At least 793 records · Page 44

Aerial Videography From Locally Launched Rockets

A method of quickly collecting digital imagery of ground areas from video cameras carried aboard locally launched rockets has been developed. The method can be used, for example, to record rare or episodic events or to gather image data to guide decisions regarding treatment of agricultural fields or fighting wildfires. The method involves acquisition and digitization of a video frame at a known time along with information on the position and orientation of the rocket and camera at that time. The position and orientation data are obtained by use of a Global Positioning System receiver and a digital magnetic compass carried aboard the rocket. These data are radioed to a ground station, where they are processed, by a real-time algorithm, into georeferenced position and orientation data. The algorithm also generates a file of transformation parameters that account for the variation of image magnification and distortion associated with the position and orientation of the camera relative to the ground scene depicted in the image. As the altitude, horizontal position, and orientation of the rocket change between image frames, the algorithm calculates the corresponding new georeferenced position and orientation data and the associated transformation parameters. The output imagery can be rendered in any of a variety of formats. The figure presents an example of one such format.

Lyle, Stacey D.↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

SU-E-T-442: Sensitivity of Quality Assurance Tools to Delivery Errors On a Magnetic Resonance-Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the sensitivity of the quality assurance (QA) tools actively used on a clinical MR-IGRT system for potential delivery errors. Methods: Patient-specific QA procedures have been implemented for a commercially available Cobalt-60 MR-IGRT system. The QA tools utilized were a MR-compatible cylindrical diode-array detector (ArcCHECK) with a custom insert which positions an ionization chamber (Exradin A18) in the middle of the device, as well as an in-house treatment delivery verification program. These tools were tested to investigate their sensitivity to delivery errors. For the ArcCHECK and ion chamber, a baseline was established with a static field irradiation to a known dose. Variations of the baseline were investigated which included rotated gantry, altered field size, directional shifts, and different delivery time. In addition, similar variations were tested with the automated delivery verification program that compared the treatment parameters in the machine delivery logs to the ones in the plan. To test the software, a 3-field conformal plan was generated as the baseline. Results: ArcCHECK noted at least a 13% decrease in passing rate from baseline in the following scenarios: gantry rotation of 1 degree from plan, 5mm change in field size, 2mm lateral shift, and delivery time decrease. Ion chamber measurements remained consistent for these variations except for the 5 second decrease in delivery time scenario which resulted in an 8% difference from baseline. The delivery verification software was able to detect and report the simulated errors such as when the gantry was rotated by 0.6 degrees, the beam weighting was changed by a percent, a single multileaf collimator was moved by 1cm, and the dose was changed from 2 to 1.8Gy. Conclusion: The results show that the current tools used for patient specific QA are capable of detecting small errors in RT delivery with presence of magnetic field.

60 APPLIED LIFE SCIENCES↗

Kinetic-scale flux rope reconnection in periodic and line-tied geometries

The collisionless reconnection of two parallel flux ropes driven by both the coalescence and kink instabilities is examined using fully kinetic simulations in periodic and line-tied geometries. The three-dimensional reconnection rate is computed from the maximum of the quasi-potential, Ξ≡−∫E·dℓ, where the integral of the electric field is taken along the magnetic field lines across the system. In periodic simulations in which the kink mode is nearly suppressed, reconnection is driven by the coalescence instability, and the peak rate is within 3%–8% of comparable 2D simulations. When a strong kink growth is observed, the peak reconnection rate drops by 10%–25%, and there is a larger drop for lower guide field. With line-tied boundary conditions, the kink instability plays a key role in allowing the flux ropes to interact and partially reconnect. In this limit, the field lines with maximum quasi-potential are associated with a quasi-separatrix layer, and the electric field along these special field lines is supported predominantly by the divergence of the electron pressure tensor. Both of these features, along with the observed reconnection rate, are consistent with recent laboratory experiments on kinetic-scale flux ropes. In kinetic simulations, the non-gyrotropic pressure tensor terms contribute significantly more to the reconnecting electric field than do the gyrotropic terms, while contributions from the electron inertia are significant for field lines adjacent to the quasi-separatrix layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lower Hybrid Drift Waves During Guide Field Reconnection

Generation and propagation of lower hybrid drift wave (LHDW) near the electron diffusion region (EDR) during guide field reconnection at the magnetopause is studied with data from the Magnetospheric Multiscale mission and a theoretical model. Inside the current sheet, the electron beta (β e ) determines which type of LHDW is excited. Inside the EDR, where the electron beta is high (β e ~5), the long-wavelength electromagnetic LHDW is observed propagating obliquely to the local magnetic field. In contrast, the short-wavelength electrostatic LHDW, propagating nearly perpendicular to the magnetic field, is observed slightly away from the EDR, where β e is small (~0.6). These observed LHDW features are explained by a local theoretical model, including effects from the electron temperature anisotropy, finite electron heat flux, electrostatics, and parallel current. The short-wavelength LHDW is capable of generating significant drag force between electrons and ions.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EFFECT OF INTERMITTENT GYRO-SCALE SLAB TURBULENCE ON PARALLEL AND PERPENDICULAR COSMIC-RAY TRANSPORT

Earlier work based on nonlinear guiding center (NLGC) theory suggested that perpendicular cosmic-ray transport is diffusive when cosmic rays encounter random three-dimensional magnetohydrodynamic turbulence dominated by uniform two-dimensional (2D) turbulence with a minor uniform slab turbulence component. In this approach large-scale perpendicular cosmic-ray transport is due to cosmic rays microscopically diffusing along the meandering magnetic field dominated by 2D turbulence because of gyroresonant interactions with slab turbulence. However, turbulence in the solar wind is intermittent and it has been suggested that intermittent turbulence might be responsible for the observation of 'dropout' events in solar energetic particle fluxes on small scales. In a previous paper le Roux et al. suggested, using NLGC theory as a basis, that if gyro-scale slab turbulence is intermittent, large-scale perpendicular cosmic-ray transport in weak uniform 2D turbulence will be superdiffusive or subdiffusive depending on the statistical characteristics of the intermittent slab turbulence. In this paper we expand and refine our previous work further by investigating how both parallel and perpendicular transport are affected by intermittent slab turbulence for weak as well as strong uniform 2D turbulence. The main new finding is that both parallel and perpendicular transport are the net effect of an interplay between diffusive and nondiffusive (superdiffusive or subdiffusive) transport effects as a consequence of this intermittency.

79 ASTRONOMY AND ASTROPHYSICS↗

Trapped particles at a magnetic discontinuity

At a tangential discontinuity between two constant magnetic fields a layer of trapped particles can exist, this work examines the conditions under which the current carried by such particles tends to maintain the discontinuity. Three cases are examined. If the discontinuity separates aligned vacuum fields, the only requirement is that they be antiparallel. With arbitrary relative orientations, the field must have equal intensities on both sides. Finally, with a guiding center plasma on both sides, the condition reduces to a relation which is also derivable from hydromagnetic theory. Arguments are presented for the occurrence of such trapped modes in the magnetopause and for the non-existence of specular particle reflection.

Stern, D. P.↗

Magneto mitochondrial dysfunction mediated cancer cell death using intracellular magnetic nano-transducers

Mitochondria are crucial regulators of the intrinsic pathway of cancer cell death. The high sensitivity of cancer cells to mitochondrial dysfunction offers opportunities for emerging targets in cancer therapy. Herein, magnetic nano-transducers, which convert external magnetic fields into physical stress, are designed to induce mitochondrial dysfunction to remotely kill cancer cells. Spindle-shaped iron oxide nanoparticles were synthesized to maximize cellular internalization and magnetic transduction. The magneto-mechanical transduction of nano-transducers in mitochondria enhances cancer cell apoptosis by promoting a mitochondrial quality control mechanism, referred to as mitophagy. Furthermore, in the liver cancer animal model, nano-transducers are infused into the local liver tumor via the hepatic artery. After treatment with a magnetic field, in vivo mitophagy-mediated cancer cell death was also confirmed by mitophagy markers, mitochondrial DNA damage assay, and TUNEL staining of tissues. This study is expected to contribute to the development of nanoparticle-mediated mitochondria-targeting cancer therapy and biological tools, such as magneto-genetics.

60 APPLIED LIFE SCIENCES↗

Response to “Comment on ‘Modification of Lie's transform perturbation theory for charged particle motion in a magnetic field’” [Phys. Plasmas 30 , 104701 (2023)]

Dr. Brizard's comment on my work is based on a conceived procedure that does not come from my work. The defense of his claim that the modification of the so-called standard Lie's transform theory is unnecessary is also unsupported. This response reveals in detail the inconsistency issues in the so-called standard Lie's transform theory by analyzing both its results and root causes. The problem in the so-called standard Lie's transform theory is beyond the issue to take into account the ordering difference between the guiding center motion and gyromotion. Here, the inconsistent commutation of derivative and limit causes another issue. In addition, the so-called standard Lie's transform formulation leads to an unnecessarily lengthy and tedious derivation process for a one or two page task under the singular (or renormalized) formalism described in my paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar Dynamics Observatory Guidance, Navigation, and Control System Overview

The Solar Dynamics Observatory (SDO) was designed and built at the Goddard Space Flight Center, launched from Cape Canaveral on February 11, 2010, and reached its final geosynchronous science orbit on March 16, 2010. The purpose of SDO is to observe the Sun and continuously relay data to a dedicated ground station. SDO remains Sun-pointing throughout most of its mission for the instruments to take measurements of the Sun. The SDO attitude control system (ACS) is a single-fault tolerant design. Its fully redundant attitude sensor complement includes sixteen coarse Sun sensors (CSSs), a digital Sun sensor (DSS), three two-axis inertial reference units (IRUs), and two star trackers (STs). The ACS also makes use of the four guide telescopes included as a part of one of the science instruments. Attitude actuation is performed using four reaction wheels assemblies (RWAs) and eight thrusters, with a single main engine used to provide velocity-change thrust for orbit raising. The attitude control software has five nominal control modes, three wheel-based modes and two thruster-based modes. A wheel-based Safehold running in the attitude control electronics box improves the robustness of the system as a whole. All six modes are designed on the same basic proportional-integral-derivative attitude error structure, with more robust modes setting their integral gains to zero. This paper details the final overall design of the SDO guidance, navigation, and control (GN&C) system and how it was used in practice during SDO launch, commissioning, and nominal operations. This overview will include the ACS control modes, attitude determination and sensor calibration, the high gain antenna (HGA) calibration, and jitter mitigation operation. The Solar Dynamics Observatory mission is part of the NASA Living With a Star program, which seeks to understand the changing Sun and its effects on the Solar System, life, and society. To this end, the SDO spacecraft carries three Sun-observing instruments: Helioseismic and Magnetic Imager (HMI), led by Stanford University; Atmospheric Imaging Assembly (AIA), led by Lockheed Martin Space and Astrophysics Laboratory; and Extreme Ultraviolet Variability Experiment (EVE), led by the University of Colorado. The basic mission is to observe the Sun for a very high percentage of the 5-year mission (10-year goal) with long stretches of uninterrupted observations and with constant, high-data-rate transmission to a dedicated ground station to be located in White Sands, New Mexico. These goals guided the design of the spacecraft bus that will carry and service the three-instrument payload. Overarching design goals for the bus are geosynchronous orbit, near-constant Sun observations with the ability to fly through eclipses, and constant HGA contact with the dedicated ground station. A three-axis stabilized ACS is needed both to point at the Sun accurately and to keep the roll about the Sun vector correctly positioned with respect to the solar north pole. This roll control is especially important for the magnetic field imaging of HM I. The mission requirements have several general impacts on the ACS design. Both the AIA and HMI instruments are very sensitive to the blurring caused by jitter. Each has an image stabilization system (ISS) with some ability to filter out high frequency motion, but below the bandwidth of the ISS the control system must compensate for disturbances within the ACS bandwidth or avoid exciting jitter at higher frequencies. Within the ACS bandwidth, the control requirement imposed by AIA is to place the center of the solar disk no more than 2 arc sec, 3 , from a body-defined target based on one of the GTs that accompany the instrument. This body-defined target, called the science reference boresight (SRB), was determined from the postlaunch orientation of the GTs by averaging the bounding telescope boresights for pitch to get a pitch SRB coordinate, and by averaging the bounding boresights for yaw toet the yaw SRB coordinate. The location of this SRB in the 0.5-deg field-of-view for each GT then becomes the central target for each telescope; one GT is selected for use as the ACS controlling guide telescope (CGT) at any given time. Fine Sun-pointing is effected based on this SRB for all three instruments when the Sun is within the linear range of the CGT. In addition to limiting jitter, HMI science requires averaging several observations, making the instrument sensitive to low frequency motion that induces differential motion between each observation. This requires the spacecraft attitude to be stable about the roll axis to approximately 10 arcsec over a ten-minute period. Instrument calibrations require that the spacecraft point the SRB up to 2.5 degrees in pitch and yaw away from the center of the Sun, placing the Sun outside the field-of-view of the guide telescopes. In such instances, when the GTs cannot provide the definitive target for the ACS, on-board attitude determination combined with ephemeris prediction of the Sun direction must provide the definitive target. EVE is capable of observing the Sun with less dependence on attitude control. However, the ground data processing needs for calibrations result in the most strict attitude knowledge requirements for the mission: [35,70,70] arcsec, 3 , of knowledge with respect to the center of the solar disk. In addition to driving the ACS sensor selection, the knowledge requirements, which have their effect primarily during Inertial mode calibrations, drive the accuracy requirements for the solar ephemeris. The need to achieve and maintain geosynchronous orbit (GEO) drove the need for high-efficiency propulsive systems and appropriate attitude control. The main engine provided high specific impulse for the maneuvers to attain GEO, while the smaller ACS thrusters managed the disturbance torques of the larger engine and provided the capability for much smaller adjustment burns on orbit. SDO s large solar profile means that solar radiation pressure is a large torque disturbance, and the momentum buildup from this disturbance and the GEO altitude drives the ACS to use thrusters to manage vehicle momentum. The demanding data capture budget for the mission, however, requires SDO to avoid frequent thruster maneuvers, while concerns about on-orbit jitter restrict the maximum desired wheel speeds desired from the RWAs. The plan for on-orbit wheel speed and momentum management will be discussed as well as what is now being done in operation after the jitter environment was characterized. The SDO ACS hardware complement is single-fault tolerant. Two main processors carry virtually identical copies of the command and data handling and ACS software, and two identical attitude control electronics (ACE) boxes carry Coldfire processors with contingency ACS software and other hardware interface cards; the ACE structure allows reaction wheels to be commanded by the Sun-pointing Safehold independent of the Mil Std 1553 data bus. The sixteen Adcole CSSs are grouped into primary and backup sets of eight sensors, each set providing the ability to calculate a sun vector. Each set of eight eyes provides full 4 -steradian coverage. The Adcole DSS comprises an optics head and a separate electronics box providing a 1553 data interface. The electronics box is mounted inside the Faraday cage created by the spacecraft bus module. The DSS head with its 32- deg square FOV is mounted on the instrument module with its boresight along the spacecraft X axis, nearly aligned with the Sun during observations. Adcole has designed the DSS calibration parameters so that the accuracy is 0.24 arcminutes within 10 deg of the boresight, and diminishes to 3 arcminutes as the Sun moves towards the edges of its FOV . This DSS calibration scheme provides higher accuracy attitude determination over the range of the instrument calibration maneuvers.

Morgenstern, Wendy M.↗

Observation of stationary filaments with resonant magnetic perturbations in NSTX

The application of resonant magnetic perturbations (RMPs) induces striated heat fluxes on the divertor plate in tokamaks. These striated heat fluxes were previously considered strike point splitting by the intersection between the divertor and predicted magnetic lobe structures. Recently, the existence of stationary 3D filaments has been observed for the first time in National Spherical Torus Experiment (NSTX) plasmas with toroidal mode number n = 3 RMPs. Magnetic field line tracing of these filaments from the midplane to the divertor is consistent with the quantity and the radial and toroidal location of striated heat fluxes observed on the divertor. This study suggests that divertor striated heat flux patterns are linked to these stationary filaments rather than to strike point splitting or magnetic lobe structures for NSTX. This finding will help guide future efforts to understand the heat flux striations in NSTX with RMPs in order to control and reduce the divertor peak heat flux.

RMPs↗

Variational Self-Consistent Theory for Beam-Loaded Cavities

A new variational theory is presented for beam loading in microwave cavities. The beam{field interaction is formulated as a dynamical interaction whose stationarity according to Hamilton’s principle will naturally lead to steady-state solutions that indicate how a cavity’s resonant frequency, Q and optimal coupling coefficient will detune as a result of the beam loading. A driven cavity Lagrangian is derived from first principles, including the effects of cavity wall losses, input power and beam interaction. The general formulation is applied to a typical klystron input cavity to predict the appropriate detuning parameters required to maximize the gain (or modulation depth) in the average Lorentz factor boost, (Δ γ). Numerical examples are presented, showing agreement with the general detuning trends previously observed in the literature. The developed formulation carries several advantages for beam-loaded cavity structures. It provides a self-consistent model for the dynamical (nonlinear) beam{field interaction, a procedure for maximizing gain under beam-loading conditions, and a useful set of parameters to guide cavity-shape optimization during the design of beam-loaded systems. Enhanced clarity of the physical picture underlying the problem seems to be gained using this approach, allowing straightforward inclusion or exclusion of different field configurations in the calculation and expressing the final results in terms of measurable quantities. Two field configurations are discussed for the klystron input cavity, using finite magnetic confinement or no confinement at all. Formulating the problem in a language that is directly accessible to the powerful techniques found in Hamiltonian dynamics and canonical transformations may potentially carry an additional advantage in terms of analytical computational gains, under suitable conditions

43 PARTICLE ACCELERATORS↗

The propagation of low-frequency whistler waves driven by ion beams in the magnetotail

The generation and propagation of low-frequency whistler waves excited by ion beams in the plasma sheet boundary layer are followed using standard ray tracing techniques and assuming a Harris-type neutral sheet magnetic field profiles. The density is chosen such that the total pressure remains constant. The wave energy is calculated along the wave path taking into account growth due to the ion beam while the wave is in the plasma sheet boundary layer as well as damping due to resonant interactions with the background plasma. The results show that the electromagnetic waves are guided toward the central plasma sheet by the plasma gradients but are damped out before reaching the neutral plane itself due to Cerenkov resonance with the hot central plasma sheet background ions. The amplitudes and final positions of the waves depend on the temperature of the background plasma, the ion beam drift speed, and the ion beam thermal speed.

Burinskaia, T.↗

Magnetic attachment mechanism

A magnetic attachment mechanism adapted for interfacing with the manipulator arm (11) of a remote manipulator system and comprising a pair of permanent magnets (31,32) of rare earth material which are arranged in a stator-rotor relationship. The rotor magnet (32), is journalled for rotation about its longitudinal axis between pole plates (35,36) of the stator magnet (31), each of which includes an adhering surface (35a,36a). In a first rotary position corresponding to the ON condition, each of the poles of the rotor magnet (32) is closely adjacent a stator magnet pole plate of like polarity whereby the respective magnet fields are additive for producing a strong magnetic field emanating from the adhering surfaces (35a,36a) for attracting a ferrous magnetic plate 20, or the like, affixed to the payload (20 or 50). When the rotor magnet (32) is rotated to a second position corresponding to the OFF condition, each of the poles of the rotor magnet (31) is disposed closely adjacent a pole plate of unlike polarity whereby the magnetic fields of the magnets are in cancelling relationship at the adhering surfaces (35a,36a) which permits the release of a payload. An actuator (51 or 70) for selectively rotating the rotor magnet (32) between the ON and OFF positions is provided for interfacing and connecting the magnetic attachment mechanism with a manipulator arm. For effecting an optimal rigidized attachment the payload is provided with guides (91,92) cooperable with guides (96,16,17) on the housing of the mechanism for directing adhering surfaces (35a,36a) of the polar plates to the ferrous plate (20).

Harwell, William D.↗

Effect of the solenoid in various conditions of the laser ion source at Brookhaven National Laboratory

In the laser ion source (LIS) at the Brookhaven National Laboratory (BNL), a solenoid is used to guide the laser ablation plasma and modulate the extracted beam current. Many types of ion species are guided. In some cases, the plasma plume is injected into the solenoid away from the solenoidal axis. To investigate the effects of the solenoid on the beam extracted from the plasma that has different properties, the beam current was measured in the setup of the LIS at the BNL. The beam current of Li, Al, Si, Fe, and Au increased when the magnetic field was applied. For most of the species the peak current and the total charge within a single beam pulse increased around 10 times with a magnetic field less than 100 G. In addition, for some species the rate of increase of the peak currents became smaller when the magnetic flux densities were larger than certain values depending on the species. In this case, the current waveforms were distorted. At the same magnetic field value, the field was more effective on lighter species than on heavier ones. When plasma was injected offset from the axis of the solenoid, peak current and total charge became half of those without offset. The experimental data are useful for the operation of the LIS at the BNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Divertor detachment in the pre-fusion power operation phase in ITER during application of resonant magnetic perturbations

Detachment of the divertor plasma during application of resonant magnetic perturbation (RMP) fields is evaluated for hydrogen H-mode plasma during the first pre-fusion power operation (PFPO-1) phase in ITER by 3D plasma boundary modelling with EMC3–EIRENE. Plasma response effects from a linearized, resistive, single fluid MHD model are discussed, which includes partial screening of the externally applied field—but also field amplification near the separatrix. Furthermore, this field amplification is found to play a pivotal role for the magnetic footprint on the divertor targets, but is sensitive to model parameters. Extensions of the footprint beyond the straight portions of the ITER vertical divertor targets, optimized for high stationary heat flux handling, may be possible depending on the level of toroidal rotation in the plasma. Exhaust from the bulk plasma is guided by the helical corrugations (lobes) of the perturbed separatrix, and this results in an upstream heat flux that is distributed over these lobes with lower peak values than in the typical radial heat flux profiles seen in the absence of magnetic perturbations. As a consequence, an earlier onset (with respect to the upstream density) of detachment is found in the traditional strike zone when RMPs are applied, but secondary, non-axisymmetric strike locations appear—and those remain attached at temperatures above 10 eV. Neon seeding can mitigate these non-axisymmetric heat loads, but this becomes less efficient for large magnetic footprints.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of external kink and fishbone-like modes on energetic particle transport in tokamak plasmas

Transport and loss of beam injected energetic particles (EPs) due to three-dimensional perturbations, associated with the external kink (XK) instability and fishbone-like mode (FLM), are numerically investigated utilizing the guiding center following code ORBIT for static toroidal plasmas in HL-2A. The perturbation structure for the XK is computed by the MARS-F code and then mapped to the Boozer coordinates as defined in ORBIT. The simulation shows that the EP profile experiences a significant change in the middle of the plasma column, when the XK-induced radial magnetic field perturbation amplitude, normalized by the equilibrium field, exceeds a threshold value of about 10 -2 . The EP transport is found to be dominated by a diffusion process instead of convection. Furthermore, by scanning the perturbation frequency as a free parameter while maintaining the XK mode structure (thus mimicking the FLM as observed in DIII-D and JT-60U tokamaks), redistribution and loss of EPs are found to be substantially enhanced due to strong resonances between the FLM and EPs, when the mode frequency exceeds a threshold value of ~2 kHz for the case considered. For either XK or FLM, the response of passing EPs to the perturbation is dominant due to the assumed tangential neutral beam injection. Most lost EPs due to these instabilities are initially passing particles but are eventually lost through trapped orbits.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-H-BRA-05: A System Design for Integration of An Interior MRI and a Linear Accelerator

Purpose: MRI is a highly desirable modality to guide radiation therapy but it is difficult to combine a conventional MRI scanner directly with a linear accelerator (linac). An interior MRI (iMRI) concept has been proposed to acquire MRI images within a small field of view only covering targets and immediate surrounding tissues. The objective of this project is to design an interior MRI system to work with a linac using a magnet to provide a field around 0.2T in a cube of 20cm per side, and perform image reconstruction with a slightly inhomogeneous static magnetic fields. Methods: All the results are simulated using a commercially available software package, FARADY. In our design, a ring structure holds the iMRI system and also imbeds a linac treatment head. The ring is synchronized to the linac gantry rotation. Half of the ring is made of steel and becomes a magnetic flux return path (yoke) so that a strong magnetic field will be limited inside the iron circuit and fringe fields will be very weak. In order to increase the static magnetic field homogeneity, special steel magnet boots or tips were simulated. Three curved boots were designed based on two-dimensional curves: arc, parabola and hyperbola. Results: Different boot surfaces modify magnetic field distributions differently. With the same pair of neodymium-iron-boron (NdFeB) magnets, the magnetic induction at the centers are 0.217T, 0.201T, 0.204T, and 0.212T for flat, arc, parabola and hyperbola boots, respectively. The hyperbola boots lead to the most homogeneous results, the static magnetic field deviations are within 0.5% in a cube of 20cm, and can be further improved using shimming techniques. Conclusion: This study supports the concept of an iMRI design. Successful development of iMRI will provide crucial information for tumor delineation in radiation therapy.