), our group has developed high quality, polarized 3He targets made of an aluminosilicate glass. These targets are made in order to perform experiments at Jefferson Lab (JLab), experiments which let us determine the form factors and structure functions of the neutron by scattering polarized electrons from polarized neutrons (or rather polarized 3He). The specific experiments reported on in this thesis push the bounds of our understanding of the internal structure of the neutron. Good science is often about pushing experimental techniques to a new level. Toward that goal we study our polarized 3He targets both to advance the technology and to choose the best ones for our experiments. We do this using a process called nuclear magnetic resonance (NMR) to gauge the maximum polarization of a target and how fast the polarization decays with time. While these tests primarily provide us information that make analysis of our experimental scattering data possible, they also let us determine whether or not a target-cell is useful or even, dare I say, of spectacular quality. Our latest targets utilize a novel convection design allowing 3He to be polarized and quickly moved in front of the electron-beam, making it possible to use larger targets with higher electron-beam currents than ever before. This means more electrons scatter and we get more data. And by studying our targets in detail prior to using them in our experiments, we have found techniques to take effects which could have been detrimental to target quality and turn them to our advantage! It?s a real case of making lemonade out of lemons. We also use laser spectroscopy to study the absorption lines of alkali-metals in the target (potassium and rubidium, specifically). We add these alkali-metals to our target to facilitate polarizing the 3He. We can use the measurement of these pressure broadened absorption lines to determine the 3He density inside of the target with great precision. Historically, we understood the width of these lines would be dependent on the temperature of the target. Specifically, if I raise the temperature, the width should get bigger. I found that was not the case, which was very confusing at first, though very exciting now that I realize the data are self-consistent and suggestive of unexpected behavior. This thesis details the development of high quality, glass, polarized 3He targets for the 2020 An 1 /dn 2 and 2023 Gn E experiments, which utilized the first 3He convection targets and broke records in target quality. This thesis also covers the initial development of metal windows for the next-generation of 3He target-cells. Finally, this thesis documents the temperature dependence of the width of potassium (K) and rubidium (Rb) absorption lines as measured with laser spectroscopy.

Jantzi, Christopher↗

Organization of the 16th Advanced Accelerator Concepts (AAC) Workshop by Stanford University

Essentially all we know today and will learn in the future about the fundamental nature of matter is derived from probing it with directed beams of particles such as electrons, protons, neutrons, heavy ions, and photons. The resulting ability to “see” the building blocks of matter has had an immense impact on society and our standard of living. Over the last century, particle accelerators have changed the way we look at nature and the universe we live in and have become an integral part of the Nation’s technical infrastructure. Today, particle accelerators are essential tools of modern science and technology. The cost and capabilities of accelerators would be greatly enhanced by breakthroughs in acceleration methods and technology. For the last 32 years, the Advanced Accelerator Concepts (AAC) Workshop has acted as the focal point for discussion and development of the most promising acceleration physics and technology. It is a particularly effective forum where the discussion is leveraged and promoted by the unique and demanding feature of the AAC Workshop: the working group structure, in which participants are asked to consider their contributions in terms of even larger problems to be solved. The 16th Advanced Accelerator Concepts (AAC2014) Workshop was organized by Stanford University from July 13 - 18, 2014 at the Dolce Hays Mansion in San Jose, California. The conference had a record 282 attendees including 62 students. Attendees came from 11 countries representing 66 different institutions. The workshop format consisted of plenary sessions in the morning with topical leaders from around the world presenting the latest breakthroughs to the entire workshop. In the late morning and afternoons attendees broke out into eight different working groups for more detailed presentations and discussions that were summarized on the final day of the workshop. In addition, there were student tutorial presentations on two afternoons to provide in depth education and training for the next generation of accelerator scientists. This is the final technical report on the organization and outcome of AAC2014.

43 PARTICLE ACCELERATORS↗

Scalable in situ non-destructive evaluation of additively manufactured components using process monitoring, sensor fusion, and machine learning

Laser Powder Bed Fusion (L-PBF) Additive Manufacturing (AM) is among the metal 3D printing technologies most broadly adopted by the manufacturing industry. However, the current industry qualification paradigm for critical-application L-PBF parts relies heavily on expensive non-destructive inspection techniques, which significantly limits the use-cases of L-PBF. In situ monitoring of the process promises a less expensive alternative to ex situ testing, but existing sensor technologies and data analysis techniques struggle to detect sub-surface flaws (e.g., porosity and cracking) on production-scale L-PBF printers. In this work, an in situ NDE (INDE) system was engineered to detect subsurface flaws detected in X-Ray Computed Tomography (XCT) directly from process monitoring data. A multilayer, multimodal data input allowed the INDE system to detect numerous subsurface flaws in the size range of 200–1000µm using a novel human-in-the-loop annotation procedure. Furthermore, a framework was established for generating probability-of-detection (POD) and probability-of-false-alarm (PFA) curves compliant with NDE standards by systematically comparing instances of detected subsurface flaws to post-build XCT data. Here, we also introduce for the first time in the AM in situ sensing literature the a 90/95 – the flaw size corresponding to a 90% detection rate on the lower 95% confidence interval of the POD curve. The INDE system successfully demonstrated POD capabilities commensurate with traditional NDE methods. Traditional ML performance metrics were also shown to be inadequate for assessing the ability of the INDE system’s flaw detection performance. It is the hope of the authors that future studies will adopt the POD and PFA approach outlined here to provide better insight into the utility of process monitoring for AM.

36 MATERIALS SCIENCE↗

Spectra of clinical CT scanners using a portable Compton spectrometer

Purpose: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. Methods: In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. Results: The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. Conclusions: A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners.

07 ISOTOPE AND RADIATION SOURCES↗

Unravelling Microstructure Selection in an Additively Manufactured Eutectic High‐Entropy Alloy

High-entropy alloys (HEAs) are promising candidates for advanced structural applications due to their excellent mechanical properties. Additive manufacturing (AM), with its rapid solidification conditions, enables the creation of unique nonequilibrium microstructures. To fully leverage the synergy between AM and HEAs, understanding how processing affects structure and properties is essential. Here, how solidification rate influences microstructure evolution and phase transformation pathway in laser additively manufactured AlCrFe2Ni2 eutectic HEAs is investigated. By increasing the laser scan speed and hence the solidification rate, distinct solidification modes evolving from coupled eutectic to anomalous eutectic and eventually to single-phase solidification are revealed. These transitions result in distinct microstructures and a wide range of mechanical properties. Thermodynamic modeling and molecular dynamics simulations reveal that low cooling rates allow for sufficient atomic diffusion and phase separation, facilitating coupled eutectic growth. In contrast, rapid cooling suppresses diffusion and destabilizes the solid–liquid interface, promoting anomalous or single-phase solidification. This integrated experimental and computational approach provides a multiscale understanding of solidification mechanisms in HEAs and underscores how kinetic effects can over-ride thermodynamic predictions under nonequilibrium conditions. Furthermore, these results demonstrate that AM can serve as a powerful tool to design HEAs with tailored microstructures and properties.

36 MATERIALS SCIENCE↗

The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1

This article describes the Laser calibration system of the ATLAS hadronic Tile Calorimeter that has been used during the run 1 of the LHC . First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for the end-caps. Lastly, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-204: Improving Multiple Isocenter Coincidence: Elekta Beam Modulator with HexaPOD Six Degrees Couchtop

Purpose: With evolution from frame-based to image-guided SRS/SRT technique, the coincidence of multiple isocenters must be within a tight tolerance: MV, kV, table mechanical, and, in this case, HexaPOD 6° patient positioning system. Reported here is a method for improving the effectiveness of an isocenter alignment procedure which ultimately led to isocenter coincidence on an Elekta Beam Modulator LINAC equipped with 4 mm MLC leaves and a fixed secondary jaw to within a radius of 1mm. Methods: Utilizing a self-leveling laser, the Elekta ball (BB) bearing phantom (8mm steel ball), the Modus QA Isocenter Cube software, and a colleague-provided isocenter alignment method, the kV, table mechanical, and HexaPOD isocenters were localized to the MV isocenter. Isocenter coincidence was tested using the Isocenter Cube from Modus QA, brought to kV isocenter using CBCT and the HexaPOD system. MV images were taken at various gantry, collimator, and couch angles and then analyzed with the aforementioned software to determine coincidence of the 5mm steel ball at cube center with MV isocenter. To improve overall coincidence, two errors were addressed iteratively: (1) LINAC mechanical and radiation isocenter coincidence allowing each isocenter volume to have similar variations during gantry and collimator rotation and (2) collimator rotational walkout which reduced the size of both mechanical and radiation isocenters. Beam steering was performed to bring MV isocenter closer to mechanical and collimator walkout was adjusted by physically shifting the MLC bank. Initial procedures were repeated to align all isocenters and perform regular checks for consistency. Results: Post-initial alignment revealed a maximum diameter of 1.8mm for MV isocenter and maximum isocenter alignment error of up to 1.22mm radius which improved to roughly 1.0mm MV isocenter diameter and <0.71mm radius alignment error with a consistency within 0.25mm. Conclusion: With the methods described, all isocenters were brought into alignment within a radius of 1mm.

07 ISOTOPE AND RADIATION SOURCES↗