Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Critical transverse compressive stresses of straight and bent CORC® wires with and without impregnation

CORC® wires are a promising superconductor for accelerator magnet applications. While their excellent uniaxial tensile properties have been well established, potential degradation under transverse compression remains a concern for accelerator magnets, in which transverse compression is a primary stress experienced by superconductors. To evaluate the critical transverse compressive stresses of rare-earth barium copper oxide conductors, we developed an experimental system that enables testing of samples both with and without impregnation in liquid nitrogen. Furthermore, because bending strain induced during coil winding may influence the critical compressive response of CORC® wires, the apparatus was also modified to allow testing under the bending condition. In this study wires were tested for five configurations: (1) straight, non-impregnated, (2) bent, non-impregnated, (3) straight, Stycast 2850 FT-impregnated, (4) bent, Stycast 2850 FT-impregnated, and (5) bent, paraffin wax-impregnated. The transverse pressures corresponding to 3% and 5% reductions in the critical current are reported. In conclusion, the effects of wire bending and impregnation on the critical transverse pressure are analyzed, and the implications for transverse stress levels in accelerator magnet conductors are discussed.

CORC® wire↗

A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers

A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and offers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kind, with an active volume of \three has been constructed and operated at CERN. In this paper we describe in detail the experimental setup and detector components as well as report on the operation experience. We also present the first results on the achieved charge amplification, prompt scintillation and electroluminescence detection, and purity of the liquid argon from analyses of a collected sample of cosmic ray muons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-plane electric fields and the 𝜈 = $\frac{5}{2}$ fractional quantum Hall effect in a disk geometry

The 𝜈 = $\frac{5}{2}$ fractional quantum Hall effect is of experimental and theoretical interest due to the possible non-Abelian statistics of the excitations in the electron liquid. A small voltage difference across a sample applied in experiments to probe the system is often ignored in theoretical studies due to the Galilean invariance in the thermodynamic limit. No experimental sample, however, is Galilean invariant. In this Rapid Communication, we explore the effects of the probe electric fields in a disk geometry with finite thickness. We find that weak probe fields enhance the Moore-Read Pfaffian state, but sufficiently strong electric fields destroy the incompressible state. In a disk geometry, the behavior of the system depends on the polarity of the applied radial field, which can potentially be observed in experiments using a Corbino disk configuration. Finally, our simulation also shows that the application of such a field enhances the coherence length of quasiholes propagating through the edge channels.

exact diagonalization↗

Profile of Secreted Hydrolases, Associated Proteins, and SlpA in Thermoanaerobacterium saccharolyticum during the Degradation of Hemicellulose

Thermoanaerobacterium saccharolyticum, a Gram-positive thermophilic anaerobic bacterium, grows robustly on insoluble hemicellulose, which requires a specialized suite of secreted and transmembrane proteins. We report here the characterization of proteins secreted by this organism. Cultures were grown on hemicellulose, glucose, xylose, starch, and xylan in pH-controlled bioreactors, and samples were analyzed via spotted microarrays and liquid chromatography-mass spectrometry. Key hydrolases and transporters employed by T. saccharolyticum for growth on hemicellulose were, for the most part, hitherto uncharacterized and existed in two clusters (Tsac_1445 through Tsac_1464 for xylan/xylose and Tsac_1344 through Tsac_1349 for starch). A phosphotransferase system subunit, Tsac_0032, also appeared to be exclusive to growth on glucose. Previously identified hydrolases that showed strong conditional expression changes included XynA (Tsac_1459), XynC (Tsac_0897), and a pullulanase, Apu (Tsac_1342). An omnipresent transcript and protein making up a large percentage of the overall secretome, Tsac_0361, was tentatively identified as the primary S-layer component in T. saccharolyticum, and deletion of the Tsac_0361 gene resulted in gross morphological changes to the cells. The view of hemicellulose degradation revealed here will be enabling for metabolic engineering efforts in biofuel-producing organisms that degrade cellulose well but lack the ability to catabolize C5 sugars

Currie, Devin↗

An effective QWBA/UHPLC-MS/tissue punch approach: solving a pharmacokinetic issue via quantitative Met-ID

Methods to provide absolute quantitation of the administered drug and corresponding metabolites in tissue in a spatially resolved manner is a challenging but much needed necessity in pharmaceutical research. Quantitative whole-body autoradiography (QWBA) after a single-dose intravenous (3 mg/kg) and extravascular (30 mg/kg) administrations of an in vitro metabolically stable test compound (structure not reported here) indicated quick tissue distribution and excretion. Good bioavailability and short in vivo half-lives were determined formerly for the same test compound. For closing gaps in the understanding of pharmacokinetic data and in vitro results, radioactive hot spots on whole-body tissue sections had been profiled. Punches from selected tissue regions containing high radioactivity in the tissue sections previously analyzed by QWBA were extracted by a highly organic solvent and analyzed without any consecutive sample preparation step, applying ultra high performance liquid chromatography-mass spectrometry (UHPLC-MS) and off-line radioanalysis to maximize signal levels for metabolite identification and profiling. The analysis revealed that the test compound was metabolized intensively by phase I reactions in vivo and the metabolites formed were excreted in bile and in urine. The predominant metabolites showed abundant signal intensities both by MS and by radioanalysis but the MS signal intensities generally underestimated the real abundances of metabolites relative to the unchanged drug. In this work we illustrate that maximizing the sensitivity of tissue punch radioanalysis and the combination with UHPLC-MS leads to a better insight of pharmacokinetic processes by providing quantitative data with high molecular selectivity.

60 APPLIED LIFE SCIENCES↗

Quantitative chemical assay of nanogram-level particulate matter using aerosol mass spectrometry: characterization of particles collected from uncrewed atmospheric measurement platforms

Abstract. Aerosol generation techniques have expanded the utility of aerosol mass spectrometry (AMS) for offline chemical analysis of airborne particles and droplets. However, standard aerosolization techniques require relatively large liquid volumes (e.g., several milliliters) and high sample masses that limit their utility. Here we report the development and characterization of a micronebulization AMS (MN-AMS) technique that requires as low as 10 µL of sample and can provide the quantification of the nanogram level of organic and inorganic substances via the usage of an isotopically labeled internal standard (34SO42-). Using standard solutions, the detection limits for this technique were determined at 0.19, 0.75, and 2.2 ng for sulfate, nitrate, and organics, respectively. The analytical recoveries for these species are 104 %, 87 %, and 94 %, respectively. This MN-AMS technique was applied successfully to analyze filter and impactor samples collected using miniature particulate matter (PM) samplers deployable on uncrewed atmospheric measurement platforms, such as uncrewed aerial systems (UASs) and tethered balloon systems (TBSs). Chemical composition of PM samples collected from a UAS field campaign conducted at the Department of Energy's (DOE) Southern Great Plains (SGP) observatory was characterized. The offline MN-AMS data compared well with the in situ PM composition measured by a co-located aerosol chemical speciation monitor (ACSM). In addition, the MN-AMS and ion chromatography (IC) agreed well for measurements of sulfate and nitrate concentrations in the PM extracts. This study demonstrates the utility of combining MN-AMS with uncrewed measurement platforms to provide quantitative measurements of ambient PM composition.

54 ENVIRONMENTAL SCIENCES↗

Instrumentation for Structure Measurements on Highly Non-equilibrium Materials

Containerless techniques (levitation) completely eliminate contact with the sample. This unique sample environment allows deep supercooling of many liquids and avoids contamination of high temperature melts. Recent experiments at the APS high energy beamline 11 ID-C used aerodynamic levitation with laser beam heating and acoustic levitation with cryogenic cooling. By using these two methods, liquids were studied over much of the temperature range from -40 to +2500 C. This paper briefly describes the instrumentation and its use with an -Si area detector that allows fast, in-situ measurements. Use of the instruments is illustrated with examples of measurements on molten oxides and aqueous materials.

Weber, Richard↗

EMAT enhanced dispersion of particles in liquid

Particulate matter is dispersed in a fluid material. A sample including a first material in a fluid state and second material comprising particulate matter are placed into a chamber. The second material is spatially dispersed in the first material utilizing EMAT force. The dispersion process continues until spatial distribution of the second material enables the sample to meet a specified criterion. The chamber and/or the sample is electrically conductive. The EMAT force is generated by placing the chamber coaxially within an induction coil driven by an applied alternating current and placing the chamber and induction coil coaxially within a high field magnetic. The EMAT force is coupled to the sample without physical contact to the sample or to the chamber, by another physical object. Batch and continuous processing are utilized. The chamber may be folded within the bore of the magnet. Acoustic force frequency and/or temperature may be controlled.

36 MATERIALS SCIENCE↗

Electrochemical detection of gas phase chemicals

We provide an electrochemical sensor in which working microelectrodes are arranged in an array and interconnected in parallel. The working electrodes are arranged so that in use, they are electrochemically coupled to a counter electrode structure through an electrolyte. The sensor also includes a microporous body arranged so that in use, it is situated at a boundary between a gaseous environment and the electrolyte. In another aspect, we provide a method of sensing in which a sample of gas is admitted to a liquid electrolyte maintained by pores of a porous substrate. A voltage is applied to the liquid electrolyte, and an electrical response to the applied voltage is observed, thereby to detect electrochemical evidence of an analyte within the liquid electrolyte.

Klavetter, Kyle C.↗

High frequency acoustic microscopy for the determination of porosity and Young's modulus in high burnup uranium dioxide nuclear fuel

During irradiation UO{sub 2} nuclear fuel experiences the development of a non-uniform distribution of porosity which contributes to establish varying mechanical properties along the radius of the pellet. Radial variations of the porosity and of elastic properties in high burnup UO{sub 2} pellet can be investigated via high frequency acoustic microscopy. Ultrasound waves are generated by a piezoelectric transducer and focused on the sample, after having travelled through a coupling liquid. The elastic properties of the material are related to the velocity of the generated Rayleigh surface wave (VR). A 67 MWd/kgU UO{sub 2} pellet was characterized using the acoustic microscope installed in the hot cells of the Institute of Transuranium Elements: 90 MHz frequency was applied, methanol was used as coupling liquid and VR was measured at different radial positions. By comparing the porosity values obtained via acoustic microscopy with those determined using ceramographic image analysis a good agreement was found, especially in the areas close to the centre. In addition Young's modulus was calculated and its radial profile was correlated to the corresponding burnup profile. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Biobriefcase aerosol collector heater

A system for sampling air and collecting particles potentially including bioagents entrained in the air for detection. The system comprises collecting a sample of the air with the particles entrained in the air, directing the sample to a receiving surface, directing a liquid to the receiving surface thereby producing a liquid surface, wherein the particles potentially including bioagents become captured in the liquid, and heating the liquid wherein the particles potentially including bioagents become heated to lysis the bioagents.

47 OTHER INSTRUMENTATION↗

Automated Systems for Solvent Extraction

An automated solvent extraction system for the eventual handling of radioactive materials has been designed and procured for rapid, efficient and safe liquid-liquid extraction processes. This system will be configured to carry out liquid-liquid separations from beginning to end, automating tedious and time-consuming tasks such as organic/aqueous phase prep, pH checks, phase separation, and metal ion analysis. The system features advanced liquid handling capabilities, a robotic arm for precise sample transfer, and sophisticated analytical tools including UV-VIS spectrophotometry for real-time monitoring. Additionally, it incorporates automated capping of vials, vortex mixing, and centrifugation to ensure thorough mixing and phase separation. This report provides an overview of the system and general capabilities as well as initial efforts to develop an automated workflow for liquid-liquid separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Observations and Lessons Learned from Testing of the Hanford Waste Treatment Plant Standard High Solids Vessel Design - 18635

The Hanford Waste Treatment and Immobilization Plant (WTP) recently completed qualification testing of the mixing system for the standard high solids vessel design the U.S. Department of Energy (DOE) proposed to replace several vessels in the design of the plant Pretreatment Facility. Testing was split into two phases. The first phase exercised the pulse jet mixer control system to ensure that the control software could accommodate fluids across the complete range of expected densities and viscosities within the vessel for all operational modes. The second phase of testing was focused on the mixing performance of the vessel, specifically, whether mixing was adequate to support the transfer, de-inventory, throughput, and sampling functions of the vessel. Key observations and lessons learned from testing include: - Successful transfer of waste within and beyond the design basis slurry solids concentration; - Successful resuspension and transfer of large, heavy particles; - Effective performance of multi-level bubblers for process control and monitoring; - Effective controls performance; - Reduction of sparger flowrate from nominal design flow; - Liquid blending within about 15 minutes; - Insights into sample representativeness and uniformity of transfers to inform process control strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proteomic and targeted qPCR analyses of subsurface microbial communities for presence of methane monooxygenase

The Test Area North (TAN) site at the Idaho National Laboratory near Idaho Falls, ID, USA, sits over a trichloroethylene (TCE) contaminant plume in the Snake River Plain fractured basalt aquifer. Past observations have provided evidence that TCE at TAN is being transformed by biological natural attenuation that may be primarily due to co-metabolism in aerobic portions of the plume by methanotrophs. TCE co-metabolism by methanotrophs is the result of the broad substrate specificity of microbial methane monooxygenase which permits non-specific oxidation of TCE in addition to the primary substrate, methane. Arrays of experimental approaches have been utilized to understand the biogeochemical processes driving intrinsic TCE co-metabolism at TAN. In this study, aerobic methanotrophs were enumerated by qPCR using primers targeting conserved regions of the genes pmoA and mmoX encoding subunits of the particulate MMO (pMMO) and soluble MMO (sMMO) enzymes, respectively, as well as the gene mxa encoding the downstream enzyme methanol dehydrogenase. Identification of proteins in planktonic and biofilm samples from TAN was determined using reverse phase ultraperformance liquid chromatography (UPLC) coupled with a quadrupole-time-of-flight (QToF) mass spectrometer to separate and sequence peptides from trypsin digests of the protein extracts. Detection of MMO in unenriched water samples from TAN provides direct evidence of intrinsic methane oxidation and TCE co-metabolic potential of the indigenous microbial population. Mass spectrometry is also well suited for distinguishing which form of MMO is expressed in situ either soluble or particulate. Using this method, pMMO proteins were found to be abundant in samples collected from wells within and adjacent to the TCE plume at TAN.

03 NATURAL GAS↗

EFFECT OF TEMPERATURE AND HUMIDITY ON FORMALDEHYDE EMISSIONS IN TEMPORARY HOUSING UNITS

The effect of temperature and humidity on formaldehyde emissions from samples collected from temporary housing units (THUs) was studied. The THUs were supplied by the U.S Federal Emergency Management Administration (FEMA) to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. Based on a previous study 1, 2, four of the composite wood surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. Humidity equilibration experiments were carried out on two of the samples to determine how long the samples take to equilibrate with the surrounding environmental conditions. Small chamber experiments were then conducted to measure emission factors for the four surface materials at various temperature and humidity conditions. The samples were analyzed for formaldehyde via high performance liquid chromatography. The experiments showed that increases in temperature or humidity contributed to an increase in emission factors. A linear regression model was built using natural log of percentage relative humidity (RH) and inverse of temperature (in K) as predictor variables, and natural log of emission factors as the target variable. The coefficients of both inverse temperature and log relative humidity with log emission factor were found to be statistically significant for all the samples at the 95percent confidence level. This study should assist to retrospectively estimate indoor formaldehyde exposures of occupants of temporary housing units (THUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observation of low heat capacities for vapor-deposited glasses of indomethacin as determined by AC nanocalorimetry

Highly stable glass films of indomethacin (IMC) with thicknesses ranging from 75 to 2900 nm were prepared by physical vapor deposition. Alternating current (AC) nanocalorimetry was used to evaluate the heat capacity and kinetic stability of the glasses as a function of thickness. Glasses deposited at a substrate temperature of 0.84T{sub g} displayed heat capacities that were approximately 19 J/(mol K) (4.5%) lower than glasses deposited at T{sub g} (315 K) or the ordinary glass prepared by cooling the liquid. This difference in heat capacity was observed over the entire thickness range and is significantly larger than the {approx}2 J/(mol K) (0.3%) difference previously observed between aged and ordinary glasses. The vapor-deposited glasses were isothermally transformed into the supercooled liquid above T{sub g}. Glasses with low heat capacities exhibited high kinetic stability. The transformation time increased by an order of magnitude as the film thickness increased from 75 to 600 nm and was independent of film thickness for the thickest films. We interpret these results to indicate that the transformation of stable glass into supercooled liquid can occur by either a surface-initiated or bulk mechanism. In these experiments, the structural relaxation time of the IMC supercooled liquid was observed to be nearly independent of sample thickness.

36 MATERIALS SCIENCE↗

Bacterial Immobilization for Imaging by Atomic Force Microscopy

AFM is a high-resolution (nm scale) imaging tool that mechanically probes a surface. It has the ability to image cells and biomolecules, in a liquid environment, without the need to chemically treat the sample. In order to accomplish this goal, the sample must sufficiently adhere to the mounting surface to prevent removal by forces exerted by the scanning AFM cantilever tip. In many instances, successful imaging depends on immobilization of the sample to the mounting surface. Optimally, immobilization should be minimally invasive to the sample such that metabolic processes and functional attributes are not compromised. By coating freshly cleaved mica surfaces with porcine (pig) gelatin, negatively charged bacteria can be immobilized on the surface and imaged in liquid by AFM. Immobilization of bacterial cells on gelatin-coated mica is most likely due to electrostatic interaction between the negatively charged bacteria and the positively charged gelatin. Several factors can interfere with bacterial immobilization, including chemical constituents of the liquid in which the bacteria are suspended, the incubation time of the bacteria on the gelatin coated mica, surface characteristics of the bacterial strain and the medium in which the bacteria are imaged. Overall, the use of gelatin-coated mica is found to be generally applicable for imaging microbial cells.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effects of tacticity and chiral center-to-dipole distance on mesogen-free liquid crystalline self-assembly of sulfonyl-containing comb-like polymers

In this report, new approaches were implemented to achieve novel ferroelectric liquid crystalline self-assembly in mesogen-free comb-like isotactic polyoxypropylenes (iPOPs) bearing mono- or di-sulfonyl groups, which have potential to exhibit high spontaneous polarization for applications in advanced electronic devices. iPOPs with n-alkylsulfonylpentylthioether side chains (iPOP-SC 5 SO 2 C n , where C n is the alkyl tail with n being either 12 or 8) were prepared via a post-polymerization substitution reaction from isotactic poly[(R)-(–)-epichlorohydrin]. Here, the effects of main-chain tacticity, chiral center-to-dipole distance, number of sulfonyl dipoles per side chain, and n-alkyl tail length on the liquid crystalline self-assembly behavior were investigated by comparing iPOPs with their atactic counterparts. First, when the sulfonyl dipole was placed far away from the chiral center in iPOP-SC 5 SO 2 C n compared with our previously reported isotactic polyethers with n-alkylsulfonyl side chains (iPOP-SO 2 C n ), the dipole–dipole interactions among the side chains decreased, which led to more liquid crystalline phases. Smectic E (SmE) and A (SmA) phases were observed after crystal melting; however, the main-chain chiral center was found to have an insignificant effect on the liquid crystalline assembly when compared to the atactic samples. Second, the longer C n tails increased the transition temperatures as a result of stronger van der Waals interactions. Third, after the thioether linkage in the side chain was oxidized into the sulfonyl group, the chiral center–dipole and dipole–dipole interactions in the resultant polymers (i.e., iPOP-SO 2 C 5 SO 2 C n ) enhanced. As a result, the liquid crystalline phase transitions (i.e., crystal → SmE → SmA → I) were pushed to higher temperatures. The knowledge gained in this study will help us further design and achieve the ferroelectric smectic C* phase in mesogen-free comb-like sulfonylated liquid crystalline polymers.

36 MATERIALS SCIENCE↗