Search NASA⌕ Search

SEARCH · Search NASA

Results for “Level Up”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Level-1C Product from AIRS: Principal Component Filtering

The Atmospheric Infrared Sounder (AIRS), launched on the EOS Aqua spacecraft on May 4, 2002, is a grating spectrometer with 2378 channels in the range 3.7 to 15.4 microns. In a grating spectrometer each individual radiance measurement is largely independent of all others. Most measurements are extremely accurate and have very low noise levels. However, some channels exhibit high noise levels or other anomalous behavior, complicating applications needing radiances throughout a band, such as cross-calibration with other instruments and regression retrieval algorithms. The AIRS Level-1C product is similar to Level-1B but with instrument artifacts removed. This paper focuses on the "cleaning" portion of Level-1C, which identifies bad radiance values within spectra and produces substitute radiances using redundant information from other channels. The substitution is done in two passes, first with a simple combination of values from neighboring channels, then with principal components. After results of the substitution are shown, differences between principal component reconstructed values and observed radiances are used to investigate detailed noise characteristics and spatial misalignment in other channels.

Noise Equivalent delta Temperature (NEdT)↗

Flood Hazard Assessment from Storm Tides, Rain and Sea Level Rise for a Tidal River Estuary

Cities and towns along the tidal Hudson River are highly vulnerable to flooding through the combination of storm tides and high streamflows, compounded by sea level rise. Here a three-dimensional hydrodynamic model, validated by comparing peak water levels for 76 historical storms, is applied in a probabilistic flood hazard assessment. In simulations, the model merges streamflows and storm tides from tropical cyclones (TCs), offshore extratropical cyclones (ETCs) and inland "wet extratropical" cyclones (WETCs). The climatology of possible ETC and WETC storm events is represented by historical events (1931-2013), and simulations include gauged streamflows and inferred ungauged streamflows (based on watershed area) for the Hudson River and its tributaries. The TC climatology is created using a stochastic statistical model to represent a wider range of storms than is contained in the historical record. TC streamflow hydrographs are simulated for tributaries spaced along the Hudson, modeled as a function of TC attributes (storm track, sea surface temperature, maximum wind speed) using a statistical Bayesian approach. Results show WETCs are important to flood risk in the upper tidal river (e.g., Albany, New York), ETCs are important in the estuary (e.g., New York City) and lower tidal river, and TCs are important at all locations due to their potential for both high surge and extreme rainfall. The raising of floods by sea level rise is shown to be reduced by approximately 30-60 percent at Albany due to the dominance of streamflow for flood risk. This can be explained with simple channel flow dynamics, in which increased depth throughout the river reduces frictional resistance, thereby reducing the water level slope and the upriver water level.

Tidal river↗

Maldives Climate II: Evaluating the Potential Impacts of Sea Level Rise on Human Development and Coastal Infrastructure

The Republic of the Maldives is a low-lying island nation in the Indian Ocean which has experienced rapid urbanization, landcover changes, and sea level rise over recent years. The growth of tourism, coastal erosion, and urbanization have all driven land reclamation efforts across many islands. As in-situ landcover change monitoring has proven difficult across the vast archipelago, the NASA DEVELOP team collaborated with the Maldives Ministry of Environment, Climate Change, and Technology; USAID; and the U.S. Department of State, to utilize Earth observations to predict sea level rise impacts on coastal infrastructure. The team used a supervised classification algorithm within Google Earth Engine to create land use maps and time series analyses of nine islands and atolls using imagery from Landsat 7 Enhanced Thematic Mapper Plus, Landsat 8 Operational Land Imager, Sentinel-2 Multispectral Instrument, and PlanetScope, covering a combined period of 2000 through 2023. Additionally, the team projected coastal inundation with a modified deterministic Bathtub model utilizing elevation data from CoastalDEM and 2050-2100 Shared Socioeconomic Pathway scenarios identified in the NASA Sea Level Rise Projection Tool. The team found that islands undergoing urban growth experienced a 23% decrease in vegetation between 2014 and 2022. Furthermore, the model predicted that 51–57% of the study area’s-built environment has a chance of inundation by 2100 under the low and high sea level scenarios. These analyses demonstrate how remote sensing can be used to both track land use changes over time and project how coastlines will be affected by sea level rise.

remote sensing↗

Integrated Computational Materials Engineering (ICME) Capability Maturity Levels for Ecosystems Enabling Digital Transformation

Digital engineering (DE) and integrated computational materials engineering (ICME) are widely recognized as critical enablers of faster, more affordable, and more reliable aerospace systems. However, many organizations have struggled to realize the promised return on investment (ROI) from digital initiatives. A primary reason is the absence of a shared, decision-focused framework that distinguishes simple digitization of existing workflows from true digital transformation that fundamentally changes how engineering decisions are made. This paper introduces an ICME capability maturity framework that fills this gap. The framework defines six cumulative ICME capability maturity levels (CMLs), explicitly tied to decision authority, engineering integration, optimization, and uncertainty management across material, process, structure, and performance scales. It is designed to complement established readiness metrics such as technology readiness levels (TRLs), manufacturing readiness levels (MRLs), and integration readiness levels (IRLs), by addressing a missing dimension: the conditions required for model-informed decision authority across scales. A unifying figure and capability table illustrate the six-level ICME Capability Maturity Framework, showing how organizations progress from digitization—with limited or negative ROI—to true digital transformation, where ICME-enabled workflows deliver measurable improvements in decision quality, cycle time, risk reduction, and reuse. The framework is intended for both technical practitioners and executive leadership, providing a common language to assess current state, guide roadmaps, align software ecosystem investments, and set realistic expectations for digital transformation outcomes. A regulatory-relevant statement clarifying the relationship between ICME capability and existing certification frameworks is provided.

ICME↗

Application of spectral summing to suspect low level debris drums at Los Alamos National Laboratory

The spectral summing technique developed by Pajarito Scientific Corporation (PSC) is a unique modeling technique that is being employed by the Waste Disposition Project - Low Level Waste Disposal (WDP-LLWD) Group at Los Alamos National Laboratory (LANL). This technique is being used to disposition low-level radioactive waste that has dropped out of the transuranic (TRU) category and has no place to go unless it can be proven to be LLW and not TRU. The TRU program at LANL run by Mobile Characterization Services (MCS) employs two High Efficiency Neutron Counters (HENC) with built-in gamma assay systems to assay radioactive waste for shipment and disposal as TRU waste at the Waste Isolation Pilot Plant (WIPP) at Carlsbad, New Mexico. As well as being certified for WIPP assays, the HENC systems can also be used for low-level waste assays for disposal at LANL or off-site disposal facilities, such as the Nevada Test Site (NTS). Some of the waste processed through the HENC systems cannot be confirmed TRU due to the absence of detected TRU alpha emitters above the TRU cutoff of 100 nCi/g. This waste becomes suspect low-level waste (SLLW). In many cases, the waste also can't be classified as LLW because the minimum detectable activity (MDA) of TRU radionuclides is above the 100 nCi/g level. These wastes that do not have enough detectable TRU activity to be classified as TRU waste and have too high a MDA to be classified as LLW enter a radioactive waste characterization limbo that prevents their dispositioning as either TRU waste or LLW. Spectral summing allows an experienced gamma spectroscopy analyst to add the HENC gamma spectra of a number of similar waste items together to form a consolidated (summed) spectrum. This summed spectrum contains the assay results of the group of items rather than the individual item, and gamma peaks that were not discernable in the individual spectra become quantifiable in the summed spectrum. The group of waste items can then be properly classified as LLW based on the summed spectrum and valid assay values can be assigned for disposal. This technique is being successfully used to dispose of LLW debris drums from LANL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New high-spin level schemes and excitation modes of 117,118,119,120,122 Cd

High-spin level schemes of {sup 117,118,119,120,122}Cd are expanded by analyzing our high-statistics triple and higher-fold coincidence events of prompt fission {gamma} rays from {sup 252}Cf at Gammasphere. Spin/parity assignments were made based on new {gamma}-{gamma} angular correlation measurements and level systematics in the neighboring isotopes. Stretch-aligned band structures observed in low-lying levels in {sup 117,119,121}Cd are seen to weaken with increasing spins, with a quasi-rotational degree of freedom manifested at higher spins. The{sup 5-}levels in even-N{sup 118,120}Cd were tentatively interpreted as candidates of quadrupole-octupole (QOC) coupling. The model-independent spin versus {h_bar}{omega} curves for even-N and odd-N Cd isotopes imply quasirotational alignment of an h11/2 neutron pair in the even-N Cd isotopes. The relative energies of the lowest 11/{sup 2-}, 9/{sup 2-}, 7/{sup 2-}, and 15/{sup 2-} levels in {sup 117}Cd and {sup 119}Cd suggest triaxial shapes based on Meyer-Ter-Vehn theory for these odd-N Cd nuclei. For the even-N Cd isotopes evidence of triaxiality may also be provided by the Shell Correction version of the Tilted Axis Cranking model (SCTAC).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of spectral summing to indeterminate suspect low-level drums at Los Alamos National Laboratory

An analytical technique developed by Pajarito Scientific Corporation (PSC), utilizing spectral summing of spectra from groups of drums of similar waste type, is being employed by the Waste Disposition Project - Low Level Waste Disposal (WDP-LLWD) Group at Los Alamos National Laboratory (LANL). This technique has been used to disposition low-level radioactive waste that has dropped out of the transuranic (TRU) category and has no place to go unless it can be proven to be LLW and not TRU. The TRU program at LANL run by Mobile Characterization Services (MCS) employs two High Efficiency Neutron Counters (HENC) with built-in gamma assay systems to assay radioactive waste for shipment and disposal as TRU waste at the Waste Isolation Pilot Plant (WIPP) at Carlsbad, New Mexico. As well as being certified for WIPP assays, the HENC systems can also be used for low-level waste assays for disposal at LANL or off-site disposal facilities, such as the Nevada Test Site (NTS). Some of the waste processed through the HENC systems cannot be confinned TRU due to the absence of detected TRU alpha emitters above the TRU cutoff of 100 nCi/g. This waste becomes suspect low-level waste (SLLW). In many cases, the waste also can't be classified as LLW because the minimum detectable activity (MDA) of TRU radio nuclides is above the 100 nCi/g level. These wastes that do not have enough detectable TRU activity to be classified as TRU waste and have too high a MDA to be classified as LLW enter a radioactive waste characterization indetenninate status that prevents their dispositioning as either TRU waste or LLW. Spectral summing allows an experienced ganuna spectroscopy analyst to add the HENC gamma spectra of a number of similar waste items together to form a consolidated (summed) spectrum. This summed spectrum contains the assay results of the group of items rather than the individual item, and gamma peaks that were not discernable in the individual spectra can become quantifiable in the summed spectrum and the MDA for group sum is reduced. The group of waste items can then be properly classified as LLW based on the summed spectrum and valid assay values can be assigned for disposal. This technique has been successfully applied to a set of 52 debris drums - with individual MDA > 100 nCi/g - with a resulting group total TRU alpha activity concentration below 40nCi/g. Further application of the technique at LANL to other waste drums that are measured on a WIPP certified HENC system is planned and good candidate drum sets are being evaluated as indeterminate situations develop.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of spectral summing to indeterminate suspect low-level drums at Los Alamos National Laboratory

The spectral summing technique developed by Pajarito Scientific Corporation (PSC) is a unique modeling technique that is being employed by the Waste Disposition Project - Low Level Waste Disposition (WDP-LLWD) Group at Los Alamos National Laboratory (LANL). This technique has been used to disposition low-level radioactive waste that has dropped out of the transuranic (TRU) category and has no disposal path unless it can be proven to be LLW and not TRU. The TRU program at LANL run by Mobile Characterization Services (MCS) employs High Efficiency Neutron Counters (HENC) with built-in gamma assay systems to assay radioactive waste for shipment and disposal as TRU waste at the Waste Isolation Pilot Plant (WIPP) at Carlsbad, New Mexico. As well as being certified for WIPP assays, the HENC systems can also be used for low-level waste assays for disposal at LANL or off-site disposal facilities, such as the Nevada Test Site (NTS). Some of the waste processed through the HENC systems cannot be confirmed TRU due to the absence of detected TRU alpha emitters above the TRU cutoff of 100 nCi/g. This waste becomes suspect low-level waste (SLLW). In many cases, the waste also can't be classified as LLW because the minimum detectable activity (MDA) of TRU radionuclides is above the 100 nCi/g level. These wastes that do not have enough detectable TRU activity to be classified as TRU waste and have TRU MDAs > 100nCi/g enter a radioactive waste characterization indeterminate state that prevents their dispositioning as either TRU waste or LLW. Spectral summing allows an experienced gamma spectroscopy analyst to add the HENC gamma spectra of a number of similar waste items together to form a consolidated (summed) spectrum. This summed spectrum contains the assay results of the group of items rather than the individual item, and gamma peaks that were not discemable in the individual spectra become quantifiable in the summed spectrum and the MDA for the group sum is reduced. The group of waste items can then be properly classified as LLW waste on the summed spectrum and valid assay values can be assigned for disposal. This technique has been successfully applied to a set of 52 debris drums - with individual MDA > 100nCi/g - with a resulting group total TRU alpha activity concentration below 40nCi/g. Further application of the technique at LANL to other debris drums and sludge drums that were measured on a WIPP certified HENe is planned and good candidate drum sets are being evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cementitious Grout for Closing SRS High Level Waste Tanks - 12315

In 1997, the first two United States Department of Energy (US DOE) high level waste tanks (Tanks 17-F and 20-F: Type IV, single shell tanks) were taken out of service (permanently closed) at the Savannah River Site (SRS). In 2012, the DOE plans to remove from service two additional Savannah River Site (SRS) Type IV high-level waste tanks, Tanks 18-F and 19-F. These tanks were constructed in the late 1950's and received low-heat waste and do not contain cooling coils. Operational closure of Tanks 18-F and 19-F is intended to be consistent with the applicable requirements of the Resource Conservation and Recovery Act (RCRA) and the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and will be performed in accordance with South Carolina Department of Health and Environmental Control (SCDHEC). The closure will physically stabilize two 4.92E+04 cubic meter (1.3 E+06 gallon) carbon steel tanks and isolate and stabilize any residual contaminants left in the tanks. Ancillary equipment abandoned in the tanks will also be filled to the extent practical. A Performance Assessment (PA) has been developed to assess the long-term fate and transport of residual contamination in the environment resulting from the operational closure of the F-Area Tank Farm (FTF) waste tanks. Next generation flowable, zero-bleed cementitious grouts were designed, tested, and specified for closing Tanks 18-F and 19-F and for filling the abandoned equipment. Fill requirements were developed for both the tank and equipment grouts. All grout formulations were required to be alkaline with a pH of 12.4 and to be chemically reducing with a reduction potential (Eh) of -200 to -400. Grouts with this chemistry stabilize potential contaminants of concern. This was achieved by including Portland cement and Grade 100 slag in the mixes, respectively. Ingredients and proportions of cementitious reagents were selected and adjusted to support the mass placement strategy developed by Savannah River Remediation (SRR) Closure Operations. Subsequent down selection was based on compressive strength and saturated hydraulic conductivity results. Fresh slurry property results were used as the first level of screening. A high range water reducing admixture and a viscosity modifying admixture were used to adjust slurry properties to achieve flowable grouts. Adiabatic calorimeter results were used as the second level screening. The third level of screening was used to design mixes that were consistent with the fill material parameters used in the F-Tank Farm Performance Assessment which was developed to assess the long-term fate and transport of residual contamination in the environment resulting from the operational closures. The cement and slag contents of a mix selected for filling Tanks 18-F and 19-F should be limited to no more than 125 and 210 lbs/cyd, respectively, to limit the heat generated as the result of hydration reaction during curing and thereby enable mass pour placement. Trial mixes with water to total cementitious materials ratios of 0.550 to 0.580 and 125 lbs/cyd of cement and 210 lbs/cyd of slag met the strength and permeability requirements. Mix LP no.8-16 was selected for closing SRS Tanks 18-F and 19-F because it meets or exceeds the design requirements with the least amount of Portland cement and blast furnace slag. This grout is expected to flow at least 45 feet. A single point of discharge should be sufficient for unrestricted flow conditions. However, additional entry points should be identified as back-up in case restrictions in the tank impede flow. The LP no.8 series of trial mixes had surprisingly high design compressive strengths (2000 to 4000/5000 psi) which were achieved at extended curing times (28 to 90 days, respectively) given the small amount of Portland cement in the mixes (100 to 185 lbs/cyd). The grouts were flowable structural fills containing 3/8 inch gravel and concrete sand aggregate. These grouts did not segregate and require no compaction. They have low permeabilities (≤ 10{sup -9} cm/s) and are consequently expected to be very durable. This series of trial mixes contained by-product materials, i.e., slag and Class F fly ash, and an admixture system initially specified for the grouts used to close Tanks 17-F and 20-F at SRS. The mix designs have low CO{sub 2} footprints because Portland cement contents are very low and can be considered environmentally friendly. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Managing Low-Level Waste at Dounreay - 16269

Dounreay Site Restoration Limited (DSRL) is the site licence company responsible for the clean-up and demolition of Britain's former centre of fast reactor research and development. The Dounreay site requires facilities to dispose of up to 175,000 cubic metres of low level waste (LLW) that has been and will continue to be generated during the decommissioning and restoration of the site. In May 2014, construction of two new vaults for the disposal of LLW at Dounreay was completed, including the necessary roads, infrastructures and services, followed by an encapsulation plant in September 2014. The vaults are located immediately to the northeast of the Dounreay licensed site, on NDA-owned land. The facilities are for disposal of the solid LLW generated at Dounreay and the adjacent Vulcan site only. In 2004, following consultation with stakeholders and members of the public, Dounreay issued the 'Best Practicable Environmental Option (BPEO) Report' on the management of Dounreay LLW. This report assessed potential management options for LLW against a range of criteria, including technical, environmental, cost, health and safety issues. The study was conducted in line with best practice and involved consultation with a range of people, including the local community and organisations with an interest in radioactive waste management. The recommendations and conclusions from the study provided the basis for the 'Dounreay Solid LLW Overall Strategy', which was published in March 2005. A fundamental component of this strategy was the development of new below-ground disposal vaults for LLW at Dounreay. Siting the vaults on land at Dounreay avoids any need to transport the LLW away from Dounreay on public roads. Disposal at Dounreay therefore satisfies the proximity principle of managing the waste at source. Disposal at Dounreay is also consistent with UK Government Policy on LLW management, the Scottish Government's Radioactive Waste Management Policy and the Nuclear Decommissioning Authority's (NDA's) strategy on management of LLW from the UK nuclear industry. A planning application was initially lodged with the Highland Council in June 2006. The period for the determination of this application was extended to allow the Scottish Environment Protection Agency (SEPA) sufficient time to assess fully the supporting Environmental Safety Case (ESC). The planning application was re-activated in May 2008, and planning permission was granted by Highland Council in April 2009. The planning permission included 26 conditions on DSRL, covering a wide range of environmental issues such as construction noise/dust, traffic, visual impact and also a condition to develop a community fund aimed at socio-economic development of the area around the Dounreay site. After undertaking the necessary detailed design work, construction of the phase one vaults commenced in November 2011 by principal contractor, Graham Construction. Work was undertaken on both vaults simultaneously, excavating around 243,000 m{sup 3} of rock. When excavation was complete, steel reinforcement was placed and concrete poured to construct the floor slabs. This was followed by the construction of the reinforced walls and then the installation of the steel support structure and materials that form the roof. Mechanical and electrical installation then followed, in parallel with the construction of the vault apron, ramps and access roads. A pumping system and control building was also constructed to remove groundwater from around the vaults to allow the vaults to be kept dry while they are being filled with waste. A layer of excavated material, approximately 3 m thick, was placed across the existing ground surface between the vaults and the coast, to ensure the water table lies well below the new ground surface after closure of the vaults, and that any future trace contaminated groundwater flows out to the sea rather than to the soil zone. This layer is referred to in project documents as the 'enhanced geosphere'. After disposals are completed and the vaults are closed, this layer will be joined to the capping over the vaults so that the ensemble merges visually with the surrounding landscape. The original vegetation and soil mix will be returned as far as is practicable. An encapsulation plant has been constructed to fill the LLW containers with grout prior to disposal in the vault, similar to the process used at the national Low-Level Waste Repository facility (LLWR), near Drigg in Cumbria. The plant has the capacity to grout up to four containers per day. The grout fills voids in the container and helps provide chemical conditions in the vault that limit the release of radionuclides in the far future, after the vault has been penetrated by groundwater. On April 24 2015, active commissioning began at the Encapsulation Plant and LLW Vaults. Half-height ISO containers packed with low level waste are currently being filled with grout and disposed of in the LLW Vault. Also packaged Demolition Low Level Waste (DLLW) is being processed and disposed of in the Demolition Low Level Waste Vault. To date over 2500 packages of DLLW and 70 containers LLW have been disposed of. Completion of construction and the start of operating the Phase One vaults and encapsulation plant are fundamental to the successful and efficient decommissioning of the Dounreay site, upon which many millions of pounds of investment and hundreds of jobs rely.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulating county-level crop yields in the Conterminous United States using the Community Land Model: The effects of optimizing irrigation and fertilization

Representing agricultural systems explicitly in Earth system models is important for understanding the water-energy-food nexus under climate change. In this study, we applied Version 4.5 of the Community Land Model (CLM) at a 0.125 degree resolution to provide the first county-scale validation of the model in simulating crop yields over the Conterminous United States (CONUS). We focused on corn and soybean that are both important grain crops and biofuel feedstocks (corn for bioethanol; soybean for biodiesel). We find that the default model substantially under- or over-estimate yields of corn and soybean as compared to the US Department of Agriculture (USDA) census data, with corresponding county-level root-mean square error (RMSE) of 45.3 Bu/acre and 12.9 Bu/acre, or 42% and 38% of the US mean yields for these crops, respectively. Based on the numerical experiments, the lack of proper representation of agricultural management practices, such as irrigation and fertilization, was identified as a major cause for the model's poor performance. After implementing an irrigation management scheme calibrated against county-level US Geological Survey (USGS) census data, the county-level RMSE for corn yields reduced to 42.6 Bu/acre. We then incorporated an optimized fertilizer scheme in rate and timing, which is achieved by the constraining annual total fertilizer amount against the USDA data, considering the dynamics between fertilizer demand and supply and adopting a calibrated fertilizer scheduling map. The proposed approach is shown to be effective in increasing the fertilizer use efficiency for corn yields, with county-level RMSE reduced to 23.8 Bu/acre (or 22% of the US mean yield). In regions with similar annual fertilizer applied as in the default, the improvements in corn yield simulations are mainly attributed to application of longer fertilization periods and consideration of the dynamics between fertilizer demand and supply. For soybean which is capable of fixing nitrogen to meet nitrogen demand, the reduced positive bias to 6.9 Bu/acre (or 21% of the country mean) was mainly attributed to consideration of the dynamic interactions between fertilizer demand and supply. Although large bias remains in terms of the spatial pattern (i.e. high county-level RMSE), mainly due to limited performance over the Western US, our results show that optimizing irrigation and fertilization can lead to promising improvement in crop and soybean yield simulations in terms of the mean and variability especially over the Mid-west corn belt, and subsequent evapotranspiration (ET) estimates. Finally, this study demonstrates the CLM4.5 capability for predicting crop yields and their interactions with climate, and highlights the value of continued model improvements and development to understand biogeophysical and biogeochemical impacts of land use and land cover change using an Earth system modeling framework.

54 ENVIRONMENTAL SCIENCES↗

Natural and anthropogenic controls on lake water‐level decline and evaporation‐to‐inflow ratio in the conterminous United States

Abstract Lake water levels are integral to lake function, but hydrologic changes from land and water management may alter lake fluctuations beyond natural ranges. We constructed a conceptual model of multifaceted drivers of lake water levels and evaporation‐to‐inflow ratio (Evap : Inflow). Using a structural equation modeling framework, we tested our model on (1) a national subset of lakes in the conterminous United States with minimal water management to describe natural drivers of lake hydrology and (2) five ecoregional subsets of lakes to explore regional variation in water management effects. Our model fits the national and ecoregional datasets and explained up to 47% of variation in Evap : Inflow, 38% of vertical water level decline, and 79% of horizontal water level decline (littoral exposure). For lakes with minimal water management, Evap : Inflow was related to lake depth ( β = −0.31) and surface inflow ( β = −0.44); vertical decline was related to annual climate (e.g., precipitation β = −0.18) and water management ( β = −0.21); and horizontal decline was largely related to vertical decline ( β = 0.73) and lake morphometry (e.g., depth β = −0.18). Anthropogenic effects varied by ecoregion and likely reflect differences in regional water management and climate. In the West, water management indicators were related to greater vertical decline ( β = 0.38), whereas in the Midwest, these indicators were related to more stable and full lake levels ( β = −0.22) even during drought conditions. National analyses show how human water use interacts with regional climate resulting in contrasting impacts to lake hydrologic variation in the United States.

Fergus, C. Emi↗

Deep-Level Defects and Impurities in InGaN Alloys

In this study, density functional theory calculations with a hybrid functional are used to examine the charge-state transition levels of native point defects and impurities in InGaN alloys, with the goal of identifying centers that play a role in defect-assisted recombination. Explicit alloy calculations are used to monitor the dependence of defect levels on indium content and distribution of In atoms. The relative shift (or lack thereof) of the charge-state transition levels of the different defects is explained by the atomic character of the defect state and whether it is derived from valence-band or conduction-band states of the host material or acts as an atomic-like impurity. The various possible atomic configurations of In and Ga cations for a given composition of InGaN lead to a distribution of charge-state transition levels. Defects on the nitrogen site lead to a larger spread in levels compared with defects on the cation site.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A two-loop four-point form factor at function level

Recently, the maximally-helicity-violating four-point form factor for the chiral stress-energy tensor in planar $\mathcal{N}$ = 4 super Yang-Mills was computed to three loops at the level of the symbol associated with multiple polylogarithms. It exhibits antipodal self-duality, or invariance under the combined action of a kinematic map and reversing the ordering of letters in the symbol. Here we lift the two-loop form factor from symbol level to function level. We provide an iterated representation of the function’s derivatives (coproducts). In order to do so, we find a three-parameter limit of the five-parameter phase space where the symbol’s letters are all rational. We also use function-level information about dihedral symmetries and the soft, collinear, and factorization limits, as well as limits governed by the form-factor operator product expansion (FFOPE). We provide plots of the remainder function on several kinematic slices, and show that the result is compatible with the FFOPE data. We further verify that antipodal self-duality is valid at two loops beyond the level of the symbol.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT

Purpose: Multidetector computed tomography (MDCT) is used in the diagnosis of pancreatic ductal adenocarcinoma (PDAC), but it may be inadequate in some cases. Tumor detection can be improved using rapid kV-switching dual-energy CT (rsDECT) and iodine maps. Our aim this study is to evaluate tumor conspicuity in PDAC cases using rsDECT and iodine maps. Methods: Ninety cases with PDAC were evaluated rsDECT. Tumor contrast (HU) differences, tumor size, CNR (contrast-noise ratio), and noise were measured at 70 keV, individual CNR-energy level, and 45 keV, respectively. Quantitative differences in contrast gain ∆70-CNR and ∆CNR-45 were compared. On iodine maps, the iodine concentration measured in the tumor and parenchyma was normalized to the aorta as normalized iodine concentration (NIC) and compared. Results: The median optimized viewing energy level was 51 keV. The mean ± SD tumor contrast values were 62 ± 20, 115 ± 48, and 152 ± 48 HU (p < 0.001); the largest axial diameters were 36.6 ± 5.1, 37.9 ± 4.2, and 38.3 ± 3.7 mm (p = 0.015); the CNRs were 1.83 ± 0.72, 3.37 ± 0.93, and 2.36 ± 0.56; and the image noise levels were 23.7 ± 6.8, 39.3 ± 11.6, and 59.5 ± 17.2 (p < 0.001) (p < 0.001) for 70 keV, optimized energy level, and 45 keV, respectively. The mean ± SD contrast gain ∆70-CNR was 63 ± 12; and ∆CNR-45 was 31 ± 26 HU (p < 0.001). NIC{sub tumor} and NIC{sub parenchyma} values were 0.62 ± 0.03 and 1.36 ± 0.05 mg/mL, respectively (p = 0.004). Conclusion: The use of low energy levels on rsDECT and iodine maps improves tumor conspicuity. This situation may be help better detection of pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimax Program Terminal Control in Two-Level Hierarchic Nonlinear Discrete Dynamical System

We consider a discrete dynamical system consisting of a number of controllable objects whose dynamics is governed by vector nonlinear discrete recurrent relations with control parameters and perturbations (noises). In such system, two levels of making management decisions are distinguished: the dominating (first) level and the subordinate (second) level, which have different criteria of functioning. These levels are integrated by certain information and control relations. We consider the problem of two-level minimax program terminal control in a discrete dynamical system and propose its mathematical statement and a general scheme of its solution.

97 MATHEMATICS AND COMPUTING↗

Tidal-Fluvial and Estuarine Processes in the Lower Columbia River: I. Along-channel Water Level Variations, Pacific Ocean to Bonneville Dam

This two-part paper provides comprehensive time and frequency domain analyses and models of along-channel water level variations in the 234km-long Lower Columbia River and Estuary (LCRE) and documents the response of floodplain wetlands thereto. In Part I, power spectra, continuous wavelet transforms, and harmonic analyses are used to understand the influences of tides, river flow, upwelling and downwelling, and hydropower operations ("power-peaking") on the water level regime. Estuarine water levels are influenced primarily by astronomical tides and coastal processes, and secondarily by river flow. The importance of coastal and tidal influences decreases in the landward direction, and water levels are increasingly controlled by river flow variations at periods from ≤1 day to years. Water level records are only slightly non-stationary near the ocean, but become increasingly irregular upriver. Although astronomically forced tidal constituents decrease above the estuary, tidal fortnightly and overtide variations increase for 80-200km landward, both relative to major tidal constituents and in absolute terms.

Jay, D. A.↗

Energy levels of one-dimensional systems satisfying the minimal length uncertainty relation

The standard approach to calculating the energy levels for quantum systems satisfying the minimal length uncertainty relation is to solve an eigenvalue problem involving a fourth- or higher-order differential equation in quasiposition space. It is shown that the problem can be reformulated so that the energy levels of these systems can be obtained by solving only a second-order quasiposition eigenvalue equation. Through this formulation the energy levels are calculated for the following potentials: particle in a box, harmonic oscillator, Pöschl–Teller well, Gaussian well, and double-Gaussian well. For the particle in a box, the second-order quasiposition eigenvalue equation is a second-order differential equation with constant coefficients. For the harmonic oscillator, Pöschl–Teller well, Gaussian well, and double-Gaussian well, a method that involves using Wronskians has been used to solve the second-order quasiposition eigenvalue equation. It is observed for all of these quantum systems that the introduction of a nonzero minimal length uncertainty induces a positive shift in the energy levels. It is shown that the calculation of energy levels in systems satisfying the minimal length uncertainty relation is not limited to a small number of problems like particle in a box and the harmonic oscillator but can be extended to a wider class of problems involving potentials such as the Pöschl–Teller and Gaussian wells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗