At least 793 records · Page 44

Synthesis of Cold Antihydrogen in a Cusp Trap

We report here the first successful synthesis of cold antihydrogen atoms employing a cusp trap, which consists of a superconducting anti-Helmholtz coil and a stack of multiple ring electrodes. This success opens a new path to make a stringent test of the CPT symmetry via high precision microwave spectroscopy of ground-state hyperfine transitions of antihydrogen atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of temperature-dependent electrical conductivity on transport processes in magnetosolidmechanics

The effect of temperature-dependent electrical conductivity on transport processes for a solid block is analyzed on the basis of a one-dimensional steady-state model under specified thermal boundary conditions. Assumptions are that the solid has an infinitely segmented electrode configuration, the magnetic field (By) may be resolved into a constant applied field and an induced field, the gradient of the electrochemical potential is equal to the electrostatic potential, a constant potential difference is applied externally across each pair of opposite electrodes, and all material properties except electrical conductivity are constant. Conductivity is expressed in normalized form in terms of a baseline conductivity and a constant for the material. The application of the assumptions of the model to the general phenomenological relations yields the governing equations. Solution of these equations gives the distribution of temperature, electric current density, and magnetic field strength along the length of the solid. It is shown that significant differences exist between the case for constant electrical conductivity and the case where electrical conductivity is temperature dependent.

Craig, G. T.↗

Magnetic energy storage and conversion in the solar atmosphere

According to the approach employed in this investigation, particularly important simple configurations of magnetic field and plasma are identified, and it is attempted to achieve an understanding of the large-scale dynamic processes and transformations which these systems can undergo. Fundamental concepts are discussed, taking into account aspects of magnetic energy generation, ideal MHD theory, non-MHD properties, the concept of 'anomalous' resistivity, and global electrodynamic coupling. Questions of magnetically controlled energy conversion are examined, giving attention to magnetic modifications of plasma transport, the transition region structure and flows, channeling and acceleration of plasma, channeling and dissipation of MHD waves, and anomalous dissipation of field-aligned currents. A description of the characteristics of magnetohydrodynamic energy conversion is also provided, and outstanding questions are discussed.

Spicer, D. S.↗

Radio structure in the inner 1 arcsecond of NGC 1068

High-resolution VLA and VLBI observations of NGC 1068 at several different wavelengths are reported. These observations provide new information about the triple radio source in the central arcsec (75 pc) of the galaxy. The 21-cm European VLBI Network observations at 0.05-arcsec resolution detect a core of flux density 89 + or - 10 mJy. This core is dominated by a component less than 20 marcsec (1.5 pc) in diameter that has a brightness temperature of about 10 to the 8th K. Two more components may have been detected by the VLBI observations, one on either side of the compact core. At 0.07-arcsec resolution, the 1.3-cm VLA map of the central arcsec of NGC 1068 reveals a C-shaped radio morphology on scales from 10 to 50 pc. A comparison of the relative locations of the three components in the VLA and VLBI maps shows that the compact core in the VLBI map probably should be identified with the central component in the 1.3- and 2-cm VLA maps. If this identification is correct, the central component in the VLA maps is the actual nucleus of the galaxy. The core of the inner triple radio source may contain a significant flat-spectrum component. The presence of a compact core and the evidence for bending strengthen the argument that the inner triple radio source is produced by a mechanism similar to that operating in powerful radio galaxies. For a minimum-energy configuration, magnetic-field strengths of about 1 mG and energy densities of about 100 nerg/cu cm are found for the components of this source.

Ulvestad, James S.↗

Doubly diffusive magnetic buoyancy instability in the solar interior

An investigation of the buoyancy of diffuse magnetic fields has shown that in the presence of rotation, static equilibrium configurations of the toroidal magnetic field and ambient plasma can exist. In that case, the escape of toroidal magnetic flux from the solar interior may be determined by the growth of instabilities which the equilibrium configuration may be subject to. In connection with the present investigation, it is assumed that in the region of toroidal magnetic flux amplification, the magnetic field has not as yet filamented into flux ropes, and is therefore 'diffuse'. A study is conducted of the MHD stability of an electrically conducting and differentially rotating gas in the presence of a toroidal magnetic field, an external constant gravitational field, and radiance pressure. The full dispersion relation for the magnetic buoyancy problem is developed, and the solutions of the dispersion relation are discussed.

Schmitt, J. H. M. M.↗

Recent advances in plasma devices based on plasma lens configuration for manipulating high-current heavy ion beams

We describe new results of development of novel generation cylindrical plasma devices based on the electrostatic plasma lens configuration and concept of electrons magnetic insulation. The crossed electric and magnetic fields plasma lens configuration provides us with the attractive and suitable method for establishing a stable plasma discharge at low pressure. Using plasma lens configuration in this way some cost-effective plasma devices were developed for ion treatment and deposition of exotic coatings and the effective lens was first proposed for manipulating high-current beams of negatively charged particles. Here we describe operation and features of these plasma devices, and results of theoretical consideration of mechanisms determining their optimal operation conditions.

43 PARTICLE ACCELERATORS↗

Note on a noncritical holographic model with a magnetic field

We consider a noncritical holographic model constructed from an intersecting brane configuration D4/D4-D4 with an external magnetic field. We investigate the influences of this magnetic field on strongly coupled dynamics by the gauge/gravity correspondence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new twist to the solar cycle

Recent numerical simulations of magnetic buoyancy instabilities suggest a new mechanism for the variation with the solar cycle in the scale and structure of surface magnetic flux. The nonlinear evolution of a predominantly toroidal field is found to depend crucially on the distribution of the weaker poloidal ingredient. For certain field configurations large, helical magnetic fragments are produced; for others the escaping field is small-scale and untwisted. We propose that the observed structural variations in flux may be accounted for by small changes in the twist of a deep-seated field. The large fragments will appear at the surface as active regions, which dominate at solar maximum, while the small-scale field will emerge as ephemeral regions which constitute practically all of the flux at solar minimum.

Cattaneo, Fausto↗

Aspects of collisionless magnetic reconnection in asymmetric systems

Asymmetric reconnection is being investigated by means of particle-in-cell simulations. The research has two foci: the direction of the reconnection line in configurations with nonvanishing magnetic fields; and the question why reconnection can be faster if a guide field is added to an otherwise unchanged asymmetric configuration. We find that reconnection prefers a direction, which maximizes the available magnetic energy, and show that this direction coincides with the bisection of the angle between the asymptotic magnetic fields. Regarding the difference in reconnection rates between planar and guide field models, we demonstrate that a guide field can provide essential confinement for particles in the reconnection region, which the weaker magnetic field in one of the inflow directions cannot necessarily provide.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aspects of Collisionless Magnetic Reconnection in Asymmetric Systems

Asymmetric reconnection is being investigated by means of particle-in-cell simulations. The research has two foci: The direction of the reconnection line in configurations with nonvanishing magnetic fields; and the question why reconnection can be faster if a guide field is added to an otherwise unchanged asymmetric configuration. We find that reconnection prefers a direction, which maximizes the available magnetic energy, and show that this direction coincides with the bisection of the angle between the asymptotic magnetic fields. Regarding the difference in reconnection rates between planar and guide field models, we demonstrate that a guide field can provide essential confinement for particles in the reconnection region, which the weaker magnetic field in one of the inflow directions cannot necessarily provide.

Hesse, Michael↗

Apparatus for magnetic and electrostatic confinement of plasma

An apparatus and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions ions are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.

47 OTHER INSTRUMENTATION↗

Apparatus for magnetic and electrostatic confinement of plasma

An apparatus and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions ions are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.

42 ENGINEERING↗

Apparatus for magnetic and electrostatic confinement of plasma

An apparatus and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions ions are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lung dosimetry in a linac-MRI radiotherapy unit with a longitudinal magnetic field

Purpose: There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities in this field by proposing and examining by Monte Carlo simulations, a probable longitudinal configuration where the magnetic field is oriented in the same direction as the photon beam. Methods: The EGSnrc Monte Carlo (MC) radiation transport codes with algorithms implemented to account for the magnetic field deflection of charged particles were used to compare dose distributions for linac-MR systems in transverse and longitudinal geometries. Specifically, the responses to a 6 MV pencil photon beam incident on water and lung slabs were investigated for 1.5 and 3.0 T magnetic fields. Further a five field lung plan was simulated in the longitudinal and transverse geometries across a range of magnetic field strengths from 0.2 through 3.0 T. Results: In a longitudinal geometry, the magnetic field is shown to restrict the radial spread of secondary electrons to a small degree in water, but significantly in low density tissues such as lung in contrast to the lateral shift in dose distribution seen in the transverse geometry. These effects extend to the patient case, where the longitudinal configuration demonstrated dose distributions more tightly confined to the primary photon fields, which increased dose to the planning target volume (PTV), bettered dose homogeneity within a heterogeneous (in density) PTV, and reduced the tissue interface effects associated with the transverse geometry. Conclusions: Dosimetry issues observed in a transverse linac-MR geometry such as changes to the depth dose distribution and tissue interface effects were significantly reduced or eliminated in a longitudinal geometry on a representative lung plan. Further, an increase in dose to the PTV, resulting from the magnetic field confining electrons to the forward direction, shows potential for a reduction in dose to the surrounding tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗