Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

A GPU based high-resolution multilevel biomechanical head and neck model for validating deformable image registration

Purpose: Validating the usage of deformable image registration (DIR) for daily patient positioning is critical for adaptive radiotherapy (RT) applications pertaining to head and neck (HN) radiotherapy. The authors present a methodology for generating biomechanically realistic ground-truth data for validating DIR algorithms for HN anatomy by (a) developing a high-resolution deformable biomechanical HN model from a planning CT, (b) simulating deformations for a range of interfraction posture changes and physiological regression, and (c) generating subsequent CT images representing the deformed anatomy. Methods: The biomechanical model was developed using HN kVCT datasets and the corresponding structure contours. The voxels inside a given 3D contour boundary were clustered using a graphics processing unit (GPU) based algorithm that accounted for inconsistencies and gaps in the boundary to form a volumetric structure. While the bony anatomy was modeled as rigid body, the muscle and soft tissue structures were modeled as mass–spring-damper models with elastic material properties that corresponded to the underlying contoured anatomies. Within a given muscle structure, the voxels were classified using a uniform grid and a normalized mass was assigned to each voxel based on its Hounsfield number. The soft tissue deformation for a given skeletal actuation was performed using an implicit Euler integration with each iteration split into two substeps: one for the muscle structures and the other for the remaining soft tissues. Posture changes were simulated by articulating the skeletal structure and enabling the soft structures to deform accordingly. Physiological changes representing tumor regression were simulated by reducing the target volume and enabling the surrounding soft structures to deform accordingly. Finally, the authors also discuss a new approach to generate kVCT images representing the deformed anatomy that accounts for gaps and antialiasing artifacts that may be caused by the biomechanical deformation process. Accuracy and stability of the model response were validated using ground-truth simulations representing soft tissue behavior under local and global deformations. Numerical accuracy of the HN deformations was analyzed by applying nonrigid skeletal transformations acquired from interfraction kVCT images to the model’s skeletal structures and comparing the subsequent soft tissue deformations of the model with the clinical anatomy. Results: The GPU based framework enabled the model deformation to be performed at 60 frames/s, facilitating simulations of posture changes and physiological regressions at interactive speeds. The soft tissue response was accurate with a R{sup 2} value of >0.98 when compared to ground-truth global and local force deformation analysis. The deformation of the HN anatomy by the model agreed with the clinically observed deformations with an average correlation coefficient of 0.956. For a clinically relevant range of posture and physiological changes, the model deformations stabilized with an uncertainty of less than 0.01 mm. Conclusions: Documenting dose delivery for HN radiotherapy is essential accounting for posture and physiological changes. The biomechanical model discussed in this paper was able to deform in real-time, allowing interactive simulations and visualization of such changes. The model would allow patient specific validations of the DIR method and has the potential to be a significant aid in adaptive radiotherapy techniques.

60 APPLIED LIFE SCIENCES↗

Special Nuclear Material Characterization Using Digital 3-D Position Sensitive CdZnTe Detectors and High Purity Germanium Spectrometers

Special nuclear material (SNM) monitoring often requires high resolution gamma-ray spectroscopy for material characterization. Portable systems and rapid deployment are also highly valued for some applications. Deployable gamma-ray imaging spectrometers using pixelated CdZnTe semiconductor detectors have become commercially available within the past three years to meet these requirements. CdZnTe systems have demonstrated room-temperature energy resolutions below 0.5% FWHM at 662 keV using single pixel events and below 0.7% FWHM at 662 keV using all events. The systems are able to go from storage to measurement in less than two minutes. Special nuclear materials were measured at the Y-12 National Security Complex and at the Device Assembly Facility at the Nevada National Security Site. The use of a CdZnTe system to measure uranium enrichment was demonstrated and uranium spectral features were compared to a commercially available high purity germanium (HPGe) spectrometer. The use of passive gamma ray spectroscopy techniques to estimate plutonium grade using CdZnTe detectors was demonstrated for the first time.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Diffractive Imaging of Coherent Nuclear Motion in Isolated Molecules

Observing the motion of the nuclear wave packets during a molecular reaction, in both space and time, is crucial for understanding and controlling the outcome of photoinduced chemical reactions. We have imaged the motion of a vibrational wave packet in isolated iodine molecules using ultrafast electron diffraction with relativistic electrons. The time-varying interatomic distance was measured with a precision 0.07 Å and temporal resolution of 230 fs full width at half maximum. The method is not only sensitive to the position but also the shape of the nuclear wave packet.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

19‐1: Invited Paper: Atom Probe Tomography for Understanding OLED Morphology

We have recently demonstrated that atom probe tomography (APT) can be applied to Organic Light Emitting Diode (OLED) materials. APT can measure the mass and position of molecules in a film with sub‐Dalton and sub‐nm resolutions, allowing for morphology measurements of OLED systems. We will discuss the technique and key results in emissive guest‐host systems.

Zimmerman, Jeramy D.↗

Positivity-preserving high order well-balanced discontinuous Galerkin methods for the shallow water equations

Shallow water equations with a non-flat bottom topography have been widely used to model flows in rivers and coastal areas. An important difficulty arising in these simulations is the appearance of dry areas where no water is present, as standard numerical methods may fail in the presence of these areas. These equations also have still water steady state solutions in which the flux gradients are nonzero but exactly balanced by the source term. In this paper we propose a high order discontinuous Galerkin method which can maintain the still water steady state exactly, and at the same time can preserve the non-negativity of the water height without loss of mass conservation. A simple positivity-preserving limiter, valid under suitable CFL condition, will be introduced in one dimension and then extended to two dimensions with rectangular meshes. Numerical tests are performed to verify the positivity-preserving property, well-balanced property, high order accuracy, and good resolution for smooth and discontinuous solutions.

54 ENVIRONMENTAL SCIENCES↗

UrbanPop: A spatial microsimulation framework for exploring demographic influences on human dynamics

Ensuring the social equity of planning measures in social systems requires an understanding of human dynamics, particularly how individual relationships, activities, and interactions intersect with individual needs. Spatial microsimulation models (SMSMs) support planning for human security goals by representing human dynamics through realistic, georeferenced synthetic populations, that a) provide a complete representation of social systems while b) also protecting individual privacy. In this paper, we present UrbanPop, an open and reproducible SMSM framework for analysis of human dynamics with high spatial, temporal, and demographic resolution. UrbanPop creates synthetic populations of demographically detailed worker and student agents, positioning them first at probable nighttime locations (home), then moving them to probable daytime locations (work/school). Summary aggregations of these populations match the granular detail available at the census block group level in the American Community Survey Summary File (SF), providing realistic approximations of the actual population. UrbanPop users can select particular demographic traits important in their application, resulting in a highly tailored agent population. We first lay out UrbanPop's baseline methodology, including population synthesis, activity modeling, and diagnostics, then demonstrate these capabilities by developing case studies of shifting population distributions and high-risk populations in Knox County, TN during the global COVID-19 pandemic.

60 APPLIED LIFE SCIENCES↗

Intrinsic Li Distribution in Layered Transition-Metal Oxides Using Low-Dose Scanning Transmission Electron Microscopy and Spectroscopy

Understanding Li distribution in layered lithium transition-metal oxide (LiTMO) cathodes in Li-ion batteries has been a major challenge at the atomic scale and nanoscale. Li is extremely difficult to study by transmission electron microscopy (TEM) because the high-energy electrons impart significant energy and cause massive migration. Here, we directly map the intrinsic spatial distribution and bonding of Li in LiNiO 2 -layered cathode materials using low-dose and low-loss electron energy loss spectroscopy (EELS). EELS spectra of the Li–K edge are measured simultaneously with O–K and Ni–L, M 3,2 edges from layered, cation-mixed, and rock-salt phases and directly matched with atomic-resolution scanning TEM images to correlate the changes in peak intensities and positions to the stoichiometry changes with continual loss of Li and O. Changes in the Li content in the LiNiO 2 particles as a function of electron beam dose are studied by sequential Li spectroscopic mapping. We show that the “intrinsic” Li distribution can be observed using a total dose of less than ~1.5 × 10 8 e – nm –2 at an accelerating voltage of 80 kV. The method of nanoscale mapping of Li distribution introduced in this study is applicable to high-Ni LiTMO cathode materials (>89% of Ni) as well as LiNiO 2 . Further study on the extra peaks of the Li–K edge reveals that the peak at ~59 eV is from the Li ions intercalated in between NiO 2 layers barely interacting with each other with less Li K shell electrons pulled to the L shell electrons in NiO 2 . Furthermore, the results shown here provide improved low-loss TEM characterization approaches that can be used to understand the intrinsic fundamental behaviors in Li-ion batteries.

25 ENERGY STORAGE↗

An Atom-Precise Approach to Damp First-Order Phase Transitions and Its Implications for Neuromorphic Signal Processing

Neuromorphic computing inspired by mammalian intelligence aims to emulate the nonlinear dynamics of biological neurons and synapses to achieve fast, low-energy, and highly efficient information processing. Brain-inspired computing relies on the design and discovery of materials exhibiting nonlinear current–voltage profiles, frequently underpinned by electronic state transitions, to achieve spiking neurons and dynamically tunable synapses. A signature challenge in the design of artificial neurons is controlling the steepness of first-order transitions in active elements, as abrupt transitions are at risk of driving unstable voltage and temperature oscillations, which result in catastrophic device failure. A critical knowledge gap is the lack of structure–function correlations mapping the composition and atomistic structure of crystalline solids to nonlinear dynamical response characteristics. Here, we address the key question of how modification of atomistic structure correlates with alteration of neuron-like functionality. Constructing oscillator circuits from millimeter-scale single crystals enables high-resolution atomic structure solutions, which we use to demonstrate that the selective positioning of Pb cations modifies charge ordering along a one-dimensional CuxV2O5 framework even at low insertion stoichiometries, thereby providing an atom-precise design parameter for damping first-order transitions. We use temperature-variant X-ray diffraction and X-ray spectroscopy to elucidate the suppression of Cu-ion shuttling based on the precise positioning of Pb ions in seven-coordinated tunnel interstitial sites as the mechanistic basis for transition broadening, thus bridging a critical gap between statistical mechanics and quantum chemical descriptions of phase transitions. Such mechanistic understanding thus paves the way to site-selective modification strategies for modulating the sharpness of first-order transitions, with an exemplary demonstration here in tuning neuronal signal processing.

Crystal structure↗

Development of Isotope Analysis Based on Laser Induced Fluorescence

We have proposed Laser Induced Fluorescence analysis using Doppler Shift of laser ablated atoms for Isotope Analysis (LIF-DS-IA). This isotope analysis is expected to have a small mass discrimination effect because the detection target is fluorescence photons instead of ions, which distort the measured isotope ratio by the space charge effect. We demonstrate this technique to be feasible through the model calculations. We experimentally confirmed the fundamental behavior in LIF-DS-IA that the shift in the irradiating laser frequency corresponds to that of peak position in the time domain LIF spectra. The reason of poor mass resolution in the present system was considered to be inadequate definition in the field of view of the fluorescence detector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Signatures of correlated excitonic dynamics in two-dimensional spectroscopy of the Fenna-Matthew-Olson photosynthetic complex

Long-lived excitonic coherence in photosynthetic proteins has become an exciting area of research because it may provide design principles for enhancing the efficiency of energy transfer in a broad range of materials. In this publication, we provide new evidence that long-lived excitonic coherence in the Fenna-Mathew-Olson pigment-protein (FMO) complex is consistent with the assumption of cross correlation in the site basis, indicating that each site shares bath fluctuations. We analyze the structure and character of the beating crosspeak between the two lowest energy excitons in two-dimensional (2D) electronic spectra of the FMO Complex. To isolate this dynamic signature, we use the two-dimensional linear prediction Z-transform as a platform for filtering coherent beating signatures within 2D spectra. By separating signals into components in frequency and decay rate representations, we are able to improve resolution and isolate specific coherences. This strategy permits analysis of the shape, position, character, and phase of these features. Simulations of the crosspeak between excitons 1 and 2 in FMO under different regimes of cross correlation verify that statistically independent site fluctuations do not account for the elongation and persistence of the dynamic crosspeak. To reproduce the experimental results, we invoke near complete correlation in the fluctuations experienced by the sites associated with excitons 1 and 2. This model contradicts ab initio quantum mechanic/molecular mechanics simulations that observe no correlation between the energies of individual sites. This contradiction suggests that a new physical model for long-lived coherence may be necessary. The data presented here details experimental results that must be reproduced for a physical model of quantum coherence in photosynthetic energy transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contributed Review: Experimental characterization of inverse piezoelectric strain in GaN HEMTs via micro-Raman spectroscopy

Micro-Raman thermography is one of the most popular techniques for measuring local temperature rise in gallium nitride (GaN) high electron mobility transistors with high spatial and temporal resolution. However, accurate temperature measurements based on changes in the Stokes peak positions of the GaN epitaxial layers require properly accounting for the stress and/or strain induced by the inverse piezoelectric effect. It is common practice to use the pinched OFF state as the unpowered reference for temperature measurements because the vertical electric field in the GaN buffer that induces inverse piezoelectric stress/strain is relatively independent of the gate bias. Although this approach has yielded temperature measurements that agree with those derived from the Stokes/anti-Stokes ratio and thermal models, there has been significant difficulty in quantifying the mechanical state of the GaN buffer in the pinched OFF state from changes in the Raman spectra. In this paper, we review the experimental technique of micro-Raman thermography and derive expressions for the detailed dependence of the Raman peak positions on strain, stress, and electric field components in wurtzite GaN. We also use a combination of semiconductor device modeling and electro-mechanical modeling to predict the stress and strain induced by the inverse piezoelectric effect. Based on the insights gained from our electro-mechanical model and the best values of material properties in the literature, we analyze changes in the E{sub 2} high and A{sub 1} (LO) Raman peaks and demonstrate that there are major quantitative discrepancies between measured and modeled values of inverse piezoelectric stress and strain. We examine many of the hypotheses offered in the literature for these discrepancies but conclude that none of them satisfactorily resolves these discrepancies. Further research is needed to determine whether the electric field components could be affecting the phonon frequencies apart from the inverse piezoelectric effect in wurtzite GaN, which has been predicted theoretically in zinc blende gallium arsenide (GaAs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MULTIPLICITY OF THE PROTOSTAR SERPENS SMM 1 REVEALED BY MILLIMETER IMAGING

The Serpens SMM 1 region was observed in the 6.9 mm continuum with an angular resolution of about 0.''6. Two sources were found to have steep positive spectra suggesting emission from dust. The stronger one, SMM 1a, is the driving source of the bipolar jet previously known, and the mass of the dense molecular gas traced by the millimeter continuum is about 8 M{sub sun}. The newly found source, SMM 1b, positionally coincides with the brightest mid-IR source in this region, which implies that SMM 1b is yet another young stellar object. SMM 1b seems to be less deeply embedded than SMM 1a. SMM 1 is probably a protobinary system with a projected separation of 500 AU.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MAGNETIC FIELD STRUCTURES AND TURBULENT COMPONENTS IN THE STAR-FORMING MOLECULAR CLOUDS OMC-2 AND OMC-3

The SCUBA polarized 850 {mu}m thermal emission data of the OMC-2 region in Orion A are added to and homogeneously reduced with data already available in the OMC-3 region. The data set shows that OMC-2 is a region generally less polarized than OMC-3. Where coincident, most of the 850 {mu}m polarization pattern is similar to that measured in 350 {mu}m polarization data. Only 850 {mu}m polarimetry data have been obtained in and around MMS7, FIR1 and FIR2, and in the region south of FIR6. A realignment of the polarization vectors with the filament can be seen near FIR1 in the region south of OMC-3. An analysis shows that the energy injected by CO outflows and H{sub 2} jets associated with OMC-2 and OMC-3 does not appear to alter the polarization patterns at a scale of the 14'' resolution beam. A second-order structure function analysis of the polarization position angles shows that OMC-2 is a more turbulent region than OMC-3. OMC-3 appears to be a clear case of a magnetically dominated region with respect to the turbulence. However, for OMC-2 it is not clear that this is the case. A more in-depth analysis of five regions displayed along OMC-2/3 indicates a decrease of the mean polarization degree and an increase of the turbulent angular dispersion from north to south. A statistical analysis suggests the presence of two depolarization regimes in our maps: one regime including the effects of the cores, the other one excluding it.

79 ASTRONOMY AND ASTROPHYSICS↗

STRUCTURE AND DYNAMICS OF THE 2012 NOVEMBER 13/14 ECLIPSE WHITE-LIGHT CORONA

Continuing our series of observations of coronal motion and dynamics over the solar-activity cycle, we observed from sites in Queensland, Australia, during the 2012 November 13 (UT)/14 (local time) total solar eclipse. The corona took the low-ellipticity shape typical of solar maximum (flattening index ε = 0.01), a change from the composite coronal images we observed and analyzed in this journal and elsewhere for the 2006 and 2008-2010 eclipses. After crossing the northeast Australian coast, the path of totality was over the ocean, so further totality was seen only by shipborne observers. Our results include velocities of a coronal mass ejection (CME; during the 36 minutes of passage from the Queensland coast to a ship north of New Zealand, we measured 413 km s{sup –1}) and we analyze its dynamics. We discuss the shapes and positions of several types of coronal features seen on our higher-resolution composite Queensland coronal images, including many helmet streamers, very faint bright and dark loops at the bases of helmet streamers, voids, and radially oriented thin streamers. We compare our eclipse observations with models of the magnetic field, confirming the validity of the predictions, and relate the eclipse phenomenology seen with the near-simultaneous images from NASA's Solar Dynamics Observatory (SDO/AIA), NASA's Extreme Ultraviolet Imager on Solar Terrestrial Relations Observatory, ESA/Royal Observatory of Belgium's Sun Watcher with Active Pixels and Image Processing (SWAP) on PROBA2, and Naval Research Laboratory's Large Angle and Spectrometric Coronagraph Experiment on ESA's Solar and Heliospheric Observatory. For example, the southeastern CME is related to the solar flare whose origin we trace with a SWAP series of images.

79 ASTRONOMY AND ASTROPHYSICS↗

The Effects of Radiation and Emitted Light Transport on the Positional Response of 11 cm × 42.5 cm × 5.5 cm NaI(Tl) Detectors

Experiments were performed with 30 11 cm x 42.5 x cm 5.5 cm NaI(Tl) detectors to better understand their positional response. Spectra were collected using 0.02 to 0.15 MBq point sources of 241 Am, 137 Cs, 60 Co, and 133 Ba positioned on lines parallel and perpendicular to the long axis of the crystal along both the narrow and wide detector faces as well as at different distances from them. A greater density of positions was sampled at the ends of the detector, and repeated measurements were made to examine potential gain drifts during the experiment. Spectroscopic peak counts, spectroscopic pulse heights, and net counts were analyzed. Empirical equations were fit to the aforementioned data for each specific source energy as a function of source position. In addition, a Monte Carlo radiation transport code was used to simulate the expected positionally variable response based solely upon radiation absorption. The simulated radiation transport efficiency functions were compared to the experimental data. The effects of the geometric radiation efficiency, the attenuation and scattering of emitted light within the scintillation crystal, and combined effects such as non-uniformity of the photomultiplier tube photocathode response and crystal irregularities were then distinguished. Functions describing each effect were derived. The results suggest potential new corrections to data obtained with large scintillation detectors as well as a novel approach to partial positional gamma-ray detection with minimal collimation, given that the energy resolution is within reason for particular photopeaks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗