Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Monte Carlo simulations of microchannel plate detectors. I. Steady-state voltage bias results

X-ray detectors based on straight-channel microchannel plates (MCPs) are a powerful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy in the fields of laser-driven inertial confinement fusion and fast Z-pinch experiments. Understanding the behavior of microchannel plates as used in such detectors is critical to understanding the data obtained. The subject of this paper is a Monte Carlo computer code we have developed to simulate the electron cascade in a MCP under a static applied voltage. Also included in the simulation is elastic reflection of low-energy electrons from the channel wall, which is important at lower voltages. When model results were compared to measured MCP sensitivities, good agreement was found. Spatial resolution simulations of MCP-based detectors were also presented and found to agree with experimental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Sensitivity Study of the Aircraft Vortex Spacing System (AVOSS) Wake Predictor Algorithm to the Resolution of Input Meteorological Profiles

The AVOSS project demonstrated the feasibility of applying aircraft wake vortex sensing and prediction technologies to safe aircraft spacing for single runway arrivals. On average, AVOSS provided spacing recommendations that were less than the current FAA prescribed spacing rules, resulting in a potential airport efficiency gain. Subsequent efforts have included quantifying the operational specifications for future Wake Vortex Advisory Systems (WakeVAS). In support of these efforts, each of the candidate subsystems for a WakeVAS must be specified. The specifications represent a consensus between the high-level requirements and the capabilities of the candidate technologies. This report documents the beginnings of an effort to quantify the capabilities of the AVOSS Prediction Algorithm (APA). Specifically, the APA horizontal position and circulation strength output sensitivity to the resolution of its wind and turbulence inputs is examined. The results of this analysis have implications for the requirements of the meteorological sensing and prediction systems comprising a WakeVAS implementation.

Rutishauser, David K.↗

Avilamycin and evernimicin induce structural changes in rProteins uL16 and CTC that enhance the inhibition of A-site tRNA binding

Two structurally unique ribosomal antibiotics belonging to the orthosomycin family, avilamycin and evernimicin, possess activity against Enterococci, Staphylococci, and Streptococci, and other Gram-positive bacteria. Here, we describe the high-resolution crystal structures of the eubacterial large ribosomal subunit in complex with them. Their extended binding sites span the A-tRNA entrance corridor, thus inhibiting protein biosynthesis by blocking the binding site of the A-tRNA elbow, a mechanism not shared with other known antibiotics. Along with using the ribosomal components that bind and discriminate the A-tRNA—namely, ribosomal RNA (rRNA) helices H89, H91, and ribosomal proteins (rProtein) uL16—these structures revealed novel interactions with domain 2 of the CTC protein, a feature typical to various Gram-positive bacteria. Furthermore, analysis of these structures explained how single nucleotide mutations and methylations in helices H89 and H91 confer resistance to orthosomycins and revealed the sequence variations in 23S rRNA nucleotides alongside the difference in the lengths of the eukaryotic and prokaryotic α1 helix of protein uL16 that play a key role in the selectivity of those drugs. Here, the accurate interpretation of the crystal structures that could be performed beyond that recently reported in cryo-EM models provide structural insights that may be useful for the design of novel pathogen-specific antibiotics, and for improving the potency of orthosomycins. Because both drugs are extensively metabolized in vivo, their environmental toxicity is very low, thus placing them at the frontline of drugs with reduced ecological hazards.

59 BASIC BIOLOGICAL SCIENCES↗

Unraveling the Origin of Short Gamma-ray Bursts

The origin of the short (<2 s) class of gamma-ray bursts (GRBs) is finally becoming clear after decades of search. The first one localized to a few arcseconds accuracy, GRB 050509B, was found to have a highly probable association with a nearby (z = 0.225) elliptical galaxy. A second one with arcsecond localization, GRB 050709, was also associated with a low redshift (z = 0.16) galaxy. We report here the detection of short GRB 050724 with remarkable properties; in particular, it has low energy gamma-ray emission that lasts for 100 s after the main short pulse, strong early X-ray afterglow, and an unusual lightcurve that rebrightens at 3x10(exp 4) s. A position on the sky accurate to 9 arcsec was determined and provided as a GCN alert to ground-based telescopes within 80 s. A subsequent high-resolution X-ray image provided a sub-arcsec position coincident with ground-based optical and radio observations of the afterglow. Like GRB 050509B, this burst is located off-center in an elliptical galaxy. The energy output of the GRB at the host distance of z = 0.258 is 2-3 orders of magnitude less than for long bursts. The low level of star formation in such galaxies is strong evidence against a collapsar or hypernova origin like that associated with long GRBs. Based on these new data, it is highly probable that short GRBs are produced by the coalescence of orbiting neutron stars (NSs) or black holes (BHs), with some evidence for a NS-BH merger in this burst.

Barthelmy, S. D.↗

X-ray Structure and Mutational Analysis of the Atrazine Chlorohydrolase TrzN

Atrazine chlorohydrolase, TrzN (triazine hydrolase or atrazine chlorohydrolase 2), initiates bacterial metabolism of the herbicide atrazine by hydrolytic displacement of a chlorine substituent from the s-triazine ring. The present study describes crystal structures and reactivity of wild-type and active site mutant TrzN enzymes. The homodimer native enzyme structure, solved to 1.40 {angstrom} resolution, is a ({beta}{alpha}){sub 8} barrel, characteristic of members of the amidohydrolase superfamily. TrzN uniquely positions threonine 325 in place of a conserved aspartate that ligates the metal in most mononuclear amidohydrolases superfamily members. The threonine side chain oxygen atom is 3.3 {angstrom} from the zinc atom and 2.6 {angstrom} from the oxygen atom of zinc-coordinated water. Mutation of the threonine to a serine resulted in a 12-fold decrease in k{sub cat}/K{sub m}, largely due to k{sub cat}, whereas the T325D and T325E mutants had immeasurable activity. The structure and kinetics of TrzN are reminiscent of carbonic anhydrase, which uses a threonine to assist in positioning water for reaction with carbon dioxide. An isosteric substitution in the active site glutamate, E241Q, showed a large diminution in activity with ametryn, no detectable activity with atratone, and a 10-fold decrease with atrazine, when compared with wild-type TrzN. Activity with the E241Q mutant was nearly constant from pH 6.0 to 10.0, consistent with the loss of a proton-donating group. Structures for TrzN-E241Q were solved with bound ametryn and atratone to 1.93 and 1.64 {angstrom} resolution, respectively. Both structure and kinetic determinations suggest that the Glu{sup 241} side chain provides a proton to N-1 of the s-triazine substrate to facilitate nucleophilic displacement at the adjacent C-2.

59 BASIC BIOLOGICAL SCIENCES↗

Studies on the double-{beta} decay nucleus {sup 64}Zn using the (d,{sup 2}He) reaction

The (d,{sup 2}He) charge-exchange reaction on the double-{beta} decay ({beta}{beta}) nucleus {sup 64}Zn has been studied at an incident energy of 183 MeV. The two protons in the {sup 1}S{sub 0} state (indicated as {sup 2}He) were both momentum analyzed and detected simultaneously by the BBS magnetic spectrometer and its position-sensitive detector. {sup 2}He spectra with a resolution of about 115 keV (FWHM) have been obtained allowing identification of many levels in the residual nucleus {sup 64}Cu with high precision. {sup 64}Zn is one of the rare cases undergoing a {beta}{beta} decay in {beta}{sup +} direction. In the experiment presented here, Gamow-Teller (GT{sup +}) transition strengths have been extracted. Together with the GT{sup -} transition strengths from {sup 64}Ni({sup 3}He,t) data to the same intermediate nucleus {sup 64}Cu, the nuclear matrix elements of the {beta}{beta} decay of {sup 64}Zn have been evaluated. Finally, the GT{sup {+-}} distributions are compared with shell-model calculations and a critical assessment is given of the various residual interactions presently employed for the pf shell.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A fast double template convolution isocenter evaluation algorithm with subpixel accuracy

Purpose: To design a fast Winston Lutz (fWL) algorithm for accurate analysis of radiation isocenter from images without edge detection or center of mass calculations. Methods: An algorithm has been developed to implement the Winston Lutz test for mechanical/radiation isocenter agreement using an electronic portal imaging device (EPID). The algorithm detects the position of the radiation shadow of a tungsten ball within a stereotactic cone. The fWL algorithm employs a double convolution to independently find the position of the sphere and cone centers. Subpixel estimation is used to achieve high accuracy. Results of the algorithm were compared to (1) a human observer with template guidance and (2) an edge detection/center of mass (edCOM) algorithm. Testing was performed with high resolution (0.05mm/px, film) and low resolution (0.78mm/px, EPID) image sets. Results: Sphere and cone center relative positions were calculated with the fWL algorithm for high resolution test images with an accuracy of 0.002{+-}0.061 mm compared to 0.042{+-}0.294 mm for the human observer, and 0.003{+-}0.038 mm for the edCOM algorithm. The fWL algorithm required 0.01 s per image compared to 5 s for the edCOM algorithm and 20 s for the human observer. For lower resolution images the fWL algorithm localized the centers with an accuracy of 0.083{+-}0.12 mm compared to 0.03{+-}0.5514 mm for the edCOM algorithm. Conclusions: A fast (subsecond) subpixel algorithm has been developed that can accurately determine the center locations of the ball and cone in Winston Lutz test images without edge detection or COM calculations.

60 APPLIED LIFE SCIENCES↗

Identifying Important Ions and Positions in Mass Spectrometry Imaging Data Using CUR Matrix Decompositions

Mass spectrometry imaging enables label-free, high-resolution spatial mapping of the chemical composition of complex, biological samples. Typical experiments require selecting ions and/or positions from the images: ions for fragmentation studies to identify keystone compounds and positions for follow up validation measurements using microdissection or other orthogonal techniques. Unfortunately, with modern imaging machines, these must be selected from an overwhelming amount of raw data. Existing techniques to reduce the volume of data, the most popular of which are principle component analysis and non-negative matrix factorization, have the disadvantage that they return difficult-to-interpret linear combinations of actual data elements. In this work, we show that CX and CUR matrix decompositions can be used directly to address this selection need. CX and CUR matrix decompositions use empirical statistical leverage scores of the input data to provide provably good low-rank approximations of the measured data that are expressed in terms of actual ions and actual positions, as opposed to difficult-to-interpret eigenions and eigenpositions. We show that this leads to effective prioritization of information for both ions and positions. In particular, important ions can be found either by using the leverage scores as a ranking function and using a deterministic greedy selection algorithm or by using the leverage scores as an importance sampling distribution and using a random sampling algorithm; however, selection of important positions from the original matrix performed significantly better when they were chosen with the random sampling algorithm. Also, we show that 20 ions or 40 locations can be used to reconstruct the original matrix to a tolerance of 17% error for a widely studied image of brain lipids; and we provide a scalable implementation of this method that is applicable for analysis of the raw data where there are often more than a million rows and/or columns, which is larger than SVD-based low-rank approximation methods can handle. Lastly, these results introduce the concept of CX/CUR matrix factorizations to mass spectrometry imaging, describing their utility and illustrating principled algorithmic approaches to deal with the overwhelming amount of data generated by modern mass spectrometry imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characteristics of the 2 m long scintillation counters measured by detecting 90 MeV protons

The characteristics of scintillation counters measured in a 90-MeV proton beam have been presented. Two-meter long scintillators BC-404 and BC-408, which were viewed from both ends with photoelectron multipliers R1828-01 (PMT) have been used. Both the amplitude and time distributions of the PMT signals are well described by the Gaussian function. It turned out that the amplitude resolution σ(А)/А weakly depends on the type of scintillator and the proton position along the counter, and lies in the interval between 4 and 5%. The best time resolution σ(T) is about 50 ps near the counter ends and 63 ps at the center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fuzzy correlations of gamma-ray bursts

The origin of gamma-ray bursts is not known, both in the sense of the nature of the source emitting the radiation and literally, the position of the burst on the sky. Lacking unambiguously identified counterparts in any wavelength band studied to date, statistical approaches are required to determine the burster distance scale. Angular correlation analysis is one of the most powerful tools in this regard. However, poor detector resolution gives large localization errors, effectively beam smearing the positions. The resulting fuzzy angular correlation function is investigated and the generic isotropization that smearing induces on any intrinsic clustering is discussed. In particular, the extent to which gamma-ray burst observations by the BATSE detector aboard the Gamma-Ray Observatory might recover an intrinsic source correlation is investigated.

Hartmann, Dieter H.↗

Materials News: Interfacial chemistry and atomic arrangement of ZrO{sub 2} − La{sub 2/3}Sr{sub 1/3}MnO{sub 3} pillar-matrix structures

We studied ZrO{sub 2} − La{sub 2/3}Sr{sub 1/3}MnO{sub 3} pillar–matrix thin films which were found to show anomalous magnetic and electron transport properties. With the application of an aberration-corrected transmission electron microscope, interfacial chemistry, and atomic-arrangement of the system, especially of the pillar–matrix interface were revealed at atomic resolution. Minor amounts of Zr were found to occupy Mn positions within the matrix. The Zr concentration reaches a minimum near the pillar–matrix interface accompanied by oxygen vacancies. La and Mn diffusion into the pillar was revealed at atomic resolution and a concomitant change of the Mn valence state was observed.

36 MATERIALS SCIENCE↗

Combination of a reflectometer and a nonmagnetic waveguide for experiments with polarized neutron microbeams

Neutron waveguides are three-layer thin-film structures which transform part of a collimated (with an angular divergence of 0.01 Degree-Sign ) and relatively wide (0.1 mm) incident neutron beam into a narrow (0.1 {mu}m wide) and divergent (0.1 Degree-Sign ) beam at the output. This submicron beam (which cannot be obtained using conventional focusing elements) is promising for studying nanostructures. We propose a combination of a polarized-neutron reflectometer and a nonmagnetic (independent of the neutron spin) waveguide for experiments employing polarized neutron beams with a submicron spatial resolution. This scheme can be applied, for example, for position-sensitive studies of magnetic nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Position/Structure Stability of Four ICRF2 Sources

Four compact radio sources in the International Celestial Reference Frame (ICRF2) catalog were observed using phase referencing with the VLBA at 43, 23, and 8.6-GHz, and with VERA at 23-GHz over a one-year period. The goal was to determine the stability of the radio cores and to assess structure effects associated with positions in the ICRF2. Conclusions are: (1) 43-GHz VLBI high-resolution observations are often needed to determine the location of the radio core. (2) Over the observing period, the relative positions among the four radio cores were constant to 0.02 mas, suggesting that once the true radio core is identified, it remains stationary in the sky to this accuracy. (3) The emission in 0556+238, one of the four sources investigated and one of the 295 ICRF2 defining sources, was dominated by a strong component near the core and moved 0.1 mas during the year. (4) Comparison of the VLBA images at 43, 23, and 8.6-GHz with the ICRF2 positions suggests that the 8-GHz structure is often dominated by a bright non-core component. The measured ICRF2 position can be displaced more than 0.5 mas from the radio core and partake in the motion of the bright jet component.

Fomalont, Ed↗

Practical formulation of a positively conservative scheme

Approximate Riemann solvers have been highly successful for computing the Euler/Navier-Stokes equations, but linearized Riemann solvers are known to fail occasionally by predicting non-physical states with negative density or internal energy. Positively conservative schemes, in contrast, guarantee physical solutions from realistic input. The Harten-Lax-van Leer-Einfeldt (HLLE) scheme is a typical example of a positively conservative scheme. However, the HLLE scheme is highly dissipative at contact discontinuities and shear layers and thus it is not applicable to practicle simulations. An existing modification to the HLLE scheme, known as HLLEM, enhances the resolution to that of the Roe scheme. However, this modification violates the positivity of density and internal energy. Precise derivation of the modification yields a quatratic inequality and thus requires a case-by-case treatment. This Note describes a new, modified HLLE scheme that satisfies the positively conservative condition approximately. Sample computationa are included to demonstrate the resolution and the robustness of the scheme.

Obayashi, Shigeru↗

Structure analysis of the telomere resolvase from the Lyme disease spirochete Borrelia garinii reveals functional divergence of its C-terminal domain

Borrelia spirochetes are the causative agents of Lyme disease and relapsing fever, two of the most common tick-borne illnesses. A characteristic feature of these spirochetes is their highly segmented genomes which consists of a linear chromosome and a mixture of up to approximately 24 linear and circular extrachromosomal plasmids. The complexity of this genomic arrangement requires multiple strategies for efficient replication and partitioning during cell division, including the generation of hairpin ends found on linear replicons mediated by the essential enzyme ResT, a telomere resolvase. Using an integrative structural biology approach employing advanced modelling, circular dichroism, X-ray crystallography and small-angle X-ray scattering, we have generated high resolution structural data on ResT from B. garinii. Our data provides the first high-resolution structures of ResT from Borrelia spirochetes and revealed active site positioning in the catalytic domain. We also demonstrate that the C-terminal domain of ResT is required for both transesterification steps of telomere resolution, and is a requirement for DNA binding, distinguishing ResT from other telomere resolvases from phage and bacteria. These results advance our understanding of the molecular function of this essential enzyme involved in genome maintenance in Borrelia pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Position Stability Monitoring of THEthe LCLS Undulator Quadrupoles

X-ray FELs demand that the positions of undulator components be stable to less than 1 {mu}m per day. Simultaneously, the undulator length increases significantly in order to saturate at x-ray wavelengths. To minimize the impact of the outside environment, the Linac Coherent Light Source (LCLS) undulator is placed underground, but reliable data about ground motion inside such a tunnel was not available in the required stability range during the planning phase. Therefore, a new position monitor system had been developed and installed with the LCLS undulator. This system is capable of measuring x, y, roll, pitch and yaw of each of the 33 undulator quadrupoles with respect to stretched wires. Instrument resolution is about 10 nm and instrument drift is negligible. Position data of individual quadrupoles can be correlated along the entire 132-m long undulator. The system has been under continuous operation since 2009. This report describes long term experiences with the running system and the observed positional stability of the undulator quadrupoles.

43 PARTICLE ACCELERATORS↗

MALT90 Kinematic Distances to Dense Molecular Clumps

Using molecular-line data from the Millimetre Astronomy Legacy Team 90 GHz Survey (MALT90), we have estimated kinematic distances to 1905 molecular clumps identified in the ATLASGAL 870 μ m continuum survey over the longitude range 295° < l < 350°. The clump velocities were determined using a flux-weighted average of the velocities obtained from Gaussian fits to the HCO{sup +}, HNC, and N{sub 2}H{sup +} (1–0) transitions. The near/far kinematic distance ambiguity was addressed by searching for the presence or absence of absorption or self-absorption features in 21 cm atomic hydrogen spectra from the Southern Galactic Plane Survey. Our algorithm provides an estimation of the reliability of the ambiguity resolution. The Galactic distribution of the clumps indicates positions where the clumps are bunched together, and these locations probably trace the locations of spiral arms. Several clumps fall at the predicted location of the far side of the Scutum–Centaurus arm. Moreover, a number of clumps with positive radial velocities are unambiguously located on the far side of the Milky Way at galactocentric radii beyond the solar circle. The measurement of these kinematic distances, in combination with continuum or molecular-line data, now enables the determination of fundamental parameters such as mass, size, and luminosity for each clump.

79 ASTRONOMY AND ASTROPHYSICS↗