Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

FastProNGS: fast preprocessing of next-generation sequencing reads

Background Next-generation sequencing technology is developing rapidly and the vast amount of data that is generated needs to be preprocessed for downstream analyses. Yet, until now, software that can efficiently make all the quality assessments and filtration of raw data is still lacking. Results We developed FastProNGS to integrate the quality control process with automatic adapter removal. Parallel processing was implemented to speed up the process by allocating multiple threads. Compared with similar up-to-date preprocessing tools, FastProNGS is by far the fastest. Read information before and after filtration can be output in plain-text, JSON, or HTML formats with user-friendly visualization. Conclusions FastProNGS is a rapid, standardized, and user-friendly tool for preprocessing next-generation sequencing data within minutes. It is an all-in-one software that is convenient for bulk data analysis. It is additionally very flexible and can implement different functions using different user-set parameter combinations.

97 MATHEMATICS AND COMPUTING↗

An optimal merging technique for high-resolution precipitation products

Precipitation products are currently available from various sources at higher spatial and temporal resolution than any time in the past. Each of the precipitation products has its strengths and weaknesses in availability, accuracy, resolution, retrieval techniques and quality control. By merging the precipitation data obtained from multiple sources, one can improve its information content by minimizing these issues. However, precipitation data merging poses challenges of scale-mismatch, and accurate error and bias assessment. In this paper we present Optimal Merging of Precipitation (OMP), a new method to merge precipitation data from multiple sources that are of different spatial and temporal resolutions and accuracies. This method is a combination of scale conversion and merging weight optimization, involving performance-tracing based on Bayesian statistics and trend-analysis, which yields merging weights for each precipitation data source. The weights are optimized at multiple scales to facilitate multiscale merging and better precipitation downscaling. Precipitation data used in the experiment include products from the 12-km resolution North American Land Data Assimilation (NLDAS) system, the 8-km resolution CMORPH and the 4-km resolution National Stage-IV QPE. The test cases demonstrate that the OMP method is capable of identifying a better data source and allocating a higher priority for them in the merging procedure, dynamically over the region and time period. This method is also effective in filtering out poor quality data introduced into the merging process.

54 ENVIRONMENTAL SCIENCES↗

USP14 inhibits ER-associated degradation via interaction with IRE1{alpha}

Accumulation of unfolded proteins within the endoplasmic reticulum (ER) lumen induces ER stress. Eukaryotic cells possess the ER quality control systems, the unfolded protein response (UPR), to adapt to ER stress. IRE1{alpha} is one of the ER stress receptors and mediates the UPR. Here, we identified ubiquitin specific protease (USP) 14 as a binding partner of IRE1{alpha}. USP14 interacted with the cytoplasmic region of IRE1{alpha}, and the endogenous interaction between USP14 and IRE1{alpha} was inhibited by ER stress. Overexpression of USP14 inhibited the ER-associated degradation (ERAD) pathway, and USP14 depletion by small interfering RNA effectively activated ERAD. These findings suggest that USP14 is a novel player in the UPR by serving as a physiological inhibitor of ERAD under the non-stressed condition.

60 APPLIED LIFE SCIENCES↗

Scanning Cloud Radar Observations at Azores: Preliminary 3D Cloud Products

The deployment of the Scanning W-Band ARM Cloud Radar (SWACR) during the AMF campaign at Azores signals the first deployment of an ARM Facility-owned scanning cloud radar and offers a prelude for the type of 3D cloud observations that ARM will have the capability to provide at all the ARM Climate Research Facility sites by the end of 2010. The primary objective of the deployment of Scanning ARM Cloud Radars (SACRs) at the ARM Facility sites is to map continuously (operationally) the 3D structure of clouds and shallow precipitation and to provide 3D microphysical and dynamical retrievals for cloud life cycle and cloud-scale process studies. This is a challenging task, never attempted before, and requires significant research and development efforts in order to understand the radar's capabilities and limitations. At the same time, we need to look beyond the radar meteorology aspects of the challenge and ensure that the hardware and software capabilities of the new systems are utilized for the development of 3D data products that address the scientific needs of the new Atmospheric System Research (ASR) program. The SWACR observations at Azores provide a first look at such observations and the challenges associated with their analysis and interpretation. The set of scan strategies applied during the SWACR deployment and their merit is discussed. The scan strategies were adjusted for the detection of marine stratocumulus and shallow cumulus that were frequently observed at the Azores deployment. Quality control procedures for the radar reflectivity and Doppler products are presented. Finally, preliminary 3D-Active Remote Sensing of Cloud Locations (3D-ARSCL) products on a regular grid will be presented, and the challenges associated with their development discussed. In addition to data from the Azores deployment, limited data from the follow-up deployment of the SWACR at the ARM SGP site will be presented. This effort provides a blueprint for the effort required for the development of 3D cloud products from all new SACRs that the program will deploy at all fixed and mobile sites by the end of 2010.

54 ENVIRONMENTAL SCIENCES↗

Radiosynthesis and Biodistribution of {sup 99m}Tc-Metronidazole as an Escherichia coli Infection Imaging Radiopharmaceutical

Bacterial infection poses life-threatening challenge to humanity and stimulates to the researchers for developing better diagnostic and therapeutic agents complying with existing theranostic techniques. Nuclear medicine technique helps to visualize hard-to-diagnose deep-seated bacterial infections using radionuclide-labeled tracer agents. Metronidazole is an antiprotozoal antibiotic that serves as a preeminent anaerobic chemotherapeutic agent. The aim of this study was to develop technetium-99m-labeled metronidazole radiotracer for the detection of deep-seated bacterial infections. Radiosynthesis of {sup 99m}Tc-metronidazole was carried by reacting reduced technetium-99m and metronidazole at neutral pH for 30 min. The stannous chloride dihydrate was used as the reducing agent. At optimum radiolabeling conditions, ~ 94% radiochemical was obtained. Quality control analysis was carried out with a chromatographic paper and instant thin-layer chromatographic analysis. The biodistribution study of radiochemical was performed using Escherichia coli bacterial infection-induced rat model. The scintigraphic study was performed using E. coli bacterial infection-induced rabbit model. The results showed promising accumulation at the site of infection and its rapid clearance from the body. The tracer showed target-to-non-target ratio 5.57 ± 0.04 at 1 h post-injection. The results showed that {sup 99m}Tc-MNZ has promising potential to accumulate at E. coli bacterial infection that can be used for E. coli infection imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of cylindrically polarized vector vortex beams with digital micromirror device

We propose a novel technique to directly transform a linearly polarized Gaussian beam into vector-vortex beams with various spatial patterns. Full high-quality control of amplitude and phase is implemented via a Digital Micro-mirror Device (DMD) binary holography for generating Laguerre-Gaussian, Bessel-Gaussian, and helical Mathieu–Gaussian modes, while a radial polarization converter (S-waveplate) is employed to effectively convert the optical vortices into cylindrically polarized vortex beams. Additionally, the generated vector-vortex beams maintain their polarization symmetry after arbitrary polarization manipulation. Due to the high frame rates of DMD, rapid switching among a series of vector modes carrying different orbital angular momenta paves the way for optical microscopy, trapping, and communication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Report on Characterization and Processing of MDD Powder

Uranium oxide powers most civilian nuclear reactors worldwide. A large infrastructure based on a well-established technology is in place to support this strategic component of the energy industry. Because uranium oxide fuels are used so ubiquitously, it is expected that ceramic fuel pellets will continue to be used. A better understanding of the properties of the starting materials, the processing methods used to fabricate fuel pellets and how the properties of pellets change in service, are important aspects being studied via experiments, models and simulations. A close integration of these approaches is essential if we are to find new ways to optimize both the fuel composition and structure for the purpose of improving performance, e.g., designed microstructures, reducing process losses, e.g. by net shape sintering, and enabling reprocessing of used fuel; e.g., incorporation of transuranics. Ceramic oxide fuel pellets are typically cold pressed and sintered from a powder feedstock. Consequently, a complete understanding of pellet fabrication requires a thorough knowledge of the process from powder synthesis through quality control and acceptance. In this study, uranium oxide powder synthesized by Modified Direct Denitration (MDD) is evaluated. Use of powders synthesized by novel, simplified approaches such as MDD are both a challenge and an opportunity. The MDD synthesis process offers an opportunity to simplify the fabrication process potentially reducing process losses. MDD also provides a simple path to incorporate transuranics from used fuel reprocessing with minimal handling. The challenge is to demonstrate and ultimately prove the reliability and reproducibility of simplified processing with the performance of fuel pellets experiencing in-pile service. This report summarizes a processing study of uranium oxide pellets made from MDD uranium oxide.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

60 APPLIED LIFE SCIENCES↗

Chromium-Based Mitigation Coatings on SiC Materials for Fuel Cladding

SiC composites are undergoing assessment under the Advanced Fuels Campaign for Light Water Reactors (LWR) as an Accident Tolerant Fuel (ATF) cladding. As noted, the main concern has been the hydrothermal corrosion of SiC under all LWR chemistries, resulting in cladding oxidation and recession unacceptable for the duration of burn-up. Improvements in future fuel burn-up further increase recession mitigation requirements. Hermeticity of ceramic cladding may also be a concern in terms of quality control. Coatings are being investigated as a practical solution to address concerns regarding SiC cladding for both accident conditions and normal operations. SiC materials were coated by various technologies to produce Cr-based mitigation coatings as a corrosion barrier in LWR water chemistry. In all cases, deposition of Cr compounds requires that SiC behave as a cathode during processing, which requires surface electrical conductivity. Morphology and phase analysis of the coatings are still undergoing investigation, mainly for predicting differential swelling, thermal expansion and microcracking. Autoclave corrosion and in-pile irradiation in a PWR water loop will follow in mid-2016. (authors)

36 MATERIALS SCIENCE↗

Custom data support for the FAst -physics System Testbed and Research (FASTER) Project

The multi-institution FAst -physics System Testbed and Research (FASTER) project, funded by the DOE Earth System Modeling program, aims to evaluate and improve the parameterizations of fast processes (those involving clouds, precipitation and aerosols) in global climate models, using a combination of numerical prediction models, single column models, cloud resolving models, large-eddy simulations, full global climate model output and ARM active and passive remote sensing and in-situ data. This poster presents the Custom Data Support effort for the FASTER project. The effort will provide tailored datasets, statistics, best estimates and quality control data, as needed and defined by FASTER participants, for use in evaluating and improving parameterizations of fast processes in GCMs. The data support will include custom gridding and averaging, for the model of interest, using high time resolution and pixel level data from continuous ARM observations and complementary datasets. In addition to the FASTER team, these datasets will be made available to the ARM Science Team. Initial efforts with respect to data product development, priorities, availability and distribution are summarized here with an emphasis on cloud, atmospheric state and aerosol properties as observed during the Spring 2000 Cloud IOP and the Spring 2003 Aerosol IOP at the ARM Southern Great Plains site.

54 ENVIRONMENTAL SCIENCES↗

Proteome and Transcriptome Profiles of a Her2/Neu-driven Mouse Model of Breast Cancer

In recent years, mouse models have proven to be invaluable in expanding our understanding of cancer biology. We have amassed a tremendous amount of proteomics and transcriptomics data profiling blood and tissues from a Her2-driven mouse model of breast cancer that closely recapitulates the pathology and natural history of human breast cancer. The purpose of this report is to make all of these data publicly available in raw and processed forms, as a resource to the community. Importantly, high quality biospecimens from this same mouse model are freely available through a sample repository that we established, so researchers can readily obtain samples to test biological hypotheses without the need of breeding animals and collecting biospecimens. Specifically, six proteomics and six transcriptomics datasets are available, with the former encompassing 841 liquid chromatography-tandem mass spectrometry (LC-MS/MS) experiments of both plasma and tissue samples, and the latter including 255 individual microarray analyses of five different tissue types (thymus, spleen, liver, blood cells, and breast ± laser capture microdissection). A total of 18,880 unique peptides were identified with a PeptideProphet error rate ≤1%, with 3884 non-redundant protein groups identified in five plasma datasets, and 1659 non-redundant protein groups in a tissue dataset (4977 non-redundant protein groups in total). We anticipate that these data will be of use to the community for software tool development, investigations of analytical variation in MS/MS data, development of quality control tools (multiple technical replicates are provided for a subset of the data), empirical selection of proteotypic peptides for multiple reaction monitoring mass spectrometry, and for advancing our understanding of cancer biology.

59 BASIC BIOLOGICAL SCIENCES↗

Maintenance of Maywood Laboratory Operations Support During Contractor Transition and Replacement of the Project Databases - 16329

In December 2013, Cabrera Services (Cabrera) executed transition of the FUSRAP Maywood Superfund Site remediation project operations, including an on-site accredited environmental lab, from a large business that had established technology infrastructure in place for over a decade which required updating to support the expected remediation scope and client needs. As of November 2015, Cabrera has shipped over 116,000 yd{sup 3} of contaminated soil to disposal facilities. During the transition, the USACE FUSRAP Maywood Laboratory (UFML) continued to support project operations, providing the expected timely and reliable results and maintaining their New Jersey Department of Environmental Protection certification for all parameters of concern, while having to cope with new challenges and additional tasks having the potential to disrupt the laboratory's ability to support project operations. This case study examines the challenges with maintaining a certified radiochemistry laboratory and an aggressive remediation schedule during a period of prime contractor transition which included a complete IT infrastructure overhaul, and conversion of the existing Microsoft Access laboratory database and project Electronic Data Management System (EDMS) to a customized commercial solution. Challenges: I. Procurement of a new database subcontractor and working closely with them to achieve the following: a. Migration of all environmental (including radiological, chemical, and quality control), health and safety, and spatial data as well as reports, queries, and analytical instrument software processes from a MS Access data management system to a SQL server system; and b. Verification that the functionality and data integrity of the databases remained intact. II. The onsite laboratory was changed over to a new onsite network and the following tasks were completed with little or no interruption to site operations by January 10, 2014: i. Installation of new instrument personal computers (PCs) and making them fully operational; ii. Configuration of the lab domain and server to host the LIMS (replaced all servers/domain/workstations with Windows 7 and Server 2012 machines). iii. Networking of the laboratory building into the rest of the project site via fiber optic cabling across the site. iv. Upgrade of the wide area network (WAN) data connection to high-speed Fiber Optic service; v. Upgrade of the telephones into voice over internet protocol (VOIP) phones. vi. Splitting of the database into front ends and a centralized back-end hosted on the new server to allow simultaneous access for fixes and improvements. III. Phone service interruption; phone systems were operational by January 10, 2014. Additional Tasks: I. Revision of the USACE FUSRAP Maywood Laboratory (UFML) Quality Systems Manual Rev. 1 Submitted 01/16/14; II. Writing of the Uniform Federal Policy Quality Assurance Project Plan Rev. 1 (UFP-QAPP) submitted 1/21/14. This document replaced the prior project data quality plan, the Chemical Data Quality Management Plan. III. Support of USACE communications to the New Jersey Department of Environmental Protection (NJDEP) on lab management and personnel transition to Cabrera. This work was important since it ensured a smooth transition and shows how critical project records infrastructure such as databases, can be upgraded with minimal interruption of project support. Such work may provide benefit to other similar projects, especially long term projects where database infrastructure upgrades may be beneficial in terms of improved efficiencies in data recording and transfer, and improved security in data storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser-induced breakdown spectroscopy in industrial and security applications

Laser-induced breakdown spectroscopy (LIBS) offers rapid, localized chemical analysis of solid or liquid materials with high spatial resolution in lateral and depth profiling, without the need for sample preparation. Principal component analysis and partial least squares algorithms were applied to identify a variety of complex organic and inorganic samples. This work illustrates how LIBS analyzers can answer a multitude of real-world needs for rapid analysis, such as determination of lead in paint and children's toys, analysis of electronic and solder materials, quality control of fiberglass panels, discrimination of coffee beans from different vendors, and identification of generic versus brand-name drugs. Lateral and depth profiling was performed on children's toys and paint layers. Traditional one-element calibration or multivariate chemometric procedures were applied for elemental quantification, from single laser shot determination of metal traces at {approx}10 {mu}g/g to determination of halogens at 90 {mu}g/g using 50-shot spectral accumulation. The effectiveness of LIBS for security applications was demonstrated in the field by testing the 50-m standoff LIBS rasterizing detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prevalence and variability in reporting of clinically actionable incidental findings on attenuation-correction CT scans in a veteran population

Background: Myocardial perfusion imaging (MPI) often employs attenuation-correction computed tomography (CTAC) to reduce attenuation artifacts and improve specificity. While there is no specific guideline on how they should be reported, incidental noncardiac findings identified on these scans may be clinically significant. The prevalence of these findings in veterans is not currently known. In addition, variability in reporting these findings may depend on the interpreting physician’s specialty. Methods: To guide future decision-making, CTACs in veterans referred for MPI were prospectively evaluated in a quality-control project for a set of prespecified actionable incidental findings by cardiologists and a radiologist. Results: On the 771 scans performed over eight months, 285 incidental noncardiac findings were identified by the interpreting cardiologists and 378 were identified by the interpreting radiologist. Pulmonary nodules were the most common occurring in 20% of studies read by the radiologist. Interreader agreements between cardiologists and the radiologist were poor for pulmonary nodules ≥ 10 mm and hiatal hernias; fair for pulmonary nodules < 10 mm, extracardiac masses, and aortic aneurysms; and moderate for pleural plaques. Conclusion: Incidental noncardiac findings on CTACs are common in our veteran population. Overall interobserver agreement in identifying these findings between cardiologists and radiologists is fair. Specific guidelines are needed on how CTACs should be read and reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Promiscuous activity of ER glucosidase II discovered through donor specificity analysis of UGGT

Research highlights: {yields} UGGT has a narrow donor specificity. {yields} UGGT gave several non-natural high-mannose-type glycans. {yields} G-II has a promiscuous activity as broad specificity hexosidase. -- Abstract: In glycoprotein quality control system in the endoplasmic reticulum (ER), UGGT (UDP-glucose:glycoprotein glucosyltransferase) and glucosidase II (G-II) play key roles. UGGT serves as a glycoprotein folding sensor by virtue of its unique specificity to glucosylate glycoproteins at incompletely folded stage. By using various UDP-Glc analogues, we first analyzed donor specificity of UGGT, which was proven to be rather narrow. However, marginal activity was observed with UDP-galactose and UDP-glucuronic acid as well as with 3-, 4- and 6-deoxy glucose analogues to give corresponding transfer products. Intriguingly, G-II smoothly converted all of them back to Man{sub 9}GlcNAc{sub 2}, providing an indication that G-II has a promiscuous activity as a broad specificity hexosidase.

60 APPLIED LIFE SCIENCES↗

Assessment of Geo-Kompsat-2A Atmospheric Motion Vector Data and Its Assimilation Impact in the GEOS Atmospheric Data Assimilation System

Korea’s second geostationary meteorological satellite, Geo-Kompsat-2A (Geostationary-Korean Multi-Purpose Satellite-2A, GK2A), was successfully launched on 4 December 2018. GK2Agenerates Atmospheric Motion Vectors (AMVs) every 10 min in the full disk area. This data hasbeen disseminated via Global Telecommunication System (GTS) since 25 October 2019. This articleevaluates the quality of GK2A AMVs in the Goddard Earth Observing System (GEOS) atmosphericdata assimilation system (ADAS). The data show slow wind speed biases at 200–300 hPa and 600–800hPa in the northern and southern hemispheres. These biases are caused by observation heightassignment errors near jet streams. The Equivalent Blackbody Temperature (EBBT) method of GK2Atends to assign clouds at higher altitude, which mainly causes slow wind speed biases, especially inthe lower atmosphere. The IR/WV intercept method of GK2A assigns clouds slightly lower in theatmospheric layers below the altitude of 400 hPa, which causes positive biases. Quality control (QC)criteria to select the most suitable GK2A AMV data for assimilation are presented based on thesequality assessments. A new QC criterion utilizing height errors within the GEOS ADAS is introducedto exclude data with slow wind speed biases and large errors. GEOS forecast accuracy is slightlyimproved after assimilating GK2A AMVs along with other conventional, radiance, and satellitewinds which include AMVs made by the Himawari-8 satellite in nearly the same observational areaof GK2A. Additionally, the present work shows that GEOS forecasts can be significantly improved,especially in the tropics and southern hemisphere after assimilating GK2A data in the absence ofHimawari-8 AMVs. This study demonstrates that GK2A AMV data is a valuable data source toenhance the robustness of GEOS ADAS.

Atmospheric Motion Vectors↗

Engineering and exploitation of a fluorescent HIV-1 gp120 for live cell CD4 binding assays

The HIV-1 envelope glycoprotein, gp120, binds the host cell receptor, CD4, in the initial step of HIV viral entry and infection. This process is an appealing target for the development of inhibitory drugs and neutralizing antibodies. To study gp120 binding and intracellular trafficking, we engineered a fluorescent fusion of the humanized gp120 JRFL HIV-1 variant and GFP. Gp120-sfGFP is glycosylated with human sugars, robustly expressed, and secreted from cultured human cells. Protein dynamics, quality control, and trafficking can be visualized in live cells. The fusion protein can be readily modified with different gp120 variants or fluorescent proteins. Finally, secreted gp120-sfGFP enables a sensitive and easy binding assay that can quantitatively screen potential inhibitors of gp120-CD4 binding on live cells via fluorescence imaging or laser scanning cytometry. This adaptable research tool should aid in studies of gp120 cell biology and the development of novel anti-HIV drugs. - Highlights: • Development of fluorescent protein labeled HIV-1 envelope gp120. • Imaging of gp120 dynamics and trafficking in live cells. • Quantitative visual assay of antibody-mediated inhibition of gp120 binding to CD4 on live cells.

60 APPLIED LIFE SCIENCES↗

WE-AB-206-00: Diagnostic QA/QC Hands-On Workshop

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗