Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated Power Systems Management (APSM)

A breadboard power system incorporating autonomous functions of monitoring, fault detection and recovery, command and control was developed, tested and evaluated to demonstrate technology feasibility. Autonomous functions including switching of redundant power processing elements, individual load fault removal, and battery charge/discharge control were implemented by means of a distributed microcomputer system within the power subsystem. Three local microcomputers provide the monitoring, control and command function interfaces between the central power subsystem microcomputer and the power sources, power processing and power distribution elements. The central microcomputer is the interface between the local microcomputers and the spacecraft central computer or ground test equipment.

Bridgeforth, A. O.↗

Edgewise Compression Testing of STIPS-0 (Structurally Integrated Thermal Protection System)

The Structurally Integrated Thermal Protection System (SITPS) task was initiated by the NASA Hypersonics Project under the Fundamental Aeronautics Program to develop a structural load-carrying thermal protection system for use in aerospace applications. The initial NASA concept for SITPS consists of high-temperature composite facesheets (outer and inner mold lines) with a light-weight insulated structural core. An edgewise compression test was performed on the SITPS-0 test article at room temperature using conventional instrumentation and methods in order to obtain panel-level mechanical properties and behavior of the panel. Three compression loadings (10, 20 and 37 kips) were applied to the SITPS-0 panel. The panel behavior was monitored using standard techniques and non-destructive evaluation methods such as photogrammetry and acoustic emission. The elastic modulus of the SITPS-0 panel was determined to be 1.146x106 psi with a proportional limit at 1039 psi. Barrel-shaped bending of the panel and partial delamination of the IML occurred under the final loading.

Brewer, Amy R.↗

Microstructural Effects on SCC Initiation PWR Primary Water Cold-Worked Alloy 600

SCC initiation behavior of one mill annealed alloy 600 plate heat was investigated in simulated PWR primary water under constant load at yield stress with in-situ direct current potential drop (DCPD) monitoring for crack initiation. Twelve specimens were tested at similar cold work levels among which three showed much shorter SCC initiation times (<400 hrs) than the others (>1200 hrs). Post-test examinations revealed that these three specimens all feature an inhomogeneous microstructure where the primary crack always nucleated along the boundary of large elongated grains protruding normally into the gauge. In contrast, such microstructure was either not observed or did not extend deep enough into the gauge in the other specimens exhibiting ~3-6X longer initiation times. In order to better understand the role of this microstructural inhomogeneity in SCC initiation, high-resolution microscopy was performed to compare carbide morphology and strain distribution between the long grains and normal grains, and their potential effects on SCC initiation are discussed in this paper.

Alloy 600↗

AFRL Additive Manufacturing Modeling Series: Challenge 4, In Situ Mechanical Test of an IN625 Sample with Concurrent High-Energy Diffraction Microscopy Characterization

In this work, we describe 3D characterization of an additively manufactured Inconel 625 nickel-base superalloy specimen conducted during a uniaxial tension test using a suite of nondestructive x-ray techniques. High-energy diffraction microscopy in both near- and far-field modalities are employed in situ to track evolution of the material orientation and stress–strain fields at six points during the mechanical test, and these data streams are registered with micro-computed tomography reconstructions which probe the material density. This data volume was matched to a multi-modal serial sectioning characterization of the specimen taken after loading, described in this article’s companion. Twenty-eight grains which were monitored throughout the experiment were selected to form the basis for AFRL AM Modeling Series Challenge 4, Microscale Structure-to-Properties.

36 MATERIALS SCIENCE↗

Deep learning approaches to semantic segmentation of fatigue cracking within cyclically loaded nickel superalloy

Improvements to synchrotron-based micro-computed tomography scanning capabilities have gifted researchers the ability to characterize 4D material thermomechanical responses more thoroughly than ever before. These advancements, however, have brought about new challenges in analyzing the resulting deluge of data. We report on a nickel-based superalloy specimen imaged 26 times in-situ during cyclic loading at Argonne National Laboratory Advanced Photon Source beamline 1ID, in order to monitor crack growth within the microstructure. Therefore, several deep learning approaches which utilize convolutional neural networks are implemented to segment crack features from reconstructed tomography scans. U-Net architecture implementations are found to be especially effective, achieving IoU = 0.995 +/- 0.004 and Matthews correlation coefficient scores of Φ = 0.826 +/- 0.085. These advancements broaden possibilities for scientists seeking to automate segmentation analyses of similar large datasets.

36 MATERIALS SCIENCE↗

DINGO: Digital assistant to grid operators for resilience management of power distribution system

With increasing adverse weather events and disasters, enabling resiliency of the power distribution system (PDS) is becoming increasingly important. Here in this work, resiliency is defined as the systems ability to keep supplying critical loads even with multiple contingencies. Resiliency may depend on: (a) advanced tools to assist operators in situational awareness and decision making with the increasing volume of data generated by the PDS, (b) visualization and ease of interaction with system resources and information, especially during extreme events and resulting human operator stress, and (c) flexible resources and autonomous control. Operators and support engineers need to interact with the system for key information and take action under stress, given the requirement for decisions in a short time. Integrated technological solutions are prevailing steps to support the most appropriate decision during critical times to serve essential loads. In order to meet the required goals, a Real-time Resiliency Monitoring and Operational Decision Support (RT-RMOD) tool have been developed. It supports various functionalities, including real-time monitoring, resilience assessment, and proactive decision support. However, this work makes advanced feature additions to the tool by developing data-enabled resilience management algorithms for (i) outage detection and localization, (ii) Resiliency-metric driven restoration and reconfiguration, and (iii) NLP based digital assistant for operators called DINGO (DIgital assistaNt to Grid Operators) to interact with Advanced Distribution Management System (ADMS) and RT-RMOD. The developed algorithm was validated for multiple cases of weather events using a real-world, off-grid microgrid system modeled in a real-time simulator, sensor data, and software tools.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator

Presented are voltage measurements taken near the load region on the Z pulsed-power accelerator using an inductive voltage monitor (IVM). Specifically, the IVM was connected to, and thus monitored the voltage at, the bottom level of the accelerator’s vacuum double post-hole convolute. Additional voltage and current measurements were taken at the accelerator’s vacuum-insulator stack (at a radius of 1.6 m) by using standard D-dot and B-dot probes, respectively. During postprocessing, the measurements taken at the stack were translated to the location of the IVM measurements by using a lossless propagation model of the Z accelerator’s magnetically insulated transmission lines (MITLs) and a lumped inductor model of the vacuum post-hole convolute. Across a wide variety of experiments conducted on the Z accelerator, the voltage histories obtained from the IVM and the lossless propagation technique agree well in overall shape and magnitude. However, large-amplitude, high-frequency oscillations are more pronounced in the IVM records. It is unclear whether these larger oscillations represent true voltage oscillations at the convolute or if they are due to noise pickup and/or transit-time effects and other resonant modes in the IVM. Results using a transit-time-correction technique and Fourier analysis support the latter. Regardless of which interpretation is correct, both true voltage oscillations and the excitement of resonant modes could be the result of transient electrical breakdowns in the post-hole convolute, though more information is required to determine definitively if such breakdowns occurred. Despite the larger oscillations in the IVM records, the general agreement found between the lossless propagation results and the results of the IVM shows that large voltages are transmitted efficiently through the MITLs on Z. These results are complementary to previous studies [R. D. McBride et al ., Phys. Rev. ST Accel . Beams 13, 120401 (2010)] that showed efficient transmission of large currents through the MITLs on Z. Altogether, the two studies demonstrate the overall efficient delivery of very large electrical powers through the MITLs on Z.

42 ENGINEERING↗

2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)

Recent proliferation of distributed energy sources in distribution or sub-transmission systems necessitates close monitoring of these three-phase power grids which typically operate under unbalanced loading conditions. Unlike the transmission systems where the network equations are commonly based on the positive sequence component models, a detailed three phase model will have to be used in implementing network applications for these systems. In the specific case of the state estimator, where measurement and parameter errors may bias the solution, bad data and parameter error detection algorithms should also be incorporated. Implementing the state estimator and error detection algorithms for three-phase systems impose additional computational burden and modifications to the state estimation code. This paper proposes a practical solution to avoid these issues by using synchronized phasor measurements and modal decoupling. The previously developed parameter error detection algorithm based on the normalized Lagrange multipliers (NLM) test is applied to the measurements independently in each mode in parallel, not only saving CPU time but also avoiding new code development for a three-phase estimator. Different parameter error scenarios are created and tested to verify the effectiveness of the proposed error detection approach.

Khalili, Ramtin↗

Structure of a Deformed Inhomogeneous Material on the Data of Acoustic Emission and X-Ray Computer Microtomography

Accumulation of defects at various stages of the deformation of a structurally inhomogeneous material (granite) has been studied using two nondestructive methods: acoustic emission (AE) and X-ray computer microtomorgaphy (CT). The quasi-static testing of cylindrical samples of a Westerly granite was carried out under uniaxial compression. The control of the defect formation was realized using the real-time monitoring of acoustic emission. For each sample under study, several steps of the loading and tomographic imaging have been performed. We have found that an exponential or power-law function of the energy distribution of the AE signals makes it possible to select a sample region, in which the system of defects has transited into a self-organized criticality state and large cracks have been formed. This result coincides with the data of the X-ray tomography Computer Microtomography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Building Energy Management Open Source Software

This is the repository for Building Energy Management Open Source Software (BEMOSS), which is an open source operating system that is engineered to improve sensing and control of equipment in small- and medium-sized commercial buildings. BEMOSS offers the following key features: (1) Open source, open architecture – BEMOSS is an open source operating system that is built upon VOLTTRON – a distributed agent platform developed by Pacific Northwest National Laboratory (PNNL). BEMOSS was designed to make it easy for hardware manufacturers to seamlessly interface their devices with BEMOSS. Software developers can also contribute to adding additional BEMOSS functionalities and applications. (2) Plug & play – BEMOSS was designed to automatically discover supported load controllers (including smart thermostats, VAV/RTUs, lighting load controllers and plug load controllers) in commercial buildings. (3) Interoperability – BEMOSS was designed to work with load control devices form different manufacturers that operate on different communication technologies and data exchange protocols. (4) Cost effectiveness – Implementation of BEMOSS deemed to be cost-effective as it was built upon a robust open source platform that can operate on a low-cost single-board computer, such as Odroid. This feature could contribute to its rapid deployment in small- or medium-sized commercial buildings. (5) Scalability and ease of deployment – With its multi-node architecture, BEMOSS provides a distributed architecture where load controllers in a multi-floor and high occupancy building could be monitored and controlled by multiple single-board computers hosting BEMOSS. This makes it possible for a building engineer to deploy BEMOSS in one zone of a building, be comfortable with its operation, and later on expand the deployment to the entire building to make it more energy efficient. (6) Ability to provide local and remote monitoring – BEMOSS provides both local and remote monitoring ability with role-based access control. (7) Security – In addition to built-in security features provided by VOLTTRON, BEMOSS provides enhanced security features, including BEMOSS discovery approval process, encrypted core-to-node communication, thermostat anti-tampering feature and many more. (8) Support from the Advisory Committee – BEMOSS was developed in consultation with an advisory committee from the beginning of the project. BEMOSS advisory committee comprises representatives from 22 organizations from government and industry.

Source record↗

Recent Beam Stability Analysis for the EIC

This document summarizes work done in WBS 6.02.02 during FY23. Additional details can be found in the EIC overview paper presented at IPAC’23 [1], and the references therein. Progress has been made in the ESR and HSR lattice design, dynamic aperture optimization, and the RCS lattice design. The impedance and Collective effects are progressing and include the impedance optimization process of the vacuum systems for RCS, HSR, and ESR; collective effects studies; collective effects and beam-beam interaction; coupled bunch instabilities and the crab cavities; low-level RF feedback system design and beam-ion instability. The reversed phasing RF system has been numerically studied for the ESR to mitigate Robinson instability and demonstrate reliable stable beam operation. Various codes, including C++, SPACE [2], ELEGANT [3], and Mbtrack2 [4] have been employed to benchmark the results. The simulation of HSR bunch splitting with beam loading has been performed at 275 GeV energy. The evaluation of Beam Position Monitors aimed to validate their expected performance, with the primary objective being to verify their accuracy. Calculations of Electron Polarization in the ESR, RCS, and HSR are showing good progress. In the RCS, preliminary studies indicate excellent polarization transmission over intrinsic spin resonances, achieving over 90% transmission with improved performance compared to the previous lattice. Preliminary simulations in the ESR indicate encouraging results in minimizing depolarization and improving equilibrium polarization.

43 PARTICLE ACCELERATORS↗

Variable load automatically tests dc power supplies

Continuously variable load automatically tests dc power supplies over an extended current range. External meters monitor current and voltage, and multipliers at the outputs facilitate plotting the power curve of the unit.

Burke, H. C., Jr.↗

Stress relaxation and mechanical properties of RL-1973 and PD-200-16 silicone resin sponge materials

Stress relaxation tests were conducted by loading specimens in double-lap shear to a preselected strain level and monitoring the decay of stress with time. The stress relaxation response characteristics were measured over a temperature range of 100 to 300 K and four strain levels. It is concluded that only a slight amount of stress relaxation was observed, and the stiffness increased approximately two orders of magnitude over the range of temperatures.

Saylak, D.↗

Specification for a Program for an Interative Aeroelastic Solution (PIAS)

An engineering and software specification which was written for a computer program to calculate aeroelastic structural loads including the effects of nonlinear aerodynamics is presented. The procedure used in the program for an iterative aeroelastic solution (PIAS) is to alternately execute two computer codes: one to calculate aerodynamic loads for a specific wing shape, and another to calculate the deflected shape caused by this loading. A significant advantage to the design of PIAS is that the initial aerodynamic module can be replaced with others. The leading edge vortex (LEV) program is used as the aerodynamic module in PIAS. This provides the capability to calculate aeroelastic loads, including the effects of a separation induced leading edge vortex. The finite element method available in ATLAS Integrated structural analysis and design system is used to determine the deflected wing shape for the applied aerodynamics and inertia loads. The data management capabilities in ATLAS are used by the execution control monitor (ECM) of PIAS to control the solution process.

Manro, M. E.↗

Hygrothermal effects on mechanical behavior of graphite/epoxy laminates beyond initial failure

An investigation was conducted to determine the critical load levels and associated cracking beyond which a multidirectional laminate can be considered as structurally failed. Graphite/epoxy laminates were loaded to different strain levels up to ultimate failure. Transverse matrix cracking was monitored by acoustic and optical methods. Residual stiffness and strength that were parallel and perpendicular to the cracks were determined and related to the environmental/loading history. Results indicate that cracking density in the transverse layers has no major effect on laminate residual properties as long as the angle ply layers retain their structural integrity. Exposure to hot water revealed that cracking had only a small effect on absorption and reduced swelling when these specimens were compared with uncracked specimens. Cracked, moist specimens showed a moderate reduction in strength when compared with their uncracked counterparts. Within the range of environmental/loading conditions of the present study, it is concluded that the transverse cracking process is not crucial in its effect on the structural performance of multidirectional composite laminates.

Ishai, O.↗

Application of a peak-valley detector for secant stiffness measurements

A technique for monitoring the change in secant stiffness of composite specimens during cyclic-fatigue loading computes the secant modulus every five seconds. A resettable peak-valley detector, which captures and holds the maximum and minimum values of an input analog signal, is used in conjunction with a multichannel data acquisition unit. This detector is also used in conjunction with an analog switch to halt the cycling of the specimen after a certain degradation of stiffness develops for the application of NDE techniques. Results for a T300/5208 graphite-epoxy specimen are presented in the form of a stiffness vs number of cycles curve.

Stiffler, R.↗