Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

ENDF/B-VIII.0 Augmented Covariance Data: The first iteration

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Verification of Flux Sensitivity Estimates Using the MCNP Tally Perturbation Tool

Nuclear data is commonly used in applications such as nuclear nonproliferation, safeguards, and criticality safety. More specifically, nuclear data is used in predictive simulation codes like the Monte-Carlo N-Particle (MCNP ® ) transport code, Serpent, and similar radiation transport codes. The improvement of nuclear data enables more precise and accurate simulations, which result in higher fidelity designs and reduced operational/procedural costs. Therefore, the improvement of nuclear data is of paramount importance across the nuclear community. Nuclear data is improved and validated through integral benchmark experiments. The design of benchmark experiments is an extensive process; therefore, these experiments are often optimized on multiple characteristics, including sensitivity to the nuclear data, during the design process. Sensitivity is a measure of how much a quantity changes due to changes in independent variables such as experimental configuration. An experimental design that has a larger sensitivity to the nuclear data of interest will have a larger impact on the accuracy and precision of the validated data. Past integral benchmark experiments have primarily used the effective multiplication factor ($k_{eff}$) as the predominant measured quantity; however, experiments designed with other quantities in mind would be able to optimize on validating different areas of the nuclear data. A primary goal of the EUCLID project is to design, constrain, and reduce compensating errors in experiments focused on quantities other than $k_{eff}$ to better validate nuclear data across the board. Currently, there is a capability in MCNP to easily calculate the sensitivity of $k_{eff}$ to specific nuclear data of numerous reactions types and isotopes (KSEN card); however, the sensitivity of other quantities must be estimated in more strenuous manners. For example, the perturbation feature (PERT card) of MCNP can be used to estimate first-order sensitivities of some response in fixed source simulations. A recent announcement revealed that the first- and second-order perturbation features in previous releases of MCNP contained a bug. It was identified that particles were being scored into the wrong energy bin. The bug is in the most recent public release (MCNP6.2); however, a patch has been added to the most up to date version (MCNP6.2.2) that has not been released publicly. A direct comparison of the PERT card results for an F4 (neutron flux averaged over a cell) tally before and after the patch are shown in figure 1. All simulations used in the sensitivity estimates in this report were performed with MCNP6.2.2. This work verifies the patched MCNP perturbation tool by comparing first order sensitivities made using the PERT card to estimates made using manual perturbation of the compact ENDF (ACE) files.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Reaction Data Center Network; International and Asia

The activities of the Nuclear Reaction Data Centre at Hokkaido University and International Network of Nuclear Reaction Data Centre (NRDC) are explained. Finally, collaboration in the nuclear data activities among Asian countries are proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0: The 8 th Major Release of the Nuclear Reaction Data Library with CIELO-project Cross Sections, New Standards and Thermal Scattering Data

We describe the new ENDF/B-VIII.0 evaluated nuclear reaction data library. ENDF/B-VIII.0 fully incorporates the new IAEA standards, includes improved thermal neutron scattering data and uses new evaluated data from the CIELO project for neutron reactions on 1 H, 16 O, 56 Fe, 235 U, 238 U and 239 Pu described in companion papers in the present issue of Nuclear Data Sheets. The evaluations benefit from recent experimental data obtained in the U.S. and Europe, and improvements in theory and simulation. Notable advances include updated evaluated data for light nuclei, structural materials, actinides, fission energy release, prompt fission neutron and γ-ray spectra, thermal neutron scattering data, and charged-particle reactions. Integral validation testing is shown for a wide range of criticality, reaction rate, and neutron transmission benchmarks. In general, integral validation performance of the library is improved relative to the previous ENDF/B-VII.1 library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculations of Astrophysical Reaction Rates Using ENDF/B-VIII.0 Library

Recent observations of neutron stars merger (GW170817) renewed interest in stellar nucleosynthesis. Stellar nucleosynthesis modeling requires fully traceable, unbiased, high fidelity nuclear data. The Evaluated Nuclear Data File (ENDF) libraries contain complete collections of reaction data sets over the nuclear industry standard 10 -5 eV - 20 MeV energy span. For the first time, the (n,γ), (n,fission), (n,p), and (n,α) astrophysical reaction rates were computed within the 0.01-10 GK range of temperatures using the ENDF/B-VIII.0 library, and nuclear Reaction rate Library for astrophysics (REACLIB) fit parameters were deduced. The present results were used to estimate the slow neutron capture timescale. These findings demonstrate the potential astrophysical applications of the ENDF libraries and the complementary relations between the nuclear industry and astrophysics data developments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncovering Where Compensating Errors Could Hide in ENDF/B-VIII.0

Unconstrained physics spaces between two or more nuclear data observables in a library occur when their values can be simultaneously adjusted without violating the uncertainties in either differential information or simulations of relevant integral experiments. Differential data are often too imprecise to fully bound all nuclear data observables of interest for application simulations. Integral data are simulated with combinations of nuclear data so that an error in one observable may be hidden by a counterbalancing error in another. In this manner compensating errors may lurk within nuclear data libraries and these errors have the potential to undermine the predictive power of neutron transport simulations, particularly in situations where there is no conclusive validation experiment that resembles the application of interest. The EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) developed a preliminary workflow to identify these unconstrained physics spaces by bringing together results from a large collection of integral experiments with their simulated counter-parts as well as differential information that have a one-to-one correspondence to nuclear data. This wealth of information is processed by machine learning tools for subsequent refinement by human experts. Here, we show how the EUCLID work-flow is executed by applying it first to 239 Pu and then to 9 Be nuclear data in ENDF/B-VIII.0.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of MCNP6.1 for Criticality Safety of Pu-Metal, -Solution, and -Oxide Systems

Guidance is offered to the Los Alamos National Laboratory Nuclear Criticality Safety division towards developing an Upper Subcritical Limit (USL) for MCNP6.1 calculations with ENDF/B-VII.1 nuclear data for three classes of problems: Pu-metal, -solution, and -oxide systems. A benchmark suite containing 1,086 benchmarks is prepared, and a sensitivity/uncertainty (S/U) method with a generalized linear least squares (GLLS) data adjustment is used to reject outliers, bringing the total to 959 usable benchmarks. For each class of problem, S/U methods are used to select relevant experimental benchmarks, and the calculational margin is computed using extreme value theory. A portion of the margin of sub criticality is defined considering both a detection limit for errors in codes and data and uncertainty/variability in the nuclear data library. The latter employs S/U methods with a GLLS data adjustment to find representative nuclear data covariances constrained by integral experiments, which are then used to compute uncertainties in k eff from nuclear data. The USLs for the classes of problems are as follows: Pu metal, 0.980; Pu solutions, 0.973; dry Pu oxides, 0.978; dilute Pu oxide-water mixes, 0.970; and intermediate-spectrum Pu oxide-water mixes, 0.953.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast neutron leakage spectra of the EUCLID experiment

Special nuclear material in sub-critical and critical configurations measured in integral experiments are important for validation and adjustment of nuclear data. Many different evaluations of nuclear data exist, and these different evaluations can provide different values for individual cross sections that vary due to the uncertainties in differential experiments or lack of such data. For integral experiments, differences in these individual cross sections can have compensating errors, which lead to the same answer. One example of this is the Jezebel critical assembly, where k eff of the system is correctly computed by both ENDF/B-VIII.0 and JEFF-3.3, despite having substantially different underlying evaluated values for specific reactions (such as elastic and inelastic cross sections). To reduce compensating errors in nuclear data, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project has utilized machine learning to design a set of sub-critical and critical experiments. These experiments include slab- and cube-like configurations of 239 Pu in the form of the ZPPR plates. Six different responses were measured on a total of thirteen different configurations. One of these responses, the neutron leakage spectrum, was measured using an EJ301D detector. Finally, the results of the neutron leakage spectra show good agreement (within 1–2 σ ) with the expected spectrum from simulations and will be used in the subsequent nuclear data adjustment done by the EUCLID team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ENDF/B-VIII.1

The ENDF/B-VIII.1 release is the newest evaluated nuclear data library produced, distributed, and recommended by CSEWG for use in nuclear science and technology applications. Among the many key advances, relative to the previous version ENDF/B-VIII.0, are: re-evaluation of 239Pu file by a joint international effort; updated 16,18O, 19F, 28-30Si, 50-54Cr, 55Mn, 54,56,57Fe, 63,65Cu, 139La, 233,235,238U, and 240,241Pu neutron nuclear data by the IAEA-coordinated INDEN collaboration; significant changes for 3He, 6Li, 9Be, 51V, 88Sr, 103Rh, 140,142Ce, Dy, 181Ta, Pt, 206-208Pb, and 234,236U neutron data; new nuclear data for the photo-nuclear, being 196 adopted from the IAEA2019 Photonuclear Data Library and one new file from JENDL-5; and new evaluations for the charged-particle and atomic sublibraries. Numerous thermal neutron scattering kernels were re-evaluated or provided for the very first time. Additionally, new covariance testing was implemented. ENDF/B-VIII.1 reduced bias in the simulations of many integral experiments with particular progress noted for fluorine, copper and stainless steel containing benchmarks. Data issues which had hindered the deployment of ENDF/B-VIII.0 for commercial nuclear power applications in high burn-up situations, were addressed. ENDF/B-VIII.1 data are distributed in both ENDF-6 and GNDS formats.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncovering Where Compensating Errors Could Hide in ENDF/B-VIII.0

Unconstrained physics spaces between two or more nuclear data observables in a library occur when their values can be simultaneously adjusted without violating the uncertainties in either differential information or simulations of relevant integral experiments. Differential data are often too imprecise to fully bound all nuclear data observables of interest for application simulations. Integral data are simulated with combinations of nuclear data so that an error in one observable may be hidden by a counterbalancing error in another. In this manner compensating errors may lurk within nuclear data libraries and these errors have the potential to undermine the predictive power of neutron transport simulations, particularly in situations where there is no conclusive validation experiment that resembles the application of interest. The EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) developed a preliminary workflow to identify these unconstrained physics spaces by bringing together results from a large collection of integral experiments with their simulated counter-parts as well as differential information that have a one-to-one correspondence to nuclear data. This wealth of information is processed by machine learning tools for subsequent refinement by human experts. Here, we show how the EUCLID work-flow is executed by applying it first to 239 Pu and then to 9 Be nuclear data in ENDF/B-VIII.0.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-517: Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK)

Nuclear criticality experiments are essential to the validation of nuclear data used in simulation software. The quality of nuclear data becomes paramount as simulation software becomes more relied upon for criticality safety studies and designs of nuclear systems. To improve the quality of nuclear data, experimenters can design critical experiments that are sensitive to isotope reaction pairs in materials of interest. The efforts conducted by the Organisation for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA) Working Party on Nuclear Criticality Safety (WPNCS) Subgroup 8: Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks (SG8) to categorize benchmarks according to their usefulness for nuclear data validation have been of great importance. Based on the OECD studies benchmark experiments included in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook are concisely used by nuclear data evaluators, criticality safety engineers and others to validate nuclear data and simulation results. A lack of benchmarks sensitive to molybdenum in the (ICSBEP), particularly in the intermediate range, was noted by Los Alamos National Laboratory (LANL), the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN), and Y-12 National Security Site prompting them to submit a joint integral experiment request to the Nuclear Criticality Safety Program (NCSP) in 2019. The request included both HEU and Plutonium systems in order to validate differential nuclear data focusing on the intermediate energy range but also includes thermal and fast configurations. This document represents the preliminary design work for a series of molybdenum integral experiments known as Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron activation of natural materials in a PWR spectrum: feedback on {sup 116m}In relative γ emission intensities and half-life

During the MAESTRO program, carried out between 2011 and 2014 in MINERVE zero power reactor, common Gen-II and Gen-III light water reactor materials were irradiated. For some of these materials, the decay of their activation products was also measured by γ spectrometry. Initially devoted to the measurement of the integral capture cross section by activation and reactivity-oscillation method, these results can also provide useful information on decay data of various radionuclides. This approach of this experiment led to a common roadmap shared by the Experimental Physics Section and the Henri Becquerel National Laboratory to improve decay data in nuclear data libraries. Results discussed in this paper concern the relative emission intensities of the main γ rays of {sup 116m}In. Six irradiations of samples with various physical forms of {sup nat}In were carried out. Measurements were analyzed using decay data from several evaluations and it is shown that γ ray activities are not consistent. Analyses were carried out to provide new relative γ emission intensities from these measurements. The {sup 116m}In half-life has also been measured and shows a good agreement with existing values. Finally, an overview of the foreseen results on additional decay data from the MAESTRO program is given. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Leakage Spectra of the EUCLID Experiment [Abstract]

Integral experiments with sub-critical and critical configurations of special nuclear material are performed in support of nuclear data validation and adjustment. Different nuclear data evaluations may have different values for individual cross sections due to uncertainties in (or lack of) differential experiments, but compensating errors in these data sets can lead to the same k eff results for one application while vastly different for another application. One example of this is 239 Pu, where both ENDF/B-VIII.0 and JEFF-3.3 correctly compute k eff of the Jezebel critical assembly, but the individual contributions from each reaction are vastly different. To help resolve this specific case, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project used machine learning to design a set of experiments to help resolve the compensating errors in 239 Pu. A total of six responses were measured during the experimental campaign, which constrain the data in ways that k eff alone cannot and will be used for adjustment of the nuclear data. One of these responses is the neutron leakage spectrum, which recent work has shown to be useful for constraining the prompt fission neutron spectrum and inelastic scattering. The neutron leakage spectra were measured utilizing a 3 in. right cylinder EJ-301D detector. The measured signal in the detector was deconvoluted using spectrum unfolding techniques, which are presented and compared to simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculating uncertainty on K-effective with MONK10 - 14583

Criticality safety assessments require a demonstration that a particular configuration of fissile material has an adequate sub-critical margin (k-effective sufficiently below unity) to ensure that the risk of criticality under normal operation and accident conditions is acceptable. The required sub-critical margin depends upon the uncertainty in the estimated value of k-effective. The uncertainty in the calculated value of k-effective arises from a number of sources, including: manufacturing tolerances on input data to the code (affecting geometry, compositions and densities), uncertainty in the nuclear data used by the code, stochastic uncertainty resulting from Monte Carlo simulation and modelling approximations/errors, including the inevitable bugs in the software. The ANSWERS Software Service, in collaboration with industrial partners, is developing a number of techniques to better understand and quantify uncertainty on predicted values of k-effective, using MONK. The SPRUCE utility code has been developed to allow uncertainty to be estimated using sampling methods. This can include the sampling of input parameters (including dimensions, compositions and densities) from statistical distributions. It can also include sampling different nuclear data libraries. A set of nuclear data libraries has been generated for this purpose by sampling from statistical distributions that represent the uncertainties in the published nuclear data evaluated files; a set of libraries has been produced for Latin Hypercube Sampling. By varying the input data and nuclear data, separate and combined uncertainties due to manufacturing tolerances and nuclear data can be derived. By performing least squares fitting on the results it is also possible to estimate the contribution of each of the uncertain inputs and a sensitivity method in MONK can break down the nuclear data uncertainty. (authors)

42 ENGINEERING↗

THE INFLUENCE OF CHANGES IN NUCLEAR COVARIANCE DATA ON THE CALCULATION OF Ck FOR HIGHLY ENRICHED URANIUM SOLUTION SYSTEMS

Since their initial development nearly 20 years ago, sensitivity/uncertainty (S/U) techniques have been increasingly applied to criticality safety validation. These techniques can generally be applied quickly and for a range of purposes after the initial investment of calculating sensitivities for a safety analysis model and a range of potential benchmark experiments. This paper discusses these applications and how they have been affected by changes in covariance data libraries.Critical experiment selection is the most prominent area in which S/U methods impact validation efforts. These methods allow for rigorous calculation of similarity between safety analysis models and potential benchmarks. The most widely used of these methods is the integral parameter ck, although other integral parameters such as E and some non-integral parameters have also been explored. The ck parameter calculates the fraction of nuclear data–induced uncertainty shared between an application and an experiment; this metric is predicated on the assessment that nuclear data errors are the most likely source of computational bias. Therefore, values of ck are inherently dependent on the nuclear covariance library used to calculate them and inevitably change when these data change.Past studies have shown how much the ck values can vary, especially in difficult validation cases like burnup credit. These significant changes are the result of differences in the relative uncertainties of nuclides with large sensitivities, and they imply differences in benchmark applicability to the safety analysis model. This paper demonstrates that more common criticality safety models involving single fissile species have significantly less variability of ck between covariance libraries, thus enhancing confidence in the application of S/U methods for experiment selection in these scenarios. This paper presents case studies examining the impact of these changes on some hypothetical safety analysis systems.

Clarity, Justin↗

NNDC Data Services

The National Nuclear Data Center has provided remote access to some of its resources since 1986. The major databases and other resources available currently through NNDC Web site are summarized. The National Nuclear Data Center (NNDC) has provided remote access to the nuclear physics databases it maintains and to other resources since 1986. With considerable innovation access is now mostly through the Web. The NNDC Web pages have been modernized to provide a consistent state-of-the-art style. The improved database services and other resources available from the NNOC site at www.nndc.bnl.govwill be described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using Nuclear Theory, Data and Uncertainties in Monte Carlo Transport Applications

These are slides for a presentation on using nuclear theory, data and uncertainties in Monte Carlo transport applications. The following topics are covered: nuclear data (experimental data versus theoretical models, data evaluation and uncertainty quantification), fission multiplicity models (fixed source applications, criticality calculations), uncertainties and their impact (integral quantities, sensitivity analysis, uncertainty propagation).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗