Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Initial results from the ISEE-1 and -2 plasma wave investigation

A survey of initial results from the plasma-wave investigation on the ISEE 1 and 2 spacecraft is presented. The plasma-wave instruments employed are designed to provide measurements of the electric and magnetic fields of plasma waves over the frequency range from about 5 Hz to 300 kHz. Several representative satellite passes are analyzed in detail and discussed. The results considered are shown to demonstrate the very high-quality data being obtained with the instruments and to illustrate the wide range of magnetospheric plasma-physics problems that can be treated with the ISEE spacecraft. Comparisons of plasma-wave spectra between the two spacecraft are performed which indicate the great advantages of using two spacecraft in similar orbits to unravel the complex spatial and temporal variations that occur in the magnetosphere.

Gurnett, D. A.↗

An innovative on-board processor for lightsats

The Applied Physics Laboratory (APL) has developed a flightworthy custom microprocessor that increases capability and reduces development costs of lightsat science instruments. This device, called the FRISC (FORTH Reduced Instruction Set Computer), directly executes the high-level language called FORTH, which is ideally suited to the multitasking control and data processing environment of a spaceborne instrument processor. The FRISC will be flown as the onboard processor in the Magnetic Field Experiment on the Freja satllite. APL has achieved a significant increase in onboard processing capability with no increase in cost when compared to the magnetometer instrument on Freja's predecessor, the Viking satellite.

Henshaw, R. M.↗

Secondary Electron Emission from Dust and Its Effect on Charging

Hydrogen plasma is produced in a plasma chamber by striking discharge between incandescent tungsten filaments and the permanent magnetic cage [1], which is grounded. The magnetic cage has a full line cusped magnetic field geometry used to confine the plasma elements. A cylindrical Langmuir probe is used to study the plasma parameters in various discharge conditions. The charge accumulated on the dust particles is calculated using the capacitance model and the dust current is measured by the combination of a Faraday cup and an electrometer at different discharge conditions. It is found Secondary electron emission from dust having low emission yield effects the charging of dust particles in presence of high energetic electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar imaging vector magnetograph

This report describes an instrument which has been constructed at the University of Hawaii to make observations of the magnetic field in solar active regions. Detailed knowledge of active region magnetic structures is crucial to understanding many solar phenomena, because the magnetic field both defines the morphology of structures seen in the solar atmosphere and is the apparent energy source for solar flares. The new vector magnetograph was conceived in response to a perceived discrepancy between the capabilities of X ray imaging telescopes to be operating during the current solar maximum and those of existing magnetographs. There were no space-based magnetographs planned for this period; the existing ground-based instruments variously suffered from lack of sensitivity, poor time resolution, inadequate spatial resolution or unreliable sites. Yet the studies of flares and their relationship to the solar corona planned for the 1991-1994 maximum absolutely required high quality vector magnetic field measurements. By 'vector' measurements we mean that the observation attempts to deduce the complete strength and direction of the field at the measurement site, rather than just the line of sight component as obtained by a traditional longitudinal magnetograph. Knowledge of the vector field permits one to calculate photospheric electric currents, which might play a part in heating the corona, and to calculate energy stored in coronal magnetic fields as the result of such currents. Information about the strength and direction of magnetic fields in the solar atmosphere can be obtained in a number of ways, but quantitative data is best obtained by observing Zeeman-effect polarization in solar spectral lines. The technique requires measuring the complete state of polarization at one or more wavelengths within a magnetically sensitive line of the solar spectrum. This measurement must be done for each independent spatial point for which one wants magnetic field data. All the measurements need to be done in a time short compared to the time scale for changes of the solar features being observed. Were it possible, one would want to record all the needed data simultaneously, since temporal variation of atmospheric seeing degrades both the image and the polarization sensitivity. Since the measurements must span four dimensions, two spatial plus polarization and wavelength, we had some freedom to design the instrument to favor some dimensions over others in terms of simultaneity. Our earlier instrument, the Haleakala Stokes Polarimeter, records a range of wavelengths spanning two spectral lines in each reading, but requires two seconds to determine the polarization state and obtains spatial information only by assembling a long sequence of measurements at single locations on the sun. The new instrument sacrifices spectral detail and accuracy in favor of greatly improved imaging characteristics. The scientific goals for this instrument were to measure surface magnetic fields with enough accuracy to permit calculations of photospheric currents, but with a field of view covering an entire typical active region, high spatial resolution, and a fast enough temporal cadence for detecting flare-associated changes in magnetic structures.

Canfield, Richard C.↗

PolLux: A new facility for soft x-ray spectromicroscopy at the Swiss Light Source

We report on the successful installation and operation of a scanning transmission x-ray microspectroscope (STXM) at the PolLux facility at the Swiss Light Source. This integration of an advanced STXM with improved sample handling capabilities and a novel beamline provides unique capabilities. PolLux uses linearly or circularly polarized x-rays from a bending magnet with an extended photon energy range (200-1400 eV). It is therefore well suited to determine a sample's quantitative chemical composition, molecular orientation, or thickness of organic as well as condensed matter materials. The local magnetic state of magnetic thin films is accessible through fast helicity switching by steering the electron beam off axis through the bending magnet. Ex vacuo girder movers allow fast and highly reproducible (<1 {mu}m) alignment of the instrument with respect to the photon beam. The present spatial resolution is {approx}20 nm, limited by the zone plates utilized. The instrument has the stability and positional resolution to operate with much higher resolution optics as it becomes available. In addition to characterization experiments, we present several typical examples from materials research and environmental science to exemplify the capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-sensitive scanning laser magneto-optical imaging system

A high-sensitive scanning laser magneto-optical (MO) imaging system has been developed. The system is mainly composed of a laser source, galvano meters, and a high-sensitive differential optical-detector. Preliminary evaluation of system performance by using a Faraday indicator with a Faraday rotation coefficient of 3.47x10{sup -5} rad/{mu}m Oe shows a magnetic sensitivity of about 5 {mu}T, without any need for accumulation or averaging processing. Using the developed MO system we have succeeded in the fast and quantitative imaging of a rotationally symmetric magnetic field distribution around an YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO) strip line applied with dc-biased current, and also succeeded in the detection of quantized fine signals corresponding to magnetic flux quantum generation in a superconducting loop of an YBCO Josephson vortex flow transistor. Thus, the developed system enables us not only to do fast imaging and local signal detection but also to directly evaluate both the strength and direction of a magnetic signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A portable high-field pulsed-magnet system for single-crystal x-ray scattering studies

We present a portable pulsed-magnet system for x-ray studies of materials in high magnetic fields (up to 30 T). The apparatus consists of a split-pair of minicoils cooled on a closed-cycle cryostat, which is used for x-ray diffraction studies with applied field normal to the scattering plane. A second independent closed-cycle cryostat is used for cooling the sample to near liquid helium temperatures. Pulsed magnetic fields ({approx}1 ms in total duration) are generated by discharging a configurable capacitor bank into the magnet coils. Time-resolved scattering data are collected using a combination of a fast single-photon counting detector, a multichannel scaler, and a high-resolution digital storage oscilloscope. The capabilities of this instrument are used to study a geometrically frustrated system revealing strong magnetostrictive effects in the spin-liquid state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ON THE PROPERTIES OF SLOW MHD SAUSAGE WAVES WITHIN SMALL-SCALE PHOTOSPHERIC MAGNETIC STRUCTURES

The presence of magnetoacoustic waves in magnetic structures in the solar atmosphere is well-documented. Applying the technique of solar magneto-seismology (SMS) allows us to infer the background properties of these structures. Here, we aim to identify properties of the observed magnetoacoustic waves and study the background properties of magnetic structures within the lower solar atmosphere. Using the Dutch Open Telescope and Rapid Oscillations in the Solar Atmosphere instruments, we captured two series of high-resolution intensity images with short cadences of two isolated magnetic pores. Combining wavelet analysis and empirical mode decomposition (EMD), we determined characteristic periods within the cross-sectional (i.e., area) and intensity time series. Then, by applying the theory of linear magnetohydrodynamics (MHD), we identified the mode of these oscillations within the MHD framework. Several oscillations have been detected within these two magnetic pores. Their periods range from 3 to 20 minutes. Combining wavelet analysis and EMD enables us to confidently find the phase difference between the area and intensity oscillations. From these observed features, we concluded that the detected oscillations can be classified as slow sausage MHD waves. Furthermore, we determined several key properties of these oscillations such as the radial velocity perturbation, the magnetic field perturbation, and the vertical wavenumber using SMS. The estimated range of the related wavenumbers reveals that these oscillations are trapped within these magnetic structures. Our results suggest that the detected oscillations are standing harmonics, and this allows us to estimate the expansion factor of the waveguides by employing SMS. The calculated expansion factor ranges from 4 to 12.

79 ASTRONOMY AND ASTROPHYSICS↗

High-efficiency cross-beam magnetic electron-impact source for improved miniature Mattauch-Herzog mass spectrometer performance

We describe a newly designed cross-beam magnetic electron-impact ion source (CBM-EI). We demonstrate its superiority in comparison with a conventional source (CB-EI) when used with a commercial miniature sector-field-type, non-scanning mass spectrometer featuring Mattauch-Herzog geometry (MH-MS) and a permanent sector-field magnet. This paper clearly shows the value of the CBM-EI for enhancing MH-MS sensitivity. Unlike secondary electron-multiplier type detectors, the pixelated detector (IonCCD Trade-Mark-Sign ) used in the commercial MH-MS has no gain. The MH-MS/IonCCD system is therefore challenged to compete with time-of-flight and quadrupole MS systems due to their higher ion transmissions and detector gains. Using the new CBM-EI, we demonstrate an instrument sensitivity increase of 20-fold to 100-fold relative to the CB-EI-equipped instrument. This remarkable signal increase by the simple addition of the magnet assembly arises from the magnet-induced gyromotion of the thermionic electrons, which vastly increases the effective path length of the electrons through the ionization region, and the collimated nature of the electron flux, which optimizes the ion transmission through the 100-{mu}m object slit of the MH-MS. Some or all of the realized sensitivity increase may be exchanged for an increase in resolution and/or mass range through the use of a narrower object slit, or for a reduction in ion-source pressure to limit quenching. The CBM-EI should facilitate development of a differentially pumped ion source to extend the lifetime of the filament, especially in otherwise intractable applications associated with oxidizing and corrosive samples.

43 PARTICLE ACCELERATORS↗

Design and Performance of the First BICEP Array Receiver

Branches of cosmic inflationary models, such as slow-roll inflation, predict a background of primordial gravitational waves that imprints a unique odd-parity “B-mode” pattern in the Cosmic Microwave Background (CMB) at amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment targets this primordial signature, the amplitude of which is parameterized by the tensor-to-scalar ratio r, by observing the polarized microwave sky through the exceptionally clean and stable atmosphere at the South Pole. B-mode measurements require an instrument with exquisite sensitivity, tight control of systematics, and wide frequency coverage to disentangle the primordial signal from the Galactic foregrounds. BICEP Array represents the most recent stage of the BK program and comprises four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South Pole during the 2019/2020 austral summer. After 3 full years of observations with 30,000+ detectors, BICEP Array will measure primordial gravitational waves to a precision σ(r) between 0.002 and 0.004, depending on foreground complexity and the degree of lensing removal. Here in this paper, we give an overview of the instrument, highlighting the design features in terms of cryogenics, magnetic shielding, detectors and readout architecture as well as reporting on the integration and tests that are ongoing with the first receiver at 30/40 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron and X-Ray Diffraction Studies of Advanced Materials

The selection of articles in the special topic 'Neutron and X-Ray Studies of Advanced Materials' is based on the materials presented during the TMS 2009 annual meeting in San Francisco, CA, February 15-19, 2009. The development of ultrabrilliant third-generation synchrotron X-ray sources, together with advances in X-ray optics, has created intense X-ray microbeams, which provide the best opportunities for in-depth understanding of mechanical behavior in a broad spectrum of materials. Important applications include ultrasensitive elemental detection by X-ray fluorescence/absorption and microdiffraction to identify phase and strain with submicrometer spatial resolution. X-ray microdiffraction is a particularly exciting application compared with alternative probes of crystalline structure, orientation, and strain. X-ray microdiffraction is nondestructive with good strain resolution, competitive or superior spatial resolution in thick samples, and with the ability to probe below the sample surface. Moreover, the high-energy X-ray diffraction technique provides an effective tool for characterizing the mechanical and functional behavior in various environments (temperature, stress, and magnetic field). At the same time, some neutron diffraction instruments constructed mainly for the purpose of engineering applications can be found at nearly all neutron facilities. The first generation-dedicated instruments designed for studying in-situ mechanical behavior have been commissioned and used, and industrial standards for reliable and repeatable measurements have been developed. Furthermore, higher penetration of neutron beams into most engineering materials provides direct measurements on the distribution of various stresses (i.e., types I, II, and III) beneath the surface up to several millimeters, even tens of millimeters for important industrial components. With X-ray and neutron measurements, it is possible to characterize material behavior at different length scales. It is predicted that the application of these techniques, in combination with theoretical simulations and numerical modeling, will lead to major breakthroughs in materials science in the foreseeable future, which will contribute to the development of materials technology and industrial innovation. Specifically, the use of these techniques provides bulk material properties that further augment new characterization tools including the increased use of atom probe tomography and high-resolution transmission electron microscopy systems. The combination of these techniques greatly assists the material property models that address multi-length-scale mechanisms. Different applications of diffuse scattering for understanding the fundamental materials properties are illustrated in the articles of Welberry et al., Goossens and Welberry, Campbell, Abe et al., Gilles et al., and Zhang et al. Analysis of thin films and two-dimensional structures is described in the articles of Gramlich et al., Brock et al., Vigliante et al., Kuzel et al., and Davydok et al. Recent advances in the line profile analysis are represented by the the articles of Scardi et al., Ungar et al., and Woo et al. Characterization of modern alloys is presented by the articles of Wollmershauser et al., Eidenberger et al., Garlea et al., Jia et al., Soulami et al., Wilson et al., and Wang et al. The collected articles are written by different scientific X-ray and neutron research groups. They represent a general trend in the development and application of diffraction techniques all over the world.

36 MATERIALS SCIENCE↗

Experiments at Jefferson Lab

This chapter presents experiments conducted at Thomas Jefferson National Accelerator Facility (Jefferson Lab), a U.S. Department of Energy national laboratory in Newport News, Virginia. There, physicists exploring the nature of matter make use of the Continuous Electron Beam Accelerator Facility (CEBAF), a DOE Office of Science user facility that enables the research of more than 1,650 scientists worldwide. CEBAF’s precise electron beams can reach energies up to 12 billion electron-volts and exhibit high degrees of polarization. Jefferson Lab’s first experiment began taking data in 1995. Since then, the facility has become a world leader in the study of quantum chromodynamics. Today, experiments are carried out simultaneously in four experimental halls, each with specialized capabilities. The primary instruments in use are focusing or large-acceptance magnetic spectrometers, many of which feature superconducting elements. Jefferson Lab’s physics program provides unprecedented insight into the particles and forces that shape the visible universe.

Achenbach, Patrick [Thomas Jefferson National Acce↗

Agentic workflow enables the recovery of critical materials from complex feedstocks via selective precipitation

We present a multi-agentic workflow for critical materials recovery that deploys a series of AI agents and automated instruments to recover critical materials from produced water and magnet leachates. This approach achieves selective precipitation from real-world feedstocks using simple chemicals, accelerating the development of efficient, adaptable, and scalable separations to a timeline of days, rather than months and years.

Ritchhart, Andrew J.↗

Simulation of the motional Stark effect diagnostic gas-filled torus calibration

Many motional Stark effect diagnostics around the world make use of a calibration procedure in which the observed neutral beam is injected into a gas-filled torus with known vacuum fields. The instrument is calibrated by reconciling measured angles with vacuum magnetic reconstructions through a range of pitch angles. This in situ gas-filled torus calibration most closely approximates the working conditions of the diagnostic and includes effects such as beam and viewing geometries, beam voltages, Faraday and stress induced birefringence (in most cases) of the transmissive optics, as well as the polarimeter response. However, secondary neutrals, produced after ionization then reneutralization of a beam neutral, have been found to contaminate measured angles by emitting Balmer alpha with similar Doppler shifts and Stark polarizations as beam neutrals, but with different polarization angles. Simulation results that show spectral and angle behavior versus calibration parameters such as fill gas pressure will be presented. Data from NSTX and C-Mod will be compared to simulations results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-accuracy X-ray detector calibration based on cryogenic radiometry

Cryogenic electrical substitution radiometers (ESRs) are absolute thermal detectors, based on the equivalence of electrical power and radiant power. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2 %, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity is used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3 %. For some silicon photodiodes, the photocurrent is not linear with the incident radiant power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of compound refractive lens using soft and deep X-ray lithography beamline on Indus-2

X-ray compound refractive lenses (CRL) have been fabricated using Soft and Deep X-ray lithography (SDXRL) beamline on Indus-2. Upto 50 parabolic lenses are fabricated in PMMA using 1X X-ray mask. The mask contains of 20 micron thick gold absorbing pattern on polyimide membrane. The lens fabrication is done by exposing 500 {mu}m thick PMMA sheets to 5-12keV X-rays from Indus-2. The fabricated CRL will be suitable for generating focused X-ray beam of Indus-2 bending magnet source.

43 PARTICLE ACCELERATORS↗

MEASURING THE SOLAR RADIUS FROM SPACE DURING THE 2012 VENUS TRANSIT

We report in this work the determination of the solar radius from observations by the Helioseismic and Magnetic Imager (HMI) and the Atmospheric Imaging Assembly (AIA) instruments on board the Solar Dynamics Observatory during the 2012 June Venus transit of the Sun. Two different methods were utilized to determine the solar radius using images of Sun taken by the HMI instrument. The first technique fit the measured trajectory of Venus in front of the Sun for seven wavelengths across the Fe I absorption line at 6173 Å. The solar radius determined from this method varies with the measurement wavelength, reflecting the variation in the height of line formation. The second method measured the area of the Sun obscured by Venus to determine the transit duration from which the solar radius was derived. This analysis focused on measurements taken in the continuum wing of the line, and applied a correction for the instrumental point spread function (PSF) of the HMI images. Measurements taken in the continuum wing of the 6173 Å line, resulted in a derived solar radius at 1 AU of 959.''57 ± 0.''02 (695, 946 ± 15 km). The AIA instrument observed the Venus transit at ultraviolet wavelengths. Using the solar disk obscuration technique, similar to that applied to the HMI images, analysis of the AIA data resulted in values of R {sub ☉} = 963.''04 ± 0.''03 at 1600 Å and R {sub ☉} = 961.''76 ± 0.''03 at 1700 Å.

79 ASTRONOMY AND ASTROPHYSICS↗