Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase Changing Materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

ISRU Pilot Excavator (IPEx) Technology Readiness Level 5 Design Overview

This paper details the mechanical and mechatronic design of the Technology Readiness Level (TRL)-5 In-Situ Resource Utilization (ISRU) Pilot Excavator (IPEx). IPEx is a robotic excavator designed for a technology demonstration of regolith mining in the lunar south -pole region. The novel design uses pairs of counter-acting excavation tools called bucket drums, that dig at the same time in opposing directions to reduce the reaction force needed, thereby enabling mining with a small, low-mass, robotic system. IPEx builds on the prior work of the Regolith Advanced Surface Systems Operations Robot (RASSOR), which is the TRL-4 implementation of this concept. The TRL-5 IPEx subsystems that are discussed in this paper include: Regolith Delivery Subsystem (RDS), Mobility Subsystem (MS), Cameras and Dust Mitigation Subsystem (CDMS), and Thermal Control Subsystem (TCS). Each subsystem is described in detail with rationale for design selections. Dust tolerance is a key feature for IPEx and this paper details a thermal control system with an actuated radiator cover and phase change material as well as camera modules with removable electrodynamic dust shields (EDS). Additional components such as actuators, wheels, and bucket drums are discussed in detail. Due to their complexity, the avionics and software subsystems will be discussed in a separate publication.

RASSOR↗

Field Study and Energy-Plus Benchmarks for Energy Saver Homes having Different Envelope Designs

An alliance to maximize energy efficiency and cost-effective residential construction (ZEBRAlliance) built and field tested four homes that are 50 percent more energy efficient than a code compliant home. The homes are unoccupied for the duration of a two-year field study, thereby eliminating the confounding issue of occupancy habits. All homes have about the same consistent and scheduled internal load. Each home showcases a unique envelope strategy: 1) structural insulated panel (SIP), 2) optimal value wall framing (OVF), 3) advanced framing featuring the benefits of insulations mixed with phase change materials (PCM), and 4) an exterior insulation and finish system (EIFS). All homes have different weather resistive barriers (WRBs) and/or air barriers to limit air and moisture infiltration. Three homes provide space conditioning and water heating via a ground loop heat exchanger, while the fourth home uses a high efficiency air-to-air heat pump and heat pump water heater. Field performance and results of EnergyPlus V7.0 benchmarks were made for roof and attics as compared to cathedral design and for wall heat flows to validate models. The moisture content of the wall sheathing is shown to prove the protecting effectiveness of WRBs. Temperature distributions through insulations in the wall and ceiling with and without PCMs are described to characterize the performance of the PCM building envelopes.

Attic↗

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

air-source heat pumps↗

A Study of the Energy-Saving Potential of Metal Roofs Incorporating Dynamic Insulation Systems

This article presents various metal roof configurations that were tested at Oak Ridge National Laboratory in Tennessee, U.S. between 2009 and 2013, and describes their potential for reducing the attic-generated space-conditioning loads. These roofs contained different combinations of phase-change material, rigid insulation, low emittance surface, and above-sheathing ventilation with standing-seam metal panels on top. These roofs were designed to be installed on existing roofs decks, or on top of asphalt shingles for retrofit construction. All the tested roofs showed the potential for substantial energy savings compared to an asphalt shingle roof, which was used as a control for comparison. The roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. The attics were built on top of a conditioned room. All attics were vented at the soffit and ridge. The test roofs and attics were instrumented with an array of thermocouples. Heat flux transducers were installed in the roof deck and attic floor (ceiling) to measure the heat flows through the roof and between the attic and conditioned space below. Temperature and heat flux data were collected during the heating, cooling and swing seasons over a three-year period. Data from previous years of testing have been published. Here, data from the latest roof configurations being tested in year three of the project are presented. All test roofs were highly effective in reducing the heat flows through the roof and ceiling, and in reducing the diurnal attic-temperature fluctuations.

Biswas, Kaushik↗

Field Testing of Nano-PCM-Enhanced Building Envelope Components in a Warm-Humid Climate

The U.S. Department of Energy Building Technologies Program s goal of developing high-performance, energy-efficient buildings will require more cost-effective, durable, energy-efficient building envelopes. Forty-eight percent of the residential enduse energy consumption is spent on space heating and air conditioning. Reducing envelope-generated heating and cooling loads through application of phase-change material (PCM) enhanced envelope components can facilitate maximizing the energy efficiency of buildings. Field testing of prototype envelope components is an important step in estimating their energy benefits. An innovative PCM (nano-PCM) was developed with PCM encapsulated with expanded graphite (interconnected) nanosheets, which is highly conducive for enhanced thermal storage and energy distribution, and is shape-stable for convenient incorporation into lightweight building components. During 2012, two test walls with cellulose cavity insulation and prototype PCM-enhanced interior wallboards were installed in a natural exposure test (NET) facility in Charleston, SC. The first test wall was divided into four sections separated by wood studs and thin layers of foam insulation. Two sections contained nano-PCMenhanced wallboards: one was a three-layer structure in which nano-PCM was sandwiched between two gypsum boards, and the other one had PCM dispersed homogeneously throughout graphite nanosheet-enhanced gypsum board. The second test wall also contained two sections with interior PCM wallboards; one contained nano-PCM dispersed homogeneously in gypsum and the other was gypsum board containing a commercial microencapsulated PCM (MEPCM) for comparison. Each test wall contained a section covered with gypsum board on the interior side that served as control or a baseline for evaluation of the PCM wallboards. The walls were instrumented with arrays of thermocouples and heat flux transducers. This paper presents the measured performance and analysis to evaluate the energy-saving potential of the nano-PCM-enhanced building components.

Biswas, Kaushik↗

TES for Residential Settings

The article discusses thermal energy storage approaches for residential buildings. This article addresses both brick bank storage and phase change material technologies. The energy savings and market potential of these thermal energy storage methods are reviewed as well.

ASHRAE↗

MEASURED SPACE CONDITIONING PERFORMANCE OFA VERTICAL-BORE GROUND SOURCE HEAT PUMP (GSHP) OVER TWELVE MONTHS UNDER SIMULATED OCCUPANCY LOADS

This paper presents monthly performance metrics of a 7.56 kW (2.16 ton) GSHP serving the space conditioning loads of a 251m2 (2700ft2) residential home with a phase change material in its envelope, and a single vertical-bore 94.5m (310 ft) ground loop. The same ground loop also serviced a ground source heat pump water heater. Envelope characteristics are discussed briefly in the context of reducing thermal losses. Data on entering water temperatures, energy extracted from the ground, energy delivered/removed, compressor electricity use, COP, GSHP run times (low and high compressor stages), and the impact of fan and pump energy consumption on efficiency are presented for each month. Both practical as well as research and development issues are discussed. The findings suggest that GSHPs represent a practical technology option to reduce source energy reduction and greenhouse emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 target of generating over 25% of heat consumed in the EU from renewable energy.

Exergy↗

Nano-based PCMs for building energy efficiency

Thermal storage using phase change materials (PCMs) is seen as a viable method for improving the energy efficiency of buildings. PCMs have been used in building applications in various forms PCM slurries in heat exchangers, macro- or microencapsulated PCMs in building envelopes, bulk PCM for modulating photovoltaic temperatures, etc. In the last decade a new class of PCMs, called nano-enhanced PCM (or nanoPCM), has been extensively investigated with the goal of improving the heat transfer and thermal storage properties of PCMs. NanoPCMs can primarily be categorized as nano-encapsulated PCMs and nanoparticle-PCM composites. The former are nano-sized capsules in which the PCM forms the core and is surrounded by a high-conductivity membrane or shell. The latter consist of PCM supported within nanostructures or nanoparticles dispersed in PCMs. This article reviews the current state of nanoPCM synthesis and characterization of their heat transfer and thermal storage properties. Further, a critical review of nanoPCM applications and their potential energy benefits is performed. Nano-enhanced PCMs exhibit higher thermal conductivities than regular PCM. However, whether the higher conductivity is desirable in all applications and if the property enhancements are worth the cost and effort needed to create nanoPCMs are questions that still need to be answered.

nano-encapsulated PCM↗

Encapsulation of high temperature molten salts

The present disclosure relates to a method of encapsulating microcapsules containing relatively high temperature phase change materials and the microcapsules so produced. The microcapsules are coated with an inorganic binder, film former and an inorganic filler. The microcapsules may include a sacrificial layer that is disposed between the particle and the coating. The microcapsules may also include an inner coating layer, sacrificial layer and outer coating layer. The microcapsules are particularly useful for thermal energy storage in connection with, e.g., heat collected from concentrating solar collectors.

25 ENERGY STORAGE↗

Pececillo

Pececillo is a proxy-app for the open source Truchas metal processing code (LA-CC-15-097). It implements many of the physics models used in Truchas: free-surface, incompressible Navier-Stokes fluid dynamics (e.g., water waves); heat transport, material phase change, view factor thermal radiation; species advection-diffusion; quasi-static, elastic/plastic solid mechanics with contact; electomagnetics (Maxwell's equations). The models are simplified versions that retain the fundamental computational complexity of the Truchas models while omitting many non-essential features and modeling capabilities. The purpose is to expose Truchas algorithms in a greatly simplified context where computer science problems related to parallel performance on advanced architectures can be more easily investigated. While Pececillo is capable of performing simulations representative of typical Truchas metal casting, welding, and additive manufacturing simulations, it lacks many of the modeling capabilites needed for real applications.

Carlson, Neil↗

Experimental Study on Portable Air-Conditioning System with Enhanced PCM Condenser

A portable personal air-conditioning system with a vapor compression cycle (VCC), electrical battery, and thermal battery is an attractive option for localized cooling as compared with stationary air-conditioning systems. A phase change material (PCM) can be used for storing waste heat from the VCC condenser, thereby acting as a thermal battery. In the PCM condenser, copper tubes are submerged in the PCM container. Due to the low thermal conductivity of pure PCM, the overall heat transfer coefficient of the PCM condenser is limited resulting in high VCC condensing pressure and thus, low VCC coefficient of performance (COP). Therefore, it is necessary to improve VCC system performances by applying heat transfer augmentation in PCM. In this work, a portable air-conditioning system with heat transfer enhanced PCM that stores heat from condenser during VCC operation and is regenerated by a thermosyphon operation is proposed. The system also includes a receiver to address the charge difference between the thermosyphon and the VCC operation. The paper experimentally studies the effects of the following three types of enhanced PCM condensers on the system performance: (1) copper mesh enhanced PCM with helically coiled copper tube branches and large refrigerant distribution headers (CMPHX), (2) graphite matrix enhanced PCM with straight copper tube branches and small headers (GMPHX1), and (3) graphite matrix enhanced PCM with straight copper tube branches and large headers (GMPHX2). Results show that this system operates properly and effectively during both VCC and PCM regeneration operations. The system can provide four hours of continuous cooling, and the PCM can be fully regenerated after 7.4 hours by thermosyphon operation. The comparisons of three PCM condensers indicate that the system with GMPHX2 performs the best with the average VCC COP of 4.7. The VCC system with CMPHX has an average COP of 4.2, and GMPHX1 has an average COP of 3.1. GMPHX2 has the best heat transfer enhancement with an overall heat transfer coefficient of 632.1 W∙m-2∙K-1, which is more than twice of GMPHX1 and five times of CMPHX. Moreover, GMPHX2 can achieve more uniform refrigerant flows and PCM temperature distributions than GMPHX1. This leads to the higher utilization ratio of PCM latent heat. CMPHX is the second best but needs larger heat transfer surface area and inner volume as well as more refrigerant charge. In conclusion, the system design with GMPHX2 is recommended due to its small refrigerant charge, high VCC COP, and the use of good heat transfer enhancement material.

Qiao, Yiyuan↗

PERFORMANCE MODELING OF A NOVEL “SMART” MAGNETIC PARTICLE-EMBEDDED PCM LAYER FOR THERMAL MANAGEMENT SYSTEMS

Developing stable and environmentally friendly phase change materials (PCM) has been an active area of research due to many applications, such as industrial energy storage system, cooling/heating applications in buildings, and thermal management for electronics equipment as well as for batteries and photovoltaic modules. However, previous studies confirmed that most PCMs suffer a serious disadvantage of low thermal conductivity. A novel design of PCM layer is investigated here for thermal management application. The novel PCM layer is comprised of a PCM and magnetic particles coated on the shell. When a magnetic field is applied in the thermal management system, due to the magnetic of the particles, PCM layer are attached to the heat source to absorb heat, which significantly improves the heat transfer between PCM and the heat source. The melting temperature of the PCM and Curie temperature of the magnetic particles are carefully selected to optimize the performance and to ensure materials compatibility. A numerical study is conducted to reveal the heat transfer and performance improvement of the PCM layer comparing to the conventional PCMs.

Zhang, Mingkan↗

Film capacitor and the method of forming the same

A film capacitor is presented. The film capacitor includes a thermally conductive support. The thermally conductive support includes a core including a first end and a second end. The thermally conductive support further includes a protrusion extending from at least one of the first end and the second end of the core, where at least one of the core and the protrusion includes a phase change material. Further, the film capacitor also includes a plurality of films disposed on at least a portion of the thermally conductive support, where the plurality of films includes a plurality of electrode films and a dielectric film. Further, the thermally conductive support for the film capacitor and a method of forming the film capacitor are also presented.

36 MATERIALS SCIENCE↗

Energy Demand Management in Buildings Using PCM-Integrated Wall

The buildings in the United States annually consume nearly 40% of total U.S. energy consumption and approximately 75% of U.S. electricity consumption. Almost half of the total U.S. energy consumption in buildings is attributed to the space conditioning through Heating, Ventilation, and Air Conditioning (HVAC) systems. Utilizing thermal energy storage in buildings, particularly integrating phase change material (PCM) in the walls, has been reported to be an effective method of managing the space heating and cooling loads. This presentation covers an in-depth discussion on the integration of a PCM to building walls, the key conditions required for effective utilization of the PCM, and effect of the PCM transition temperature and the PCM location on energy-saving potential of the PCM-integrated wall.

building↗

Cooling charge determination for a local thermal management system

A system and method for estimating the state of charge, i.e., the amount of cooling remaining, in a latent heat thermal storage module of a local environmental control system. The local environmental control system stores cooling energy at night by freezing a latent heat phase change material (PCM), and then releasing the stored cooling energy by removing heat from room air flowing through the PCM during the day. Differential temperature sensors are used measure the air temperature drop across the latent thermals storage unit and the fan voltage, which is directly related to fan air flow rate, is sampled. A controller is programmed to determine the charging state from these measurements.

Khalifa, H. Ezzat↗

Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery for Shaping the Electric Demand of Buildings

A dual-purpose underground thermal battery (DPUTB) integrates a ground heat exchanger with underground thermal energy storage. It can be installed in shallow boreholes (less than 6 m deep) and thus is less expensive than the conventional ground heat exchangers. The thermal energy storage can be used to shave or shift the electric load for meeting the thermal demands of a building. The charging and discharging performance of a lab-scale DPUTB were tested. The test results show that the DPUTB can be fully charged within 4 h and can provide 34 W cooling continuously for 2.5 h with a supply water temperature below 14°C. A small amount of phase-change material significantly increased the thermal storage capacity.

Wang, Lingshi↗

Experimental Study on Charging and Discharging Performance of a Dual-Purpose Underground Thermal Battery

A dual-purpose underground thermal battery (DPUTB) was proposed for Grid-interactive Efficient Buildings. It integrates underground thermal energy storage with a shallow-buried ground heat exchanger (less than 6 m deep). The charging and discharging performance of a lab-scale DPUTB were experimentally investigated. The test results show that the lab-scale (1:125 in volume) DPUTB can provide 34 W cooling continuously for 3.7 h with a supply water temperature below 14°C. The water temperature rise of the inner tank was slowed down during the discharging process due to the phase change of the phase change material (PCM). Thermal storage capacity was increased by 156% using the PCM that only occupied 19% volume of the inner tank. The heat lost from the inner tank was recovered in the outer tank and led to the efficiency improvement of a ground source heat pump.

Wang, Lingshi↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$15 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗