Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Evolution of a high-performance storage system based on magnetic tape instrumentation recorders

In order to provide transparent access to data in network computing environments, high performance storage systems are getting smarter as well as faster. Magnetic tape instrumentation recorders contain an increasing amount of intelligence in the form of software and firmware that manages the processes of capturing input signals and data, putting them on media and then reproducing or playing them back. Such intelligence makes them better recorders, ideally suited for applications requiring the high-speed capture and playback of large streams of signals or data. In order to make recorders better storage systems, intelligence is also being added to provide appropriate computer and network interfaces along with services that enable them to interoperate with host computers or network client and server entities. Thus, recorders are evolving into high-performance storage systems that become an integral part of a shared information system. Data tape has embarked on a program with the Caltech sponsored Concurrent Supercomputer Consortium to develop a smart mass storage system. Working within the framework of the emerging IEEE Mass Storage System Reference Model, a high-performance storage system that works with the STX File Server to provide storage services for the Intel Touchstone Delta Supercomputer is being built. Our objective is to provide the required high storage capacity and transfer rate to support grand challenge applications, such as global climate modeling.

Peters, Bruce↗

Atomic-scale interface engineering of Majorana edge modes in a 2D magnet-superconductor hybrid system

Topological superconductors are predicted to harbor exotic boundary states—Majorana zero-energy modes—whose non-Abelian braiding statistics present a new paradigm for the realization of topological quantum computing. Using low-temperature scanning tunneling spectroscopy, here, we report on the direct real-space visualization of chiral Majorana edge states in a monolayer topological superconductor, a prototypical magnet-superconductor hybrid system composed of nanoscale Fe islands of monoatomic height on a Re(0001)-O(2 × 1) surface. In particular, we demonstrate that interface engineering by an atomically thin oxide layer is crucial for driving the hybrid system into a topologically nontrivial state as confirmed by theoretical calculations of the topological invariant, the Chern number.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Decoherence induced by magnetic impurities in a quantum hall system

Scattering by magnetic impurities is known to destroy coherence of electron motion in metals and semiconductors. We investigate the decoherence introduced in a single act of electron scattering by a magnetic impurity in a quantum Hall system. For this, we introduce a fictitious nonunitary scattering matrix for electrons that reproduces the exactly calculated scattering probabilities. The strength of decoherence is identified by the deviation of eigenvalues of the product from unity. Using the fictitious scattering matrix, we estimate the width of the metallic region at the quantum Hall effect inter-plateau transition and its dependence on the exchange coupling strength and the degree of polarization of magnetic impurities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

User guide for the digital control system of the NASA/Langley Research Center's 13-inch Magnetic Suspension and Balance System

The technical background to the development of the digital control system of the NASA/Langley Research Center's 13 inch Magnetic Supension and Balance Systen (MSBS) is reviewed. The implementation of traditional MSBS control algorithms in digital form is examined. Extensive details of the 13-inch MSBS digital controller and related hardware are given, together with the introductory instructions for systems operators. Full listings of software are included in the Appendices.

Britcher, Colin P.↗

Knolle Magnetrans: A magnetically levitated train system

The Knolle Magnetrans is a continuous transportation system featuring small cars traveling in rapid succession, levitated by permanent magnets in repulsion, and propelled by stationary linear induction motors. The vehicles' headway, speed, acceleration, and deceleration are designed into the system and mechanically enforced. Passengers board dynamically and controls consist of a simple on-off relay. This paper summarizes the system design goals, describes the system components and discusses related environmental issues.

Knolle, Ernst G.↗

Majorana spin in magnetic atomic chain systems

In this study, we establish that Majorana zero modes emerging from a topological band structure of a chain of magnetic atoms embedded in a superconductor can be distinguished from trivial localized zero energy states that may accidentally form in this system using spin-resolved measurements. To demonstrate this key Majorana diagnostics, we study the spin composition of magnetic impurity induced in-gap Shiba states in a superconductor using a hybrid model. By examining the spin and spectral densities in the context of the Bogoliubov-de Gennes (BdG) particle-hole symmetry, we derive a sum rule that relates the spin densities of localized Shiba states with those in the normal state without superconductivity. Extending our investigations to a ferromagnetic chain of magnetic impurities, we identify key features of the spin properties of the extended Shiba state bands, as well as those associated with a localized Majorana end mode when the effect of spin-orbit interaction is included. We then formulate a phenomenological theory for the measurement of the local spin densities with spin-polarized scanning tunneling microscopy (STM) techniques. By combining the calculated spin densities and the measurement theory, we show that spin-polarized STM measurements can reveal a sharp contrast in spin polarization between an accidental-zero-energy trivial Shiba state and a Majorana zero mode in a topological superconducting phase in atomic chains. We further confirm our results with numerical simulations that address generic parameter settings.

Majorana fermions↗

Further investigation into calibration techniques for a magnetic suspension and balance system

Calibrations performed on three different magnetic cores for wind tunnel models suspended in the Southampton University Magnetic Suspension and Balance System (SUMSBS) are detailed. The first core investigated was the Southampton University pilot Superconducting Solenoid model, first flown in July 1983. Static calibrations of lift force, drag force and pitching moment, together with lift force and pitching moment calibrations determined by the dynamic method are detailed in this report. Other types of core investigated in a similar manner were conventional permanent magnets, Alnico and samarium-cobalt. All static calibrations gave a linear dependence of force on electromagnet current as expected. Dynamic calibrations are faster to perform but are proving to be not as easily analyzed as static calibrations. There are still some effects to be explained but dynamic lift calibration results were obtained agreeing to within 2 percent of the static calibration value.

Eskins, J.↗

Development of ultra-high field superconducting magnetic energy storage (SMES) for use in the ARPA-E project titled “Superconducting Magnet Energy Storage System with Direct Power Electronics Interface”

The purpose of the CRADA is to enable superconducting magnetic energy storage (SMES) for grid-level applications by developing a cost competitive, high energy-storage density, ultra-high field SMES coil using 2G HTS wire in combination with a flexible new modular power electronics interface capable of connection to medium voltage distribution networks.

99 GENERAL AND MISCELLANEOUS↗

A hyperbolic-equation system approach for magnetized electron fluids in quasi-neutral plasmas

A new approach using a hyperbolic-equation system (HES) is proposed to solve for the electron fluids in quasi-neutral plasmas. The HES approach avoids treatments of cross-diffusion terms which cause numerical instabilities in conventional approaches using an elliptic equation (EE). A test calculation reveals that the HES approach can robustly solve problems of strong magnetic confinement by using an upwind method. The computation time of the HES approach is compared with that of the EE approach in terms of the size of the problem and the strength of magnetic confinement. The results indicate that the HES approach can be used to solve problems in a simple structured mesh without increasing computational time compared to the EE approach and that it features fast convergence in conditions of strong magnetic confinement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Drag measurements on a body of revolution in Langley's 13-inch Magnetic Suspension and Balance System

NASA Langley's 13-inch Magnetic Suspension and Balance System (MSBS) has been used to conduct low-speed wind tunnel drag force measurements on a laminar-flow body-of-revolution free of support system interference, in order to verify the drag force measurement capabilities of the MSBS. The drag force calibrations and wind-on repeatability data obtained have verified the design capabilities for this system. A drag-prediction code has been used to assess the MSBS's usefulness in body drag estimation.

Dress, David A.↗

Design and Integration of an All-Magnetic Attitude Control System for FASTSAT-HSV01's Multiple Pointing Objectives

The FASTSAT-HSV01 spacecraft is a microsatellite with magnetic torque rods as it sole attitude control actuator. FASTSAT s multiple payloads and mission functions require the Attitude Control System (ACS) to maintain Local Vertical Local Horizontal (LVLH)-referenced attitudes without spin-stabilization, while the pointing errors for some attitudes be significantly smaller than the previous best-demonstrated for this type of control system. The mission requires the ACS to hold multiple stable, unstable, and non-equilibrium attitudes, as well as eject a 3U CubeSat from an onboard P-POD and recover from the ensuing tumble. This paper describes the Attitude Control System, the reasons for design choices, how the ACS integrates with the rest of the spacecraft, and gives recommendations for potential future applications of the work.

DeKock, Brandon↗

Design and Integration of High Precision Superconducting Magnet Power Supply Systems

This paper reviews the design and integration approach being taken to power more than 400 superconducting magnets in Electron Ion Collider (EIC) by power supplies ranging from 20V to 400V and 100A to 18kA. A major challenge is to integrate existing legacy power supplies with new high current systems and maximize performance and reduce costs. Successful implementation requires coordinated integration of power convertors, current regulation, quench protection, energy extraction, machine protection, controls and existing accelerator infrastructure.

43 PARTICLE ACCELERATORS↗

Integrated semiconductor-magnetic random access memory system

The present disclosure describes a non-volatile magnetic random access memory (RAM) system having a semiconductor control circuit and a magnetic array element. The integrated magnetic RAM system uses CMOS control circuit to read and write data magnetoresistively. The system provides a fast access, non-volatile, radiation hard, high density RAM for high speed computing.

Katti, Romney R.↗

Dynamic Spin Rig Upgraded With a Five- Axis-Controlled Three-Magnetic-Bearing Support System With Forward Excitation

The NASA Glenn Research Center Dynamic Spin Rig is used for experimental evaluation of vibration analysis methods and dynamic characteristics for rotating systems. Measurements are made while rotors are spun and vibrated in a vacuum chamber. The rig has been upgraded with a new active magnetic bearing rotor support and excitation system. This design is expected to provide operational improvements over the existing rig. The rig will be able to be operated in either the old or new configuration. In the old configuration, two ball bearings support the vertical shaft of the rig, with the test article located between the bearings. Because the bearings operate in a vacuum, lubrication is limited to grease. This limits bearing life and speed. In addition, the old configuration employs two voice-coil electromagnetic shakers to apply oscillatory axial forces or transverse moments to the rotor shaft through a thrust bearing. The excitation amplitudes that can be imparted to the test article with this system are not adequate for components that are highly damped. It is expected that the new design will overcome these limitations.

Morrison, Carlos R.↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The E989 Muon g-2 experiment at Fermilab aims to measure the anomalous magnetic moment, a$_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $\omega_a$, and the average magnetic field in terms of the equivalent, free proton Larmor frequency, $\omega_p$. The measurement of $\omega_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration in terms of $\omega_p$. A crucial element for the multi-step measurement of $\omega_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

A review of Magnetic Suspension and Balance Systems

This paper traces the development of Magnetic Suspension and Balance Systems (MSBSs) for use in wind tunnels. The expression MSBS implies a system that can both suspend a model and also measure the forces and moments acting on the model. This avoids the need for any mechanical support of the model. An MSBS uses electromagnets located outside the test section walls to create magnetic fields inside the test section. Measurement of the electrical current flowing in each of the electromagnets can be used to determine the forces and moments acting on the suspended model. An MSBS is capable of supporting a model with an internal magnetized core subject to gravity, aerodynamic, and inertial loads. The model must have a core made of either a permanent magnet, magnetized soft iron, or a solenoid. The position of the suspended body is inherently unstable. A closed-loop control system which includes a position sensing system has to control the position of the body by controlling the applied magnetic fields. This paper includes a discussion of all the known MSBSs and the outlook for larger systems.

Boyden, Richmond P.↗

Disentangling the Entangled Linkages of Magnetic Helicity

Magnetic helicity, H, measures magnetic linkages in a volume. The early theoretical development of helicity focused on magnetically closed systems in V bounded by ∂V. For magnetically closed systems, V ∈ R -3 = V + V∗, no magnetic flux threads the boundary, n̂ · B|∂V = 0. Berger & Field (1984) and Finn & Antonsen (1985) extended the definition of helicity to relative helicity, H, for magnetically open systems where magnetic flux may thread the boundary. Berger (1999, 2003) expressed this relative helicity as two gauge invariant terms that describe the self helicity of magnetic field that closes inside V and the mutual helicity between the magnetic field that threads the boundary ∂V and the magnetic field that closes inside V. The total magnetic field that permeates V entangles magnetic fields that are produced by current sources J in V with magnetic fields that are produced by current sources J∗ in V∗. Building on this fact, we extend Berger’s expressions for relative magnetic helicity to eight gauge invariant quantities that simultaneously characterize both of these self and mutual helicities and attribute their origins to currents J in V and/or J∗ in V∗, thereby disentangling the domain of origin for these entangled linkages. We arrange these eight terms into novel expressions for internal and external helicity (self) and internal-external helicity (mutual) based on their domain of origin. The implications of these linkages for interpreting magnetic energy is discussed and new boundary observables are proposed for tracking the evolution of the field that threads the boundary.

Analytical mathematics↗