Search NASA⌕ Search

SEARCH · Search NASA

Results for “Output”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Cardiovascular Responses to Simulated Spaceflight: Molecular Signatures and Surrogate Outputs to Measure CVD Risk

During extended space missions beyond low Earth orbit, astronauts will encounter prolonged periods of weightlessness and low dose space radiation. Previous studies have shown that exposure to small doses of high LET radiation (< 50 cGy) can lead to both short-term and long-term alterations in heart function, structure and underlying molecular mechanisms. In this study, we aim to identify the molecular signature associated with the cardiovascular response to simulated galactic cosmic radiation (5-ion GCR) alone or in combination with simulated weightlessness at time intervals relevant to mission length and recovery. Additionally, we aim to determine whether sex impacts cardiovascular responses to these spaceflight factors. Our overarching goal is to enhance our understanding of the cardiovascular risks associated with extended space missions and the clinical endpoints they suggest. We hypothesize that exposure to simulated space radiation leads to enduring alterations in the transcriptome, redox signaling and cytokine environment of cardiovascular tissue, some which have known links with reduced cardiovascular performance, aging, and increased risk of cardiovascular disease (CVD). Furthermore, we posit that simulated space radiation exposure in combination with simulated microgravity exacerbates cardiovascular deficits compared to single factor exposure. Female and male C57BL/6J mice, aged 23-24 weeks, were exposed to a single dose of 5, 15, or 50 cGy of 5-ion GCR, or sham-treated (0 cGy). Euthanasia was performed at 14 days and ~4 months post-irradiation. Hearts, aorta and blood plasma were collected shortly thereafter. RNA-sequencing of left ventricles at ~4 months post-GCR exposure revealed sex differences in the heart transcriptome with a few genes showing radiation-dependent changes in expression levels. Notably, some of the differentially expressed genes in 15 and 50 cGy GCR groups are known to play roles in the development of CVD. Analysis of protein levels of a subset of inflammatory cytokines in the heart indicated sex differences but no differences between sham and 50 cGy groups. Results also showed correlations among differentially expressed genes and a subset of inflammatory cytokines, with some correlations altered by GCR exposure. These findings suggest that GCR exposure can modify protein and gene networks linked to inflammation and CVD progression. In the aorta, telomere lengths were comparable across treatment groups sexes. Mitochondrial copy number is a biomarker for mitochondrial function with decreased copy numbers associated with cardiometabolic disease traits. Mitochondrial copy numbers of aorta also showed no sex nor dose differences. In a second study, mice underwent one week of simulated microgravity by hindlimb unloading (HU) and then exposed to a single dose of 15 cGy of 5-ion GCR. HU was conducted for an additional two weeks following GCR exposure. Single factor exposure groups (HU or GCR only) also were included in the study. Euthanasia was then performed and the same tissues were collected. Protein levels of select inflammatory cytokines in the heart showed sex-dependent differences in expression. In the aorta, telomere lengths and mitochondrial copy number also showed sex differences. In summary, our results indicate differences between sexes in biomarkers related to cardiovascular health. Exposure to 5-ion GCR or HU, alone or in combination, did not result in changes in most of the cardiovascular biomarkers that were examined. However, in the heart, simulated space radiation at doses of 15 and 50 cGy led to long-term alterations in the expression levels of a small group of genes known to be associated with the progression of CVD. The long-term transcriptomic changes resulting from exposure to simulated space radiation should be carefully investigated to mitigate adverse cardiovascular events during and after deep space missions. Our results also highlight the importance of sex-specific strategies in monitoring and maintaining cardiovascular health during and after deep space missions.

cardiovascular↗

Analyzing EOSDIS Dataset Research Outputs using Knowledge Graphs and Large Language Models

Datasets, unlike publications, can be updated over time, with each new version receiving a DOI but not always being linked to previous ones. This complicates tracking citations across a dataset’s lifecycle. We address this by integrating dataset versions and citations into a knowledge graph (KG), which helps trace dataset citations and analyze dataset usage in applied research. To categorize publications from various journals, we fine-tuned NASA IMPACT INDUS Large Language Model (LLM) on a labeled publication set, assigning publications to one of twenty applied research areas. By linking datasets to these research areas, we improved dataset searchability and discovery through these domains.

open-source↗

Reconfigurable data path processor

A reconfigurable data path processor comprises a plurality of independent processing elements. Each of the processing elements advantageously comprising an identical architecture. Each processing element comprises a plurality of data processing means for generating a potential output. Each processor is also capable of through-putting an input as a potential output with little or no processing. Each processing element comprises a conditional multiplexer having a first conditional multiplexer input, a second conditional multiplexer input and a conditional multiplexer output. A first potential output value is transmitted to the first conditional multiplexer input, and a second potential output value is transmitted to the second conditional multiplexer output. The conditional multiplexer couples either the first conditional multiplexer input or the second conditional multiplexer input to the conditional multiplexer output, according to an output control command. The output control command is generated by processing a set of arithmetic status-bits through a logical mask. The conditional multiplexer output is coupled to a first processing element output. A first set of arithmetic bits are generated according to the processing of the first processable value. A second set of arithmetic bits may be generated from a second processing operation. The selection of the arithmetic status-bits is performed by an arithmetic-status bit multiplexer selects the desired set of arithmetic status bits from among the first and second set of arithmetic status bits. The conditional multiplexer evaluates the select arithmetic status bits according to logical mask defining an algorithm for evaluating the arithmetic status bits.

Donohoe, Gregory↗

Non-blocking crossbar permutation engine with constant routing latency

The invention is embodied in an N x N crossbar for routing packets from a set of N input ports to a set of N output ports, each packet having a header identifying one of the output ports as its destination, including a plurality of individual links which carry individual packets. Each link has a link input end and a link output end, a plurality of switches. Each of the switches has at least top and bottom switch inputs connected to a corresponding pair of the link output ends and top and bottom switch outputs connected to a corresponding pair of link input ends, whereby each switch is connected to four different links. Each of the switches has an exchange state which routes packets from the top and bottom switch inputs to the bottom and top switch outputs, respectively, and a bypass state which routes packets from the top and bottom switch inputs to the top and bottom switch outputs, respectively. A plurality of individual controller devices governing respective switches for sensing from a header of a packet at each switch input for the identity of the destination output port of the packet and selecting one of the exchange and bypass states in accordance with the identity of the destination output port and with the location of the corresponding switch relative to the destination output port.

Monacos, Steve P.↗

Eddy Current Method for Fatigue Testing

Flux-focusing electromagnetic sensor using a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material. A ferrous shield isolates a high-turn pick-up coil from an excitation coil. Use of the magnetic shield produces a null voltage output across the receiving coil in presence of an unflawed sample. Redistribution of the current flow in the sample caused by the presence of flaws. eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. Maximum sensor output is obtained when positioned symmetrically above the crack. By obtaining position of maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. Accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output resulting in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip enabling the search region to be clearly defined. Under low frequency operation, material thinning due to corrosion causes incomplete shielding of the pick-up coil. Low frequency output voltage of the probe is therefore a direct indicator of thickness of the test sample. Fatigue testing a conductive material is accomplished by applying load to the material, applying current to the sensor, scanning the material with the sensor, monitoring the sensor output signal, adjusting material load based on the sensor output signal of the sensor, and adjusting position of the sensor based on its output signal.

Simpson, John W.↗

Long period pseudo random number sequence generator

A circuit for generating a sequence of pseudo random numbers, (A sub K). There is an exponentiator in GF(2 sup m) for the normal basis representation of elements in a finite field GF(2 sup m) each represented by m binary digits and having two inputs and an output from which the sequence (A sub K). Of pseudo random numbers is taken. One of the two inputs is connected to receive the outputs (E sub K) of maximal length shift register of n stages. There is a switch having a pair of inputs and an output. The switch outputs is connected to the other of the two inputs of the exponentiator. One of the switch inputs is connected for initially receiving a primitive element (A sub O) in GF(2 sup m). Finally, there is a delay circuit having an input and an output. The delay circuit output is connected to the other of the switch inputs and the delay circuit input is connected to the output of the exponentiator. Whereby after the exponentiator initially receives the primitive element (A sub O) in GF(2 sup m) through the switch, the switch can be switched to cause the exponentiator to receive as its input a delayed output A(K-1) from the exponentiator thereby generating (A sub K) continuously at the output of the exponentiator. The exponentiator in GF(2 sup m) is novel and comprises a cyclic-shift circuit; a Massey-Omura multiplier; and, a control logic circuit all operably connected together to perform the function U(sub i) = 92(sup i) (for n(sub i) = 1 or 1 (for n(subi) = 0).

Wang, Charles C.↗

Study of a High Voltage Ion Engine Power Supply

A complete laboratory breadboard version of a ion engine power converter was built and tested. This prototype operated on a line voltage of 80-120 Vdc, and provided output ratings of 1100 V at 1.8 kW, and 250 V at 20 mA. The high-voltage (HV) output voltage rating was revised from the original value of 1350 V at the beginning of the project. The LV output was designed to hold up during a 1-A surge current lasting up to 1 second. The prototype power converter included a internal housekeeping power supply which also operated from the line input. The power consumed in housekeeping was included in the overall energy budget presented for the ion engine converter. HV and LV output voltage setpoints were commanded through potentiometers. The HV converter itself reached its highest power efficiency of slightly over 93% at low line and maximum output. This would dip below 90% at high line. The no-load (rated output voltages, zero load current) power consumption of the entire system was less than 13 W. A careful loss breakdown shows that converter losses are predominately Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) conduction losses and HV rectifier snubbing losses, with the rectifier snubbing losses becoming predominant at high line. This suggests that further improvements in power efficiency could best be obtained by either developing a rectifier that was adequately protected against voltage overshoot with less snubbing, or by developing a pre-regulator to reduced the range of line voltage on the converter. The transient testing showed the converter to be fully protected against load faults, including a direct short-circuit from the HV output to the LV output terminals. Two currents sensors were used: one to directly detect any core ratcheting on the output transformer and re-initiate a soft start, and the other to directly detect a load fault and quickly shut down the converter for load protection. The finished converter has been extensively fault tested without failure. The finished converter has been packaged suitable for use as a laboratory prototype for further testing. The finished converter is readily transportable. An article on design issues for high voltage converters for ion engines is included as an attachement.

Stuart, Thomas A.↗

Traction Drives for Zero Stick-Slip Robots, and Reaction Free, Momentum Balanced Systems

Two differential (dual input, single output) drives (a roller-gear and a pure roller), and a momentum balanced (single input, dual output) drive (pure roller ) were designed, fabricated, and tested. The differential drives are each rated at 295 rad/sec (2800 rpm) input speed, 450 N-m (4,000 in-lbf) output torque. The momentum balanced drive is rated at 302 rad/sec (2880 rpm) input speed, and dual output torques of 434N-m (3840 in-lbf). The Dual Input Differential Roller-Gear Drive (DC-700) has a planetary roller-gear system with a reduction ratio (one input driving the output with the second input fixed) of 29.23: 1. The Dual Input Differential Roller Drive (DC-500) has a planetary roller system with a reduction ratio of approximately 24:1. Each of the differential drives features dual roller-gear or roller arrangements consisting of a sun, four first row planets, four second row planets, and a ring. The Momentum Balanced (Grounded Ring) Drive (DC-400) has a planetary roller system with a reduction ratio of 24:1 with both outputs counterrotating at equal speed. Its single roller cluster consists of a sun, five first and five second row planets, a roller cage or spider and a ring. Outputs are taken from both the roller cage and the ring which counterrotate. Test results reported for all three drives include angular and torque ripple (linearity and cogging), viscous and Coulomb friction, and forward and reverse power efficiency. Of the two differential drives, the Differential Roller Drive had better linearity and less cogging than did the Differential Roller-Gear Drive, but it had higher friction and lower efficiency (particularly at low power throughput levels). Use of full preloading rather than a variable preload system in the Differential Roller Drive assessed a heavy penalty in part load efficiency. Maximum measured efficiency (ratio of power out to power in) was 95% for the Differential Roller-Gear Drive and 86% for the Differential Roller Drive. The Momentum Balanced (Grounded Ring) Drive performed as expected kinematically. Reduction r-atios to the two counterrotating outputs (design nominal=24:1) were measured to be 23.98:1 and 24.12:1 at zero load.. At 25ONm (2200 in-lbf) output torque the ratio changed 2% due to roller creep. This drive was the smoothest of all three as determined from linearity and cogging tests, and maximum measured efficiency (ratio of power out to power in) was 95%. The disadvantages of full preloading as comvared to variable preload were apparent in this drive as in the Differential Roller Drive. Efficiencies at part load were low, but improved dramatically with increases in torque. These were consistent with friction measurements which indicated losses primarily from Coulomb friction. The initial preload level setting was low so roller slip was encountered at higher torques during testing.

Anderson, William J.↗

MEMS Based Acoustic Array

Embodiments of the present invention described and shown in the specification aid drawings include a combination responsive to an acoustic wave that can be utilized as a dynamic pressure sensor. In one embodiment of the present invention, the combination has a substrate having a first surface and an opposite second surface, a microphone positioned on the first surface of the substrate and having an input and a first output and a second output, wherein the input receives a biased voltage, and the microphone generates an output signal responsive to the acoustic wave between the first output and the second output. The combination further has an amplifier positioned on the first surface of the substrate and having a first input and a second input and an output, wherein the first input of the amplifier is electrically coupled to the first output of the microphone and the second input of the amplifier is electrically coupled to the second output of the microphone for receiving the output sinual from the microphone. The amplifier is spaced from the microphone with a separation smaller than 0.5 mm.

Sheplak, Mark↗

Parallel access alignment network with barrel switch implementation for d-ordered vector elements

An alignment network between N parallel data input ports and N parallel data outputs includes a first and a second barrel switch. The first barrel switch fed by the N parallel input ports shifts the N outputs thereof and in turn feeds the N-1 input data paths of the second barrel switch according to the relationship X=k.sup.y modulo N wherein x represents the output data path ordering of the first barrel switch, y represents the input data path ordering of the second barrel switch, and k equals a primitive root of the number N. The zero (0) ordered output data path of the first barrel switch is fed directly to the zero ordered output port. The N-1 output data paths of the second barrel switch are connected to the N output ports in the reverse ordering of the connections between the output data paths of the first barrel switch and the input data paths of the second barrel switch. The second switch is controlled by a value m, which in the preferred embodiment is produced at the output of a ROM addressed by the value d wherein d represents the incremental spacing or distance between data elements to be accessed from the N input ports, and m is generated therefrom according to the relationship d=k.sup.m modulo N.

Barnes, George H.↗

Cascaded resonant bridge converters

A converter for converting a low voltage direct current power source to a higher voltage, high frequency alternating current output for use in an electrical system where it is desired to use low weight cables and other circuit elements. The converter has a first stage series resonant (Schwarz) converter which converts the direct current power source to an alternating current by means of switching elements that are operated by a variable frequency voltage regulator, a transformer to step up the voltage of the alternating current, and a rectifier bridge to convert the alternating current to a direct current first stage output. The converter further has a second stage series resonant (Schwarz) converter which is connected in series to the first stage converter to receive its direct current output and convert it to a second stage high frequency alternating current output by means of switching elements that are operated by a fixed frequency oscillator. The voltage of the second stage output is controlled at a relatively constant value by controlling the first stage output voltage, which is accomplished by controlling the frequency of the first stage variable frequency voltage controller in response to second stage voltage. Fault tolerance in the event of a load short circuit is provided by making the operation of the first stage variable frequency voltage controller responsive to first and second stage current limiting devices. The second stage output is connected to a rectifier bridge whose output is connected to the input of the second stage to provide good regulation of output voltage wave form at low system loads.

Stuart, Thomas A.↗

High-Voltage Power Supply With Fast Rise and Fall Times

A special-purpose high-voltage power supply can be electronically switched on and off with fast rise and fall times, respectively. The output potential is programmable from 20 to 1,250 V. An output current of 50 A can be sustained at 1,250 V. The power supply was designed specifically for electronically shuttering a microchannel plate in an x-ray detector that must operate with exposure times as short as 1 ms. The basic design of the power supply is also adaptable to other applications in which there are requirements for rapid slewing of high voltages. The power-supply circuitry (see figure) includes a preregulator, which is used to program the output at 1/30 of the desired output potential. After the desired voltage has been set, the outputs of a pulse width modulator (PWM) are enabled and used to amplify the preregulator output potential by 30. The amplification is achieved by use of two voltage doublers with a transformer that has two primary and two secondary windings. A resistor is used to limit the current by controlling the drive voltage of two field-effect transistors (FETs) during turn-on of the PWM. A pulse transformer is used to turn on four FETs to short-circuit four output capacitors when the outputs of the PWM have been disabled. The most notable aspects of the performance of the power supply are a rise time of only 80 s and a fall time of only 60 s at a load current of 50 A or less. Another notable aspect is that the application of a 0-to-5-V square wave to a shutdown pin of the PWM causes the production of a 0-to-1,250-V square wave at the output terminals.

Bearden, Douglas B.↗