Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

60 APPLIED LIFE SCIENCES↗

Precision X-Band Linac Technologies for Nuclear Photonics Gamma-Ray Sources

Nuclear photonics is an emerging field of research requiring new tools, including high spectral brightness, tunable gamma-ray sources; high photon energy, ultrahigh-resolution crystal spectrometers; and novel detectors. This presentation focuses on the precision linac technology required for Compton scattering gamma-ray light sources, and on the optimization of the laser and electron beam pulse format to achieve unprecedented spectral brightness. Within this context, high-gradient X-band technology will be shown to offer optimal performance in a compact package, when used in conjunction with the appropriate pulse format, and photocathode illumination and interaction laser technologies. The nascent field of nuclear photonics is enabled by the recent maturation of new technologies, including high-gradient X-band electron acceleration, robust fiber laser systems, and hyper-dispersion CPA. Recent work has been performed at LLNL to demonstrate isotope-specific detection of shielded materials via NRF using a tunable, quasi-monochromatic Compton scattering gamma-ray source operating between 0.2 MeV and 0.9 MeV photon energy. This technique is called Fluorescence Imaging in the Nuclear Domain with Energetic Radiation (or FINDER). This work has, among other things, demonstrated the detection of {sup 7}Li shielded by Pb, utilizing gamma rays generated by a linac-driven, laser-based Compton scattering gamma-ray source developed at LLNL. Within this context, a new facility is currently under construction at LLNL, with the goal of generating tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range, at a repetition rate of 120 Hz, and with a peak brightness in the 10{sup 20} photons/(s x mm{sup 2} x mrad{sup 2} x 0.1% bw).

42 ENGINEERING↗

Simultaneous imaging and diffraction in the dynamic diamond anvil cell

The ability to visualize a sample undergoing a pressure-induced phase transition allows for the determination of kinetic parameters, such as the nucleation and growth rates of the high-pressure phase. For samples that are opaque to visible light (such as metallic systems), it is necessary to rely on x-ray imaging methods for sample visualization. Here, we present an experimental platform developed at beamline P02.2 at the PETRA III synchrotron radiation source, which is capable of performing simultaneous x-ray imaging and diffraction of samples that are dynamically compressed in piezo-driven diamond anvil cells. This setup utilizes a partially coherent monochromatic x-ray beam to perform lensless phase contrast imaging, which can be carried out using either a parallel- or focused-beam configuration. The capabilities of this platform are illustrated by experiments on dynamically compressed Ga and Ar. Melting and solidification were identified based on the observation of solid/liquid phase boundaries in the x-ray images and corresponding changes in the x-ray diffraction patterns collected during the transition, with significant edge enhancement observed in the x-ray images collected using the focused-beam. These results highlight the suitability of this technique for a variety of purposes, including melt curve determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PERFORMANCE OF SPECTRALLY SELECTIVE COLLECTOR SURFACES IN A SOLAR-DRIVEN CARNOT SPACE-POWER SYSTEM

A study was made of the theoretical performance of spectrally selective surfaces when used as the collectors of solar energy for driving heat engine cycles in space. Selective surfaces were considered for which the-monochromatic emissivity changed abruptly at specific wavelengths between 0.5 and 10 microns. The Carnot cycle was used as the heat engine, and waste heat was rejected from a black radiator. Systems using both focused and unfocused radiation were considered. It was found that spectrally selective surfaces hold considerable promise as collectors of solar energy in unfocused systems. The efficiency for these is several times greater than that obtainable from black or gray collectors. However, this advantage of spectral selectivity diminishes if the sunlight is focused on the collector. In highly focused systems, such as those using parabolic mirrors, black collectors give substantially the same efficiency as the most ideal spectrally selective surface.

SOLAR PROPULSION↗

A filter-wheel solar radiometer for atmospheric transmission studies

A filter-wheel solar radiometer has been developed for monitoring the atmospheric optical depth at multiple narrow-wavelength intervals in the visible and near IR regions of the spectrum. Measurements of the direct solar radiations are converted to a digital format and stored in punched tape for eventual analysis by a computer. During stable clear weather condition, the instrument is capable of providing monochromatic optical depths to an estimated rms accuracy of 0.005.

Shaw, G. E.↗

Gravitational wave searches with ground tracking networks

Long-term experiments designed to search for gravitational waves (GW) have been performed with the Pioneer 10 and 11 spacecraft, and are planned for NASA's Galileo and ESA's Ulysses spacecraft. The result of a passing monochromatic GW is a sinusoidal modulation of the Doppler series that depends on the round-trip light time (RTLT) to a spacecraft and on the angle between the radiation propagation direction and the spacecraft link. Thus, an ideal experiment must have coverage and monitoring of interplanetary spacecraft during cruise that must be continuous as the earth turns to permit observation of complete three-pulse responses over the RTLT. To achieve this goal, an international 40-day Joint Tracking Experiment (JTE) is planned for the fall of 1987 for continuous tracking of the two spacecraft, when both will be near solar opposition. A diagram of the tracking geometry during the JTE and diagrams illustrating theoretical GW properties are included.

Estabrook, F. B.↗

Development of a new CEDAR for kaon identification at the NA62 experiment at CERN

The NA62 experiment at CERN utilises a differential Cherenkov counter with achromatic ring focus (CEDAR) for tagging kaons within an unseparated monochromatic beam of charged hadrons. The CEDAR-H detector was developed to minimise the amount of material in the path of the beam by using hydrogen gas as the radiator medium. The detector was shown to satisfy the kaon tagging requirements in a test-beam before installation and commissioning at the experiment. The CEDAR-H performance was measured using NA62 data collected in 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescent X-Ray Computed Tomography towards Molecular Imaging: Proof-of-Concept Experiments

By means of fluorescent x-ray computed tomography (FXCT) one can detect and image a distribution of non-radioactive imaging agent, e.g., iodine, in a biomedical subject at a high spatial resolution, so it can be a novel molecular imaging modality. We have been studying an FXCT system using synchrotron radiation for in-vivo imaging brains of small animals such as mouse, or rat. For the purpose, we propose a fast FXCT imaging method based on the novel geometry. In this study, we prove the feasibility of this concept and investigate its imaging properties, including spatial and contrast resolutions and quantitativeness, by imaging an acrylic phantom and a normal mouse brain using a preliminary imaging system with monochromatic synchrotron x rays.

60 APPLIED LIFE SCIENCES↗

Femtosecond time-resolved photoelectron spectroscopy with a vacuum-ultraviolet photon source based on laser high-order harmonic generation

A laser-based tabletop approach to femtosecond time-resolved photoelectron spectroscopy with photons in the vacuum-ultraviolet (VUV) energy range is described. The femtosecond VUV pulses are produced by high-order harmonic generation (HHG) of an amplified femtosecond Ti:sapphire laser system. Two generations of the same setup and results from photoelectron spectroscopy in the gas phase are discussed. In both generations, a toroidal grating monochromator was used to select one harmonic in the photon energy range of 20-30 eV. The first generation of the setup was used to perform photoelectron spectroscopy in the gas phase to determine the bandwidth of the source. We find that our HHG source has a bandwidth of 140 {+-} 40 meV. The second and current generation is optimized for femtosecond pump-probe photoelectron spectroscopy with high flux and a small spot size at the sample of the femtosecond probe pulses. The VUV radiation is focused into the interaction region with a toroidal mirror to a spot smaller than 100 x 100 {mu}m{sup 2} and the flux amounts to 10{sup 10} photons/s at the sample at a repetition rate of 1 kHz. The duration of the monochromatized VUV pulses is determined to be 120 fs resulting in an overall pump-probe time resolution of 135 {+-} 5 fs. We show how this setup can be used to map the transient valence electronic structure in molecular dissociation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comprehensive study of the radiative properties of NO—a first step toward a complete air opacity

Here, in this paper we propose a methodology to calculate the radiative properties of the diatomic molecular constituents of air, and utilize the present approach to model the radiative properties of nitrogen monoxide, NO. We also investigate the important physics involved in calculating accurate radiative quantities for air, such as the Planck and Rosseland mean opacities, and emission and absorption coefficients, as well as the couplings accounted for in rovibrational calculations. Complete active space self-consistent field multi-reference configuration interaction (CAS-MRCI) calculations were performed in order to model the NO X 2 Π, a 4 Π, b 4 Σ - , 1 2 Σ + , 2 2 Σ + , 3 2 Σ + , G 2 Σ - , B' 2 Δ, (C, B) 2 2 Π, (H', L) 3 2 Π, and 1 2 Φ adiabatic states, and calculate the respective molecular data. The γ X 2 Π - A 2 Σ + , ε X 2 Π - D 2 Σ + , β' X 2 Π - B' 2 Δ, '11 000 Å' A 2 Σ + - D 2 Σ + , 'infrared' X 2 Π - X 2 Π and X 2 Π - (C, B) 2 2 Π (δ and β) band systems are investigated in monochromatic spectra calculations, as well as the Ogawa a 4 Π - b 4 Σ - band and several other band systems. Several conclusions are drawn, such as the importance of including the Ogawa band, which has not been included in previous air radiative models or comprehensive line-list calculations, as well as the importance of performing coupled rovibrational line-list calculations in order to accurately calculate the Rosseland means. We also found that the additional band systems modeled here contribute significantly to the total Planck and Rosseland means.

74 ATOMIC AND MOLECULAR PHYSICS↗

Zone Plates for Hard X-Ray FEL Radiation

We investigated theoretically the use of zone plates for the focusing of the European X-ray Free Electron Laser (XFEL). In a finite-element simulation the heat load on zone plates placed in the high intensity x-ray beam was simulated for four different zone plate materials: gold, iridium, tungsten, and CVD diamond. The main result of the calculations is that all zone plates remain below the melting temperature throughout a full XFEL pulse train of 3000 pulses. However, if the zone plate is placed in the direct beam it will experience large and rapid temperature fluctuations on the order of 300 K. The situation is relaxed if the optic is placed behind a monochromator and the fluctuations are reduced to around 20 K. Besides heat load, the maximization of the total efficiency of the complete optical system is an important issue. We calculated the efficiency of different zone plates and monochromator systems and found that the final beam size of the XFEL in combination with its monochromaticity will be important parameters.

43 PARTICLE ACCELERATORS↗

Investigation of Next-Generation Earth Radiation Budget Radiometry

The current effort addresses two issues important to the research conducted by the Thermal Radiation Group at Virginia Tech. The first research topic involves the development of a method which can properly model the diffraction of radiation as it enters an instrument aperture. The second topic involves the study of a potential next-generation space-borne radiometric instrument concept. Presented are multiple modeling efforts to describe the diffraction of monochromatic radiant energy passing through an aperture for use in the Monte-Carlo ray-trace environment. Described in detail is a deterministic model based upon Heisenberg's uncertainty principle and the particle theory of light. This method is applicable to either Fraunhofer or Fresnel diffraction situations, but is incapable of predicting the secondary fringes in a diffraction pattern. Also presented is a second diffraction model, based on the Huygens-Fresnel principle with a correcting obliquity factor. This model is useful for predicting Fraunhofer diffraction, and can predict the secondary fringes because it keeps track of phase. NASA is planning for the next-generation of instruments to follow CERES (Clouds and the Earth's Radiant Energy System), an instrument which measures components of the Earth's radiant energy budget in three spectral bands. A potential next-generation concept involves modification of the current CERES instrument to measure in a larger number of wavelength bands. This increased spectral partitioning would be achieved by the addition of filters and detectors to the current CERES geometry. The capacity of the CERES telescope to serve for this purpose is addressed in this thesis.

Coffey, Katherine L.↗

Comparison of Two Methodologies for Calibrating Satellite Instruments in the Visible and Near Infrared

Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance response in a two-step method. In the first step, the spectral response of the instrument is determined using a nearly monochromatic light source, such a lamp-illuminated monochromator. Such sources only provide a relative spectral response (RSR) for the instrument, since they do not act as calibrated sources of light nor do they typically fill the field-of-view of the instrument. In the second step, the instrument views a calibrated source of broadband light, such as lamp-illuminated integrating sphere. In the traditional method, the RSR and the sphere spectral radiance are combined and, with the instrument's response, determine the absolute spectral radiance responsivity of the instrument. More recently, an absolute calibration system using widely tunable monochromatic laser systems has been developed, Using these sources, the absolute spectral responsivity (ASR) of an instrument can be determined on a wavelength-hy-wavelength basis. From these monochromatic ASRs. the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as integrating spheres. Here we describe the laser-based calibration and the traditional broad-band source-based calibration of the NPP VIIRS sensor, and compare the derived calibration coefficients for the instrument. Finally, we evaluate the impact of the new calibration approach on the on-orbit performance of the sensor.

Barnes, Robert A.↗

Mechanisms of Pressure-Induced Phase Transitions by Real-Time Laue Diffraction

Synchrotron X-ray radiation Laue diffraction is a widely used diagnostic technique for characterizing the microstructure of materials. An exciting feature of this technique is that comparable numbers of reflections can be measured several orders of magnitude faster than using monochromatic methods. This makes polychromatic beam diffraction a powerful tool for time-resolved microstructural studies, critical for understanding pressure-induced phase transition mechanisms, by in situ and in operando measurements. The current status of this technique, including experimental routines and data analysis, is presented along with some case studies. The new experimental setup at the High-Pressure Collaborative Access Team (HPCAT) facility at the Advanced Photon Source, specifically dedicated for in situ and in operando microstructural studies by Laue diffraction under high pressure, is presented.

36 MATERIALS SCIENCE↗

A large-scale cosmic microwave background anisotropy measurement at millimeter and submillimeter wavelengths

A balloon-borne experiment to measure the anisotropy of the cosmic microwave background radiation at angular scales of 4 deg or greater is reported. The instrument simultaneously measures in four spectral bands centered on 5.6, 8.7, 15.8, and 22.5/cm. Three results are presented: (1) the 95-percent confidence limit for monochromatic anisotropies is 0.0001 or less on angular scales of 10 deg; (2) the Galactic plane dust emission at l = 42 deg is consistent with a nu-squared emissivity law at frequencies above 15/cm, with excess emission below 15/cm; and (3) atmospheric ozone at an altitude of 35 km may form clumps as large as Delta emissivity/emissivity = 0.002.

Page, Lyman A.↗

NSLS-II X-Ray Diagnostics Development

NSLS-II x-ray diagnostics will provide continuous online data of electron beam dimensions, which will be used to derive electron beam emittance and energy spread. It will also provide information of electron beam tilt for coupling evaluation. X-ray diagnostics will be based on imaging of bending magnet and three-pole wiggler synchrotron radiation sources. Diagnostics from three-pole wiggler source will be used to derive particles energy spread. Beta and dispersion functions will have to be evaluated for emittance and particles energy spread calculations. Due to small vertical source sizes imaging need to be performed in x-ray energy range. X-ray optics with high numerical aperture, such as compound refractive lens, will be used to achieve required spatial resolution. Optical setups with different magnifications in horizontal and vertical directions fill be employed to deal with large aspect ratio of the source. X-ray diagnostics setup will include x-ray imaging optics, monochromatization, x-ray imaging and recording components.

43 PARTICLE ACCELERATORS↗